887 resultados para full-scale testing


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The anaerobic treatment of sewage is widely employed in Brazil and it is an appreciated way for the treatment of effluents, helping to reduce the environmental impact in rivers. The methane gas obtained from the process can be applied to improve the energetic efficiency of the system, reducing the amount of waste and the cost of the treatment process. This work presents the net energy balance of anaerobic reactors applied to the treatment of sewage. The analysis was performed considering full-scale and laboratory-scale treatment systems. In laboratory scale, the results from three kinds of systems were compared regarding the biological treatment of greywater. Two of them (UASB7 and UASB12) were anaerobic and the other one was a combined anaerobic-aerobic system (UASB7/SBR6). Greywater methanization (compared to theoretical maximum) was calculated considering 100% removal (g BOD/day), the literature percentage removal and the anionic surfactant presence in the effluentt. For each of these three cases, the efficiencies were, respectively, 16.9%, 43.6% and 51.3% in UASB7 reactor, 25.6%, 50.3% and 59.2% in UASB12 reactor and 30.6%, 61.2% and 71.9% in UASB7/SBR6 reactor. The energetic potential was found to be 4.66x10-4, 7.77x10-4 and 5.12x10-4 kWh/L for the UASB7, UASB12 and UASB7/SBR6 reactors, respectively. The pumping system, the aeration (in the anaerobic-aerobic system) and the temperature controlled heating system were considered to calculate the energetic consumption. However, the third one was not employed since tropical regions like Brazil do not need heating systems and also because of its high energetic consumption. The calculated net energy balance in the reactors was negative in the case of greywater, respectively -0.16, -0.28 and -0.18 kWh/L for the reactors UASB7, UASB12 and UASB7/SRB6. In full scale (ETE Jardim das Flores - Rio Claro, SP), the average energy... (Complete abstract click electronic access below)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study aimed to produce beer, using different botanical origins of honeys (orange, eucalyptus and wild), as malt adjuncts, and their Physical-chemical and sensorial characterizations. The production was made with malt, water, hops and honey. All musts were adjusted to 12 Brix, and the concentration of honey in the formulation was 45% (based on the extract), except for the control (0%). The physical and chemical analysis were performed on malt (extract content), honey (pH, free acidity, lactonic acidity, total acidity, color, turbidity, extract content, moisture content, reducing sugar, total reducing sugar and sucrose) in wort (content extract, pH, color, turbidity, fermentability ,bitterness and total acidity) and beer apparent extract, apparent fermentability, real extract, real fermentability, alcohol content, pH, total acidity, total foam, foam density , bitterness, carbon dioxide, color and turbidity). Sensory analysis was performed by nine-points hedonic scale testing. The attributes evaluated were appearance, aroma, flavor and overall. The results were submitted to ANOVA and means compared by Tukey testing at a 5% of probability. Beer with honey as adjuncts’ had high fermentability and low content of fat, compared to the pure malt beer. The addition of honey as an adjunct did not affect the majority of the physical-chemical parameters, except for turbidity, whereas beer with honey showed the highest value for this feature, in addition, it has also presented their biterness differences the values for beer with honey were lower. The different types of honeys did not affect the acceptability of beer, however, the beer with honey showed greater acceptance between beer with malt and honey

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this project is to verify whether anaerobic reactors applied to sewage treatment are energetically self-sufficient. This evaluation can be made by balancing the methane produced through the anaerobic transformation stages (hydrolysis, acidogenesis, acetogenesis and methanogenesis) and the reactor energy consumption requirements. The original project included methanogenic activity tests, which could not be performed due to setbacks in the installation of an analytical instrument. Scientific articles about bench- and full-scale anaerobic reactors were investigated instead. An average substrate-to-methane conversion efficiency of 58,2±18,6% was found for the bench-scale reactors and higher efficiencies (89,2%) were found for the cases which had higher Organic Loading Rates (OLRs) values. The average energy output was 0,013 kWh/Lsewage, value unable to meet the energy needs for the reactor operation, considering equipments normally used such as temperature controller. This balance can become positive if few