956 resultados para Laser induced damage


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Observation of laser induced two-photon photoemission optogalvanic (TPPOG) effect from tungsten electrode in a discharge cell using 564 nm radiation obtained from a pulsed dye laser is described. The magnitude of the POG signal is studied as a function of laser energy under various discharge parameters. Competition between one-photon and two-photon processes has been observed when nitrogen gas is used in the discharge cell.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The changes in emission characteristics of a neon hollow cathode discharge by resonant laser excitation of 1s 5→2p 2 and 1s 5→2p 4 transition have been studied by simultaneously monitoring the optogalvanic effect and the laser induced fluorescence. It has been observed that resonant excitation causes substantial variation in the relative intensities of lines in the emission spectrum of neon discharge.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This work deals with the optical properties of supported noble metal nanoparticles, which are dominated by the so-called Mie resonance and are strongly dependent on the particles’ morphology. For this reason, characterization and control of the dimension of these systems are desired in order to optimize their applications. Gold and silver nanoparticles have been produced on dielectric supports like quartz glass, sapphire and rutile, by the technique of vapor deposition under ultra-high vacuum conditions. During the preparation, coalescence is observed as an important mechanism of cluster growth. The particles have been studied in situ by optical transmission spectroscopy and ex situ by atomic force microscopy. It is shown that the morphology of the aggregates can be regarded as oblate spheroids. A theoretical treatment of their optical properties, based on the quasistatic approximation, and its combination with results obtained by atomic force microscopy give a detailed characterization of the nanoparticles. This method has been compared with transmission electron microscopy and the results are in excellent agreement. Tailoring of the clusters’ dimensions by irradiation with nanosecond-pulsed laser light has been investigated. Selected particles are heated within the ensemble by excitation of the Mie resonance under irradiation with a tunable laser source. Laser-induced coalescence prevents strongly tailoring of the particle size. Nevertheless, control of the particle shape is possible. Laser-tailored ensembles have been tested as substrates for surface-enhanced Raman spectroscopy (SERS), leading to an improvement of the results. Moreover, they constitute reproducible, robust and tunable SERS-substrates with a high potential for specific applications, in the present case focused on environmental protection. Thereby, these SERS-substrates are ideally suited for routine measurements.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The first direct observation of a hyperfine splitting in the optical regime is reported. The wavelength of the M1 transition between the F = 4 and F = 5 hyperfine levels of the ground state of hydrogenlike ^209 Bi^82+ was measured to be \lamda_0 = 243.87(4) nm by detection of laser induced fluorescence at the heavy-ion storage ring ESR at GSI. In addition, the lifetime of the laser excited F = 5 sublevel was determined to be \tau_0 = 0.351(16) ms. The method can be applied to a number of other nuclei and should allow a novel test of QED corrections in the previously unexplored combination of strong magnetic and electric fields in highly charged ions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Many ultrafast structural phenomena in solids at high fluences are related to the hardening or softening of particular lattice vibrations at lower fluences. In this paper we relate femtosecond-laser-induced phonon frequency changes to changes in the electronic density of states, which need to be evaluated only in the electronic ground state, following phonon displacement patterns. We illustrate this relationship for a particular lattice vibration of magnesium, for which we—surprisingly—find that there is both softening and hardening as a function of the femtosecond-laser fluence. Using our theory, we explain these behaviours as arising from Van Hove singularities: We show that at low excitation densities Van Hove singularities near the Fermi level dominate the change of the phonon frequency while at higher excitations Van Hove singularities that are further away in energy also become important. We expect that our theory can as well shed light on the effects of laser excitation of other materials.