863 resultados para Tendon Vibration
Resumo:
Bees generate thoracic vibrations with their indirect flight muscles in various behavioural contexts. The main frequency component of non-flight vibrations, during which the wings are usually folded over the abdomen, is higher than that of thoracic vibrations that drive the wing movements for flight. So far, this has been concluded from an increase in natural frequency of the oscillating system in association with the wing adduction. In the present study, we measured the thoracic oscillations in stingless bees during stationary flight and during two types of non-flight behaviour, annoyance buzzing and forager communication, using laser vibrometry. As expected, the flight vibrations met all tested assumptions for resonant oscillations: slow build-up and decay of amplitude; increased frequency following reduction of the inertial load; and decreased frequency following an increase of the mass of the oscillating system. Resonances, however, do not play a significant role in the generation of non-flight vibrations. The strong decrease in main frequency at the end of the pulses indicates that these were driven at a frequency higher than the natural frequency of the system. Despite significant differences regarding the main frequency components and their oscillation amplitudes, the mechanism of generation is apparently similar in annoyance buzzing and forager vibrations. Both types of non-flight vibration induced oscillations of the wings and the legs in a similar way. Since these body parts transform thoracic oscillations into airborne sounds and substrate vibrations, annoyance buzzing can also be used to study mechanisms of signal generation and transmission potentially relevant in forager communication under controlled conditions.
Resumo:
In stingless bees, recruitment of hive bees to food sources involves thoracic vibrations by foragers during trophallaxis. The temporal pattern of these vibrations correlates with the sugar concentration of the collected food. One possible pathway for transfering such information to nestmates is through airborne sound. In the present study, we investigated the transformation of thoracic vibrations into air particle velocity, sound pressure, and jet airflows in the stingless bee Melipona scutellaris. Whereas particle velocity and sound pressure were found all around and above vibrating individuals, there was no evidence for a jet airflow as with honey bees. The largest particle velocities were measured 5 mm above the wings (16.0 +/- 4.8 mm s(-1)). Around a vibrating individual, we found maximum particle velocities of 8.6 +/- 3.0 mm s(-1) (horizontal particle velocity) in front of the bee`s head and of 6.0 +/- 2.1 mm s(-1) (vertical particle velocity) behind its wings. Wing oscillations, which are mainly responsible for air particle movements in honey bees, significantly contributed to vertically oriented particle oscillations only close to the abdomen in M. scutellaris(distances <= 5 mm). Almost 80% of the hive bees attending trophallactic food transfers stayed within a range of 5 mm from the vibrating foragers. It remains to be shown, however, whether air particle velocity alone is strong enough to be detected by Johnston`s organ of the bee antenna. Taking the physiological properties of the honey bee`s Johnston`s organ as the reference, M. scutellaris hive bees are able to detect the forager vibrations through particle movements at distances of up to 2 cm.
Resumo:
New differential linear coherent scattering coefficient, mu(CS), data for four biological tissue types (fat pork, tendon chicken, adipose and fibroglandular human breast tissues) covering a large momentum transfer interval (0.07 <= q <= 70.5 nm(-1)), resulted from combining WAXS and SAXS data, are presented in order to emphasize the need to update the default data-base by including the molecular interference and the large-scale arrangements effect. The results showed that the differential linear coherent scattering coefficient demonstrates influence of the large-scale arrangement, mainly due to collagen fibrils for tendon chicken and fibroglandular breast samples, and triacylglycerides for fat pork and adipose breast samples at low momentum transfer region. While, at high momentum transfer, the mu(CS) reflects effects of molecular interference related to water for tendon chicken and fibroglandular samples and, fatty acids for fat pork and adipose samples. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
BACKGROUND: Retention of airway secretions is a common and serious problem in ventilated patients. Treating or avoiding secretion retention with mucus thinning, patient-positioning, airway suctioning, or chest or airway vibration or percussion may provide short-term benefit. METHODS: In a series of laboratory experiments with a test-lung system we examined the role of ventilator settings and lung-impedance on secretion retention and expulsion. Known quantities of a synthetic dye-stained mucus simulant with clinically relevant properties were injected into a transparent tube the diameter of an adult trachea and exposed to various mechanical-ventilation conditions. Mucus-simulant movement was measured with a photodensitometric technique and examined with image-analysis software. We tested 2 mucus-simulant viscosities and various peak flows, inspiratory/ expiratory flow ratios, intrinsic positive end-expiratory pressures, ventilation waveforms, and impedance values. RESULTS: Ventilator settings that produced flow bias had a major effect on mucus movement. Expiratory How bias associated with intrinsic positive end-expiratory pressure generated by elevated minute ventilation moved mucus toward the airway opening, whereas intrinsic positive end-expiratory pressure generated by increased airway resistance moved the mucus toward the lungs. Inter-lung transfer of mucus simulant occurred rapidly across the ""carinal divider"" between interconnected test lungs set to radically different compliances; the mucus moved out of the low-compliance lung and into the high-compliance lung. CONCLUSIONS: The movement of mucus simulant was influenced by the ventilation pattern and lung impedance. Flow bias obtained with ventilator settings may clear or embed mucus during mechanical ventilation.
