954 resultados para perfusion-weighted MRI


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Devices for venous cannulation have seen significant progress over time: the original, rigid steel cannulas have evolved toward flexible plastic cannulas with wire support that prevents kinking, very thin walled wire wound cannulas allowing for percutaneous application, and all sorts of combinations. In contrast to all these rectilinear venous cannula designs, which present the same cross-sectional area over their entire intravascular path, the smartcanula concept of "collapsed insertion and expansion in situ" is the logical next step for venous access. Automatically adjusting cross-sectional area up to a pre-determined diameter or the vessel lumen provides optimal flow and ease of use for both, insertion and removal. Smartcanula performance was assessed in a small series of patients (76 +/- 17 kg) undergoing redo procedures. The calculated target pump flow (2.4 L/min/m2) was 4.42 +/- 61 L/ min. Mean pump flow achieved during cardiopulmonary bypass was 4.84 +/- 87 L/min or 110% of the target. Reduced atrial chatter, kink resistance in situ, and improved blood drainage despite smaller access orifice size, are the most striking advantages of this new device. The benefits of smart cannulation are obvious in remote cannulation for limited access cardiac surgery, but there are many other cannula applications where space is an issue, and that is where smart cannulation is most effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudi realitzat a partir d’una estada a la Stanford University School of Medicine. Division of Radiation Oncology, Estats Units, entre 2010 i 2012. Durant els dos anys de beca postdoctoral he estat treballant en dos projectes diferents. En primer lloc, i com a continuació d'estudis previs del grup, volíem estudiar la causa de les diferències en nivells d'hipòxia que havíem observat en models de càncer de pulmó. La nostra hipòtesi es basava en el fet que aquestes diferències es devien a la funcionalitat de la vasculatura. Vam utilitzar dos models preclínics: un en què els tumors es formaven espontàniament als pulmons i l'altre on nosaltres injectàvem les cèl•lules de manera subcutània. Vam utilitzar tècniques com la ressonància magnètica dinàmica amb agent de contrast (DCE-MRI) i l'assaig de perfusió amb el Hoeschst 33342 i ambdues van demostrar que la funcionalitat de la vasculatura dels tumors espontanis era molt més elevada comparada amb la dels tumors subcutanis. D'aquest estudi, en podem concloure que les diferències en els nivells d'hipòxia en els diferents models tumorals de càncer de pulmó podrien ser deguts a la variació en la formació i funcionalitat de la vasculatura. Per tant, la selecció de models preclínics és essencial, tant pels estudi d'hipòxia i angiogènesi, com per a teràpies adreçades a aquests fenòmens. L'altre projecte que he estat desenvolupant es basa en l'estudi de la radioteràpia i els seus possibles efectes a l’hora de potenciar l'autoregeneració del tumor a partir de les cèl•lules tumorals circulants (CTC). Aquest efecte s'ha descrit en alguns models tumorals preclínics. Per tal de dur a terme els nostres estudis, vam utilitzar una línia tumoral de càncer de mama de ratolí, marcada permanentment amb el gen de Photinus pyralis o sense marcar i vam fer estudis in vitro i in vivo. Ambdós estudis han demostrat que la radiació tumoral promou la invasió cel•lular i l'autoregeneració del tumor per CTC. Aquest descobriment s'ha de considerar dins d'un context de radioteràpia clínica per tal d'aconseguir el millor tractament en pacients amb nivells de CTC elevats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: We evaluated the potential for hybrid PET/MRI devices to provide integrated metabolic, functional and anatomic characterisation of patients with suspected coronary artery disease.Methods and Materials: Ten patients (5 with suspected hibernating myocardium and 5 healthy volunteers) performed an imaging study using a hybrid PET/MRI (Philips). Viability assessed by 18F-FDG was performed in diseased patients along with MRI anatomic and functional study and reassessed within 30 minutes by conventional PET/CT. Non-contrast right coronary artery (RCA) targeted and whole heart 3D coronary angio-MRI using ECG-gating and respiratory navigator was performed in healthy volunteers with reconstruction performed using MPR and volume rendering. The extent of metabolic defect (MD) using PET/MRI and PET/CT was compared in patients and coronary territories (LAD, CX, RCA). Assessability of coronary lumen was judged as good, sub-optimal or non-assessable using a 16-segments coronary model.Results: Metabolic assessment was successful in all patients with MD being 19.2% vs 18.3% using PET/MRI and PET/CT, respectively (P=ns). The MD was 10.2%, 6 %, and 3 % vs 9.3%, 6 % and 3 % for LAD, CX and RCA territories, respectively (P= ns). Coronary angio-MRI was successful in all volunteers with 66 coronary segments visualised overall. The RCA was fully visualised in 4/5 volunteers and the left coronary arteries in 4/5 volunteers. Assessability in visualised segments was good, sub-optimal and non-assessable in 88 %, 2 % and 10 %, respectively.Conclusion: Hybrid PET/MRI devices may enable metabolic evaluation comparable to PET/CT with additional value owing to accurate functional and anatomical information including coronary assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate accuracy and reproducibility of flow velocity and volume measurements in a phantom and in human coronary arteries using breathhold velocity-encoded (VE) MRI with spiral k-space sampling at 3 Tesla. MATERIALS AND METHODS: Flow velocity