695 resultados para LOCALIZED CORROSION
Resumo:
The literature dealing with the electrochemical corrosion characteristics of unalloyed copper in aqueous chloride media is examined. The enormous quantity of polarisation and mixed/corrosion potential data that has been made available in the literature over the last 50 years has been compiled and discussed in a comprehensive review. For a wide range of electrode geometries, the importance of the chloride ion and the mass transport of anodic corrosion products on the corrosion behaviour of copper are made clear for both freshly polished and 'filmed' surfaces. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
The age hardening, stress corrosion cracking (SCC) and hydrogen embrittlement (HE) of an Al-Zn-Mg-Cu 7175 alloy were investigated experimentally. There were two peak-aged states during ageing. For ageing at 413 K, the strength of the second peak-aged state was slightly higher than that of the first one, whereas the SCC susceptibility was lower, indicating that it is possible to heat treat 7175 to high strength and simultaneously to have high SCC resistance. The SCC susceptibility increased with increasing Mg segregation at the grain boundaries. Hydrogen embrittlement (HE) increased with increased hydrogen charging and decreased with increasing ageing time for the same hydrogen charging conditions. Computer simulations were carried out of (a) the Mg grain boundary segregation using the embedded atom method and (b) the effect of Mg and H segregation on the grain boundary strength using a quasi-chemical approach. The simulations showed that (a) Mg grain boundary segregation in Al-Zn-Mg-Cu alloys is spontaneous, (b) Mg segregation decreases the grain boundary strength, and (c) H embrittles the grain boundary more seriously than does Mg. Therefore, the SCC mechanism of Al-Zn-Mg Cu alloys is attributed to the combination of HE and Mg segregation induced grain boundary embrittlement. (C) 2004 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Resumo:
An investigation was carried out into the galvanic corrosion of magnesium alloy AZ91D in contact with zinc, aluminium alloy A380 and 4150 steel. Specially designed test panels were used to measure galvanic currents under salt spray conditions. It was found that the distributions of the galvanic current densities on AZ91D and on the cathodes were different. An insulating spacer between the AZ91D anode and the cathodes could not eliminate galvanic corrosion. Steel was the worst cathode and aluminium the least aggressive to AZ91D. Corrosion products from the anode and cathodes appeared to be able to affect the galvanic corrosion process through an alkalisation, passivation, poisoning effect or shortcut effect. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
Corrosion of magnesium engine components by coolant is an important issue in the automotive industry where magnesium alloys may be used. It is of significance to understand the corrosion behaviour of pure magnesium in ethylene glycol solutions, as this can provide a basis for developing new coolants for magnesium alloy engine blocks. In this paper, through corrosion and electrochemical tests, it was found that the corrosion rate of magnesium decreased with increasing concentration of ethylene glycol. Individual contaminants, such as NaCl, NaHCO3, Na2SO4 and NaCl can make aqueous ethylene glycol solution more corrosive to magnesium. However, in NaCl contaminated ethylene glycol, NaHCO3 and Na2SO4 showed some inhibition effect. The solution resistivity played an important role in the corrosion of magnesium in ethylene glycol solutions, and the competitive adsorption of ethylene glycol and the contaminants on the magnesium surface was also responsible for the observed corrosion behaviours. The corrosion of magnesium in ethylene glycol can be effectively inhibited by addition of fluorides that react with magnesium and form a protective film on the surface. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
The corrosion behaviour of die cast magnesium alloy AZ91D aged at 160degreesC was investigated. The corrosion rate of the alloy decreases with ageing time in the initial stages and then increases again at ageing times greater than 45 h. The dependence of the corrosion rate on ageing time can be related to the changes in microstructure and local composition during ageing. Precipitation of the beta phase (Mg17Al12) occurs exclusively along the grain boundaries during ageing. The beta phase acts as a barrier, resulting in a decreasing corrosion rate in the initial stages of ageing. In the later stages, the decreasing aluminium content of alpha grains makes the alpha matrix more active, causing an increase in the corrosion rate. Electrochemical testing results also confirm the combined effects of the changes in alpha and beta phases on the corrosion resistance of the aged die cast AZ91D alloy. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
