984 resultados para swine flu


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Despite the WHO recommendation that the 2010-2011 trivalent seasonal flu vaccine must contain A/California/7/2009/H1N1-like virus there is no consistent data regarding its immunogenicity and safety in a large autoimmune rheumatic disease (ARD) population. Methods 1668 ARD patients (systemic lupus erythematosus (SLE), rheumatoid arthritis (RA), ankylosing spondylitis (AS), systemic sclerosis, psoriatic arthritis (PsA), Behcet`s disease (BD), mixed connective tissue disease, primary antiphospholipid syndrome (PAPS), dermatomyositis (DM), primary Sjogren`s syndrome, Takayasu`s arteritis, polymyositis and Granulomatosis with polyangiitis (Wegener`s) (GPA)) and 234 healthy controls were vaccinated with a non-adjuvanted influenza A/California/7/2009(H1N1) virus-like strain flu. Subjects were evaluated before vaccination and 21 days post-vaccination. The percentage of seroprotection, seroconversion and the factor increase in geometric mean titre (GMT) were calculated. Results After immunisation, seroprotection rates (68.5% vs 82.9% p < 0.0001), seroconversion rates (63.4% vs 76.9%, p < 0.001) and the factor increase in GMT (8.9 vs 13.2 p < 0.0001) were significantly lower in ARD than controls. Analysis of specific diseases revealed that seroprotection significantly reduced in SLE (p < 0.0001), RA (p < 0.0001), PsA (p=0.0006), AS (p=0.04), BD (p=0.04) and DM (p=0.04) patients than controls. The seroconversion rates in SLE (p < 0.0001), RA (p < 0.0001) and PsA (p=0.0006) patients and the increase in GMTs in SLE (p < 0.0001), RA (p < 0.0001) and PsA (p < 0.0001) patients were also reduced compared with controls. Moderate and severe side effects were not reported. Conclusions The novel recognition of a diverse vaccine immunogenicity profile in distinct ARDs supports the notion that a booster dose may be recommended for diseases with suboptimal immune responses. This large study also settles the issue of vaccine safety. (ClinicalTrials.gov #NCT01151644)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Xenotransplantation and multivisceral transplantation are advanced therapeutic methods that still require a scientific basis. There are no experimental models of multivisceral transplantation available, particularly not the monitoring by endoscopy. Here, we describe the endoscopic features in a model of multivisceral xenotransplantation. Methods: The distal esophagus, stomach, intestine, colon, liver, pancreas, and the kidneys with a common vascular pedicle were harvested from rabbits and implanted in swine (group I, n = 9) or in rabbits (group II, n = 4). Endoscopy was performed in the stomach, jejunum, and ascending colon at four consecutive time points (immediate after surgery and 10, 90, and 180 min after reperfusion). Lesions were macroscopically graded as mild, moderate, and severe. Biopsies were taken following sacrifice at 180 min after reperfusion. Results: In group I, the stomach, jejunum, and colon manifested a progression of lesions with predominance of mild lesions after 10 min, mild to moderate lesions after 90 min, and moderate to severe lesions after 180 min. In animals from group II, endoscopy showed normal features at all time points after reperfusion. Histopathologic analysis confirmed the diagnosis of hyperacute rejection in group I. Grafts from group II animals presented normal or mild ischemic/reperfusion injury. Conclusion: All animals subjected to multivisceral xenotransplantation showed a progression of endoscopic lesions with time after transplantation, while animals subjected to allotransplantation showed no aberrations in endoscopy. We conclude that endoscopy is a useful tool in the assessment of hyperacute rejection of a xenograft.