978 resultados para particulate fraction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aerosol particles are strongly related to climate, air quality, visibility and human health issues. They contribute the largest uncertainty in the assessment of the Earth´s radiative budget, directly by scattering or absorbing solar radiation or indirectly by nucleating cloud droplets. The influence of aerosol particles on cloud related climatic effects essentially depends upon their number concentration, size and chemical composition. A major part of submicron aerosol consists of secondary organic aerosol (SOA) that is formed in the atmosphere by the oxidation of volatile organic compounds. SOA can comprise a highly diverse spectrum of compounds that undergo continuous chemical transformations in the atmosphere.rnThe aim of this work was to obtain insights into the complexity of ambient SOA by the application of advanced mass spectrometric techniques. Therefore, an atmospheric pressure chemical ionization ion trap mass spectrometer (APCI-IT-MS) was applied in the field, facilitating the measurement of ions of the intact molecular organic species. Furthermore, the high measurement frequency provided insights into SOA composition and chemical transformation processes on a high temporal resolution. Within different comprehensive field campaigns, online measurements of particular biogenic organic acids were achieved by combining an online aerosol concentrator with the APCI-IT-MS. A holistic picture of the ambient organic aerosol was obtained through the co-located application of other complementary MS techniques, such as aerosol mass spectrometry (AMS) or filter sampling for the analysis by liquid chromatography / ultrahigh resolution mass spectrometry (LC/UHRMS).rnIn particular, during a summertime field study at the pristine boreal forest station in Hyytiälä, Finland, the partitioning of organic acids between gas and particle phase was quantified, based on the online APCI-IT-MS and AMS measurements. It was found that low volatile compounds reside to a large extent in the gas phase. This observation can be interpreted as a consequence of large aerosol equilibration timescales, which build up due to the continuous production of low volatile compounds in the gas phase and/or a semi-solid phase state of the ambient aerosol. Furthermore, in-situ structural informations of particular compounds were achieved by using the MS/MS mode of the ion trap. The comparison to MS/MS spectra from laboratory generated SOA of specific monoterpene precursors indicated that laboratory SOA barely depicts the complexity of ambient SOA. Moreover, it was shown that the mass spectra of the laboratory SOA more closely resemble the ambient gas phase composition, indicating that the oxidation state of the ambient organic compounds in the particle phase is underestimated by the comparison to laboratory ozonolysis. These observations suggest that the micro-scale processes, such as the chemistry of aerosol aging or the gas-to-particle partitioning, need to be better understood in order to predict SOA concentrations more reliably.rnDuring a field study at the Mt. Kleiner Feldberg, Germany, a slightly different aerosol concentrator / APCI-IT-MS setup made the online analysis of new particle formation possible. During a particular nucleation event, the online mass spectra indicated that organic compounds of approximately 300 Da are main constituents of the bulk aerosol during ambient new particle formation. Co-located filter analysis by LC/UHRMS analysis supported these findings and furthermore allowed to determine the molecular formulas of the involved organic compounds. The unambiguous identification of several oxidized C 15 compounds indicated that oxidation products of sesquiterpenes can be important compounds for the initial formation and subsequent growth of atmospheric nanoparticles.rnThe LC/UHRMS analysis furthermore revealed that considerable amounts of organosulfates and nitrooxy organosulfates were detected on the filter samples. Indeed, it was found that several nitrooxy organosulfate related APCI-IT-MS mass traces were simultaneously enhanced. Concurrent particle phase ion chromatography and AMS measurements indicated a strong bias between inorganic sulfate and total sulfate concentrations, supporting the assumption that substantial amounts of sulfate was bonded to organic molecules.rnFinally, the comprehensive chemical analysis of the aerosol composition was compared to the hygroscopicity parameter kappa, which was derived from cloud condensation nuclei (CCN) measurements. Simultaneously, organic aerosol aging was observed by the evolution of a ratio between a second and a first generation biogenic oxidation product. It was found that this aging proxy positively correlates with increasing hygroscopicity. Moreover, it was observed that the bonding of sulfate to organic molecules leads to a significant reduction of kappa, compared to an internal mixture of the same mass fractions of purely inorganic sulfate and organic molecules. Concluding, it has been shown within this thesis that the application of modern mass spectrometric techniques allows for detailed insights into chemical and physico-chemical processes of atmospheric aerosols.rn