hypotheses are made, for example (i) to eliminate the use of temperature controller (ii) to alter the operation pattern from continuous to intermittent. Based on energy balance assessment of eight bench-scale reactors, it was observed that the implementation of a system for biogas utilization is not energetically feasible. However, interesting results were found for a full-scale sewage treatment plant, ETE Ouro Verde – Foz do Iguaçu, PR, Brazil. Even though its substrate-tomethane conversion efficiency was about 10% only, the energy balance was quite positive, with energy consumption of 68 kWh/month and energy production of 660 kWh/month. This analysis leads us to conclude that energy recovery from full-scale sewage treatment plants should be practiced by other plants

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The degradation of polychlorinated biphenyls (PCBs) was investigated under fermentativemethanogenic conditions for up to 60 days in the presence of anaerobic biomass from a full-scale UASB reactor. The low methane yields in the PCBs-spiked batch reactors suggested that the biomass had an inhibitory effect on the methanogenic community. Reactors containing PCBs and co-substrates (ethanol/ sodium formate) exhibited substantial PCB reductions from 0.7 to 0.2 mg mL-1 . For the Bacteria domain, the PCBs-spiked reactors were grouped with the PCB-free reactors with a similarity of 55 %, which suggested the selection of a specific population in the presence of PCBs. Three genera of bacteria were found exclusively in the PCB-spiked reactors and were identified using pyrosequencing analysis, Sedimentibacter, Tissierela and Fusibacter. Interestingly, the Sedimentibacter, which was previously correlated with the reductive dechlorination of PCBs, had the highest relative abundance in the RCS-PCB (7.4 %) and RCS-PCB-PF (12.4 %) reactors. Thus, the anaerobic sludge from the UASB reactor contains bacteria from the Firmicutes phylum that are capable of degrading PCBs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work aimed to evaluate some aspects of construction and operation of full-scale best management practices and their effects on infiltration loading rate. Two systems were studied: i) filter-swale-trench (FST) and ii) infiltration well (IW). In these units, field essays and full-scale measurements were made in order to assess the soil permeability. Further, the fine particles transportation and the geotextile blanket permeability were determined before and after operation. The results pointed out that there were soil transportation to inside the FST and IW systems, despite of the installed protections, and that these material were responsible for diminishing the geotextile (reduction from 30 to 90% for FST and 40 to 70% for IW) and the full-scale infiltration loading rates (varying from 4,7 x 10-6 to 10-5 m.s-1).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to investigate the performance of an experimental rainwater treatment system for non-potable uses. Without the first-flush discharge it was expected to control the quality of captured rainwater and to minimize the rainwater by-pass caused by the first-flush strategy. A full-scale direct filtration unit was operated and a solution of natural corn starch was used as the primary coagulant. The color, turbidity e coliform efficiencies of the unit was analyzed based on filtration loads and the net water production was estimated. The results pointed out turbidity removal up to 70.8% and color removal up to 61.0%. The backwash of the filtering system was completed in 3 minutes at the rate of 1,440 m3/m2day with consumption of treated water from 0.5% to 2.2%, based on the potentially harvesting.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article presents the results of research conducted on full-scale models, studying the behavior of steel sleepers under the action of static loads, in vertical, longitudinal and transverse directions. For the research models were run with rails TR-68, fixed with elastic system on seven sleepers each type, separately, embedded in standard ballast with 35 cm height and on the basis of compacted soil with 30 cm thick. For the load tests were constructed using reaction systems of vertical and horizontal forces with the objective of applying the requests. The system of readings and data acquisition was fully computerized, obtaining in real time the values of forces and displacements. The results were compared with those installed in the same way with sleepers of wood, mono-block and bi-block prestressed concrete. The analyzed results provided unprecedented parameters in Brazil and of great importance for the design of modern railway permanent way, using steel sleepers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction. Epilepsy surgery may be a promising alternative therapy for seizure control in