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Organ shortage impairs the proposition of multivisceral transplantation to treat multiple organ failure. Interspecies (xeno) transplantation is a valid solution for organ shortage; however, suitable models of this advance are lacking. We describe an effective model of multivisceral xenotransplantation to study hyperacute rejection. Methods: Under general anesthesia, we in block recovered the distal esophagus, stomach, small bowel, colon, liver, pancreas, spleen, and kidneys from donors and implanted heterotopically in the lower abdomen of recipients. Animals were divided into four groups: I-canine donor, swine recipient (n = 6); II - swine donor, canine recipient (n = 5); III-canine donor, canine recipient (n = 4); and IV-swine donor, swine recipient (n = 5). Groups I and 11 comprised experimental (xenotransplantation) and III and IV control groups (allotransplantation). During the experiment, we appraised recipient evolution and graft modification by sequential biopsy up to 3 h. At this time, we killed animals for autopsy (experimental end point). Results: We accomplished all experiments successfully. Every grafts attained customary appearance and convenient urine output immediately after unclamp. Around 15 min after reperfusion, xenografts achieved signs of progressive hyperacute rejection and absence of urine output. At the end of experiments we observed moderate to severe hyperacute rejection at small bowel, colon, mesenteric lymph node, liver, spleen, pancreas, and kidney, while stomach and esophagus achieved mild lesions. In contrast, allograft achieved normal or minimum ischemia/reperfusion injury and constant urine output. Conclusion: The present procedure assembles a simple and effective model to study multivisceral xenotransplantation and may ultimately spread researches toward hyperacute rejection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rationale: There are no reports of the systemic human pathology of the novel swine H1N1 influenza (S-OIV) infection. Objectives: The autopsy findings of 21 Brazilian patients with confirmed S-OIV infection are presented. These patients died in the winter of the southern hemisphere 2009 pandemic, with acute respiratory failure. Methods: Lung tissue was submitted to virologic and bacteriologic analysis with real-time reverse transcriptase polymerase chain reaction and electron microscopy. Expression of toll-like receptor (TLR)-3, IFN-gamma, tumor necrosis factor-alpha, CD8(+) T cells and granzyme B(+) cells in the lungs was investigated by immunohistochemistry. Measurements and Main Results: Patients were aged from 1 to 68 years (72% between 30 and 59 yr) and 12 were male. Sixteen patients had preexisting medical conditions. Diff use alveolar damage was present in 20 individuals. in six patients, diffuse alveolar damage was associated with necrotizing bronchiolitis and in five with extensive hemorrhage. There was also a cytopathic effect in the bronchial and alveolar epithelial cells, as well as necrosis, epithelial hyperplasia, and squamous metaplasia of the large airways. There was marked expression of TLR-3 and IFN-gamma and a large number of CD8(+) T cell sand granzyme B(+) cells within the lung tissue. Changes in other organs were mainly secondary to multiple organ failure. Conclusions: Autopsies have shown that the main pathological changes associated with S-OIV infection are localized to the lungs, where three distinct histological patterns can be identified. We also show evidence of ongoing pulmonary aberrant immune response. Our results reinforce the usefulness of autopsy in increasing the understanding of the novel human influenza A (H1N1) infection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The swine is an essential model for carrying out preclinical research and for teaching complex surgical procedures. There is a lack of experimental models describing anatomical and surgical aspects of total pancreatectomy in the pig. Materials and Methods: The experiments were performed on 10 white male swine weighing 27-33 kg. The animals were premedicated with midazolam (0.4 mg/kg, i.m.) and ketamine (4 mg/kg, i.m.). Anesthesia was induced with propofol (1-2 mg/kg, i.v.) and was maintained with propofol and fentanyl (0.3 mg and 0.1 mu g/kg/min, respectively, i.v.). The surgical period ranged from 44 to 77 min. The pancreas anatomy, and the main arterial, venous and pancreatic duct anatomy were assessed. Results: The pancreas anatomy was composed of 3 lobes, the `splenic`, `duodenal` and `connecting` lobe which is attached to the anterior portion of the portal vein. The splenic artery and the junction of the splenic vein and portal vein were divided. The left gastric artery was dissected and separated from its origin at the splenic artery. The head of the pancreas is disposed in a C shape. The pancreas was dissected and liberated from the right portion of the portal vein and the infrahepatic vena cava. The pancreas was separated from the duodenum preserving the pancreaticoduodenal artery, then we performed the total pancreatectomy preserving the duodenum, common bile duct and spleen. Conclusion: Total pancreatectomy with duodenum, bile duct and spleen preservation in the pig is feasible and an important instrument for research purposes and teaching surgical technique. Copyright (C) 2010 S. Karger AG, Basel