Resumo:
Telecanthus, the lateral displacement of the medial canthus, can be a congenital deformity or can occur after facial trauma or tumor resection. Treatment of telecanthus remains a challenge for plastic surgeons. For proper correction, it is necessary to shift the medial canthus medially, fixing its tendon to the bone. The ideal technique would allow easy, safe, and stable fixation of the tendon, permit a unilateral approach with minimal incisions, and be cost-effective. The purpose of this study was to evaluate the feasibility and results (immediate and long-term) of medial telecanthus repair using ipsilateral titanium microanchor fixation. Nine patients, 7 with unilateral telecanthus and 2 with bilateral telecanthus, underwent ipsilateral canthopexy involving a microanchor device. Anthropometric measurements of the orbital regions were taken before, immediately after, and at 1 year after surgery. Data for the affected sides were compared with those for the unaffected sides, and the evolution of those values was assessed throughout the 1-year follow-up period. For all patients, the final values were lower than those initially obtained. At 1 year after surgery, the intercanthal distance was reduced to age-adjusted normal values in all cases. On the operated side, stable improvement was observed in terms of the distance from the medial canthus to the midline, although some degree of recurrence was noted in most of the patients. The use of a microanchor system for medial canthopexy can be considered an easily performed and effective option for treating canthal dystopia, especially when an ipsilateral approach is preferred.
Resumo:
To understand the dynamic mechanisms of the mechanical milling process in a vibratory mill, it is necessary to determine the characteristics of the impact forces associated with the collision events. However, it is difficult to directly measure the impact force in an operating mill. This paper describes an inverse technique for the prediction of impact forces from acceleration measurements on a vibratory ball mill. The characteristics of the vibratory mill have been investigated by the modal testing technique, and its system modes have been identified. In the modelling of the system vibration response to the impact forces, two modal equations have been used to describe the modal responses. The superposition of the modal responses gives rise to the total response of the system. A method based on an optimisation approach has been developed to predict the impact forces by minimising the difference between the measured acceleration of the vibratory ball mill and the predicted acceleration from the solution of the modal equations. The predicted and measured impact forces are in good agreement. Copyright (C) 1996 Elsevier Science Ltd.
Resumo:
Sickle-cell disease is the most prevalent genetic disease in the Brazilian population. Lower limb ulcers are the most frequent cutaneous complications, affecting 8% to 10% of the patients. These ulcers are usually deep and may take many years to heal. Evidence about the effectiveness of systemic or topical treatment of these wounds is limited, apart from stabilization of the anemia. A 28-year old woman with sickle-cell disease was admitted for treatment of three deep chronic lower leg ulcers. All wounds had tendon exposure and contained firmly adherent fibrin slough. Following surgical debridement and before grafting, the wounds were managed with three different dressings: a rayon and normal saline solution dressing, a calcium alginate dressing covered with gauze, and negative pressure therapy. All three wounds healed successfully and their grafts showed complete integration; only the rayon-dressed wound required a second debridement. The alginate and rayon-dressed wounds recurred after 9 months and required additional skin grafts. Helpful research on managing ulcers in patients with sickle-cell disease is minimal, but the results of this case study suggest that topical treatment modalities may affect outcomes. Research to explore the safety and effectiveness of NPT in patients with sickle-cell wounds is warranted.
Resumo:
This anatomical study examines the anatomic topography and landmarks for localization of the spinal accessory nerve (SAN) during surgical dissections in 40 fresh human cadavers (2 females and 38 males; ages from 22 to 89 years with a mean of 60 years). In the submandibular region, the SAN was found anteriorly to the transverse process of the atlas in 77.5% of the dissections. When the SAN crossed the posterior belly of the digastric muscle, the mean distance from the point of crossing to the tendon of the muscle was 1.75 +/- 0.54 cm. Distally, the SAN crossed between the two heads of the SCM muscle in 45% of the dissections and deep to the muscle in 55%. The SAN exited the posterior border of the sternocleidomastoid muscle in a point superior to the nerve point with a mean distance between these two anatomic parameters of 0.97 +/- 0.46 cm. The mean overall extracranial length of the SAN was 12.02 +/- 2.32 cm, whereas the mean length of the SAN in the posterior triangle was 5.27 +/- 1.52 cm. There were 2-10 lymph nodes in the SAN chain. In conclusion, the nerve point is one of the most reliable anatomic landmarks for localization of the SAN in surgical neck dissections. Although other anatomic parameters including the transverse process of the atlas and the digastric muscle can also be used to localize the SAN, the surgeon should be aware of the possibility of anatomic variations of those parameters. Similar to previous investigations, our results suggest that the number of lymph nodes of the SAN chain greatly varies. Clin. Anat. 22:471-475, 2009. (c) 2009 Wiley-Liss, Inc.