patients with refractory seizures, resistant to medication. Cognitive outcome is another important factor in favor of the surgical decision. Aim. To investigate the correlation between seizure outcome and cognitive outcome after epilepsy surgery in a pediatric population. Patients and methods. A total of 59 pediatric patients were retrospectively assessed with the WISC-III (Full Scale, Verbal Scale and Performance Scale) before and, at least, 6 months after surgery. Patients were divided into two groups according whether or not improvement of seizure control after surgery. Data collected for each child included: epileptic syndrome, etiology, age at epilepsy onset, duration of epilepsy and seizure frequency. Results. Comparison using a MANOVA test revealed significant differences across pre-operative Full Scale, Verbal Scale and Performance Scale (p = 0.01) with seizure reduction group performing better than no seizure reduction group. Seizure improvement group achieved significant Performance Scale improvement (p = 0.01) and no seizure improvement group showed significant Verbal Scale worsened after surgery (p = 0.01). Conclusions. Our results suggest that the success of the epilepsy surgery in childhood when the seizure control is achieved may also provide an improvement in the Performance Scale whereas the seizure maintenance may worsen the Verbal Scale.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Field experiments have demonstrated that piles driven into sand can respond to axial cyclic loading in Stable, Unstable or Meta-Stable ways, depending on the combinations of mean and cyclic loads and the number of cycles. An understanding of the three styles of responses is provided by experiments involving a highly instrumented model displacement pile and an array of soil stress sensors installed in fine sand in a pressurised calibration chamber. The different patterns of effective stress developing on and around the shaft are reported, along with the results of static load tests that track the effects on shaft capacity. The interpretation links these observations to the sand's stress strain behaviour. The interface-shear characteristics, the kinematic yielding, the local densification, the growth of a fractured interface-shear zone and the restrained dilatancy at the pile soil interface are all found to be important. The model tests are shown to be compatible with the full-scale behaviour and to provide key information for improving the modelling and the design rules. (C) 2012 The Japanese Geotechnical Society. Production and hosting by Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper reports the results of full-scale tests in beam-to-column connections for composite slim floor systems, including tests on Bare Steel connection and composite connection. The tested system consists of a concrete-filled composite column and a composite floor where an asymmetric steel beam is connected to a composite column by shear steel plates. Tests results previously obtained on partially encased composite beams were used to define the position of the headed studs in the slim floor system. Based on the obtained results of connections, the composite and Bare Steel connection behaved as semi-rigid and nominally pinned respectively. The tests results also indicated a significant contribution of the slim floor to the moment capacity of the connection. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A two-stage bioreactor was operated for a period of 140 days in order to develop a post-treatment process based on anaerobic bioxidation of sulfite. This process was designed for simultaneously treating the effluent and biogas of a full-scale UASB reactor, containing significant concentrations of NH4 and H2S, respectively. The system comprised of two horizontal-flow bed-packed reactors operated with different oxygen concentrations. Ammonium present in the effluent was transformed into nitrates in the first aerobic stage. The second anaerobic stage combined the treatment of nitrates in the liquor with the hydrogen sulfide present in the UASB-reactor biogas. Nitrates were consumed with a significant production of sulfate, resulting in a nitrate removal rate of 0.43 kg N m(3) day(-1) and a parts per thousand yen92 % efficiency. Such a removal rate is comparable to those achieved by heterotrophic denitrifying systems. Polymeric forms of sulfur were not detected (elementary sulfur); sulfate was the main product of the sulfide-based denitrifying process. S-sulfate was produced at a rate of about 0.35 kg m(3) day(-1). Sulfur inputs as S-H2S were estimated at about 0.75 kg m(3) day(-1) and Chemical Oxygen Demand (COD) removal rates did not vary significantly during the process. DGGE profiling and 16S rRNA identified Halothiobacillus-like species as the key microorganism supporting this process; such a strain has not yet been previously associated with such bioengineered systems.