963 resultados para System parameters


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The demand for cooling and air-conditioning of building is increasingly ever growing. This increase is mostly due to population and economic growth in developing countries, and also desire for a higher quality of thermal comfort. Increase in the use of conventional cooling systems results in larger carbon footprint and more greenhouse gases considering their higher electricity consumption, and it occasionally creates peaks in electricity demand from power supply grid. Solar energy as a renewable energy source is an alternative to drive the cooling machines since the cooling load is generally high when solar radiation is high. This thesis examines the performance of PV/T solar collector manufactured by Solarus company in a solar cooling system for an office building in Dubai, New Delhi, Los Angeles and Cape Town. The study is carried out by analyzing climate data and the requirements for thermal comfort in office buildings. Cooling systems strongly depend on weather conditions and local climate. Cooling load of buildings depend on many parameters such as ambient temperature, indoor comfort temperature, solar gain to the building and internal gains including; number of occupant and electrical devices. The simulations were carried out by selecting a suitable thermally driven chiller and modeling it with PV/T solar collector in Polysun software. Fractional primary energy saving and solar fraction were introduced as key figures of the project to evaluate the performance of cooling system. Several parametric studies and simulations were determined according to PV/T aperture area and hot water storage tank volume. The fractional primary energy saving analysis revealed that thermally driven chillers, particularly adsorption chillers are not suitable to be utilizing in small size of solar cooling systems in hot and tropic climates such as Dubai and New Delhi. Adsorption chillers require more thermal energy to meet the cooling load in hot and dry climates. The adsorption chillers operate in their full capacity and in higher coefficient of performance when they run in a moderate climate since they can properly reject the exhaust heat. The simulation results also indicated that PV/T solar collector have higher efficiency in warmer climates, however it requires a larger size of PV/T collectors to supply the thermally driven chillers for providing cooling in hot climates. Therefore using an electrical chiller as backup gives much better results in terms of primary energy savings, since PV/T electrical production also can be used for backup electrical chiller in a net metering mechanism.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Solar plus heat pump systems are often very complex in design, with sometimes special heat pump arrangements and control. Therefore detailed heat pump models can give very slow system simulations and still not so accurate results compared to real heat pump performance in a system. The idea here is to start from a standard measured performance map of test points for a heat pump according to EN 14825 and then determine characteristic parameters for a simplified correlation based model of the heat pump. By plotting heat pump test data in different ways including power input and output form and not only as COP, a simplified relation could be seen. By using the same methodology as in the EN 12975 QDT part in the collector test standard it could be shown that a very simple model could describe the heat pump test data very accurately, by identifying 4 parameters in the correlation equation found. © 2012 The Authors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this paper is to assess the progress of the banking sector before and shortly after the Real Plan. We began by assessing the drop in the inflation revenues (negative real interest rates paid by the excess of demand deposits over total reserve requirements) as a result of the change in inflation from 40% a month for the pre-Real Plan period to a monthly average of 3.65% (IGP-DI), between July 1994 and May 1995. Then, using the financial statement data of a group of 90 banks, we attempt to estimate the net losses due to the inflation drop analyzing the profitability and other parameters of the banking industry. The calculations are made separately for private, state and federal banks. A later analysis on performance using information given to CVM (Securities Exchange Commission) by the six major private banks in the country is also discussed herein.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The thesis introduces a system dynamics Taylor rule model of new Keynesian nature for monetary policy feedback in Brazil. The nonlinear Taylor rule for interest rate changes con-siders gaps and dynamics of GDP growth and inflation. The model closely tracks the 2004 to 2011 business cycle and outlines the endogenous feedback between the real interest rate, GDP growth and inflation. The model identifies a high degree of endogenous feedback for monetary policy and inflation, while GDP growth remains highly exposed to exogenous eco-nomic conditions. The results also show that the majority of the monetary policy moves during the sample period was related to GDP growth, despite higher coefficients of inflation parameters in the Taylor rule. This observation challenges the intuition that inflation target-ing leads to a dominance of monetary policy moves with respect to inflation. Furthermore, the results suggest that backward looking price-setting