833 resultados para Hot plate


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several countries have been passed by change processes in their fundamental geodesic structure with the focus on the adoption of geocentric reference systems. In Brazil, the adoption of the SIRGAS2000 evolves the coexistence of two realizations from the COrrego Alegre system, two realizations from the SAD69 system and one realization from the SIRGAS2000 system. To make use of products in the old reference systems, methods of coordinate transformation between the existent reference frames are necessary. So, in this paper one solution for the transformation between coordinates from different reference frames, based on Thin-Plate Splines (TPS), that allows the estimation of parameters from one linear transformation and also one non-linear model is presented. The TPS model was developed to work with tridimensional coordinates and in this paper the results and analysis are performed with simulated data and also with data from the official Brazilian Geodetic System (SGB). In the check points from SAD69 stations (realization of 1996 - SAD69/96), the values of RMSE obtained were of 78,2 mm in latitude and 67,5 mm in longitude, before the transformation to the SIRGAS2000. In the comparison between the TPS model and ProGriD (Brazilian software provided by IBGE), the statistical indicators were reduced in 97%, by using the TPS model. Based in the obtained results from real dataset, the TPS model appears to be promising, since it allows improving the quality of transformation process with simultaneous distortion modeling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the 1950s, fatigue is the most important project and operational consideration for both civil and military aircrafts. For some aircraft models the most loaded component is one that supports the motor: the Motor Cradle. Because they are considered critical to the flight safety the aeronautic standards are extremely rigorous in manufacturing them by imposing a zero index of defects on the final weld quality (Safe Life), which is 100% inspected by Non-Destructive Testing/NDT. This study has as objective to evaluate the effects of up to four successive TIG welding repairs on the axial fatigue strength of an AISI 4130 steel. Tests were conducted on hot-rolled steel plate specimens, 0.89 mm thick, with load ratio R = 0.1, constant amplitude, at 20 Hz frequency and in room temperature, in accordance with ASTM E466 Standard. The results were related to microhardness and microstructural and geometric changes resulting from welding cycles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A possible way for increasing the cutting tool life can be achieved by heating the workpiece in order to diminish the shear stress of material and thus decrease the machining forces. In this study, quartz electrical resistances were set around the workpiece for heating it during the turning. In the tests, heat-resistant austenitic alloy steel was used, hardenable by precipitation, mainly used in combustion engine exhaustion valves, among other special applications for industry. The results showed that in the hot machining the cutting tool life can be increased by 340% for the highest cutting speed tested and had a reduction of 205% on workpiece surface roughness, accompanied by a force decrease in relation to conventional turning. In addition, the chips formed in hot turning exhibited a stronger tendency to continuous chip formation indicating less energy spent in material removal process. Microhardness tests performed in the workpieces subsurface layers at 5 m depth revealed slightly higher values in the hot machining than in conventional, showing a tendency toward the formation of compressive residual stress into plastically deformed layer. The hot turning also showed better performance than machining using cutting fluid. Since it is possible to avoid the use of cutting fluid, this machining method can be considered better for the environment and for the human health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soil CO2 efflux is the primary source of CO2 emissions from terrestrial ecosystems to the atmosphere. The rates of this flux vary in time and space producing hot moments (sudden temporal high fluxes) and hot spots (spatially defined high fluxes), but these high reaction rates are rarely studied in conjunction with each other. We studied temporal and spatial variation of soil CO2 efflux in a water-limited Mediterranean ecosystem in Baja California, Mexico. Soil CO2 efflux increased 522% during a hot moment after rewetting of soils following dry summer months. Monthly precipitation was the primary driver of the seasonal trend of soil CO2 efflux (including the hot moment) and through changes in soil volumetric water content (VWC) it influenced the relationship between CO2 efflux and soil temperature. Geostatistical analyses showed that the spatial dependence of soil CO2 efflux changed between two contrasting seasons (dry and wet). During the dry season high soil VWC was associated with high soil CO2 efflux, and during the wet season the emergence of a hot spot of soil CO2 efflux was associated with higher root biomass and leaf area index. These results suggest that sampling designs should accommodate for changes in spatial dependence of measured variables. The spatio-temporal relationships identified in this study are arguably different from temperate ecosystems where the majority of soil CO2 efflux research has been done. This study provides evidence of the complexity of the mechanisms controlling the spatio-temporal variability of soil CO2 efflux in water-limited ecosystems. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare the hard tissue changes at implants installed applying edentulous ridge expansion (E.R.E.) at sites with a buccal bony wall thickness of 1 or 2 mm.Material and methods: In six Labrador dogs, the first and second maxillary incisors were extracted, and the buccal alveolar bony plates and septa were removed. After 3 months of healing, partial-thickness flaps were dissected, and the E.R.E. was applied bilaterally. Hence, an expansion of the buccal bony crest was obtained in both sides of the maxilla with a displacement of either a 1- or a 2-mm-wide buccal bony plate at the test and control sites, respectively. After 3 months of healing, biopsies were obtained for histological analyses.Results: A buccal vertical resorption of the alveolar crest of 2.3 +/- 0.8 and 2.1 +/- 1.1 mm, and a coronal level of osseointegration at the buccal aspect of 2.7 +/- 0.5 and 2.9 +/- 0.9 mm were found at the test (1 mm) and control (2 mm) sites, respectively. The differences did not reach statistical significance. The mean values of the mineralized bone-to-implant contact (MBIC%) ranged from 62% to 73% at the buccal and lingual sites. No statistically significant differences were found. Horizontal volume gains of 1.8 and 1.1 mm were observed at the test and control sites, respectively, and the difference being statistically significant.Conclusions: Implants installed using the E.R.E. technique yielded a high degree of osseointegration. It is suggested that the displacement of buccal bony plates of 1 mm thickness is preferable compared with that of wider dimensions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The properties of the hot melt adhesive pressure sensitive (HMPSA) using an elastomer as a base polymer a copolymer of styrene and butadiene (SBS) and variation of tackifiers resins such as hydrocarbon resins and hydrogenated hydrocarbon were investigated. The formulations were prepared by mixing process within shear. The adhesives prepared were evaluated in test Brookfield viscosity and softening point Ring and Ball to compare the formulations and the influence of variations in raw materials. Infrared analyzes were performed to detect the reactions between the inputs and investigate the chemical interactions of the same properties of the adhesive. In thermal analysis, the assay was performed thermogravimetry (TG) and diferencial exploratory calorimetry (DSC). Were investigated the parameters of the tensile test on each of the formulations. Finally, were analysed comparatively the basic formulations of adhesives with their respective raw materials

