920 resultados para Active-reactive optimal power flow


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Large scale wind power generation complicated with restrictions on the tie line plans may lead to significant wind power curtailment and deep cycling of coal units during the valley load periods. This study proposes a dispatch strategy for interconnected wind-coal intensive power systems (WCISs). Wind power curtailment and cycling of coal units are included in the economic dispatch analysis of regional systems. Based on the day-ahead dispatch results, a tie line power plan adjustment strategy is implemented in the event of wind power curtailment or deep cycling occurring in the economic dispatch model, with the objective of reducing such effects. The dispatch strategy is designed based on the distinctive operation characteristics of interconnected WCISs, and dispatch results for regional systems in China show that the proposed strategy is feasible and can improve the overall system operation performance.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Le Système Stockage de l’Énergie par Batterie ou Batterie de Stockage d’Énergie (BSE) offre de formidables atouts dans les domaines de la production, du transport, de la distribution et de la consommation d’énergie électrique. Cette technologie est notamment considérée par plusieurs opérateurs à travers le monde entier, comme un nouveau dispositif permettant d’injecter d’importantes quantités d’énergie renouvelable d’une part et d’autre part, en tant que composante essentielle aux grands réseaux électriques. De plus, d’énormes avantages peuvent être associés au déploiement de la technologie du BSE aussi bien dans les réseaux intelligents que pour la réduction de l’émission des gaz à effet de serre, la réduction des pertes marginales, l’alimentation de certains consommateurs en source d’énergie d’urgence, l’amélioration de la gestion de l’énergie, et l’accroissement de l’efficacité énergétique dans les réseaux. Cette présente thèse comprend trois étapes à savoir : l’Étape 1 - est relative à l’utilisation de la BSE en guise de réduction des pertes électriques ; l’Étape 2 - utilise la BSE comme élément de réserve tournante en vue de l’atténuation de la vulnérabilité du réseau ; et l’Étape 3 - introduit une nouvelle méthode d’amélioration des oscillations de fréquence par modulation de la puissance réactive, et l’utilisation de la BSE pour satisfaire la réserve primaire de fréquence. La première Étape, relative à l’utilisation de la BSE en vue de la réduction des pertes, est elle-même subdivisée en deux sous-étapes dont la première est consacrée à l’allocation optimale et le seconde, à l’utilisation optimale. Dans la première sous-étape, l’Algorithme génétique NSGA-II (Non-dominated Sorting Genetic Algorithm II) a été programmé dans CASIR, le Super-Ordinateur de l’IREQ, en tant qu’algorithme évolutionniste multiobjectifs, permettant d’extraire un ensemble de solutions pour un dimensionnement optimal et un emplacement adéquat des multiple unités de BSE, tout en minimisant les pertes de puissance, et en considérant en même temps la capacité totale des puissances des unités de BSE installées comme des fonctions objectives. La première sous-étape donne une réponse satisfaisante à l’allocation et résout aussi la question de la programmation/scheduling dans l’interconnexion du Québec. Dans le but de réaliser l’objectif de la seconde sous-étape, un certain nombre de solutions ont été retenues et développées/implantées durant un intervalle de temps d’une année, tout en tenant compte des paramètres (heure, capacité, rendement/efficacité, facteur de puissance) associés aux cycles de charge et de décharge de la BSE, alors que la réduction des pertes marginales et l’efficacité énergétique constituent les principaux objectifs. Quant à la seconde Étape, un nouvel indice de vulnérabilité a été introduit, formalisé et étudié ; indice qui est bien adapté aux réseaux modernes équipés de BES. L’algorithme génétique NSGA-II est de nouveau exécuté (ré-exécuté) alors que la minimisation de l’indice de vulnérabilité proposé et l’efficacité énergétique représentent les principaux objectifs. Les résultats obtenus prouvent que l’utilisation de la BSE peut, dans certains cas, éviter des pannes majeures du réseau. La troisième Étape expose un nouveau concept d’ajout d’une inertie virtuelle aux réseaux électriques, par le procédé de modulation de la puissance réactive. Il a ensuite été présenté l’utilisation de la BSE en guise de réserve primaire de fréquence. Un modèle générique de BSE, associé à l’interconnexion du Québec, a enfin été proposé dans un environnement MATLAB. Les résultats de simulations confirment la possibilité de l’utilisation des puissances active et réactive du système de la BSE en vue de la régulation de fréquence.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