Objectives. To undertake a prospective longitudinal study to assess psychological and decision-related distress after the diagnosis of localized prostate cancer. Methods. A total of I 11 men (93% response rate) with localized prostate cancer were recruited from outpatient urology clinics and urologists' private practices. More than one half (56%) elected to undergo radical prostatectomy, 19% underwent external beam radiotherapy, and 25% chose watchful waiting. Men completed self-report measures before treatment and 2 and 12 months after treatment. The measures used included the University of California, Los Angeles, Prostate Cancer Index, International Prostate Symptom Score, Impact of Events Scale, Constructed Meaning Scale, Satisfaction with Life Scale, Health Care Orientation subscale, and Decisional Conflict Scale. Results. No statistically significant differences were found by medical treatment group in the psychological and decision-related adjustment at baseline or with time. Men who were undecided about their treatment choice had greater decisional conflict and a more negative healthcare orientation, but were not more psychologically distressed, compared with men who had decided. At diagnosis, 63% of men had high decision-related distress, and this persisted for 42% of men 12 months after treatment, despite high satisfaction with their treatment choice. At diagnosis, low-to-moderate psychological distress was most common, with distress decreasing after treatment. The overall quality of life was similar to community norms. Conclusions. The results of our study indicated that men who were undecided about what treatment to receive experienced greater decision-related distress. The final treatment choice was not related to psychological distress about prostate cancer. Psychological and decision-related distress decreased with time, independent of treatment modality. Interventions should target decision-related distress for all men and in-depth psychological support for those who experience ongoing difficulties. (C) 2004 Elsevier Inc.
Resumo:
Stress corrosion cracks (SCC) had been found in a natural gas transmission pipeline during a dig-up and inspection program. The question was raised as to whether the SCC was active or dormant. This paper describes the resultant investigation to determine if a particular service crack was actively growing. The strategy adopted was to assess the appearance of the fracture surface of the service crack and to compare with expectations from laboratory specimens with active SCC. The conclusions from this study are as follows. To judge whether a crack in the service pipe is active or dormant, it is reasonable to compare the very crack tip of the service crack and a fresh crack in a laboratory sample. If the crack tip of the active laboratory sample is similar to that of the service pipe, it means the crack in the service pipe is likely to be active. From the comparison of the crack tip between the service pipe and the laboratory samples, it appears likely that the cracks in the samples extracted from service were most likely to have been active intergranular stress corrosion cracks. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
To investigate the effects of different management strategies for non-localized prostate cancer on men's quality of life and cognitive functioning. Men with prostate cancer were randomly assigned to one of four treatment arms: leuprorelin, goserelin, cyproterone acetate (CPA), or close clinical monitoring. In a repeated-measures design, men were assessed before treatment (baseline) and after 6 and 12 months of treatment. A community comparison group of men of the same age with no prostate cancer participated for the same length of time. The men were recruited from public and private urology departments from university teaching hospitals. All those with prostate cancer who were eligible for hormonal therapy had no symptoms requiring immediate therapy. In all, 82 patients were randomized and 62 completed the 1-year study, and of the 20 community participants, 15 completed the study. The main outcome measures were obtained from questionnaires on emotional distress, existential satisfaction, physical function and symptoms, social and role function, subjective cognitive function, and sexual function, combined with standard neuropsychological tests of memory, attention, and executive functions. Sexual dysfunction increased for patients on androgen-suppressing therapies, and emotional distress increased in those assigned to CPA or close clinical monitoring. Compared with before treatment there was evidence of an adverse effect of leuprorelin, goserelin, and CPA on cognitive function. In deciding the timing of androgen suppression therapy for prostate cancer, consideration should be given to potential adverse effects on quality of life and cognitive function.