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gli ammassi di galassie sono le strutture gravitazionalmente legate con le più profonde buche di potenziale, pertanto è previsto che questi contengano una frazione di barioni non molto diversa da quella cosmologica. Con l’introduzione di modelli sempre più accurati di fisica barionica all’interno di simulazioni idrodinamiche è stato possibile predire la percentuale cosmica di barioni presente negli ammassi di galassie. Unendo questi modelli previsionali con misure della frazione di gas in ammassi e informazioni sulla densità di barioni dell’Universo si può ottenere una stima della densità di materia cosmica Ωm. L'obiettivo di questo lavoro di Tesi è la stima di Ωm a partire dalla frazione di gas osservata in questi sistemi. Questo lavoro era stato già fatto in precedenza, ma tenendo in considerazione solo gli ammassi più massivi e dinamicamente rilassati. Usando parametri che caratterizzano la morfologia della distribuzione di brillanza superficiale nei raggi X, abbiamo classificato i nostri oggetti come rilassati o disturbati, laddove presentassero evidenze di recenti attività di interazione. Abbiamo dunque valutato l’impatto degli oggetti disturbati sulla stima del parametro cosmologico Ωm, computando il Chi2 tra la frazione di massa barionica nell’Universo e quella da noi ricavata. Infine abbiamo investigato una relazione tra il valore della frazione di gas degli ammassi rilassati e quello dei disturbati, in modo da correggere quindi questi ultimi, riportandoli nei dintorni del valore medio per i rilassati e usarli per ampliare il campione e porre un vincolo più stringente su Ωm. Anche con il limitato campione a nostra disposizione, è stato possibile porre un vincolo più stretto su Ωm, utilizzando un maggior numero di oggetti e riducendo così l’errore statistico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Die Gesundheitseffekte von Aerosolpartikeln werden stark von ihren chemischen und physikalischen Eigenschaften und somit den jeweiligen Bildungsprozessen und Quellencharakteristika beeinflusst. Während die Hauptquellen der anthropogenen Partikelemissionen gut untersucht sind, stellen die spezifischen Emissionsmuster zahlreicher kleiner Aerosolquellen, welche lokal und temporär zu einer signifikanten Verschlechterung der Luftqualität beitragen können, ein Forschungsdesiderat dar.rnIn der vorliegenden Arbeit werden in kombinierten Labor- und Feldmessungen durch ein integratives Analysekonzept mittels online (HR-ToF-AMS ) und filterbasierter offline (ATR-FTIR-Spektroskopie ) Messverfahren die weitgehend unbekannten physikalischen und chemischen Eigenschaften der Emissionen besonderer anthropogener Aerosolquellen untersucht. Neben einem Fußballstadion als komplexe Mischung verschiedener Aerosolquellen wie Frittieren und Grillen, Zigarettenrauchen und Pyrotechnik werden die Emissionen durch Feuerwerkskörper, landwirtschaftliche Intensivtierhaltung (Legehennen), Tief- und Straßenbauarbeiten sowie abwasserbürtige Aerosolpartikel in die Studie mit eingebunden. Die primären Partikelemissionen der untersuchten Quellen sind vorrangig durch kleine Partikelgrößen (dp < 1 µm) und somit eine hohe Lungengängigkeit gekennzeichnet. Dagegen zeigen die Aerosolpartikel im Stall der landwirtschaftlichen Intensivtierhaltung sowie die Emissionen durch die Tiefbauarbeiten einen hohen Masseanteil von Partikeln dp > 1 µm. Der Fokus der Untersuchung liegt auf der chemischen Charakterisierung der organischen Partikelbestandteile, welche für viele Quellen die NR-PM1-Emissionen dominieren. Dabei zeigen sich wichtige quellenspezifische Unterschiede in der Zusammensetzung der organischen Aerosolfraktion. Die beim Abbrand von pyrotechnischen Gegenständen freigesetzten sowie die abwasserbürtigen Aerosolpartikel enthalten dagegen hohe relative Gehalte anorganischer Substanzen. Auch können in einigen spezifischen Emissionen Metallverbindungen in den AMS-Massenspektren nachgewiesen werden. Über die Charakterisierung der Emissionsmuster und -dynamiken hinaus werden für einige verschiedenfarbige Rauchpatronen sowie die Emissionen im Stall der Intensivtierhaltung Emissionsfaktoren bestimmt, die zur quantitativen Bilanzierung herangezogen werden können. In einem weiteren Schritt werden anhand der empirischen Daten die analytischen Limitierungen der Aerosolmassenspektrometrie wie die Interferenz organischer Fragmentionen durch (Hydrogen-)Carbonate und mögliche Auswertestrategien zur Überwindung dieser Grenzen vorgestellt und diskutiert.rnEine umfangreiche Methodenentwicklung zur Verbesserung der analytischen Aussagekraft von organischen AMS-Massenspektren zeigt, dass für bestimmte Partikeltypen einzelne Fragmentionen in den AMS-Massenspektren signifikant mit ausgewählten funktionellen Molekülgruppen der FTIR-Absorptionsspektren korrelieren. Bedingt durch ihre fehlende Spezifität ist eine allgemeingültige