La carbonatation minérale dans les résidus miniers est un moyen sûr et permanent de séquestrer le CO2 atmosphérique. C’est un processus naturel et passif qui ne nécessite aucun traitement particulier et donc avantageux d’un point de vue économique. Bien que la quantité de CO2 qu’il soit possible de séquestrer selon ce processus est faible à l’échelle globale, dans le cadre d’un marché du carbone, les entreprises minières pourraient obtenir des crédits et ainsi revaloriser leurs résidus. À l’heure actuelle, il y a peu d’informations pour quantifier le potentiel de séquestration du CO2 de façon naturelle et passive dans les piles de résidus miniers. Il est donc nécessaire d’étudier le phénomène pour comprendre comment évolue la réaction à travers le temps et estimer la quantité de CO2 qui peut être séquestrée naturellement dans les piles de résidus. Plusieurs travaux de recherche se sont intéressés aux résidus miniers de Thetford Mines (Québec, Canada), avec une approche principalement expérimentale en laboratoire. Ces travaux ont permis d’améliorer la compréhension du processus de carbonatation, mais ils nécessitent une validation à plus grande échelle sous des conditions atmosphériques réelles. L’objectif général de cette étude est de quantifier le processus de carbonatation minérale des résidus miniers sous des conditions naturelles, afin d’estimer la quantité de CO2 pouvant être piégée par ce processus. La méthodologie utilisée repose sur la construction de deux parcelles expérimentales de résidus miniers situées dans l’enceinte de la mine Black Lake (Thetford Mines). Les résidus miniers sont principalement constitués de grains et de fibres de chrysotile et lizardite mal triés, avec de petites quantités d’antigorite, de brucite et de magnétite. Des observations spatiales et temporelles ont été effectuées dans les parcelles concernant la composition et la pression des gaz, la température des résidus, la teneur en eau volumique, la composition minérale des résidus ainsi que la chimie de l’eau des précipitations et des lixiviats provenant des parcelles. Ces travaux ont permis d’observer un appauvrissement notable du CO2 dans les gaz des parcelles (< 50 ppm) ainsi que la précipitation d’hydromagnésite dans les résidus, ce qui suggère que la carbonatation minérale naturelle et passive est un processus potentiellement important dans les résidus miniers. Après 4 ans d’observations, le taux de séquestration du CO2 dans les parcelles expérimentales a été estimé entre 3,5 et 4 kg/m3/an. Ces observations ont permis de développer un modèle conceptuel de la carbonatation minérale naturelle et passive dans les parcelles expérimentales. Dans ce modèle conceptuel, le CO2 atmosphérique (~ 400 ppm) se dissout dans l’eau hygroscopique contenue dans les parcelles, où l’altération des silicates de magnésium forme des carbonates de magnésium. La saturation en eau dans les cellules est relativement stable dans le temps et varie entre 0,4 et 0,65, ce qui est plus élevé que les valeurs de saturation optimales proposées dans la littérature, réduisant ainsi le transport de CO2 dans la zone non saturée. Les concentrations de CO2 en phase gazeuse, ainsi que des mesures de la vitesse d’écoulement du gaz dans les cellules suggèrent que la réaction est plus active près de la surface et que la diffusion du CO2 est le mécanisme de transport dominant dans les résidus. Un modèle numérique a été utilisé pour simuler ces processus couplés et valider le modèle conceptuel avec les observations de terrain. Le modèle de transport réactif multiphase et multicomposant MIN3P a été utilisé pour réaliser des simulations en 1D qui comprennent l’infiltration d’eau à travers le milieu partiellement saturé, la diffusion du gaz, et le transport de masse réactif par advection et dispersion. Même si les écoulements et le contenu du lixivat simulés sont assez proches des observations de terrain, le taux de séquestration simulé est 22 fois plus faible que celui mesuré. Dans les simulations, les carbonates précipitent principalement dans la partie supérieure de la parcelle, près de la surface, alors qu’ils ont été observés dans toute la parcelle. Cette différence importante pourrait être expliquée par un apport insuffisant de CO2 dans la parcelle, qui serait le facteur limitant la carbonatation. En effet, l’advection des gaz n’a pas été considérée dans les simulations et seule la diffusion moléculaire a été simulée. En effet, la mobilité des gaz engendrée par les fluctuations de pression barométrique et l’infiltration de l’eau, ainsi que l’effet du vent doivent jouer un rôle conséquent pour alimenter les parcelles en CO2.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In the deregulated Power markets it is necessary to have a appropriate Transmission Pricing methodology that also takes into account “Congestion and Reliability”, in order to ensure an economically viable, equitable, and congestion free power transfer capability, with high reliability and security. This thesis presents results of research conducted on the development of a Decision Making Framework (DMF) of concepts and data analytic and modelling methods for the Reliability benefits Reflective Optimal “cost evaluation for the calculation of Transmission Cost” for composite power systems, using probabilistic methods. The methodology within the DMF devised and reported in this thesis, utilises a full AC Newton-Raphson load flow and a Monte-Carlo approach to determine, Reliability Indices which are then used for the proposed Meta-Analytical Probabilistic Approach (MAPA) for the evaluation and calculation of the Reliability benefit Reflective Optimal Transmission Cost (ROTC), of a transmission system. This DMF includes methods for transmission line embedded cost allocation among transmission transactions, accounting for line capacity-use as well as congestion costing that can be used for pricing using application of Power Transfer Distribution Factor (PTDF) as well as Bialek’s method to determine a methodology which consists of a series of methods and procedures as explained in detail in the thesis for the proposed MAPA for ROTC. The MAPA utilises the