985 resultados para similar tests
Resumo:
Compliant foams are usually characterized by a wide range of desirable mechanical properties. These properties include viscoelasticity at different temperatures, energy absorption, recoverability under cyclic loading, impact resistance, and thermal, electrical, acoustic and radiation-resistance. Some foams contain nano-sized features and are used in small-scale devices. This implies that the characteristic dimensions of foams span multiple length scales, rendering modeling their mechanical properties difficult. Continuum mechanics-based models capture some salient experimental features like the linear elastic regime, followed by non-linear plateau stress regime. However, they lack mesostructural physical details. This makes them incapable of accurately predicting local peaks in stress and strain distributions, which significantly affect the deformation paths. Atomistic methods are capable of capturing the physical origins of deformation at smaller scales, but suffer from impractical computational intensity. Capturing deformation at the so-called meso-scale, which is capable of describing the phenomenon at a continuum level, but with some physical insights, requires developing new theoretical approaches.
A fundamental question that motivates the modeling of foams is ‘how to extract the intrinsic material response from simple mechanical test data, such as stress vs. strain response?’ A 3D model was developed to simulate the mechanical response of foam-type materials. The novelty of this model includes unique features such as the hardening-softening-hardening material response, strain rate-dependence, and plastically compressible solids with plastic non-normality. Suggestive links from atomistic simulations of foams were borrowed to formulate a physically informed hardening material input function. Motivated by a model that qualitatively captured the response of foam-type vertically aligned carbon nanotube (VACNT) pillars under uniaxial compression [2011,“Analysis of Uniaxial Compression of Vertically Aligned Carbon Nanotubes,” J. Mech.Phys. Solids, 59, pp. 2227–2237, Erratum 60, 1753–1756 (2012)], the property space exploration was advanced to three types of simple mechanical tests: 1) uniaxial compression, 2) uniaxial tension, and 3) nanoindentation with a conical and a flat-punch tip. The simulations attempt to explain some of the salient features in experimental data, like
1) The initial linear elastic response.
2) One or more nonlinear instabilities, yielding, and hardening.
The model-inherent relationships between the material properties and the overall stress-strain behavior were validated against the available experimental data. The material properties include the gradient in stiffness along the height, plastic and elastic compressibility, and hardening. Each of these tests was evaluated in terms of their efficiency in extracting material properties. The uniaxial simulation results proved to be a combination of structural and material influences. Out of all deformation paths, flat-punch indentation proved to be superior since it is the most sensitive in capturing the material properties.
Resumo:
In the quest for a descriptive theory of decision-making, the rational actor model in economics imposes rather unrealistic expectations and abilities on human decision makers. The further we move from idealized scenarios, such as perfectly competitive markets, and ambitiously extend the reach of the theory to describe everyday decision making situations, the less sense these assumptions make. Behavioural economics has instead proposed models based on assumptions that are more psychologically realistic, with the aim of gaining more precision and descriptive power. Increased psychological realism, however, comes at the cost of a greater number of parameters and model complexity. Now there are a plethora of models, based on different assumptions, applicable in differing contextual settings, and selecting the right model to use tends to be an ad-hoc process. In this thesis, we develop optimal experimental design methods and evaluate different behavioral theories against evidence from lab and field experiments.
We look at evidence from controlled laboratory experiments. Subjects are presented with choices between monetary gambles or lotteries. Different decision-making theories evaluate the choices differently and would make distinct predictions about the subjects' choices. Theories whose predictions are inconsistent with the actual choices can be systematically eliminated. Behavioural theories can have multiple parameters requiring complex experimental designs with a very large number of possible choice tests. This imposes computational and economic constraints on using classical experimental design methods. We develop a methodology of adaptive tests: Bayesian Rapid Optimal Adaptive Designs (BROAD) that sequentially chooses the "most informative" test at each stage, and based on the response updates its posterior beliefs over the theories, which informs the next most informative test to run. BROAD utilizes the Equivalent Class Edge Cutting (EC2) criteria to select tests. We prove that the EC2 criteria is adaptively submodular, which allows us to prove theoretical guarantees against the Bayes-optimal testing sequence even in the presence of noisy responses. In simulated ground-truth experiments, we find that the EC2 criteria recovers the true hypotheses with significantly fewer tests than more widely used criteria such as Information Gain and Generalized Binary Search. We show, theoretically as well as experimentally, that surprisingly these popular criteria can perform poorly in the presence of noise, or subject errors. Furthermore, we use the adaptive submodular property of EC2 to implement an accelerated greedy version of BROAD which leads to orders of magnitude speedup over other methods.