Interpretation von AMS-Fragmentionen als Marker für verschiedene funktionelle Gruppen nicht zulässig und häufig nur durch die Ergebnisse der komplementären FTIR-Spektroskopie möglich. Des Weiteren wurde die Verdampfung und Ionisation ausgewählter Metallverbindungen im AMS analysiert. Die Arbeit verdeutlicht, dass eine qualitative und quantitative Auswertung dieser Substanzen nicht ohne Weiteres möglich ist. Die Gründe hierfür liegen in einer fehlenden Reproduzierbarkeit des Verdampfungs- und Ionisationsprozesses aufgrund von Matrixeffekten sowie der in Abhängigkeit vorangegangener Analysen (Verdampferhistorie) in der Ionisationskammer und auf dem Verdampfer statt-findenden chemischen Reaktionen.rnDie Erkenntnisse der Arbeit erlauben eine Priorisierung der untersuchten anthropogenen Quellen nach bestimmten Messparametern und stellen für deren Partikelemissionen den Ausgangpunkt einer Risikobewertung von atmosphärischen Folgeprozessen sowie potentiell negativen Auswirkungen auf die menschliche Gesundheit dar. rn

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gli aerosol, sospensione colloidale in aria di particelle solide o liquide, sono parte integrante dell’atmosfera. Essi interagiscono con la radiazione solare influenzando il clima (effetto primario e secondario) e la visibilità atmosferica. Gli aerosol hanno effetti sulla salute umana con patologie degli apparati cardiovascolare e circolatorio. La presente tesi affronta alcuni aspetti critici dei contatori ottici di particelle (OPC), utilizzati per caratterizzare l’aerosol ambientale. Gli OPC si basano sullo scattering luminoso per fornire la concentrazione in numero e la distribuzione dimensionale degli aerosol in tempo reale. Gli obiettivi di questa tesi sono: 1)caratterizzare e migliorare le prestazioni di un OPC di nuova concezione (CompactOPC N1, Alphasense; in seguito COPC) rispetto a un OPC standard commerciale (Grimm 1.108; in seguito GRM); 2)realizzare un banco di prova per la calibrazione di un OPC utilizzato in camere bianche e ambienti sanitari (Laser Particle Sensor 3715-00, Kanomax; in seguito LPS). Per questa attività ha mostrato interesse un’azienda locale (Pollution Clean Air Systems S.p.A.; Budrio, BO). Le prove sperimentali sono state effettuate con aerosol indoor e con particelle monodisperse di latex polistirene (PSL) di dimensioni differenti campionando in parallelo con i diversi OPC e su filtro per osservazioni al microscopio elettronico a scansione (SEM). In questo modo si è ottenuto un valore assoluto di riferimento per la concentrazione di aerosol. I risultati ottenuti indicano un buon accordo tra le concentrazioni di particelle fornite dal GRM e quelle ottenute al SEM. Il lavoro ha inoltre permesso di migliorare le prestazioni del COPC modificando la versione di base. Inoltre, è stata effettuata la calibrazione del LPS tramite il banco di prova realizzato nella tesi. Il lavoro sperimentale è stato svolto presso il Laboratorio di Aerosol e Fisica delle Nubi dell’Istituto di Scienze dell’Atmosfera e del Clima (ISAC) del Consiglio Nazionale delle Ricerche (CNR) a Bologna.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We performed 124 measurements of particulate matter (PM(2.5)) in 95 hospitality venues such as restaurants, bars, cafés, and a disco, which had differing smoking regulations. We evaluated the impact of spatial separation between smoking and non-smoking areas on mean PM(2.5) concentration, taking relevant characteristics of the venue, such as the type of ventilation or the presence of additional PM(2.5) sources, into account. We differentiated five smoking environments: (i) completely smoke-free location, (ii) non-smoking room spatially separated from a smoking room, (iii) non-smoking area with a smoking area located in the same room, (iv) smoking area with a non-smoking area located in the same room, and (v) smoking location which could be either a room where smoking was allowed that was spatially separated from non-smoking room or a hospitality venue without smoking restriction. In these five groups, the geometric mean PM(2.5) levels were (i) 20.4, (ii) 43.9, (iii) 71.9, (iv) 110.4, and (v) 110.3 microg/m(3), respectively. This study showed that even if non-smoking and smoking areas were spatially separated into two rooms, geometric mean PM(2.5) levels in non-smoking rooms were considerably higher than in completely smoke-free hospitality venues. PRACTICAL IMPLICATIONS: PM(2.5) levels are considerably increased in the non-smoking area if smoking is allowed anywhere in the same location. Even locating the smoking area in another room resulted in a more than doubling of the PM(2.5) levels in the non-smoking room compared with venues where smoking was not allowed at all. In practice, spatial separation of rooms where smoking is allowed does not prevent exposure to environmental tobacco smoke in nearby non-smoking areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The past decade has seen significant increases in combustion-generated ambient particles, which contain a nanosized fraction (less than 100 nm), and even greater