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background & Aims: This multi-center study aimed to prospectively evaluate the safety and efficacy of a genotype-based Pegylated Interferon alfa-2a/Ribavirin therapy in treatment-naive hepatitis C virus (HCV), positive HCV serology, and quantifiable HCV RNA, infected children. Methods: Eighteen children with genotypes 2 and 3 patients (group A) were assigned to medication for 24 weeks, and 47 children with genotypes 1, 4, 5 and 6 patients (group B) for 48 weeks. Results: Early response at week 12 was observed in 83% of group A patients and in 57% of group B patients (p <0.05). End of treatment response was achieved in 94% of patients in group A and in 57% in group B (p <0.001). Sustained virologic response was maintained in 89% of patients in group A and in 57% of patients in group B (p <0.01). Ten patients stopped prematurely the treatment, 2 for serious adverse event (acute hepatitis and thyrotoxicosis), and 8 because of no virologic response at week 24. Peginterferon alfa-2a and Ribavirin dose was adjusted in 15 patients (23%), 11 for neutropenia (17%), and 3 patients (5%), for anemia, respectively. Treatment-related adverse events included fever and flu-like symptoms (54%), irritability depression change of mood (34%), vomiting (23%), abdominal pain (38%), loss of appetite (21.5%) and dermatitis (29%). No influence on height growth was observed. Conclusions: Pegylated inteferon alfa-2a and Ribavirin treatment allowed to achieve SVR in 57% of pediatric patients with genotypes 1, 4, 5 and 6, and in 94% of genotypes 2 and 3. These results show an improved SVR as compared to reference series in adults with similar regimen. (c) 2010 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The most common laparoscopic complications are associated with trocar insertion. The purpose of this study was to develop an objective method of evaluating the safety profile of various access devices used in laparoscopic surgery. STUDY DESIGN: In 20 swine, 6 bladed and 2 needle access devices were evaluated. A force profile was determined by measuring the force required to drive the trocar or needle through the fascia and into the peritoneum, at 0 and 10 mmHg. The amount Of tissue deformation, the length of blade exposed, and the duration of exposure were measured using a high-speed digital imaging system. RESULTS: The needle system without the sheath required the least driving force and had the most favorable force profile. In contrast, the bladed, nonretractable trocar system required a higher driving force and a rapid loss of resistance. Insertion under a pneumoperitoneum did not significantly alter the force profile of the various access devices except for the amount of tissue deformation. With the bladed system, the blade itself was exposed for an average of 0.5 to 1.0 seconds for a distance of 4.5 to 5.0 cm. In comparison, the needle system was exposed for 0.2 seconds for a distance of 1.8 cm. CONCLUSIONS: We developed a reproducible method of measuring the forces required to place the access systems, their pattern of resistance loss, and the characteristics of the blade exposure. These parameters may provide an adjunctive and objective measurement of safety, allowing for more direct comparison between various trocar designs. (J Am Coll Surg 2009;209:222-232. (C) 2009 by the American College of Surgeons)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and objective The influence of ventilatory settings on static and functional haemodynamic parameters during mechanical ventilation is not completely known. The purpose of this study was to evaluate the effect of positive end-expiratory pressure, tidal volume and inspiratory to expiratory time ratio variations on haemodynamic parameters during haemorrhage and after transfusion of shed blood. Methods Ten anaesthetized pigs were instrumented