We use BROAD to perform two experiments. First, we compare the main classes of theories for decision-making under risk, namely: expected value, prospect theory, constant relative risk aversion (CRRA) and moments models. Subjects are given an initial endowment, and sequentially presented choices between two lotteries, with the possibility of losses. The lotteries are selected using BROAD, and 57 subjects from Caltech and UCLA are incentivized by randomly realizing one of the lotteries chosen. Aggregate posterior probabilities over the theories show limited evidence in favour of CRRA and moments' models. Classifying the subjects into types showed that most subjects are described by prospect theory, followed by expected value. Adaptive experimental design raises the possibility that subjects could engage in strategic manipulation, i.e. subjects could mask their true preferences and choose differently in order to obtain more favourable tests in later rounds thereby increasing their payoffs. We pay close attention to this problem; strategic manipulation is ruled out since it is infeasible in practice, and also since we do not find any signatures of it in our data.
In the second experiment, we compare the main theories of time preference: exponential discounting, hyperbolic discounting, "present bias" models: quasi-hyperbolic (α, β) discounting and fixed cost discounting, and generalized-hyperbolic discounting. 40 subjects from UCLA were given choices between 2 options: a smaller but more immediate payoff versus a larger but later payoff. We found very limited evidence for present bias models and hyperbolic discounting, and most subjects were classified as generalized hyperbolic discounting types, followed by exponential discounting.
In these models the passage of time is linear. We instead consider a psychological model where the perception of time is subjective. We prove that when the biological (subjective) time is positively dependent, it gives rise to hyperbolic discounting and temporal choice inconsistency.
We also test the predictions of behavioral theories in the "wild". We pay attention to prospect theory, which emerged as the dominant theory in our lab experiments of risky choice. Loss aversion and reference dependence predicts that consumers will behave in a uniquely distinct way than the standard rational model predicts. Specifically, loss aversion predicts that when an item is being offered at a discount, the demand for it will be greater than that explained by its price elasticity. Even more importantly, when the item is no longer discounted, demand for its close substitute would increase excessively. We tested this prediction using a discrete choice model with loss-averse utility function on data from a large eCommerce retailer. Not only did we identify loss aversion, but we also found that the effect decreased with consumers' experience. We outline the policy implications that consumer loss aversion entails, and strategies for competitive pricing.
In future work, BROAD can be widely applicable for testing different behavioural models, e.g. in social preference and game theory, and in different contextual settings. Additional measurements beyond choice data, including biological measurements such as skin conductance, can be used to more rapidly eliminate hypothesis and speed up model comparison. Discrete choice models also provide a framework for testing behavioural models with field data, and encourage combined lab-field experiments.
