957 resultados para second generation leptoquarks


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Immunoglobulin E (IgE) mediates the immune response to parasites, but can also cause allergies. In humans maternal IgE is not transferred to cord blood and high levels of cord blood IgE are associated with subsequent allergy. In horses, both maternal IgG and IgE are transferred via colostrum; the IgE levels in the mare's serum, the colostrum and the foal's serum are correlated but the consequences of IgE transfer to foals are not known. By about 6 weeks of age the levels of IgE in foal serum have dropped to a nadir, at 6 months of age the level of IgE has risen only very slightly and is no longer correlated with the levels seen at birth, IgE(+) B-cells could be detected in lymphoid follicles of some foals at this age. Surprisingly, the levels of total IgE detected in a foals serum at 6 months of age are significantly correlated with the level in its serum at 1, 2 and even 3 years of age suggesting that by 6 months of age the foals are synthesizing IgE and that a pattern of relatively higher or lower total serum IgE has been established. The neonatal intestinal mucosa contained connective tissue mast cells which stained for bound IgE in foals up to 9 weeks of age but not mucosal mast cells, thereafter, the intestinal mast cells were IgE negative until 6 months of age. IgE antibodies to Culicoides nubeculosus salivary antigens were detected in Swiss born foals from imported Icelandic mares allergic to Culicoides spp. yet the foals showed no signs of skin sensitization and such second generation foals are known not to have an increased risk of developing allergy to Culicoides. Overall this evidence suggests there is a minimal effector role of maternal IgE also that maternal IgE has waned prior to the onset of IgE synthesis in foals and does not support maternal priming of IgE responses in foals. Furthermore the total levels of IgE in any given foal are seen to be relatively high or low from soon after the onset of IgE synthesis, and most likely they are determined by genetic factors.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES The aim of this study was to investigate micromechanical properties of five dual-curing resin cements after different curing modes including light curing through glass ceramic materials. MATERIALS AND METHODS Vickers hardness (VH) and indentation modulus (Y HU) of Panavia F2.0, RelyX Unicem 2 Automix, SpeedCEM, BisCem, and BeautiCem SA were measured after 1 week of storage (37 °C, 100 % humidity). The resin cements were tested following self-curing or light curing with the second-generation light-emitting diode (LED) curing unit Elipar FreeLight 2 in Standard Mode (1,545 mW/cm(2)) or with the third-generation LED curing unit VALO in High Power Mode (1,869 mW/cm(2)) or in XtraPower Mode (3,505 mW/cm(2)). Light curing was performed directly or through glass ceramic discs of 1.5 or 3 mm thickness of IPS Empress CAD or IPS e.max CAD. VH and Y HU were analysed with Kruskal-Wallis tests followed by pairwise Wilcoxon rank sum tests (α = 0.05). RESULTS RelyX Unicem 2 Automix resulted in the highest VH and Y HU followed by BeautiCem SA, BisCem, SpeedCEM, and finally Panavia F2.0. Self-curing of RelyX Unicem 2 Automix and SpeedCEM lowered VH and Y HU compared to light curing whereas self-curing of Panavia F2.0, BisCem, and BeautiCem SA led to similar or significantly higher VH and Y HU compared to light curing. Generally, direct light curing resulted in similar or lower VH and Y HU compared to light curing through 1.5-mm-thick ceramic discs. Light curing through 3-mm-thick discs of IPS e.max CAD generally reduced VH and Y HU for all resin cements except SpeedCEM, which was the least affected by light curing through ceramic discs. CONCLUSIONS The resin cements responded heterogeneously to changes in curing mode. The applied irradiances and light curing times adequately cured the resin cements even through 1.5-mm-thick ceramic discs. CLINICAL RELEVANCE When light curing resin cements through thick glass ceramic restorations, clinicians should consider to prolong the light curing times even with LED curing units providing high irradiances.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES This study sought to assess the clinical safety and effectiveness of the Resolute zotarolimus-eluting stent (R-ZES) in patients with in-stent restenosis (ISR) from 2 large trials. BACKGROUND ISR treatment is associated with higher rates of subsequent cardiac events compared with treatment of de novo lesions. Although drug-eluting stents (DES) are an option, second-generation DES are largely untested in the treatment of ISR. METHODS A total of 3,489 patients were pooled from the RAC (RESOLUTE All Comers) trial and the RESOLUTE International (RINT) registry. Two-year clinical endpoints included clinically driven target lesion revascularization (TLR), target lesion failure (TLF), cardiac death (CD), target vessel myocardial infarction (TVMI), combined CD or TVMI (CD/TVMI), and Academic Research Consortium