Bus Data, Generator Data, Line Data, Reliability Data and Customer Damage Function (CDF) Data for the evaluation of Congestion, Transmission and Reliability costing studies using proposed application of PTDF and other established/proven methods which are then compared, analysed and selected according to the area/state requirements and then integrated to develop ROTC. Case studies involving standard 7-Bus, IEEE 30-Bus and 146-Bus Indian utility test systems are conducted and reported throughout in the relevant sections of the dissertation. There are close correlation between results obtained through proposed application of PTDF method with the Bialek’s and different MW-Mile methods. The novel contributions of this research work are: firstly the application of PTDF method developed for determination of Transmission and Congestion costing, which are further compared with other proved methods. The viability of developed method is explained in the methodology, discussion and conclusion chapters. Secondly the development of comprehensive DMF which helps the decision makers to analyse and decide the selection of a costing approaches according to their requirements. As in the DMF all the costing approaches have been integrated to achieve ROTC. Thirdly the composite methodology for calculating ROTC has been formed into suits of algorithms and MATLAB programs for each part of the DMF, which are further described in the methodology section. Finally the dissertation concludes with suggestions for Future work.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

As the semiconductor industry struggles to maintain its momentum down the path following the Moore's Law, three dimensional integrated circuit (3D IC) technology has emerged as a promising solution to achieve higher integration density, better performance, and lower power consumption. However, despite its significant improvement in electrical performance, 3D IC presents several serious physical design challenges. In this dissertation, we investigate physical design methodologies for 3D ICs with primary focus on two areas: low power 3D clock tree design, and reliability degradation modeling and management. Clock trees are essential parts for digital system which dissipate a large amount of power due to high capacitive loads. The majority of existing 3D clock tree designs focus on minimizing the total wire length, which produces sub-optimal results for power optimization. In this dissertation, we formulate a 3D clock tree design flow which directly optimizes for clock power. Besides, we also investigate the design methodology for clock gating a 3D clock tree, which uses shutdown gates to selectively turn off unnecessary clock activities. Different from the common assumption in 2D ICs that shutdown gates are cheap thus can be applied at every clock node, shutdown gates in 3D ICs introduce additional control TSVs, which compete with clock TSVs for placement resources. We explore the design methodologies to produce the optimal allocation and placement for clock and control TSVs so that the clock power is minimized. We show that the proposed synthesis flow saves significant clock power while accounting for available TSV placement area. Vertical integration also brings new reliability challenges including TSV's electromigration (EM) and several other reliability loss mechanisms caused by TSV-induced stress. These reliability loss models involve complex inter-dependencies between electrical and thermal conditions, which have not been investigated in the past. In this dissertation we set up an electrical/thermal/reliability co-simulation framework to capture the transient of reliability loss in 3D ICs. We further derive and validate an analytical reliability objective function that can be integrated into the 3D placement design flow. The reliability aware placement scheme enables co-design and co-optimization of both the electrical and reliability property, thus improves both the circuit's performance and its lifetime. Our electrical/reliability co-design scheme avoids unnecessary design cycles or application of ad-hoc fixes that lead to sub-optimal performance. Vertical integration also enables stacking DRAM on top of CPU, providing high bandwidth and short latency. However, non-uniform voltage fluctuation and local thermal hotspot in CPU layers are coupled into DRAM layers, causing a non-uniform bit-cell leakage (thereby bit flip) distribution. We propose a performance-power-resilience simulation framework to capture DRAM soft error in 3D multi-core CPU systems. In addition, a dynamic resilience management (DRM) scheme is investigated, which adaptively tunes CPU's operating points to adjust DRAM's voltage noise and thermal condition during runtime. The DRM uses dynamic frequency scaling to achieve a resilience borrow-in strategy, which effectively enhances DRAM's resilience without sacrificing performance. The proposed physical design methodologies should act as important building blocks for 3D ICs and push 3D ICs toward mainstream acceptance in the near future.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

With the increasing of the distributed generation, DC microgrids have become more and more common in the electrical network. To connect devices in a microgrid, converter are necessary, but they are also source of disturbances due to their functioning. In this thesis, measurement and simulation of conducted emissions, within the frequency range 2-150kHz, of a DC/DC buck converter are studied.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