assessment was performed using VE MRI with spiral k-space sampling. Accuracy of VE MRI was tested in vitro at five constant flow rates. Reproducibility was investigated in 19 healthy subjects (mean age 25.4 +/- 1.2 years, 11 men) by repeated acquisition in the right coronary artery (RCA). RESULTS: MRI-measured flow rates correlated strongly with volumetric collection (Pearson correlation r = 0.99; P < 0.01). Due to limited sample resolution, VE MRI overestimated the flow rate by 47% on average when nonconstricted region-of-interest segmentation was used. Using constricted region-of-interest segmentation with lumen size equal to ground-truth luminal size, less than 13% error in flow rate was found. In vivo RCA flow velocity assessment was successful in 82% of the applied studies. High interscan, intra- and inter-observer agreement was found for almost all indices describing coronary flow velocity. Reproducibility for repeated acquisitions varied by less than 16% for peak velocity values and by less than 24% for flow volumes. CONCLUSION: 3T breathhold VE MRI with spiral k-space sampling enables accurate and reproducible assessment of RCA flow velocity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Measures of the degree of lumbar spinal stenosis (LSS) such as antero-posterior diameter of the canal, and dural sac cross sectional area vary, and do not correlate with symptoms or results of surgery. We created a grading system, comprised of seven categories, based on the morphology of the dural sac and its contents as seen on T2 axial images. The categories take into account the ratio of rootlet/ CSF content. Grade A indicates no significant compression, grade D is equivalent to a total myelograhic block. We compared this classification with commonly used criteria of severity of stenosis. Methods: Fifty T2 axial MRI images taken at disc level from 27 symptomatic LSS patients undergoing decompressive surgery were classified twice by two radiologists and three spinal surgeons working at different institutions and countries. Dural sac cross-sectional surface area and AP diameter of the canal were measured both at disc and pedicle level from DICOM images using OsiriX software. Intraand inter-observer reliability were assessed using Cohen's, Fleiss' kappa statistics, and t test. Results: For the morphological grading the average intra-and inter observer kappas were 0.76 and 0.69+, respectively, for physicians working in the study originating country. Combining all observers the kappa values were 0.57 ± 0.19. and 0.44 ± 0.19, respectively. AP diameter and dural sac cross-sectional area measurements showed no statistically significant differences between observers. No correlation between morphological grading and AP diameter or dural sac crosssectional areawas observed in 13 (26%) and 8 cases (16%), respectively. Discussion: The proposed morphological grading relies on the identification of the dural sac and CSF better seen on full MRI series. This was not available to the external observers, which might explain the lower overall kappa values. Since no specific measurement tools are needed the grading suits everyday clinical practice and favours communication of degree of stenosis between practising physicians. The absence of a strict correlation with the dural sac surface suggests that measuring the surface alone might be insufficient in defining LSS as it is essentially a mismatch between the spinal canal and its contents. This grading is now adopted in our unit and further studies concentrating on relation between morphology, clinical symptoms and surgical results are underway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High Resolution Magic Angle Spinning (HR-MAS) NMR allows metabolic characterization of biopsies. HR-MAS spectra from tissues of most organs show strong lipid contributions that are overlapping metabolite regions, which hamper metabolite estimation. Metabolite quantification and analysis would benefit from a separation of lipids and small metabolites. Generally, a relaxation filter is used to reduce lipid contributions. However, the strong relaxation filter required to eliminate most of the lipids also reduces the signals for small metabolites. The aim of our study was therefore to investigate different diffusion editing techniques in order to employ diffusion differences for separating lipid and small metabolite contributions in the spectra from different organs for unbiased metabonomic analysis. Thus, 1D and 2D diffusion measurements were performed, and pure lipid spectra that were obtained at strong diffusion weighting (DW) were subtracted from those obtained at low DW, which include both small metabolites and lipids. This subtraction yielded almost lipid free small metabolite spectra from muscle tissue. Further improved separation was obtained by combining a 1D diffusion sequence with a T2-filter, with the subtraction method eliminating residual lipids from the spectra. Similar results obtained for biopsies of different organs suggest that this method is applicable in various tissue types. The elimination of lipids from HR-MAS spectra and the resulting less biased assessment of small metabolites have potential to remove ambiguities in the interpretation of metabonomic results. This is demonstrated in a reproducibility study on biopsies from human muscle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the inter/intraobserver variability of apparent diffusion coefficient (ADC) measurements in treated hepatic lesions and to compare ADC measurements in the whole lesion and in the area with the most restricted diffusion (MRDA). MATERIALS AND METHODS: Twenty-five patients with treated malignant liver lesions