Resumo:
The involvement of the peripheral nervous system in diverse autoimmune diseases is well established. However, no appropriately designed studies have been performed in primary antiphospholipid syndrome (PAPS)-related peripheral neuropathy. We aimed to investigate the occurrence of peripheral neuropathy in patients diagnosed with PAPS. Twenty-six consecutive patients with PAPS (Sapporo criteria) and 20 age-and gender-matched healthy controls were enrolled at two referral centers. Exclusion criteria were secondary causes of peripheral neuropathy. A complete clinical neurologic exam followed by nerve conduction studies (NCS) was performed. Paresthesias were reported in eight patients (31%). Objective mild distal weakness and abnormal symmetric deep tendon reflexes were observed in three patients (11.5%). With regard to the electrophysiologic evidence of peripheral neuropathy, nine patients (35.0%) had alterations: four (15.5%) had pure sensory or sensorimotor distal axonal neuropathy (in two of them a carpal tunnel syndrome was also present) and one (4%) had sensorimotor demyelinating and axonal neuropathy involving upper and lower extremities, while four patients (15.5%) showed isolated carpal tunnel syndrome. Clinical and serologic results were similar in all the patients with PAPS, regardless of the presence of electrophysiologic alterations. In conclusion, peripheral neuropathy is a common asymptomatic abnormality in patients with PAPS. The routine performance of NCS may be considered when evaluating such patients. Lupus (2010) 19, 583-590.
Resumo:
The dynamics of mechanical milling in a vibratory mill have been studied by means of mechanical vibration, shock measurements, computer simulation and microstructural evolution measurements. Two distinct modes of ball motion during milling, periodic and chaotic vibration, were observed. Mill operation in the regime of periodic vibration, in which each collision provides a constant energy input to milled powders, enabled a quantitative description of the effect of process parameters on system dynamics. An investigation of the effect of process parameters on microstructural development in an austenitic stainless steel showed that the impact force associated with collision events is an important process parameter for characterizing microstructural evolution. (C) 1997 Elsevier Science S.A.
Resumo:
Introduction: The use of allograft is a matter of huge interest for orthopaedic surgeons, due to the supposed advantages with its use, like decreased surgical time, larger grafts and no donator site morbidity. Objectives: The aim of this article was to review our experience with the use of allografts on ligament reconstruction. We present the technique applied for graft harvest, preparation and storage, as well as the indications for allograft use and the type of procedure in which it was applied. Methods: We revised the records of 46 patients. Results: We used 09 patellar tendons, 09 anterior tibial tendons, 08 calcaneal tendons, 06 quadriceptal tendons and 01 fibular tendon, mainly for multiple ligamentar reconstructions and ACL reviews. Conclusion: The use of allograft seems to be an interesting option for ligamentar reconstruction.
Resumo:
Objective. Refractory, disabling pain associated with knee osteoarthritis (OA) is usually treated with total knee replacement. However, pain in these patients might be associated with central nervous sensitization rather than peripheral inflammation and injury. We evaluated the presence of hyperalgesia in patients scheduled for a total knee replacement due to knee osteoarthritis with refractory pain, and we assessed the impact of pressure pain threshold measurements (PPT) on pain, disability, and quality of life of these patients. Methods. Sixty-two female patients were compared with 22 age-matched healthy controls without reported pain for the last year. PPT was measured at the lower extremities subcutaneous dermatomes, over the vastus medialis, adductor longus, rectus femoris, vastus lateralis, tibialis anterior, peroneus longus, iliacus, quadratus lumborum and popliteus muscles and at the supraspinous ligaments from L1-L5, over the L5-S1 and S1-S2 sacral areas and at the pes anserinus bursae and patellar tendon. Results. Patients with knee OA had significantly lower PPT over all evaluated structures versus healthy control subjects (P < 0.001). Lower PPT values were correlated with higher pain intensity, higher disability scores, and with poorer quality of life, except for the role-emotional and general health status. Combined PPT values over the patellar tendon, at the S2 subcutaneous dermatome and at the adductor longus muscle were the best predictors for visual analog scale and Western Ontario and McMaster Universities Osteoarthritis Index pain scores. Conclusion. Patients with pain due to osteoarthritis who were scheduled for total knee replacement showed hyperalgesia of nervous system origin that negatively impacted pain, knee functional capacity, and most aspects of quality of life.