Resumo:
Neste trabalho, dois copolímeros à base de 2-vinilpiridina (2Vpy), estireno (Sty) e divinilbenzeno (DVB) foram sintetizados empregando a técnica de polimerização em suspensão aquosa via radical livre. Os copolímeros com diferentes características morfológicas foram preparados variando a composição da mistura diluente, constituída por tolueno e n-heptano, solventes solvatantes e não solvatantes para as cadeias poliméricas. A caracterização estrutural desses materiais foi feita através de medidas de área específica, volume de poros, diâmetro médio de poros e densidade aparente. Além disso, esses materiais foram avaliados por microscopia ótica e eletrônica de varredura, por espectroscopia na região do infravermelho (FTIR), análise termogravimétrica (TGA) e análise elementar. Os copolímeros Sty-DVB-2Vpy foram modificados quimicamente através de reação de quaternização das unidades de 2Vpy usando dois reagentes: iodeto de metila e acrilonitrila. A quaternização dos copolímeros Sty-DVB-2Vpy foi confirmada através de espectroscopia de infravermelho, pelo aparecimento das bandas de absorção características do íon peridíneo e do grupo nitrila e também pela análise do comportamento térmico. Os produtos dessas reações foram submetidos à avaliação da capacidade bactericida através do método de contagem em placas contra suspensão de Escherichia coli. O copolímero do tipo gel quaternizado com iodeto de metila apresentou a maior ação bactericida registrada, com eficiência até a concentração de 104 células/mL. Contudo, a maioria dos materiais quaternizados não apresentou ação biocida significativa. Com o objetivo de maximizar a atividade bactericida dos materiais preparados, os copolímeros quaternizados e não quaternizados foram impregnados com iodo por meio de duas metodologias: em solução e em fase vapor. O teor de iodo incorporado foi quantificado por análise gravimétrica. Foi possível observar que os copolímeros quaternizados e impregnados com iodo se mostraram mais eficientes como agentes bactericidas que os copolímeros não funcionalizados impregnados com iodo. De uma forma geral, foi possível perceber que a ação bactericida dos polímeros é fruto da associação entre as suas características de porosidade, o grau de quaternização alcançado e o teor de iodo incorporado. Para efeito de comparação foram feitos também ensaios bactericidas com uma resina comercial à base de Sty-DVB com grupo amônio quaternário, VP OC 1950. Os testes mostraram que a resina comercial não possui atividade bactericida. A impregnação de iodo a essa resina comercial forneceu um material com ação biocida semelhante à do copolímero do tipo gel, quaternizado com iodeto de metila e impregnado com iodo
Resumo:
A Periodontite e a Síndrome Metabólica (SM) podem estar associadas com inflamações sistêmicas e resistência insulínica, e assim as duas condições poderiam estar interrelacionadas. O objetivo deste estudo foi investigar a condição periodontal de pacientes não diabéticos com a SM, e avaliar sua relação com os valores dos componentes metabólicos da SM. Foram selecionados 165 pacientes não diabéticos com SM, 135 dentados (31 homens e 104 mulheres) entre 30 e 82 anos e 30 edentados. Sessenta e quatro pacientes não diabéticos e sem SM foram divididos em dois grupos: grupo saudável periodontalmente e grupo com Periodontite Severa. A avaliação da SM foi baseada nos critérios definidos pela Federação Internacional de Diabetes em 2005. Excluindo os edentados do grupo de pacientes com SM, 14,8% pacientes eram saudáveis periodontalmente, 40,7% com Periodontite moderada e 44,4% com Periodontite Severa. Entre os marcadores sistêmicos do grupo com SM, somente o IMC do grupo com Periodontite não severa foi significativamente maior quando comparado ao grupo com Periodontite Severa e ao grupo desdentado. A extensão e severidade da doença periodontal nos pacientes com Periodontite Severa com ou sem SM eram semelhantes. Pacientes com Periodontite Severa e SM tinham valores médios de glicemia, circunferência da cintura, pressão arterial sistólica e IMC significativamente maiores do que os observados nos pacientes com Periodontite Severa sem SM. No grupo sem SM os pacientes com Periodontite Severa apresentaram valores de HDL e circunferência da cintura significativamente diferentes dos pacientes saudáveis periodontalmente. Concluindo,a Periodontite Severa em pacientes com a SM e sem o Diabetes apresenta um padrão semelhante a indivíduos sem a SM. Pacientes com Periodontite Severa sem diagnóstico de SM devem ser investigados para SM.