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Die laserinduzierte Plasmaspektroskopie (LIPS) ist eine spektrochemische Elementanalyse zur Bestimmung der atomaren Zusammensetzung einer beliebigen Probe. Für die Analyse ist keine spezielle Probenpräparation nötig und kann unter atmosphärischen Bedingungen an Proben in jedem Aggregatzustand durchgeführt werden. Femtosekunden Laserpulse bieten die Vorteile einer präzisen Ablation mit geringem thermischen Schaden sowie einer hohen Reproduzierbarkeit. Damit ist fs-LIPS ein vielversprechendes Werkzeug für die Mikroanalyse technischer Proben, insbesondere zur Untersuchung ihres Ermüdungsverhaltens. Dabei ist interessant, wie sich die initiierten Mikrorisse innerhalb der materialspezifschen Struktur ausbreiten. In der vorliegenden Arbeit sollte daher ein schnelles und einfach zu handhabendes 3D-Rasterabbildungsverfahren zur Untersuchung der Rissausbreitung in TiAl, einer neuen Legierungsklasse, entwickelt werden. Dazu wurde fs-LIPS (30 fs, 785 nm) mit einem modifizierten Mikroskopaufbau (Objektiv: 50x/NA 0.5) kombiniert, welcher eine präzise, automatisierte Probenpositionierung ermöglicht. Spektrochemische Sensitivität und räumliches Auflösungsvermögen wurden in energieabhängigen Einzel- und Multipulsexperimenten untersucht. 10 Laserpulse pro Position mit einer Pulsenergie von je 100 nJ führten in TiAl zum bestmöglichen Kompromiss aus hohem S/N-Verhältnis von 10:1 und kleinen Lochstrukturen mit inneren Durchmessern von 1.4 µm. Die für das Verfahren entscheidende laterale Auflösung, dem minimalen Lochabstand bei konstantem LIPS-Signal, beträgt mit den obigen Parametern 2 µm und ist die bislang höchste bekannte Auflösung einer auf fs-LIPS basierenden Mikro-/Mapping-Analyse im Fernfeld. Fs-LIPS Scans von Teststrukturen sowie Mikrorissen in TiAl demonstrieren eine spektrochemische Sensitivität von 3 %. Scans in Tiefenrichtung erzielen mit denselben Parametern eine axiale Auflösung von 1 µm. Um die spektrochemische Sensitivität von fs-LIPS zu erhöhen und ein besseres Verständnis für die physikalischen Prozesse während der Laserablation zu erhalten, wurde in Pump-Probe-Experimenten untersucht, in wieweit fs-Doppelpulse den laserinduzierten Abtrag sowie die Plasmaemission beeinflussen. Dazu wurden in einem Mach-Zehnder-Interferometer Pulsabstände von 100 fs bis 2 ns realisiert, Gesamtenergie und Intensitätsverhältnis beider Pulse variiert sowie der Einfluss der Materialparameter untersucht. Sowohl das LIPS-Signal als auch die Lochstrukturen zeigen eine Abhängigkeit von der Verzögerungszeit. Diese wurden in vier verschiedene Regimes eingeteilt und den physikalischen Prozessen während der Laserablation zugeordnet: Die Thermalisierung des Elektronensystems für Pulsabstände unter 1 ps, Schmelzprozesse zwischen 1 und 10 ps, der Beginn des Abtrags nach mehreren 10 ps und die Expansion der Plasmawolke nach über 100 ps. Dabei wird das LIPS-Signal effizient verstärkt und bei 800 ps maximal. Die Lochdurchmesser ändern sich als Funktion des Pulsabstands wenig im Vergleich zur Tiefe. Die gesamte Abtragsrate variiert um maximal 50 %, während sich das LIPS-Signal vervielfacht: Für Ti und TiAl typischerweise um das Dreifache, für Al um das 10-fache. Die gemessenen Transienten zeigen eine hohe Reproduzierbarkeit, jedoch kaum eine Energie- bzw. materialspezifische Abhängigkeit. Mit diesen Ergebnissen wurde eine gezielte Optimierung der DP-LIPS-Parameter an Al durchgeführt: Bei einem Pulsabstand von 800 ps und einer Gesamtenergie von 65 nJ (vierfach über der Ablationsschwelle) wurde eine 40-fache Signalerhöhung bei geringerem Rauschen erzielt. Die Lochdurchmesser vergrößerten sich dabei um 44 % auf (650±150) nm, die Lochtiefe um das Doppelte auf (100±15) nm. Damit war es möglich, die spektrochemische Sensitivität von fs-LIPS zu erhöhen und gleichzeitig die hohe räumliche Auflösung aufrecht zu erhalten.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper reports the surface morphologies and ablation of crystalline silicon wafers irradiated by infra-red 775 nm Ti:sapphire femtosecond laser. The effects of energy fluences (below and above single-pulse modification) with different number of pulses were studied. New morphological features such as pits, cracks formation, Laser-Induced Periodic Surface Structures (LIPSS) and ablation were observed. The investigation indicated that there are two distinct mechanisms under femtosecond laser irradiation: low fluence regime with different morphological features and high fluence regime with high material removal and without complex morphological features.