definite and probable stent thrombosis (ST). RESULTS Overall, 281 patients (8.1%) received an R-ZES for ISR. Two-year TLR and TLF rates were significantly higher in ISR patients than in non-ISR patients (TLR: 12.7% vs. 4.3%, p = 0.003; TLF: 17.4% vs. 9.4%, p = 0.007); however, the CD/TVMI rate was not (6.9% vs. 6.1%, p = 0.711). Seven ISR patients had ST. Two-year outcomes by ISR stent type were similar: bare-metal stent (BMS)-ISR TLR was 12.5% and TLF was 17.2%; DES-ISR TLR was 13.0% and TLF was 18.8%. CD/TVMI was 7.3% and 7.2% for BMS-ISR and DES-ISR, respectively. CONCLUSIONS Using R-ZES to treat ISR appears equally safe in BMS-ISR and DES-ISR, with CD/TVMI rates comparable to 2-year outcomes in other clinical trials. Although revascularization rates are still higher in ISR lesions, the R-ZES offers an effective alternative for treatment of BMS-ISR and DES-ISR. (Randomized, Two-Arm, Non-inferiority Study Comparing Endeavor-Resolute Stent With Abbot Xience-V Stent [RESOLUTE-AC]; NCT00617084; and RESOLUTE International Registry: Evaluation of the Resolute Zotarolimus-Eluting Stent System in a 'Real-World' Patient Population [RINT]; NCT00752128).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE We investigated clinical outcomes after treatment of coronary bifurcation lesions with second generation drug eluting stents (DES). DESIGN Post hoc analysis of a randomised, multicentre, non-inferiority trial. SETTING Multicentre study. PATIENTS All comers study with minimal exclusion criteria. INTERVENTIONS Patients were treated with either zotarolimus or everolimus eluting stents. The patient population was divided according to treatment of bifurcation or non-bifurcation lesions and clinical outcomes were compared between groups. MAIN OUTCOMES MEASURES Clinical outcomes within 2-year follow-up. RESULTS A total of 2265 patients were included in the present analysis. Two-year follow-up data were available in 2223 patients: 1838 patients in the non-bifurcation group and 385 patients in the bifurcation group. At 2-year follow-up the bifurcation and the non-bifurcation lesion groups showed no significant differences in terms of cardiac death (2.3 vs 2.1, p=0.273), target lesion failure (9.7% vs 13.8%, p=0.255), major adverse cardiac events (11.5% vs 15.1%, p=0.305), target lesion revascularisation (4.7% vs 6.0%, p=0.569), and definite or probable stent thrombosis (1.6% vs 1.8%, p=0.419). CONCLUSIONS The use of second generation DES for the treatment of coronary bifurcation lesions was associated with similar long term mortality and clinical outcomes compared with non-bifurcation lesions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND The long-term results after second generation everolimus eluting bioresorbable vascular scaffold (Absorb BVS) placement in small vessels are unknown. Therefore, we investigated the impact of vessel size on long-term outcomes, after Absorb BVS implantation. METHODS In ABSORB Cohort B Trial, out of the total study population (101 patients), 45 patients were assigned to undergo 6-month and 2-year angiographic follow-up (Cohort B1) and 56 patients to have angiographic follow-up at 1-year (Cohort B2). The pre-reference vessel diameter (RVD) was <2.5 mm (small-vessel group) in 41 patients (41 lesions) and ≥2.5 mm (large-vessel group) in 60 patients (61 lesions). Outcomes were compared according to pre-RVD. RESULTS At 2-year angiographic follow-up no differences in late lumen loss (0.29±0.16 mm vs 0.25±0.22 mm, p=0.4391), and in-segment binary restenosis (5.3% vs 5.3% p=1.0000) were demonstrated between groups. In the small-vessel group, intravascular ultrasound analysis showed a significant increase in vessel area (12.25±3.47 mm(2) vs 13.09±3.38 mm(2) p=0.0015), scaffold area (5.76±0.96 mm(2) vs 6.41±1.30 mm(2) p=0.0008) and lumen area (5.71±0.98 mm(2) vs 6.20±1.27 mm(2) p=0.0155) between 6-months and 2-year follow-up. No differences in plaque composition were reported between groups at either time point. At 2-year clinical follow-up, no differences in ischaemia-driven major adverse cardiac events (7.3% vs 10.2%, p=0.7335), myocardial infarction (4.9% vs 1.7%, p=0.5662) or ischaemia-driven target lesion revascularisation (2.4% vs 8.5%, p=0.3962) were reported between small and large vessels. No deaths or scaffold thrombosis were observed. CONCLUSIONS Similar clinical and angiographic outcomes at 2-year follow-up were reported in small and large vessel groups. A significant late lumen enlargement and positive vessel remodelling were observed in small vessels.