Resumo:
A dissertação trata do acesso aos serviços de alta complexidade, particularmente os exames diagnósticos e complementares, estudado entre usuários de planos de saúde privados que buscam atendimento e diagnóstico especializado. Desde a década de 80 o usuário do sistema público de saúde vem procurando a saúde suplementar. Contudo, afirmar que o acesso é garantido no domínio privado, através da contratação dos planos de saúde, é uma incerteza que rodeia a inspiração para esta pesquisa, que se justifica pela relevância de ações que possibilitem a melhora da qualidade regulatória dos planos de saúde, a partir do controle social de seus usuários. O objetivo geral é analisar as percepções do acesso aos exames de alta complexidade nos serviços de saúde privados entre usuários de planos de saúde. Os objetivos específicos são descrever as percepções dos usuários de planos de saúde acerca do acesso aos exames de alta complexidade; analisar as motivações dos usuários de planos de saúde privados para a realização de exames de alta complexidade através da rede privada de assistência; e analisar o nível de satisfação dos usuários de planos de saúde quanto ao acesso aos exames de alta complexidade. A metodologia é qualitativa-descritiva, onde a amostra foi de trinta usuários de planos de saúde, acima de 18 anos, selecionados no campo de estudo no ano de 2010. O cenário de estudo foi um laboratório privado de medicina diagnóstica no Rio de Janeiro. As técnicas de coleta de dados utilizadas foram formulário e entrevista individual estruturada. A análise do formulário foi realizada através de estatística descritiva, e as entrevistas através da análise de conteúdo temática-categorial. Os usuários de plano de saúde declararam que o acesso é garantido com facilidade para os exames de alta complexidade. Suas principais motivações para a realização desses exames na rede privada de assistência foram caracterizadas pela rapidez de atendimento, flexibilidade e facilidade de marcação pela internet, telefone ou pessoalmente no laboratório estudado, pronta entrega dos resultados, dificuldade e morosidade do atendimento do SUS, localização do prestador credenciado próxima de bairros residenciais ou do trabalho, resolutividade diagnóstica de imagem de excelência, possibilidade de escolha pelo usuário entre as modalidades aberta e fechada de ressonância magnética e tomografia computadorizada, além da densitometria óssea que foram facilmente acessíveis a todos os sujeitos da pesquisa. O nível de satisfação foi correspondido com a rapidez na realização dos exames em caráter eletivo e de urgência quase equiparados na escala de tempo de acordo com os usuários. Contudo, embora as notas de avaliação dos usuários quanto aos seus planos de saúde tenham sido altas, foram abordadas algumas dificuldades, tais como: prazos de validade dos pedidos médicos com datação prévia; solicitações de senhas de autorização pela operadora; burocracia nos procedimentos de agendamento; dificuldades de acesso para tratamentos como implantes, fisioterapia, RPG, pilates, home care, consultas de check up; negação de reembolsos; restrição de materiais cirúrgicos, em especial as próteses e órteses; e restrições específicas de grau para cirurgias de miopia. Conclui-se que o atendimento rápido dos exames de imagem de alto custo na amostra foi descrito como satisfatório, embora a percepção de rapidez possa variar em função do tipo de produto do plano de saúde privado contratado, com necessidade de melhoria regulatória em alguns aspectos pontuais da saúde suplementar.
Resumo:
The following work explores the processes individuals utilize when making multi-attribute choices. With the exception of extremely simple or familiar choices, most decisions we face can be classified as multi-attribute choices. In order to evaluate and make choices in such an environment, we must be able to estimate and weight the particular attributes of an option. Hence, better understanding the mechanisms involved in this process is an important step for economists and psychologists. For example, when choosing between two meals that differ in taste and nutrition, what are the mechanisms that allow us to estimate and then weight attributes when constructing value? Furthermore, how can these mechanisms be influenced by variables such as attention or common physiological states, like hunger?
In order to investigate these and similar questions, we use a combination of choice and attentional data, where the attentional data was collected by recording eye movements as individuals made decisions. Chapter 1 designs and tests a neuroeconomic model of multi-attribute choice that makes predictions about choices, response time, and how these variables are correlated with attention. Chapter 2 applies the ideas in this model to intertemporal decision-making, and finds that attention causally affects discount rates. Chapter 3 explores how hunger, a common physiological state, alters the mechanisms we utilize as we make simple decisions about foods.