were examined on a 3.0T machine. After agreeing on the best ADC image, two readers independently measured the ADC values in the whole lesion and in the MRDA. These measurements were repeated 1 month later. The Bland-Altman method, Spearman correlation coefficients, and the Wilcoxon signed-rank test were used to evaluate the measurements. RESULTS: Interobserver variability for ADC measurements in the whole lesion and in the MRDA was 0.17 x 10(-3) mm(2)/s [-0.17, +0.17] and 0.43 x 10(-3) mm(2)/s [-0.45, +0.41], respectively. Intraobserver limits of agreement could be as low as [-0.10, +0.12] 10(-3) mm(2)/s and [-0.20, +0.33] 10(-3) mm(2)/s for measurements in the whole lesion and in the MRDA, respectively. CONCLUSION: A limited variability in ADC measurements does exist, and it should be considered when interpreting ADC values of hepatic malignancies. This is especially true for the measurements of the minimal ADC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Machine learning and pattern recognition methods have been used to diagnose Alzheimer's disease (AD) and mild cognitive impairment (MCI) from individual MRI scans. Another application of such methods is to predict clinical scores from individual scans. Using relevance vector regression (RVR), we predicted individuals' performances on established tests from their MRI T1 weighted image in two independent data sets. From Mayo Clinic, 73 probable AD patients and 91 cognitively normal (CN) controls completed the Mini-Mental State Examination (MMSE), Dementia Rating Scale (DRS), and Auditory Verbal Learning Test (AVLT) within 3months of their scan. Baseline MRI's from the Alzheimer's disease Neuroimaging Initiative (ADNI) comprised the other data set; 113 AD, 351 MCI, and 122 CN subjects completed the MMSE and Alzheimer's Disease Assessment Scale-Cognitive subtest (ADAS-cog) and 39 AD, 92 MCI, and 32 CN ADNI subjects completed MMSE, ADAS-cog, and AVLT. Predicted and actual clinical scores were highly correlated for the MMSE, DRS, and ADAS-cog tests (P<0.0001). Training with one data set and testing with another demonstrated stability between data sets. DRS, MMSE, and ADAS-Cog correlated better than AVLT with whole brain grey matter changes associated with AD. This result underscores their utility for screening and tracking disease. RVR offers a novel way to measure interactions between structural changes and neuropsychological tests beyond that of univariate methods. In clinical practice, we envision using RVR to aid in diagnosis and predict clinical outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Mountain Research Initiative invited Dr Eva Spehn, Director of the Global Mountain Biodiversity Assessment (GMBA), and Dr Antoine Guisan, head of the Spatial Ecology Group at the University of Lausanne, to introduce the reader to their coordinated efforts to advance understanding and prediction of mountain biodiversity. Antoine Guisan's EUROMONT project is one of the many scientific projects that may potentially provide data for the new GMBA initiative for a GIS mountain biodiversity database.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the short- and mid-term evolutions of the apparent diffusion coefficient of lesions treated with RF, in order to determine if the ADC can be used as a marker of tumour response. Methods and Materials: Twenty patients were treated for a liver malignancy with RF and were examined on a 1.5 T/3.0 T machine with T2, gadolinium-enhanced T1 and diffusion sequences: before treatment (< 1 month), just after treatment (< 1 month) and midterm (3-6 months). The ADC was measured in the whole lesion and in the area with the most restricted diffusion (MRDA). The ROI size was also measured on the diffusion map. The Pearson/ANOVA tests were used. Results: All patients were successfully treated with complete disappearance of CE. The lesional size on T2 showed a negative evolution in time (p < 0.002). The ADC in the whole lesion showed a bell-shaped evolution (increasing just after RF, then decreasing, p = 0.02). The ROI size on the diffusion map followed a similar course (p = 0.01). For the MRDA, such evolutions were also found, but they were not significant. There was a negative correlation between CE and the ADC (p < 0.02) and between the lesional size on T2 and ADC (p = 0.03) in the whole lesion. There were also positive correlations between the ROI size and ADC (p = 0.0008) and between CE and the size on T2 (p = 0.0002). The ADC in MRDA showed some non-significant correlations with other variables. Conclusion: The lesions successfully treated with RF have a clear and predictable evolution in terms of T2 size, CE and ADC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 41-year-old male presented with severe frostbite that was monitored clinically and with a new laser Doppler imaging (LDI) camera that records arbitrary microcirculatory perfusion units (1-256 arbitrary perfusion units (APU's)). LDI monitoring detected perfusion differences in hand and foot not seen visually. On day 4-5 after injury, LDI showed that while fingers did not experience any significant perfusion change (average of 31±25 APUs on day 5), the patient's left big toe did (from 17±29 APUs day 4 to 103±55 APUs day 5). These changes in regional perfusion were not detectable by visual examination. On day 53 postinjury, all fingers with reduced perfusion by LDI were amputated, while the toe could be salvaged. This case clearly demonstrates that insufficient microcirculatory perfusion can be identified using LDI in ways which visual examination alone does not permit, allowing prognosis of clinical outcomes. Such information may also be used to develop improved treatment approaches.