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE The Coherex-EU Study evaluated the safety and efficacy of PFO closure utilizing novel in-tunnel PFO closure devices. BACKGROUND Transcatheter closure of patent foramen ovale (PFO) followed the development of transcatheter closure devices designed to patch atrial septal defects (ASDs). The Coherex FlatStent™ and FlatStent™ EF devices were designed specifically to treat PFO anatomy. METHODS A total of 95 patients with a clinical indication for PFO closure were enrolled in a prospective, multicenter first in man study at six clinical sites. Thirty-six patients received the first-generation FlatStent study device, and 57 patients received the second-generation FlatStent EF study device, which was modified based on clinical experience during the first 38 cases. Two patients enrolled to receive the first generation did not receive a device. RESULTS At 6 months post-procedure, 45% (17/38) of the intention-to-treat (ITT) cohort receiving the first-generation FlatStent device had complete closure, 26% (10/38) had a trivial residual shunt, and 29% (11/38) had a moderate to large residual shunt. In the ITT cohort receiving the second-generation FlatStent EF device, 76% (43/57) had complete closure, 12% (7/57) had a trivial shunt, and 12% had a moderate to large shunt. Five major adverse events occurred, all without sequelae. CONCLUSION This initial study of the Coherex FlatStent/FlatStent EF PFO Closure System demonstrated the potential for in-tunnel PFO closure. The in-tunnel Coherex FlatStent EF may offer an alternative to septal repair devices for PFO closure in appropriately selected patients; however, further investigation will be necessary to establish the best use of this device.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The process of adaptive radiation involves multiple events of speciation in short succession, associated with ecological diversification. Understanding this process requires identifying the origins of heritable phenotypic variation that allows adaptive radiation to progress. Hybridization is one source of genetic and morphological variation that may spur adaptive radiation. We experimentally explored the potential role of hybridization in facilitating the onset of adaptive radiation. We generated first- and second-generation hybrids of four species of African cichlid fish, extant relatives of the putative ancestors of the adaptive radiations of Lakes Victoria and Malawi. We com- pared patterns in hybrid morphological variation with the variation in the lake radiations. We show that significant fractions of the interspecific mor- phological variation and the major trajectories in morphospace that charac- terize whole radiations can be generated in second-generation hybrids. Furthermore, we show that covariation between traits is relaxed in second- generation hybrids, which may facilitate adaptive diversification. These results support the idea that hybridization can provide the heritable pheno- typic diversity necessary to initiate adaptive radiation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Bovine viral diarrhoea virus (BVDV) is an economically important pathogen of cattle worldwide. Infection of a pregnant animal may lead to persistent infection of the foetus and birth of a persistently infected (PI) calf that sheds the virus throughout its life. However, BVD viruses are not strictly species specific. BVDV has been isolated from many domesticated and wild ruminants. This is of practical importance as virus reservoirs in non-bovine hosts may hamper BVDV control in cattle. A goat given as a social companion to a BVDV PI calf gave birth to a PI goat kid. In order to test if goat to goat infections were possible, seronegative pregnant goats were exposed to the PI goat. In parallel, seronegative pregnant goats were kept together with the PI calf. Only the goat to goat transmission resulted in the birth of a next generation of BVDV PI kids whereas all goats kept together with the PI calf aborted. To our knowledge, this is the first report which shows that a PI goat cannot only transmit BVD virus to other goats but that such transmission may indeed lead to the birth of a second generation of PI goats. Genetic analyses indicated that establishment in the new host species may be associated with step-wise adaptations in the viral genome. Thus, goats have the potential to be a reservoir for BVDV. However, the PI goats showed growth retardation and anaemia and their survival under natural conditions remains questionable.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Somatostatin analogs for the diagnosis and therapy of neuroendocrine tumors (NETs) have been used in clinical applications for more than two decades. Five somatostatin receptor subtypes have been identified and molecular mechanisms of somatostatin receptor signaling and regulation have been elucidated. These advances increased understanding of the biological role of each somatostatin receptor subtype, their distribution in NETs, as well as agonist-specific regulation of receptor signaling, internalization, and phosphorylation, particularly for the sst2 receptor subtype, which is the primary target of current somatostatin analog therapy for NETs. Various hypotheses exist to explain differences in patient responsiveness to somatostatin analog inhibition of tumor secretion and growth as well as differences in the development of tumor resistance to therapy. In addition, we now have a better understanding of the action of both first generation (octreotide, lanreotide, Octreoscan) and second generation (pasireotide) FDA-approved somatostatin analogs, including the biased agonistic character of some agonists. The increased understanding of somatostatin receptor pharmacology provides new opportunities to design more sophisticated assays to aid the future development of somatostatin analogs with increased efficacy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La présente contribution porte sur le passage dans le degré tertiaire en tenant compte de l’intrication des inégalités liées au sexe et au contexte migratoire. L’étude, qui repose sur des concepts de la théorie décisionnelle, s’articule principalement sur une comparaison entre la Suisse (TREE), l’Allemagne (élèves pouvant prétendre aux études supérieures 2002 HIS) et la France (Panel d'élèves du second degré 1995). Les résultats révèlent qu’en Suisse et en Allemagne, indépendamment de l’origine sociale, les jeunes hommes appartenant à certains groupes de migrants socialement défavorisés (2e génération) affichent un taux de passage dans le supérieur plus élevé que leurs camarades nationaux. Ils mettent par ailleurs en évidence que, ni en Suisse, ni en Allemagne, ni en France, les migrantes de deuxième génération issues de pays fortement marqués par le modèle patriarcal sont désavantagées.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pneumococcal meningitis (PM) results in high mortality rates and long-lasting neurological deficits. Hippocampal apoptosis and cortical necrosis are histopathological correlates of neurofunctional sequelae in rodent models and are frequently observed in autopsy studies of patients who die of PM. In experimental PM, inhibition of matrix metalloproteinases (MMPs) and/or tumor necrosis factor (TNF)-converting enzyme (TACE) has been shown to reduce brain injury and the associated impairment of neurocognitive function. However, none of the compounds evaluated in these studies entered clinical development. Here, we evaluated two second-generation MMP and TACE inhibitors with higher selectivity and improved oral availability. Ro 32-3555 (Trocade, cipemastat) preferentially inhibits collagenases (MMP-1, -8, and -13) and gelatinase B (MMP-9), while Ro 32-7315 is an efficient inhibitor of TACE. PM was induced in infant rats by the intracisternal injection of live Streptococcus pneumoniae. Ro 32-3555 and Ro 32-7315 were injected intraperitoneally, starting at 3 h postinfection. Antibiotic (ceftriaxone) therapy was initiated at 18 h postinfection, and clinical parameters (weight, clinical score, mortality rate) were recorded. Myeloperoxidase activities, concentrations of cytokines and chemokines, concentrations of MMP-2 and MMP-9, and collagen concentrations were measured in the cerebrospinal fluid. Animals were sacrificed at 42 h postinfection, and their brains were assessed by histomorphometry for hippocampal apoptosis and cortical necrosis. Both compounds, while exhibiting disparate MMP and TACE inhibitory profiles, decreased hippocampal apoptosis and cortical injury. Ro 32-3555 reduced mortality rates and cerebrospinal fluid TNF, interleukin-1β (IL-1β) and collagen levels, while Ro 32-7315 reduced weight loss and cerebrospinal fluid TNF and IL-6 levels.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

AIMS: Second-generation everolimus-eluting stents (EES) are safer and more efficient than first-generation paclitaxel-eluting stents (PES). Third-generation biolimus-eluting stents (BES) have been found to be non-inferior to PES. To date, there is no available comparative study between EES and BES. We aimed to investigate the safety and efficacy of BES with biodegradable polymer compared to EES with durable polymer at a follow-up of two years in an unselected population of consecutively enrolled patients. METHODS AND RESULTS: A group of 814 consecutive patients undergoing percutaneous coronary intervention (PCI) was enrolled between 2007 and 2010, of which 527 were treated with EES and 287 with BES implantation. Clinical outcome was compared in 200 pairs using propensity score matching. The primary endpoint was a composite of death, myocardial infarction (MI) and target vessel revascularisation (TVR) at two-year follow-up. Median follow-up was 22 months. The primary outcome occurred in 11.5% of EES and 10.5% of BES patients (HR 1.11, 95% CI: 0.61-2.00, p=0.74). At two years, there was no significant difference with regard to death (HR 0.49, 95% CI: 0.18-1.34, p=0.17), cardiac death (HR 0.14, 95% CI: 0.02-1.14, p=0.66) or MI (HR 6.10, 95% CI: 0.73-50.9, p=0.10). Stent thrombosis (ST) incidence was evenly distributed between EES (n=2) and BES (n=2) (p-value=1.0). CONCLUSIONS: This first clinical study failed to demonstrate any significant difference regarding safety or efficacy between these two types and generations of drug-eluting stents (DES).