Resumo:
Na Odontologia, ao se confeccionar peças restauradoras dentárias, pela técnica indireta, o processo mais rotineiramente empregado utiliza um modelo de gesso, obtido a partir de um molde de elastômero, tomado de um dente preparado. Vários fatores podem influenciar na boa precisão de ajustes destas peças como o escoamento do material de vazamento dentro da moldagem, a compatibilidade do material de vazamento com o da moldagem, o tempo de presa, a estabilidade dimensional, a resistência mecânica do material quando da separação moldagem/modelo, a resistência a abrasão e a fidelidade de reprodução de detalhes. Materiais foram introduzidos na odontologia para utilização na confecção de troquéis no intuito de minimizar as desvantagens do gesso, como baixa resistência a abrasão e ligeira expansão de presa. Dentre eles os troquéis metalizados e as resinas epóxicas, que tem vantagens em relação às propriedades mecânicas, porém o primeiro exige técnica demorada e de alto custo e o segundo apresenta contração. O presente trabalho se propõe a testar uma nova composição de poliéster insaturado com estireno adicionado ao carbonato de cálcio em diferentes proporções (10, 20, 30, 40, 50, 60 e 70%) e compará-la ao gesso tipo IV e a resina epoxídica com óxido de alumínio, através de ensaios mecânicos, de abrasão e de alteração dimensional, para avaliar a possibilidade de sua utilização como material de confecção de troquéis para a construção de restaurações indiretas. Para caracterização dos materiais foram feitas análises de espectrometria no infravermelho, Calorimetria de varredura diferencial, termogravimétrica e Microscopia eletrônica de varredura. O compósito a base de poliéster insaturado com 50% de carbonato de cálcio se mostrou viável para utilização como material para troquel. Quando comparado aos materiais de controle mostrou propriedades mecânicas próximas as da resina epoxídica e bem superiores ao gesso, resistência a abrasão superior ao gesso e inferior a resina epoxídica e alteração dimensional próxima a resina epoxídica e maior ao gesso. Sendo a formulação do poliéster/carbonato de cálcio apenas constituída de polímero, catalisador e carga, é possível melhorar a formulação modificando a carga e/ou acrescentando aditivos visando minimizar a contração de polimerização.
Resumo:
There is a constantly increasing collection of manufactured substances, whose effectiveness in the sustenance of ducks is under investigation. The author examines the effects of some substances already previously tested and also there were examined substances which had not hitherto been studied. The use of different supplements for late autumn fattening is studied through various experiments.
Resumo:
A utilização de testes de biocompatibilidade de materiais odontológicos é necessária para avaliar a segurança dos mesmos. Listerine é um enxaguatório comercial usado para a prevenção e tratamento da gengivite. O objetivo do estudo foi avaliar os efeitos citotóxico e genotóxico do Listerine em culturas de Escherichia coli e plasmídios. Na avaliação da citotoxicidade, culturas de E. coli AB1157 e BW9091 foram incubadas com Listerine (10, 50 e 100%) e o crescimento acompanhado pela densidade óptica (DO) em 600nm por 7 horas(h). Para avaliar a sobrevivência, culturas de E. coli AB1157, em fase exponencial, foram centrifugadas, ressuspensas em solução salina (NaCl 0,9%) e incubadas (1h, 37C) com Listerine (10, 50, 100%, 1h, 37 C). Alíquotas foram semeadas em placas de Petri contendo meio nutritivo nos tempos 0, 30 e 60 minutos e armazenadas em estufa bacteriológica (18h, 37 C). As unidades formadoras de colônias contadas e as frações de sobrevivência (FS) calculadas. Como controles, culturas tratadas salina ou etanol (21,6%). Para genotoxicidade, plasmídios pBSK foram incubados com Listerine (10, 50 e 100%) e com etanol (2,16%, 10,8% e 21,6%), associados ou não ao SnCl2(200g/mL, 30 minutos, temperatura ambiente), realizada eletroforese em gel de agarose (0,8%, 8V/cm), observados por transiluminação UV e obtido o percentual da forma superespiralada (%SE). Os resultados indicam que o enxaguatório Listerine foi capaz de inibir o crescimento bacteriano de culturas de E. coli na maior concentração utilizada. O enxaguatório, na maior concentração, diminuiu a sobrevivência das culturas bacterianas testadas. Listerine não modificou o perfil eletroforético do plasmídios, indicando ausência de efeito genotóxico e também foi capaz de proteger os plamídios da ação do SnCl2. Além disso, o etanol, na mesma concentração presente no Listerine, não alterou o perfil eletroforético dos plasmídios, sendo capaz de protegê-lo da ação do SnCl2. Os resultados indicaram que o Listerine apresentou efeito citotóxico em culturas de E. coli e ausência de potencial genotóxico em plamídios, sendo capaz de protegê-los, bem como o etanol, dos efeitos genotóxicos do SnCl2.