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper is the first part of an extensive work focusing the technological development of steel fiber reinforced concrete pipes (FRCP). Here is presented and discussed the experimental campaign focusing the test procedure and the mechanical behavior obtained for each of the dosages of fiber used. In the second part ("Steel fiber reinforced concrete pipes. Part 2: Numerical model to simulate the crushing test"), the aspects of FRCP numerical modeling are presented and analyzed using the same experimental results in order to be validated. This study was carried out trying to reduce some uncertainties related to FRCP performance and provide a better condition to the use of these components. In this respect, an experimental study was carried out using sewage concrete pipes in full scale as specimens. The diameter of the specimens was 600 mm, and they had a length of 2500 mm. The pipes were reinforced with traditional bars and different contents of steel fibers in order to compare their performance through the crushing test. Two test procedures were used in that sense. In the 1st Series, the diameter displacement was monitored by the use of two LVDTs positioned at both extremities of the pipes. In the 2nd Series, just one LVDT is positioned at the spigot. The results shown a more rigidity response of the pipe during tests when the displacements were measured at the enlarged section of the socket. The fiber reinforcement was very effective, especially when low level of displacement was imposed to the FRCP. At this condition, the steel fibers showed an equivalent performance to superior class pipes made with traditional reinforced. The fiber content of 40 kg/m3 provided a hardening behavior for the FRCP, and could be considered as equivalent to the critical volume in this condition.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Il presente elaborato è stato finalizzato allo sviluppo di un processo di digestione anaerobica della frazione organica dei rifiuti solidi urbani (FORSU oppure, in lingua inglese OFMSW, Organic Fraction of Municipal Solid Waste) provenienti da raccolta indifferenziata e conseguente produzione di biogas da impiegarsi per il recupero energetico. Questo lavoro rientra nell’ambito di un progetto, cofinanziato dalla Regione Emilia Romagna attraverso il Programma Regionale per la Ricerca Industriale, l’Innovazione e il Trasferimento Tecnologico (PRRIITT), sviluppato dal Dipartimento di Chimica Applicata e Scienza dei Materiali (DICASM) dell’Università di Bologna in collaborazione con la Facoltà di Ingegneria dell’Università di Ferrara e con la società Recupera s.r.l. che applicherà il processo nell’impianto pilota realizzato presso il proprio sito di biostabilizzazione e compostaggio ad Ostellato (FE). L’obiettivo è stato la verifica della possibilità di impiegare la frazione organica dei rifiuti indifferenziati per la produzione di biogas, e in particolare di metano, attraverso un processo di digestione anaerobica previo trattamento chimico oppure in codigestione con altri substrati organici facilmente fermentabili. E’ stata inoltre studiata la possibilità di impiego di reattori con biomassa adesa per migliorare la produzione specifica di metano e diminuire la lag phase. Dalla sperimentazione si può concludere che è possibile giungere allo sviluppo di metano dalla purea codigerendola assieme a refluo zootecnico. Per ottenere però produzioni significative la quantità di solidi volatili apportati dal rifiuto non deve superare il 50% dei solidi volatili complessivi. Viceversa, l’addizione di solfuri alla sola purea si è dimostrata ininfluente nel tentativo di sottrarre gli agenti inibitori della metanogenesi. Inoltre, l’impiego di supporti di riempimento lavorando attraverso processi batch sequenziali permette di eliminare, nei cicli successivi al primo, la lag phase dei batteri metanogeni ed incrementare la produzione specifica di metano.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nella tesi si analizzano le principali fonti del rumore aeronautico, lo stato dell'arte dal punto di vista normativo, tecnologico e procedurale. Si analizza lo stato dell'arte anche riguardo alla classificazione degli aeromobili, proponendo un nuovo indice prestazionale in alternativa a quello indicato dalla metodologia di certificazione (AC36-ICAO) Allo scopo di diminuire l'impatto acustico degli aeromobili in fase di atterraggio, si analizzano col programma INM i benefici di procedure CDA a 3° rispetto alle procedure tradizionali e, di seguito di procedure CDA ad angoli maggiori in termini di riduzione di lunghezza e di area delle isofoniche SEL85, SEL80 e SEL75.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Programa de doctorado en Oceanografía. La fecha de publicación es la fecha de lectura