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Second-generation everolimus-eluting stents (EES) and third generation biolimus-eluting stents (BES) have been shown to be superior to first-generation paclitaxel-eluting stents (PES) and second-generation sirolimus-eluting stents (SES). However, neointimal proliferation and very late stent thrombosis is still an unresolved issue of drug-eluting stent (DES) implantation overall. The Absorb™ (Abbott Vascular, Abbott Park, IL, USA) is the first CE approved DES with a bioresorbable vascular scaffold (BVS) thought to reduce long-term complication rates. The EVERBIO II trial was set up to compare the BVS safety and efficacy with both EES and BES in all patients viable for inclusion. METHODS/DESIGN: The EVERBIO II trial is a single-center, assessor-blinded, randomized trial. The study population consists of all patients aged≥18 years old undergoing percutaneous coronary intervention. Exclusion criterion is where the lesion cannot be treated with BVS (reference vessel diameter>4.0 mm). A total of 240 patients will be enrolled and randomly assigned into 3 groups of 80 with either BVS, EES or BES implantation. All patients will undergo a follow-up angiography study at 9 months. Clinical follow-up for up to 5 years will be conducted by telephone. The primary endpoint is in-segment late lumen loss at 9 months measured by quantitative coronary angiography. Secondary endpoints are patient-oriented major adverse cardiac event (MACE) (death, myocardial infarction and target-vessel revascularization), device-oriented MACE (cardiac death, myocardial infarction and target-lesion revascularization), stent thrombosis according to ARC and binary restenosis at follow-up 12 months angiography. DISCUSSION: EVERBIO II is an independent, randomized study, aiming to compare the clinical efficacy, angiographic outcomes and safety of BVS, EES and BES in all comer patients. TRIAL REGISTRATION: The trial listed in clinicaltrials.gov as NCT01711931.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this study was to examine the success rate of paramedian palatal Orthosystem first- and second-generation implants used for anchorage in orthodontic treatment in patients treated by one experienced orthodontist. The records of 143 patients (90 female, 53 male, median age: 15.7 years, range: 10.2-50.9) receiving 145 palatal implants of the first or second generation (Orthosystem, Straumann AG, Basel, Switzerland) were examined. All the palatal implants were placed in a paramedian palatal location by three experienced surgeons. Stable implants were orthodontically loaded after a healing period of 3 months. Out of the 145 inserted paramedian palatal implants only seven implants (4.8%) were not considered stable after insertion. All the successfully osseointegrated implants remained stable during orthodontic treatment. Paramedian palatal implants are highly reliable and effective devices to obtain skeletal anchorage for orthodontic treatment. This study has shown that the paramedian location is a good alternative to the median location.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND Medial open wedge high tibial osteotomy is a well-established procedure for the treatment of unicompartmental osteoarthritis and symptomatic varus malalignment. We hypothesized that different fixation devices generate different fixation stability profiles for the various wedge sizes in a finite element (FE) analysis. METHODS Four types of fixation were compared: 1) first and 2) second generation Puddu plates, and 3) TomoFix plate with and 4) without bone graft. Cortical and cancellous bone was modelled and five different opening wedge sizes were studied for each model. Outcome measures included: 1) stresses in bone, 2) relative displacement of the proximal and distal tibial fragments, 3) stresses in the plates, 4) stresses on the upper and lower screw surfaces in the screw channels. RESULTS The highest load for all fixation types occurred in the plate axis. For the vast majority of the wedge sizes and fixation types the shear stress (von Mises stress) was dominating in the bone independent of fixation type. The relative displacements of the tibial fragments were low (in μm range). With an increasing wedge size this displacement tended to increase for both Puddu plates and the TomoFix plate with bone graft. For the TomoFix plate without bone graft a rather opposite trend was observed.For all fixation types the occurring stresses at the screw-bone contact areas pulled at the screws and exceeded the allowable threshold of 1.2 MPa for at least one screw surface. Of the six screw surfaces that were studied, the TomoFix plate with bone graft showed a stress excess of one out of twelve and without bone graft, five out of twelve. With the Puddu plates, an excess stress occurred in the majority of screw surfaces. CONCLUSIONS The different fixation devices generate different fixation stability profiles for different opening wedge sizes. Based on the computational simulations, none of the studied osteosynthesis fixation types warranted an intransigent full weight bearing per se. The highest fixation stability was observed for the TomoFix plates and the lowest for the first generation Puddu plate. These findings were revealed in theoretical models and need to be validated in controlled clinical settings.