Resumo:
I. It was not possible to produce anti-tetracycline antibody in laboratory animals by any of the methods tried. Tetracycline protein conjugates were prepared and characterized. It was shown that previous reports of the detection of anti-tetracycline antibody by in vitro-methods were in error. Tetracycline precipitates non-specifically with serum proteins. The anaphylactic reaction reported was the result of misinterpretation, since the observations were inconsistent with the known mechanism of anaphylaxis and the supposed antibody would not sensitize guinea pig skin. The hemagglutination reaction was not reproducible and was extremely sensitive to minute amounts of microbial contamination. Both free tetracyclines and the conjugates were found to be poor antigens.
II. Anti-aspiryl antibodies were produced in rabbits using 3 protein carriers. The method of inhibition of precipitation was used to determine the specificity of the antibody produced. ε-Aminocaproate was found to be the most effective inhibitor of the haptens tested, indicating that the combining hapten of the protein is ε-aspiryl-lysyl. Free aspirin and salicylates were poor inhibitors and did not combine with the antibody to a significant extent. The ortho group was found to participate in the binding to antibody. The average binding constants were measured.
Normal rabbit serum was acetylated by aspirin under in vitro conditions, which are similar to physiological conditions. The extent of acetylation was determined by immunochemical tests. The acetylated serum proteins were shown to be potent antigens in rabbits. It was also shown that aspiryl proteins were partially acetylated. The relation of these results to human aspirin intolerance is discussed.
III. Aspirin did not induce contact sensitivity in guinea pigs when they were immunized by techniques that induce sensitivity with other reactive compounds. The acetylation mechanism is not relevant to this type of hypersensitivity, since sensitivity is not produced by potent acetylating agents like acetyl chloride and acetic anhydride. Aspiryl chloride, a totally artificial system, is a good sensitizer. Its specificity was examined.
IV. Protein conjugates were prepared with p-aminosalicylic acid and various carriers using azo, carbodiimide and mixed anhydride coupling. These antigens were injected into rabbits and guinea pigs and no anti-hapten IgG or IgM response was obtained. Delayed hypersensitivity was produced in guinea pigs by immunization with the conjugates, and its specificity was determined. Guinea pigs were not sensitized by either injections or topical application of p-amino-salicylic acid or p-aminosalicylate.
Resumo:
Tratamento restaurador atraumático tornou-se uma opção real para o tratamento da cárie dentária em saúde pública no Brasil. O presente estudo teve como objetivo avaliar durabilidade, resistência e eficácia de 70 restaurações em 31 alunos (entre 6 a 12 anos de idade na Escola Municipal Rotary, RJ - Brasil). Depois de CPO-D e ceo-exame de acordo com critérios da OMS, todos os alunos com selecionados receberam TRA com VITRO MOLAR - DFL, juntamente com instruções de saúde bucal. Os critérios de exclusão foram a presença de cavidades muito profundas e exposição pulpar, casos em que os alunos foram encaminhados para o Postos de Saúde Municipal. In vitro avaliou-se a influência do tempo de entrada em serviço e do tipo de cobertura protetora utilizada na resistência coesiva do Cimento de Ionômero de Vidro utilizado, por meio de ensaios de tração diametral. Confeccionou-se para o teste de tração diametral 6 espécimes para cada variante, 72 no total, com dimensões de 4 mm de diâmetro por 8 mm de comprimento, divididos entre os grupos: grupo1 sem protetor (controle); grupo2 vaselina sólida; grupo3 verniz para unhas. Realizou-se ensaios mecânicos em uma máquina universal de ensaios EMIC DL 500 MF, após a confecção e estocagem individual dos espécimes em potes plásticos contendo 