with respect to GDP growth has been the dominant driver of inflation. Moreover, simulation exercises highlight the effects of the new BCB strategy initiated in August 2011 and also consider recession and inflation avoid-ance versions of the Taylor rule. In methodological terms, the Taylor rule model highlights the advantages of system dynamics with respect to nonlinear policies and to the stock-and-flow approach. In total, the strong historical fit and some counterintuitive observations of the Taylor rule model call for an application of the model to other economies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Three assays were carried out to determine the digestible methionine+cystine (Met+Cys) requirement for ISA Label broilers from both sexes. The birds were reared in free range system on starting phase (1 to 28 days), growing phase (28 to 56 days) and finishing phase (56 to 84 days). Four hundred and eighty birds were distributed into 24 pens, each one composed of shelter (3.13 m(2)) and pasture (72.87 m(2)). The experimental design was completely randomized with eight treatments as factorial arrangement (four Met+Cys levels and two sexes) with three replicates of 20 birds. The digestible Met+Cys levels were 0.532; 0.652; 0.772; 0.892% for starting phase; 0.515; 0.635; 0.755; 0.875% for growing phase and 0.469; 0.589; 0.709; 0.829% for finishing phase. The analyzed parameters were performance, carcass yield, body protein and fat deposition, weight and protein concentration in feathers. In the starting phase, the digestible Met+Cys level estimated for males was 0.765 and 0.803% for females, corresponding to 0.252 and 0.268% of Met+Cys/Mcal of ME, respectively. For the growing phase, the digestible Met+Cys level estimated was 0.716% for both sexes, corresponding to 0.235% of Met+Cys/Mcal of ME. For the finishing phase, the Met+Cys levels were 0.756 and 0.597% for males and females, corresponding to 0.244 and 0.193% of Met+Cys/Mcal of ME respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Algumas culturas têm pouca adaptação ao sistema plantio direto (SPD), em vista da alta compactação da camada superficial do solo. Nesse caso, o mecanismo utilizado na semeadora para a abertura dos sulcos para deposição do fertilizante pode ter grande importância no sentido de facilitar a penetração das raízes. Avaliouse a influência do mecanismo de distribuição de fertilizante e da adubação nitrogenada na cultura do arroz de terras altas (Oryza sativa) no sistema plantio direto. O experimento foi conduzido nos anos agrícolas 2001/2002 e 2002/2003, em Botucatu-SP, Brasil. O delineamento experimental foi em blocos casualizados, com parcelas subdivididas e quatro repetições. As parcelas foram constituídas por dois mecanismos de distribuição de fertilizantes (haste sulcadora e disco duplo). Nas subparcelas, quatro níveis de N foram aplicados em cobertura (0, 40, 80 e 120 kg ha-1). Avaliou-se a profundidade de abertura do sulco e de deposição das sementes, a população de plantas, a altura de plantas, o número de colmos e de panículas m-2, o número total de espiguetas por panícula, a fertilidade das espiguetas, a massa de 1.000 grãos, a matéria seca da parte aérea, a produtividade e o teor de N na folha bandeira. O sucesso no estabelecimento da cultura do arroz de terras altas no SPD nas regiões de inverno seco do Brasil está diretamente ligado ao mecanismo de distribuição das semeadoras-adubadoras. A haste sulcadora promoveu maior profundidade de deposição de sementes, conseqüentemente reduzindo o estande, o número de panículas por área e a produtividade. A aplicação de N em cobertura no arroz de terras altas em SPD proporciona maiores produtividades quando a semeadura é realizada com mecanismo de disco duplo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An oxovanadium-salen complex (NAP-ethylene-bis(salicylidenciminato) oxovanadium) thin film deposited on a graphite-polyurethane electrode was investigated with regard to its potential use for detection of L-dopa in flow injection system. The oxovanadium(IV)/oxovanadium(V) redox couple of the modified electrode was found to mediate the L-dopa oxidation before its use in the FIA system. Experimental parameters, such as pH of the carrier solution, flow rate, sample volume injection and probable interferents were investigated. Under the optimized FIA conditions, the amperometric signal was linearly dependent on the L-dopa concentration over the range 1.0 x 10(-1) to 1.0 x 10(-4) mol L-1 (I-anodic, mu A) = 0.01 + 0.25 [L-dopa mu mol L-1]) with a detection limit (S/N = 3) of 8.0 x 10(-7) mol L-1 and a sampling frequency of 90 h(-1) was achieved. For a concentration of 1.0 x 10(-5) mol L-1 L-dopa, the R.S.D. of nine consecutive measurements was 3.7%. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we study the local codimension one and two bifurcations which occur in a family of three-dimensional vector fields depending on three parameters. An equivalent family, depending on five parameters, was recently proposed as a new chaotic system with a Lorenz-like butterfly shaped attractor and was studied mainly from a numerical point of view, for particular values of the parameters, for which computational evidences of the chaotic attractor was shown. In order to contribute to the understand of this new system we present an analytical study and the bifurcation diagrams of an equivalent three parameter system, showing the qualitative changes in the dynamics of its solutions, for different values of the parameters. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)