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this work was to examine a possible association between resistance of two Escherichia coli strains to high hydrostatic pressure and the susceptibility of their cell membranes to pressure-induced damage. Cells were exposed to pressures between 100 and 700 MPa at room temperature (~20C) in phosphate-buffered-saline. In the more pressure-sensitive strain E. coli 8164, loss of viability occurred at pressures between 100 MPa and 300 MPa and coincided with irreversible loss of membrane integrity as indicated by uptake of propidium iodide (PI) and leakage of protein of molecular mass between 9 and 78 kDa from the cells. Protein release increased to a maximum at 400 MPa then decreased, possibly due to intracellular aggregation at the higher pressures. In the pressure-resistant strain E. coli J1, PI was taken up during pressure treatment but not after decompression indicating that cells were able to reseal their membranes. Loss of viability in strain J1 coincided with the transient loss of membrane integrity between approximately 200 MPa and 600 MPa. In E. coli J1 leakage of protein occurred before loss of viability and the released protein was of low molecular mass, between 8 and 11 kDa and may have been of periplasmic origin. In these two strains differences in pressure resistance appeared to be related to differences in the ability of their membranes to withstand disruption by pressure. However it appears that transient loss of membrane integrity during pressure can lead to cell death irrespective of whether cells can reseal their membranes afterwards.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The effect of glucose on the intracellular pH (pH(i)) recovery rate (dpH(i)/dt) and Na(+)-glucose transporter (SGLT) localization was investigated in HEK-293 cells, a cell line that expresses endogenous NHE1, NHE3, SGLT1, and SGLT2 proteins. The activity of the Na(+)/H(+) exchangers (NHEs) was evaluated by using fluorescence microscopy. The total and membrane protein expression levels were analyzed by immunoblotting. In cells cultivated in 5 mM glucose, the pH(i) recovery rate was 0.169 +/- A 0.020 (n = 6). This value did not change in response to the acute presence of glucose at 2 or 10 mM, but decreased with 25 mM glucose, an effect that was not observed with 25 mM mannitol. Conversely, the chronic effect of high glucose (25 mM) increased the pH(i) recovery rate (similar to 40%, P < 0.05), without changes in the total levels of NHE1, NHE3, or SGLT1 expression, but increasing the total cellular (similar to 50%, P < 0.05) and the plasma membrane (similar to 100%, P < 0.01) content of SGLT2. Treatment with H-89 (10(-6) M) prevented the stimulatory effect of chronic glucose treatment on the pH(i) recovery rate and SGLT2 expression in the plasma membrane. Our results indicate that the effect of chronic treatment with a high glucose concentration is associated with increased NHEs activity and plasma membrane expression of SGLT2 in a protein kinase A-dependent way. The present results reveal mechanisms of glucotoxicity and may contribute to understanding the diabetes-induced damage of this renal epithelial cell.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The protective effect of short-term creatine supplementation (CrS) upon markers of strenuous contractile activity-induced damage in human and rat skeletal muscles was investigated. Eight Ironman triathletes were randomized into the placebo (Pl; n = 4) and creatine-supplemented (CrS; n = 4) groups. Five days prior to the Ironman competition, the CrS group received creatine monohydrate (20 g day(-1)) plus maltodextrin (50 g) divided in two equal doses. The Pl group received maltodextrin (50 g day(-1)) only. The effect of CrS (5 g day(-1)/kg body weight for 5 days) was also evaluated in a protocol of strenuous contractile activity induced by electrical stimulation in rats. Blood samples were collected before and 36 and 60 h after the competition and were used to determine plasma activities of creatine kinase (CK), lactate dehydrogenase (LDH), aldolase (ALD), glutamic oxaloacetic acid transaminase (GOT), glutamic pyruvic acid transaminase (GPT), and C-reactive protein (CRP) level. In rats, plasma activities of CK and LDH, muscle vascular permeability (MVP) using Evans blue dye, muscle force and fatigue were evaluated. Activities of CK, ALD, LDH, GOT, GTP, and levels of CRP were increased in the Pl group after the competition as compared to basal values. CrS decreased plasma activities of CK, LDH, and ALD, and prevented the rise of GOT and GPT plasma activities. In rats, CrS delayed the fatigue, preserved the force, and prevented the rise of LDH and CK plasma activities and MVP in the gastrocnemius muscle. CrS presented a protective effect on muscle injury induced by strenuous contractile activities.