5 ml de água deionizada, que formaram os subgrupos descritos a seguir: a - 20 minutos; b - 2 horas; c - 24 horas; d - 7 dias. Os dados obtidos foram tratados por ANOVA e por Student Newman-Keuls (p<0,05). Ao se avaliar a influência dos diferentes protetores de superfície no CIV utilizado no presente trabalho observou-se que, os protetores de superfície tiveram influência no comportamento do material (p=0,000), com o verniz para unhas mostrando um desempenho superior ao da vaselina sólida. Quanto ao tempo, não foi possível verificar ruptura do material no prazo de 20 minutos, pois os corpos de prova sofriam deformação elástica catastrófica não sendo adequado para a finalidade desejada. Os tempos de 24 horas e sete dias foram semelhantes entre si e diferentes do tempo de duas horas. As restaurações foram clinicamente avaliadas depois de 6, 12, e 24 meses após sua alocação. No total 72 restaurações foram realizadas em 31 escolares. Depois de seis meses, 5 restaurações fraturaram e 3 perderam algum material. Após 12 meses, oito restaurações foram perdidas e apenas 1 fraturou. Na avaliação após 24 meses, mais 12 restaurações foram perdidas e 3 perderam material. Não foram registradas lesões cariosas secundarias após esse período, mesmo quando as restaurações foram parcialmente perdidas. Clinicamente conclui-se que quando a técnica do TRA é bem indicada e aplicada corretamente pode haver uma redução significativa no número de dentes perdidos por lesões de cárie nos indivíduos que participaram do nosso estudo.
Resumo:
Este estudo teve por objetivo avaliar, in vitro, a influência do material de confecção das matrizes, traçando um perfil da conversão monomérica de um compósito micro-híbrido, além de avaliar qual dos materiais testados mais se assemelha a uma matriz de dentina. A avaliação foi feita através da análise do grau de conversão (GC). Foram confeccionadas 3 matrizes bipartidas, sendo estas de teflon negro, tefon branco e aço inoxidável, ambas com 10mm de diâmetro e 2 mm de profundidade. Para o grupo controle foi utilizado um incisivo central bovino, o qual teve sua face vestibular aplainada em uma lixadeira sob refrigeração constante, com o auxílio de uma lixa de carbeto de silício, número 800. Após, este dente foi preparado com uma broca diamantada número 2294 (KG Sorensen) em alta rotação, própria para a preparação de cavidades padronizadas para ensaios de laboratório, apresentando um limitador de penetração. Em seguida, com um motor de baixa rotação foi realizado o acabamento das paredes, obtendo-se uma cavidade de 2,0 mm de profundidade por 9,0 mm de diâmetro. Pela palatina desse dente, com uma broca carbide cilíndrica de numeração 2056 (KG Sorensen), fez-se uma penetração até se obter uma parede de dentina extremamente fina, porém sem que esta fosse rompida. Assim, com uma agulha, fez-se uma pequena perfuração no centro dessa dentina para que este instrumental servisse como um pino para remoção do corpo de prova de dentro da matriz de dente. Os corpos de prova (CP) foram obtidos a partir da inserção do compósito no interior da perfuração das matrizes em um único incremento e cobertos na superfície externa com uma matriz de poliéster mais uma lamínula de vidro. Os CP foram fotopolimerizados por 40 s pela fonte de luz halógena Optilux 501 (Demetron), com 500 mW/cm. Imediatamente após a polimerização, os corpos de prova eram submetidos no topo e na base para a análise de espectrometria no infravermelho para a determinação da profundidade de polimerização, pela técnica do filme vazado para o compósito não polimerizado e pela técnica da pastilha de brometo de potássio (KBr) para o compósito polimerizado. Foram confeccionados 5 CP de cada grupo. Em cada grupo, o compósito da base e do topo das amostras foi moído até se obter de 1,5 a 2,0 mg de pó e misturado com 70 mg de KBr, para obtenção da pastilha de KBr. Foi feita a análise de espectrofotometria no infravermelho por Transformada de Fourier (FTIR). As