and mechanically ventilated with a tidal volume of 8 ml kg(-1), a positive end-expiratory pressure of 5 cmH(2)O and an inspiratory to expiratory ratio of 1 : 2. Then, they were submitted in a random order to different ventilatory settings (tidal volume 16 ml kg(-1), positive end-expiratory pressure 15 cmH(2)O or inspiratory to expiratory time ratio 2: 1). Functional and static haemodynamic parameters (central venous pressure, pulmonary artery occlusion pressure, right ventricular end-diastolic volume and pulse pressure variation) were evaluated at baseline, during hypovolaemia (withdrawal of 20% of estimated blood volume) and after an infusion of withdrawn blood (posttransfusion). Results During baseline, a positive end-expiratory pressure of 15cmH(2)O significantly increased pulmonary artery occlusion pressure from 14.6 +/- 1.6 mmHg to 17.4 +/- 1.7 mmHg (P<0.001) and pulse pressure variation from 15.8 +/- 8.5% to 25.3 +/- 9.5% (P<0.001). High tidal volume increased pulse pressure variation from 15.8 8.5% to 31.6 +/- 10.4% (P<0.001), and an inspiratory to expiratory time ratio of 2: 1 significantly increased only central venous pressure. During hypovolaemia, high positive end-expiratory pressure influenced all studied variables, and high tidal volume strongly increased pulse pressure variation (40.5 +/- 12.4% pre vs. 84.2 +/- 19.1 % post, P<0.001). The inversion of the inspiratory to expiratory time ratio only slightly increased filling pressures during hypovolaemia, without without affecting pulse pressure variation or right ventricle end-diastolic volume. Conclusion We concluded that pulse pressure variation measurement is influenced by cyclic variations in intrathoracic pressure, such as those caused by augmentations in tidal volume. The increase in mean airway pressure caused by positive end-expiratory pressure affects cardiac filling pressures and also pulse pressure variation, although to a lesser extent. Inversion of the inspiratory to expiratory time ratio does not induce significant changes in static and functional haemodynamic parameters. Eur J Anaesthesiol 26:66-72 (c) 2009 European Society of Anaesthesiology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. A variety of techniques can be used to achieve stabilization of femoral valgus osteotomies in children, but what is lacking is a versatile fixation system that associates stability and versatility at different ages and for different degrees of deformity. Methods. Mechanical tests of three configurations used to fix femoral valgus osteotomies, based oil the tension band wire principle, were carried out. A 30 degrees wedge valgus osteotomy was performed at the subtrochanteric level in 60 swine femurs and fixed with three different systems. In Group 1, two Kirschner wires (K wire) were introduced from the tip of the greater trochanter to the medial cortex, crossing the osteotomy. A flexible steel wire was anchored to the K wires into holes in the lateral cortex and tightened to form a tension band. The same setup was used in Group 2, but two additional smooth K wires were inserted into the lateral surface of the greater trochanter and driven to the femoral head with the distal extremities bent and tied around tile bone shaft. In Group 3, the fixation was similar to that in Group 2, but tile ascending K wires were introduced below the osteotomy level, crossing the osteotonly. Mechanical tests in bending-compression and torsion were used to access the stability. Findings. The torsional relative stiffness was 116% greater for Group 3 (0.27 N m/degree) and no significant difference was found between Group 1 (0.10 N m/degree) and Group 2 (0.12 N m/degree). The average torque was 103% higher for Group 3 (1.86 N m). Stiffness in bending-compression was significantly higher in Group 3 (508 x 10(3) N/m) than in Group 1 (211 x 10(3) N/m) and Group 2 (219 x 10(3) N/m). Interpretation. Fixation as used in Group 3 was significantly more stable, both in torsion and bending-compression tests, than tile other two techniques. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background-Puncture of the atrial appendage may provide access to the pericardial space. The aim of this study was to evaluate the feasibility of epicardial mapping and ablation through an endocardial transatrial access in a swine model. Methods and Results-An 8-F Mullins sheath was used to perforate the right (n=16) or left (n=1) atrial appendage in 17 pigs (median weight, 27.5 kg; first and third quartiles [Q1, Q3], 25.2, 30.0 kg). A 7-F ablation catheter was introduced into the pericardial space to perform epicardial mapping and deliver radiofrequency pulses on the atria. The pericardial space was entered in all 17 animals. In 15 (88%) animals, there was no hemodynamic instability (mean blood pressure monitoring, initial median, 80 mm Hg; Q1, Q3, 70, 86 mm Hg; final median, 88 mm Hg; Q1, Q3, 80, 96 mm Hg; P=0.426). In these 15, a mild hemorrhagic pericardial effusion was identified and aspirated (median, 20 mL; Q1, Q3, 15, 30 mL) during the procedure, and postmortem gross analysis revealed that the atrial perforation was closed in these animals. In 2 (12%) of the 17 animals, there was major pericardial bleeding with hemodynamic collapse. On gross examination, it was found that pericardial space was accessed through right ventricular perforation in 1 animal and the tricuspid annulus in the other. After the initial study, we used an occlusion device in 3 other animals to attempt to seal the puncture (2 at the right atrial appendage and 1 at the right ventricle). These 3 animals had no significant pericardial bleeding. Conclusions-Transatrial endovascular right atrial appendage puncture may provide a potential alternative route for pericardial access. Further studies are needed to evaluate its safety with longer and more-complex procedures before being applied in clinical settings. (Circ Arrhythm Electrophysiol. 2011;4:331-336.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Reports of iatrogenic thermal injuries during laparoscopic surgery using new generation vessel-sealing devices, as well as anecdotal reports of hand burn injuries during hand-assisted surgeries, have evoked questions about the temperature safety profile and the cooling properties of these instruments. Methods This study involved video recording of temperatures generated by different instruments (Harmonic ACE [ACE], Ligasure V [LV], and plasma trisector [PT]) applied according the manufacturers` pre-set settings (ACE setting 3; LV 3 bars, and the PT TR2 50W). The video camera used was the infrared Flex Cam Pro directed to three different types of swine tissue: (1) peritoneum (P), (2) mesenteric vessels (MV), and (3) liver (L). Activation and cooling temperature and time were measured for each instrument. Results The ACE device produced the highest temperatures (195.9 degrees +/- 14.5 degrees C) when applied against the peritoneum, and they were significantly higher than the other instruments (LV = 96.4 degrees +/- 4.1 degrees C, and PT = 87 degrees +/- 2.2 degrees C). The LV and PT consistently yielded temperatures that were < 100 degrees C independent of type of tissue or ""on""/ ""off"" mode. Conversely, the ACE reached temperatures higher than 200 degrees C, with a surprising surge after the instrument was deactivated. Moreover, temperatures were lower when the ACE was applied against thicker tissue (liver). The LV and PT cooling times were virtually equivalent, but the ACE required almost twice as long to cool. Conclusions The ACE increased the peak temperature after deactivation when applied against thick tissue (liver), and the other instruments inconsistently increased peak temperatures after they were turned off, requiring few seconds to cool down. Moreover, the ACE generated very high temperatures (234.5 degrees C) that could harm adjacent tissue or the surgeon`s hand on contact immediately after deactivation. With judicious use, burn injury from these instruments can be prevented during laparoscopic procedures. Because of the high temperatures generated by the ACE device, particular care should be taken when it is used during laparoscopy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One hundred and fifty-one Erysipelothrix spp. isolates from diseased and carrier swine from Brazil were identified by PCR, submitted to serotyping and analyzed by amplified fragment length polymorphism with a single enzyme (AFLP). Reference strains from Australia and the United Kingdom were also examined. The 151 strains were classified into 18 different serotypes (1a, 1b, 2a, 2b, 4, 5, 6, 7, 8, 10, 11, 12, 15, 17, 19, 21, 24 and 25), being serotype 2b the most frequent (39.7%). By associating serotyping and PCR results, it was possible to identify 146 strains as E. rhusiopathiae and five strains as E. tonsillarum. Despite the fact that for this genus AFLP did not cluster all isolates according to serotype, origin, disease or isolation data, the execution of the technique was easy and fast, demonstrating high discriminatory power. The results produced by the AFLP analysis of Erysipelothrix spp. could also support its use as a discriminatory tool for E. rhusiopathiae and E. tonsillarum species. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the effects of reversible meiotic inhibition and different culture media (PZM3 or NCSU23) on production of porcine embryos by either in vitro fertilization (IVF) or parthenogenetic activation (PA). Oocytes from abattoir-derived ovaries were allocated into two groups for maturation: CHX (5 mu g/ml cycloheximide for 10 h) or Control (no CHX). The percentage of metaphase II (MII) oocytes was determined at 36, 40 or 44 h of in vitro maturation. For IVF and PA, denuded oocytes were fertilized with purified sperm for 6 h or activated by electric stimuli. Zygotes were then subdivided into two culture groups: NCSU23 or PZM3. No effect of treatment with CHX and culture media was observed on cleavage (D3) and blastocyst (D7) rates in IVF and PA groups. There are no differences of quality or development rates between IVF-derived embryos cultured in NCSU23 or PZM3. However, we observed high quality PA embryos in PZM3 compared with NCSU23. Maturation arrest with CHX decreased the average blastocyst cell number in IVF while it was increased in PA embryos. As older oocytes are more effectively activated, CHX-blocked oocytes reached the mature stage faster than the control group. In conclusion, the CHX treatment for 10 h, followed by oocyte maturation for 40 h, is an efficient protocol to produce high quality parthenote embryos, especially when they are cultured in PZM3. However, this protocol is not satisfactory for IVF embryos production. In this case, a shorter maturation period could provide better embryo quality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe the genomic organization of a recently identified CC chemokine, MIP3 alpha /CCL20 (HGMW-approved symbol SCYA20). The MIP-3 alpha /CCL20 gene was cloned and sequenced, revealing a four exon, three intron structure, and was localized by FISK analysis to 2q35-q36. Two distinct cDNAs were identified, encoding two forms of MIP-3 alpha /CCL20, Ala MLP-3 alpha /CCL20 and Ser MIP-3 alpha /CCL20, that differ by one amino acid at the predicted signal peptide cleavage site. Examination of the sequence around the boundary of intron 1 and exon 2 showed that use of alternative splice acceptor sites could give rise to Ata MIP-3 alpha /CCL20 or Ser MIP-3 alpha /CCL20. Both forms of MIP-3cr/CCL20 were chemically synthesized and tested for biological activity. Both flu antigen plus IL-a-activated CD4(+) and CD8(+) T lymphoblasts and cord blood-derived dendritic cells responded to Ser and Ala MIP-3 alpha /CCL20. T lymphocytes exposed only to IL-2 responded inconsistently, while no response was detected in naive T lymphocytes, monocytes, or neutrophils. The biological activity of Ser MIP-3 alpha /CCL20 and Ala MIP-3 alpha /CCL20 and the tissue-specific preference of different splice acceptor sites are not yet known. (C) 2001 Academic Press.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cobalamins are stored in high concentrations in the human liver and thus are available to participate in the regulation of hepatotropic virus functions. We show that cyanocobalamin (vitamin B12) inhibited the H(IV internal ribosome entry site (IRES)-dependent translation of a reporter gene in vitro in a dose-dependent manner without significantly affecting the cap-dependent mechanism. Vitamin B12 failed to inhibit translation by IRES elements from encephalomyocarditis virus (EMCV) or classical swine fever virus (CSFV), We also demonstrate a relationship between the total cobalamin concentration in human sera and HCV viral load (a measure of viral replication in the host), The mean viral load was two orders of magnitude greater when the serum cobalamin concentration was above 200 pM (P < 0.003), suggesting that the total cobalamin concentration in an HCV-infected liver is biologically significant in HCV replication.