986 resultados para Mitral Valve
Resumo:
The closing sounds of mechanical heart valves can be disturbing for patients and their closest relatives. Although some investigations into mechanical heart valve sounds have been performed, the particularities of the valve sound when it is attached to a vascular prosthesis to replace the aortic root and the ascending aorta has not been studied to date. The study aim was to compare the closing sounds of three various mechanical composite graft prostheses, and to analyze the impact of such sounds on the patients' quality of life.
Resumo:
The conventional surgical aortic bioprostheses used for treatment of aortic stenosis (AS) are inherently stenotic in nature. The more favorable mechanical profile of the Medtronic CoreValve bioprosthesis may translate into a better hemodynamic and neurohormonal response.
Resumo:
A 91-year-old female patient presented with worsening exertional dyspnea 1 month after transfemoral aortic valve implantation using an Edwards Sapien valve. She was found to have a paraprosthetic sinus of Valsalva rupture with a left-to-right shunt into the right ventricular cavity. The patient underwent coil closure of the defect with successful shunt elimination.
Resumo:
To date, transapical aortic valve implantation has required a balloon-expandable stented valve prosthesis. More recently, a novel self-expanding sutureless stented bovine pericardial prosthesis has been developed which allows rapid aortic valve replacement via an open transaortic approach in humans. The aim of this animal study was to develop a reliable protocol to facilitate the transapical implantation of this self-expanding valve in a porcine model.
Resumo:
The aim of this study was to assess the influence of amount and distribution of calcifications of the aortic valve and the left ventricular outflow tract on the acute procedural outcome of patients undergoing transcatheter aortic valve implantation (TAVI).
Resumo:
The 3f Enable aortic bioprosthesis (ATS Medical, Inc, Minneapolis, Minn) represents a new generation of equine pericardial self-expanding valve designed for sutureless implantation. This study evaluated technical aspects of implantation and safety and effectiveness of the valve in the short term.
Resumo:
Background Transcatheter aortic valve implantation (TAVI) is a treatment option for high-risk patients with severe aortic stenosis. Previous reports focused on a single device or access site, whereas little is known of the combined use of different devices and access sites as selected by the heart team. The purpose of this study is to investigate clinical outcomes of TAVI using different devices and access sites. Methods A consecutive cohort of 200 patients underwent TAVI with the Medtronic CoreValve Revalving system (Medtronic Core Valve LLC, Irvine, CA; n = 130) or the Edwards SAPIEN valve (Edwards Lifesciences LLC, Irvine, CA; n = 70) implanted by either the transfemoral or transapical access route. Results Device success and procedure success were 99% and 95%, respectively, without differences between devices and access site. All-cause mortality was 7.5% at 30 days, with no differences between valve types or access sites. Using multivariable analysis, low body mass index (<20 kg/m2) (odds ratio [OR] 6.6, 95% CI 1.5-29.5) and previous stroke (OR 4.4, 95% CI 1.2-16.8) were independent risk factors for short-term mortality. The VARC-defined combined safety end point occurred in 18% of patients and was driven by major access site complications (8.0%), life-threatening bleeding (8.5%) or severe renal failure (4.5%). Transapical access emerged as independent predictor of adverse outcome for the Valve Academic Research Consortium–combined safety end point (OR 3.3, 95% CI 1.5-7.1). Conclusion A heart team–based selection of devices and access site among patients undergoing TAVI resulted in high device and procedural success. Low body mass index and history of previous stroke were independent predictors of mortality. Transapical access emerged as a risk factor for the Valve Academic Research Consortium–combined safety end point.
Resumo:
Gerbode's defect, a left ventricular-to-right atrial communication, with involvement of the tricuspid valve acquired after bacterial endocarditis can be challenging to repair. We report a modified technique for a shunt closure and reconstruction of the tricuspid valve using a plicated bovine pericardial patch. Combining such a repair with a left ventricular patch resulted in a complete defect closure and competent tricuspid valve without regurgitation.
Resumo:
Transcatheter aortic valve implantation (TAVI) is an alternative to surgery for high-risk patients with severe aortic valve stenosis. Periprocedural stroke is reported at an incidence up to 10%. Magnetic resonance imaging studies have identified new onset of clinically silent ischaemic cerebral lesions more frequently (68-84%). So far, few data are available about cerebral embolism during TAVI. The aim of this study was to determine the frequency of high-intensity transient signals (HITS) and to explore differences in the HITS pattern between transfemoral and transapical access and between self-expanding (SE) and balloon-expandable (BE) deployment technique.