absorções selecionadas para o cálculo foram 1610 cm-1 e 1637 cm-1, os picos dos espectros das ligações dos carbonos aromáticos e alifáticos, respectivamente. Os dados obtidos foram tratados estatisticamente. Os grupos Gr1B, Gr2B, Gr3B e Gr4B representam, respectivamente, as bases dos CP confeccionados pelas matrizes de DB, TN, TB e AI. Já os Gr1T, Gr2T, Gr3T e Gr4T representam os topos. Médias (%) e DP: Gr1T (46,461,99), Gr2T (39,864,51), Gr3T (44,053,44) e Gr4T (38,045,08). Gr1B (40,441,49), Gr2B (36,153,81), Gr3B (40,093,18) e Gr4B (35,593,35). Em posse dos resultados, pôde-se concluir que os grupos do teflon negro, teflon branco e aço inoxidável não apresentaram diferenças entre o grau de conversão do topo e da base, enquanto que o grupo da dentina apresentou maior conversão do topo. Comparando as matrizes entre elas, pôde-se perceber que no topo, o GC do dente bovino é maior que o GC do aço inoxidável e do que o de teflon negro, o GC do teflon branco é maior que o GC do aço inoxidável e do que o de teflon negro. Já o topo dos grupos de dente bovino e teflon banco foram semelhantes. Nas bases dos CPs, não houve diferença significativa entre os grupos testados. De acordo com os resultados obtidos no experimento, pôde-se concluir que nos grupos do teflon negro, teflon branco e aço inoxidável não houve diferença entre 0 e 2 mm, ou seja, topo e base, o que mostra que o material de confecção da matriz não influênciou o grau de conversão do compósito. Já para o grupo da matriz de dentina, o topo apresentou valor de conversão monomérica maior, mostrando que, neste caso, o material da matriz interferiu no grau de conversão. Pode-se perceber também que existe uma tendência da matriz de teflon branco se assemelhar mais a matriz de dentina, pois foi o único grupo que apresentou semelhança nos valores de conversão monomérica no topo das amostras. Porém analisando a base das amostras, percebe-se que todos os grupos se comportaram de forma semelhante, obtendo valores do grau de conversão sem diferença significante.
Resumo:
Avaliou-se a influência de dois sistemas de acabamento e polimento na resistência à flexão de uma cerâmica feldspática EX-3 (Noritake). Para isto, confeccionou-se blocos cerâmicos com medidas em conformidade com a ISO 6872/1995. Em seguida obteve-se o glaze natural. A padronização da rugosidade superficial foi conferida com auxílio de um rugosímetro, e os blocos foram então divididos em cinco grupos. O Grupo I (controle) foi testado com glaze. Para os testes realizados nos demais grupos, os blocos receberam um tratamento de asperização por meio de uma ponta diamantada 4137 (KG Sorensen). Em seguida foram polidos com diferentes protocolos. No grupo II, o sistema de polimento dura white (Shofu). No grupo III, o sistema de polimento dura white (shofu) associado a uma pasta diamantada aplicada com disco de feltro. No grupo IV o sistema de polimento Exa Cerapol (Edenta) e no grupo V, este mesmo sistema mais pasta diamantada aplicada com disco de feltro. Após os procedimentos de acabamento e polimento, foi avaliada a rugosidade conseguida (Ra), para se avaliar a eficácia dos métodos testados. A análise estatística por ANOVA (p ≤ 0,05) mostrou não haver diferença estatisticamente significante entre os grupos (G2=3,820,58; G3=3,550,61; G4=4,050,40; G5=3,950.47) . Feito isto, os corpos-de-prova foram submetidos a um ensaio mecânico de resistência à flexão em três pontos, e também neste caso, os resultados depois de tratados estatisticamente não demonstraram diferenças estatísticas entre os grupos glazeados e os grupos que receberam tratamento (G1=132,126,9 MPa; G2=123,317,4 MPa; G3=114,519,3 MPa; G4=104,211,9 MPa e G5=104,719,1 MPa) . Após a realização destas avaliações, tornou-se possível concluir que o uso dos sistemas de acabamento e polimento testados neste trabalho permite obter superfícies com rugosidade similar a obtida com o glaze natural e não interferem na resistência à flexão da cerâmica utilizada.