increases have occurred in engineered nanoparticles (NPs) propelled by the booming nanotechnology industry. Although inhalation of these particulates has become a public health concern, human health effects and mechanisms of action for NPs are not well understood. Focusing on the human airway smooth muscle cell, here we show that the cellular mechanical function is altered by particulate exposure in a manner that is dependent upon particle material, size and dose. We used Alamar Blue assay to measure cell viability and optical magnetic twisting cytometry to measure cell stiffness and agonist-induced contractility. The eight particle species fell into four categories, based on their respective effect on cell viability and on mechanical function. Cell viability was impaired and cell contractility was decreased by (i) zinc oxide (40-100 nm and less than 44 microm) and copper(II) oxide (less than 50 nm); cell contractility was decreased by (ii) fluorescent polystyrene spheres (40 nm), increased by (iii) welding fumes and unchanged by (iv) diesel exhaust particles, titanium dioxide (25 nm) and copper(II) oxide (less than 5 microm), although in none of these cases was cell viability impaired. Treatment with hydrogen peroxide up to 500 microM did not alter viability or cell mechanics, suggesting that the particle effects are unlikely to be mediated by particle-generated reactive oxygen species. Our results highlight the susceptibility of cellular mechanical function to particulate exposures and suggest that direct exposure of the airway smooth muscle cells to particulates may initiate or aggravate respiratory diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Systolic right ventricular (RV) function is an important predictor in the course of various congenital and acquired heart diseases. Its practical determination by echocardiography remains challenging. We compared routine assessment of lateral tricuspid annular systolic motion velocity (TV(lat), cm/s) using pulsed-wave tissue Doppler imaging from the apical 4-chamber view with cardiac magnetic resonance (CMR) as reference method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Reduced left ventricular function in patients with severe symptomatic valvular aortic stenosis is associated with impaired clinical outcome in patients undergoing surgical aortic valve replacement (SAVR). Transcatheter Aortic Valve Implantation (TAVI) has been shown non-inferior to SAVR in high-risk patients with respect to mortality and may result in faster left ventricular recovery. Methods We investigated clinical outcomes of high-risk patients with severe aortic stenosis undergoing medical treatment (n = 71) or TAVI (n = 256) stratified by left ventricular ejection fraction (LVEF) in a prospective single center registry. Results Twenty-five patients (35%) among the medical cohort were found to have an LVEF≤30% (mean 26.7±4.1%) and 37 patients (14%) among the TAVI patients (mean 25.2±4.4%). Estimated peri-interventional risk as assessed by logistic EuroSCORE was significantly higher in patients with severely impaired LVEF as compared to patients with LVEF>30% (medical/TAVI 38.5±13.8%/40.6±16.4% versus medical/TAVI 22.5±10.8%/22.1±12.8%, p <0.001). In patients undergoing TAVI, there was no significant difference in the combined endpoint of death, myocardial infarction, major stroke, life-threatening bleeding, major access-site complications, valvular re-intervention, or renal failure at 30 days between the two groups (21.0% versus 27.0%, p = 0.40). After TAVI, patients with LVEF≤30% experienced a rapid improvement in LVEF (from 25±4% to 34±10% at discharge, p = 0.002) associated with improved NYHA functional class at 30 days (decrease ≥1 NYHA class in 95%). During long-term follow-up no difference in survival was observed in patients undergoing TAVI irrespective of baseline LVEF (p = 0.29), whereas there was a significantly higher mortality in medically treated patients with severely reduced LVEF (log rank p = 0.001). Conclusion TAVI in patients with severely reduced left ventricular function may be performed safely and is associated with rapid recovery of systolic left ventricular function and heart failure symptoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Decision trees have been proposed as a basis for modifying table based injection to reduce transient particulate spikes during the turbocharger lag period. It has been shown that decision trees can detect particulate spikes in real time. In well calibrated electronically controlled diesel engines these spikes are narrow and are encompassed by a wider NOx spike. Decision trees have been shown to pinpoint the exact location of measured opacity spikes in real time thus enabling targeted PM reduction with near zero NOx penalty. A calibrated dimensional model has been used to demonstrate the possible reduction of particulate matter with targeted injection pressure pulses. Post injection strategy optimized for near stoichiometric combustion has been shown to provide additional benefits. Empirical models have been used to calculate