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The propagation of an optical beam through dielectric media induces changes in the refractive index, An, which causes self-focusing or self-defocusing. In the particular case of ion-doped solids, there are thermal and non-thermal lens effects, where the latter is due to the polarizability difference, Delta alpha, between the excited and ground states, the so-called population lens (PL) effect. PL is a pure electronic contribution to the nonlinearity, while the thermal lens (TL) effect is caused by the conversion of part of the absorbed energy into heat. In time-resolved measurements such as Z-scan and TL transient experiments, it is not easy to separate these two contributions to nonlinear refractive index because they usually have similar response times. In this work, we performed time-resolved measurements using both Z-scan and mode mismatched TL in order to discriminate thermal and electronic contributions to the laser-induced refractive index change of the Nd3+-doped Strontium Barium Niobate (SrxBa1-xNb2O6) laser crystal. Combining numerical simulations with experimental results we could successfully distinguish between the two contributions to An. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Changes in activities of Cu-Zn superoxide dismutase (SOD- E.C.1.15.1.1.) and lactate dehydrogenase (LDH- E.C.1.1.1.27.) and levels of copper, total protein, triglycerides, phospholipids and total lipids were investigated in pancreas of rats after intratracheal administration of NiCl2 (8.4 mumol/kg). Nickel chloride induced increased SOD activity in pancreas and erythrocytes. This elevation was related to increased copper and decreased phospholipid content in pancreas of these animals. In conclusion, the ability of an animal to tolerate nickel chloride induced damage was governed by a delicate balance between the generation of cytotoxic agents and the various pancreas defense capabilities.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents the theoretical and experimental results for oxide thin film growth on titanium films previously deposited over glass substrate. Ti films of thickness 0.1 μm were heated by Nd:YAG laser pulses in air. The oxide tracks were created by moving the samples with a constant speed of 2 mm/s, under the laser action. The micro-topographic analysis of the tracks was performed by a microprofiler. The results taken along a straight line perpendicular to the track axis revealed a Gaussian profile that closely matches the laser's spatial mode profile, indicating the effectiveness of the surface temperature gradient on the film's growth process. The sample's micro-Raman spectra showed two strong bands at 447 and 612 cm -1 associated with the TiO 2 structure. This is a strong indication that thermo-oxidation reactions took place at the Ti film surface that reached an estimated temperature of 1160 K just due to the action of the first pulse. The results obtained from the numerical integration of the analytical equation which describes the oxidation rate (Wagner equation) are in agreement with the experimental data for film thickness in the high laser intensity region. This shows the partial accuracy of the one-dimensional model adopted for describing the film growth rate. © 2001 Elsevier Science B.V.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Structural Health Monitoring (SHM) denotes a system with the ability to detect and interpret adverse changes in a structure. One of the critical challenges for practical implementation of SHM system is the ability to detect damage under changing environmental conditions. This paper aims to characterize the temperature, load and damage effects in the sensor measurements obtained with piezoelectric transducer (PZT) patches. Data sets are collected on thin aluminum specimens under different environmental conditions and artificially induced damage states. The fuzzy clustering algorithm is used to organize the sensor measurements into a set of clusters, which can attribute the variation in sensor data due to temperature, load or any induced damage.