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Shearplate is an optical glass plate having two flat surfaces and a small angle between them. The use of a high quality shear plate is essential to implement shear interferometric technique . The shear interferometry is a technique used to evaluate the light beam collimation. In order to guarantee the shearplate quality , the complete manufacturing process must be thoroughly monitored. In the manufacturing process, the first step consisted of the glass selection. The selected glass has been submitted to the process of cutting, gluing, chamfering, grinding and polishing. Each phase has been strictly monitored. The quality of the final result depends extremely on an appropriate starting condition, which arises from the grinding process, as the polishing process only recovers the brightness of the part, acting on a small scale on the wearing off of the part, as well as not changing the structured obtained in the grinding process. Respecting all stages of the manufacturing process, the quality of the part has evolved to a good result. The best result obtained showed PV distance of 162 nm, slightly less than λ / 4. This result is significant because the dimensions of the piece with respect to the dimensions of the polisher what interferes directly in the results. The closer are the dimensions of piece and the dimensions of the polisher, the greater the difficulty in controlling the propagation of errors

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The objective of this article is to describe a method to construct an intraoralacrylic device that permits a reline material to be added to the inner surface of thepalatal plate.Materials and Methods: Fifteen 60-day-old adult female rats (Rattus NorvegicusAlbinus Wistar), weighing 150 to 250 g were used for this study and allocated to threegroups (n = 5): G1, animals wearing a heat-polymerized acrylic resin palatal plate(Lucitone 550) for 14 days; G2, animals wearing a heat-polymerized acrylic resinpalatal plate (Lucitone 550) relined with Tokuyama Rebase II for 14 days; and G3,animals maintained under the same conditions as the experimental groups, withoutwearing palatal plates for 14 days. The manipulation of the animals followed theguidelines of the Brazilian College of Animal Experimentation, under the approval ofthe animal ethics committee of the State University of Ponta Grossa. The palatal platescovered the whole palate, were fixed in the molar region with light-cured resin, andwere kept there for 14 days. The animals received a paste diet and water ad libitum.Before and after the trial period, the rats were weighed individually on a precisionscale. Statistical analysis was performed using a two-way analysis of variance (α =0.05) test for comparison of the animals’ weight (g) at time 0 and after 14 days ofusing the palatal plate.Results: No statistical differences were observed regarding the weight of the animalsamong the experimental groups in the study.Conclusions: The individual master impressions, the molar teeth coverage, and themethod of cementation with nonadhesive composite resin provided good stability forthe palatal plate showed in this study, not disturbing the eating habits and nutritionof the animals. This model seems reproducible, offering adequate histopathologicalevaluation. Differences in tissue morphology exist between the animals that used thepalatal plate and the animals that did not use this device. Use of these palatal platescould clarify how prostheses bring changes in the palatal mucosa of users.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although measurement errors can impair statistical analysis, reliability analysis has been neglected in applied microbiology. This study assessed the intra-rater reproducibility of the Agar-based method for estimation of phospholipase activity (Pz). Pz readings were performed twice by two examiners (E1, E2), either directly on plates or in photos, and both black and white backgrounds were used. Pz values were taken from one or triplicate colonies from each sample (n=30). Intra-examiner reproducibility was estimated using Intraclass Correlation Coefficient (ICC). For both examiners, reading triplicate (ICCE1=0.91, ICCE2=0.86) was better than one colony (ICCE1=0.86, ICCE2=0.80). E1 had an excellent concordance when measurements were performed on photos using a white background (ICC=0.95) and a good concordance in the other conditions