Resumo:
To investigate the effect of earlier triceps surae (TS) surgical lengthening at knee kinematics in the stance phase in patients with cerebral palsy (CP). One thousand and thirty-nine participants from an eligible total of 1750 children with CP were referred to gait analysis laboratory from January 2000 to April 2007. Inclusion criteria were the diagnosis of diparetic spastic CP levels I to III (GMFCS) and complete kinematics documentation. Patients with an asymmetrical knee pattern at kinematics and with different types of TS management among sides were excluded. The patients were divided into two groups according to the mean minimum knee flexion (MMKF) in stance phase: group A (n = 253) MMKF >= 30 degrees and group B (n = 786) MMKF less than 30 degrees. For each group, the occurrence of following procedures for TS in the past: (i) earlier surgery, (ii) gastrocnemius lengthening (zone I), (iii) gastrocnemius and soleus lengthening (zone II), and (iv) calcaneous tendon lengthening (zone III), was investigated. A chi(2) test was applied to check if the number of procedures performed was different between groups. The level of significance was defined as P value of less than 0.05. The number of patients with no earlier surgeries at TS was higher in group B (51.8%) than in group A (39.1%), and this difference was significant (P<0.01). In addition, the number of procedures at the calcaneous tendon was more elevated in group A (36.8%) than in group B (27%), and this finding was statistically significant as well (P<0.02). The percentage of surgical lengthening at zones I and II was very similar between the groups A and B. This study has shown that patients without earlier surgical procedures at TS are more susceptible to reach better extension of the knees in the stance phase. Patients in a crouch gait had a higher number of calcaneous tendon lengthening performed in the past than patients with a more normal knee extension in the stance phase. J Pediatr Orthop B 19:226-230 (C) 2010 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
Resumo:
Purpose: The objective of this study was to analyze and compare the results obtained after 2 types of treatment, surgical and conservative, for acute patellar dislocations. Methods: We divided 33 patients with acute patellar dislocations into 2 groups. One group with 16 patients underwent conservative treatment (immobilization and subsequent physiotherapy), and the other group with 17 patients underwent surgical treatment. A radiographic examination was performed in the evaluation of the patients to verify predisposing factors for patellofemoral instability, and the Kujala questionnaire was applied with the intention of analyzing the improvement of pain and quality of life. The chi(2) test, t test, and Fisher test were used in the statistical evaluation. A significance level of P<.05 was adopted. Results: The groups were considered parametric in relation to age and sex. The conservative treatment group exhibited a higher number of recurrent dislocations (8 patients) than the surgical treatment group, which did not have any relapses. In addition, the surgical treatment group obtained a better mean score on the Kujala test (92) than the conservative treatment group (69). Conclusions: We conclude that surgical treatment afforded better results. There were no recurrences in the surgical treatment group, but there were 8 recurrences in the conservative treatment group. The mean Kujala score was 92 in the surgical treatment group and 69 in the conservative treatment group.
Resumo:
To obtain a high quality EMG acquisition, the signal must be recorded as far away as possible from muscle innervations and tendon zones, which are known to shift during dynamic contractions. This study describes a methodology, using commercial bipolar electrodes, to identify better electrode positions for superficial EMG of lower limb muscles during dynamic contractions. Eight female volunteers participated in this study. Myoelectric signals of the vastus lateralis, gastrocnemius medialis, peroneus longus and tibialis anterior muscles were acquired during maximum isometric contractions using bipolar electrodes. The electrode positions of each muscle were selected assessing SENIAM and then, other positions were located along the length of muscle up and down the SENIAM site. The raw signal (density), the linear envelopes, the RMS value, the motor point site, the position of the IZ and its shift during dynamic contractions were taken into account to select and compare electrode positions. For vastus lateralis and peroneus longus, the best sites were 66% and 25% of muscle length, respectively (similar to SENIAM location). The position of the tibialis anterior electrodes presented the best signal at 47.5% of its length (different from SENIAM location). The position of the gastrocnemius medialis electrodes was at 38% of its length and SENIAM does not specify a precise location for signal acquisition. The proposed method should be considered as another methodological step in every EMG study to guarantee the quality of the signal and subsequent human movement interpretations. (C) 2009 Elsevier B.V. All rights reserved.