emission tradeoffs over the entire FTP cycle. An empirical model based transient calibration has been used to demonstrate that such targeted transient modifiers are more beneficial at lower engine-out NOx levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Smoke spikes occurring during transient engine operation have detrimental health effects and increase fuel consumption by requiring more frequent regeneration of the diesel particulate filter. This paper proposes a decision tree approach to real-time detection of smoke spikes for control and on-board diagnostics purposes. A contemporary, electronically controlled heavy-duty diesel engine was used to investigate the deficiencies of smoke control based on the fuel-to-oxygen-ratio limit. With the aid of transient and steady state data analysis and empirical as well as dimensional modeling, it was shown that the fuel-to-oxygen ratio was not estimated correctly during the turbocharger lag period. This inaccuracy was attributed to the large manifold pressure ratios and low exhaust gas recirculation flows recorded during the turbocharger lag period, which meant that engine control module correlations for the exhaust gas recirculation flow and the volumetric efficiency had to be extrapolated. The engine control module correlations were based on steady state data and it was shown that, unless the turbocharger efficiency is artificially reduced, the large manifold pressure ratios observed during the turbocharger lag period cannot be achieved at steady state. Additionally, the cylinder-to-cylinder variation during this period were shown to be sufficiently significant to make the average fuel-to-oxygen ratio a poor predictor of the transient smoke emissions. The steady state data also showed higher smoke emissions with higher exhaust gas recirculation fractions at constant fuel-to-oxygen-ratio levels. This suggests that, even if the fuel-to-oxygen ratios were to be estimated accurately for each cylinder, they would still be ineffective as smoke limiters. A decision tree trained on snap throttle data and pruned with engineering knowledge was able to use the inaccurate engine control module estimates of the fuel-to-oxygen ratio together with information on the engine control module estimate of the exhaust gas recirculation fraction, the engine speed, and the manifold pressure ratio to predict 94% of all spikes occurring over the Federal Test Procedure cycle. The advantages of this non-parametric approach over other commonly used parametric empirical methods such as regression were described. An application of accurate smoke spike detection in which the injection pressure is increased at points with a high opacity to reduce the cumulative particulate matter emissions substantially with a minimum increase in the cumulative nitrogrn oxide emissions was illustrated with dimensional and empirical modeling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background— The age, creatinine, and ejection fraction (ACEF) score (age/left ventricular ejection fraction+1 if creatinine >2.0 mg/dL) has been established as an effective predictor of clinical outcomes in patients undergoing elective coronary artery bypass surgery; however, its utility in “all-comer” patients undergoing percutaneous coronary intervention is yet unexplored. Methods and Results— The ACEF score was calculated for 1208 of the 1707 patients enrolled in the LEADERS trial. Post hoc analysis was performed by stratifying clinical outcomes at the 1-year follow-up according to ACEF score tertiles: ACEFlow ≤1.0225, 1.0225< ACEFmid ≤1.277, and ACEFhigh >1.277. At 1-year follow-up, there was a significantly lower number of patients with major adverse cardiac event–free survival in the highest tertile of the ACEF score (ACEFlow=92.1%, ACEFmid=89.5%, and ACEFhigh=86.1%; P=0.0218). Cardiac death was less frequent in ACEFlow than in ACEFmid and ACEFhigh (0.7% vs 2.2% vs 4.5%; hazard ratio=2.22, P=0.002) patients. Rates of myocardial infarction were significantly higher in patients with a high ACEF score (6.7% for ACEFhigh vs 5.2% for ACEFmid and 2.5% for ACEFlow; hazard ratio=1.6, P=0.006). Clinically driven target-vessel revascularization also tended to be higher in the ACEFhigh group, but the difference among the 3 groups did not reach statistical significance. The rate of composite definite, possible, and probable stent thrombosis was also higher in the ACEFhigh group (ACEFlow=1.2%, ACEFmid=3.5%, and ACEFhigh=6.2%; hazard ratio=2.04, P<0.001). Conclusions— ACEF score may be a simple way to stratify risk of events in patients treated with percutaneous coronary intervention with respect to mortality and risk of myocardial infarction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fraction of exhaled nitric oxide (Feno), a marker of airway inflammation, has been proposed to be useful for asthma management, but conclusions are inconsistent. This might be due to the failure of mean statistics to characterize individual variability in Feno values, which is possibly a better indicator of asthma control than single measurements.