One of the major issues for power converters that are connected to the electric grid are the measurement of three phase Conduced Emissions (CE), which are regulated by international and regional standards. CE are composed of two components which are Common Mode (CM) noise and Differential Mode (DM) noise. To achieve compliance with these regulations the Equipment Under Test (EUT) includes filtering and other electromagnetic emission control strategies. The separation of differential mode and common mode noise in Electromagnetic Interference (EMI) analysis is a well-known procedure which is useful especially for the optimization of the EMI filter, to improve the CM or DM attenuation depending on which component of the conducted emissions is predominant, and for the analysis and the understanding of interference phenomena of switched mode power converters. However, separating both components is rarely done during measurements. Therefore, in this thesis an active device for the separation of the CM and DM EMI noise in three phase power electronic systems has been designed and experimentally analysed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Response surface methodology based on Box-Behnken (BBD) design was successfully applied to the optimization in the operating conditions of the electrochemical oxidation of sanitary landfill leachate aimed for making this method feasible for scale up. Landfill leachate was treated in continuous batch-recirculation system, where a dimensional stable anode (DSA(©)) coated with Ti/TiO2 and RuO2 film oxide were used. The effects of three variables, current density (milliampere per square centimeter), time of treatment (minutes), and supporting electrolyte dosage (moles per liter) upon the total organic carbon removal were evaluated. Optimized conditions were obtained for the highest desirability at 244.11 mA/cm(2), 41.78 min, and 0.07 mol/L of NaCl and 242.84 mA/cm(2), 37.07 min, and 0.07 mol/L of Na2SO4. Under the optimal conditions, 54.99 % of chemical oxygen demand (COD) and 71.07 ammonia nitrogen (NH3-N) removal was achieved with NaCl and 45.50 of COD and 62.13 NH3-N with Na2SO4. A new kinetic model predicted obtained from the relation between BBD and the kinetic model was suggested.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Focal cryoablation (FC), brachytherapy (B) and active surveillance (AS) were offered to patients diagnosed with very low-risk prostate cancer (VLRPC) in an equal access protocol. Comprehensive validated self-report questionnaires accessed patients' erectile (IIEF-5) and voiding (IPSS) functions, Beck scales measured anxiety (BAI), hopelessness (BHS) and depression (BDI), SF-36 reflected patients' quality of life added to the emotional thermometers including five visual analogue scales (distress, anxiety, depression, anger and need for help). Kruskal-Wallis or ANOVA tests and Spearman's correlations were obtained among groups and studied variables. Thirty patients were included, median follow-up 18 months (15-21). Those on AS (n = 11) were older, presented higher hopelessness (BHS) and lower general health perceptions (SF-36) scores than patients opting for FC (n = 10) and B (n = 9), P = 0.0014, P = 0.0268 and P = 0.0168 respectively. Patients on B had higher IPSS scores compared to those under FC and AC, P = 0.0223. For all 30 included patients, Spearman's correlation (rs ) was very strong between BHS and general health perceptions (rs  = -0.800, P < 0.0001), and weak/moderate between age and BHS (rs  = 0.405, P = 0.026) and age and general health perceptions (rs  = -0.564, P = 0.001). The sample power was >60%. To be considered in patients' counselling and care, current study supports the hypothesis that even VLRPC when untreated undermines psychosocial domains.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Estresse oxidativo é o termo geralmente utilizado para descrever os danos causados pelo desequilíbrio entre pró-oxidantes e antioxidantes no organismo. O aumento no consumo de O2 induzido pelo exercício físico está associado ao aumento das espécies reativas de oxigênio (EROs) sendo estas indutoras do estresse oxidativo. Embora as evidências indiquem um provável efeito inibitório da fototerapia com diodos emissores de luz (LEDT) sobre a produção das EROs, não existem estudos observando tal efeito em atletas. Este estudo preliminar destina-se a verificar os efeitos da aplicação de LEDT previamente ao exercício de alta intensidade sobre a peroxidação lipídica, mensurada através dos níveis sanguíneos de substâncias reativas ao ácido tiobarbitúrico (TBARS). Todos os seis atletas de voleibol do sexo masculino foram submetidos às duas situações: aplicação de LEDT efetiva e aplicação de LEDT placebo. O desempenho no protocolo de exercício adotado não revelou diferença (p > 0,05) entre as duas situações nas variáveis potência pico, potência média e índice de fadiga. Os resultados relacionados com a peroxidação lipídica foram: na situação LEDT efetiva, não foi possível observar diferença estatisticamente significante (p > 0,05) entre os níveis pré e pós-exercício (6,98 ± 0,81 e 7,02 ± 0,47nmol/mL); na situação LEDT (LBP) placebo, houve diferença estatisticamente significante (p = 0,05) entre os valores pré e pós-exercício (7,09 ± 1,28 e 8,43 ± 0,71nmol/mL). Tais resultados demonstram que a aplicação efetiva de LEDT parece ser eficaz no controle da peroxidação lipídica em atletas submetidos a exercício intenso