Resumo:
Although the use of alternative therapies is highly prevalent amongst men with prostate cancer, research about the predictors of such use is limited. The current study aimed to describe prospectively the use of alternative therapies by men diagnosed with localized prostate cancer and identify predictors of alternative therapy use. In all, 111 men newly diagnosed with localized prostate cancer (93% response) were recruited to the study prior to treatment. Men's use of alternative therapies and psychological variables including: psychological distress, orientation to health care, decisional conflict, and health locus of control, were assessed at three time points-(1) before treatment; (2) 2 months after completion of treatment; and (3) 12 months after completion of treatment. Demographic information was also obtained. The percentage of men using alternative therapies was 25, 17 and 14% before treatment, 2 and 12 months after treatment, respectively. In general, the most commonly used therapies were dietary changes, vitamins and herbal and nutrient remedies. Alternative therapy use was not related to final treatment choices. Before treatment, men who used alternative therapies were more uncertain about prostate cancer compared to men who were not using these therapies. Men who were using alternative therapies 12 months after treatment were less psychologically distressed that men who were not using these therapies. Health locus of control and orientation to health care were not found to be related to men's use of alternative therapies. In conclusion, men's use of alternative therapies after localized prostate cancer varied across time in terms of the incidence of use, the types of therapies used, and the psychological correlates of therapy use. Informational support that targets uncertainty about prostate cancer may assist men at diagnosis who are considering alternative therapy use. The potential for alternative therapies to have a supportive function in patient care requires further investigation. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
Resumo:
We describe a method to produce local heating or cooling (depending on how the system is tuned) in a mesoscopic device by transport of electrons. The mechanism can operate on molecules or quantum dots, or any system where the local modes are coupled to vibrations. We believe this will be of future interest in micro electro mechanical systems (MEMS). The amount of heating/cooling obtained depends on the details of the device. We also perform a numerical calculation to display the effect. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Sorting nexins are a large family of proteins that contain the phosphoinositide-binding Phox homology (PX) domain. A number of sorting nexins are known to bind to PtdIns(3)P, which mediates their localization to membranes of the endocytic pathway. We show here that sorting nexin 5 (SNX5) can be recruited to two distinct membrane compartments. In non-stimulated cells, the PX domain was independently targeted to endosomal structures and colocalized with full-length SNX5. The membrane binding of the PX domain was inhibited by the PI 3-kinase inhibitor, wortmannin. Although SNX5 colocalized with a fluid-phase marker and was found predominantly within a PtdIns(3)P-rich endosomal domain, very little colocalization was observed between SNX5 and the PtdIns(3)P-binding protein, EEA1. Using liposome-based binding assays, we have shown that the PX domain of SNX5 interacts not only with PtdIns(3)P but also with PtdIns(3,4)P-2. In response to EGF stimulation, either the SNX5-PX domain or full-length SNX5 was rapidly recruited to the plasma membrane. The localization of SNX1, which does not bind PtdIns(3,4)P-2, was unaffected by EGF signalling. Therefore, SNX5 is localized to a subdomain of the early endosome distinct from EEA1 and, following EGF stimulation and elevation of PtdIns(3,4)P-2, is also transiently recruited to the plasma membrane. These results indicate that SNX5 may have functions not only associated with endosomal sorting but also with the phosphoinositide-signalling pathway.
Understanding the corrosion mechanism: a framework for improving the performance of magnesium alloys
Resumo:
High pressure die casting is the most important production method for casting magnesium alloy components, and uniformity of appearance is an important criterion for acceptance of a component by customers. This paper investigates the influence of uniformity in surface appearance of diecast AZ91D plates on their corrosion behaviour. Through immersion, hydrogen collection and weight loss measurements it was found that corrosion is more likely to occur on the areas of the plate that appear to be darker, leading to a non-uniformly corroded surface. Microstructural analysis showed that the non-uniformity in appearance is related to a difference in the morphology and distribution of porosity across the surface of a diecast AZ91D plate. The darker areas of the surface are high in porosity which breaks the continuity of the beta-phase network and provides shortcut paths for corrosion from the surface to the interior of the casting. The brighter shiny areas of the surface are much less porous, with isolated pores being confined by corrosion resistant beta-precipitates thus reducing the corrosion rate.