991 resultados para Física de plasma
Resumo:
This paper reports the studies conducted on removal of oxides of nitrogen (NOx) from diesel engine exhaust using electrical discharge plasma combined with adsorbing materials such as molecular sieves. This study is being reported for the first time. The exhaust is taken from a diesel engine of 6 kW under no load conditions. The characteristic behavior of a pulse energized dielectric barrier discharge reactor in the diesel exhaust treatment is reported. The NOx removal was not significant (36%) when the reactor without any packing was used. However, when the reactor was packed with molecular sieves (MS -3A, -4A & -13X), the NOx removal efficiency was increased to 78% particularly at a temperature of 200 °C. The studies were conducted at different temperatures and the results were discussed.
Resumo:
A single-stage plasma-catalytic reactor in which catalytic materials were packed was used to remove nitrogen oxides. The packing material was scoria being made of various metal oxides including Al2O3, MgO, TiO2, etc. Scoria was able to act not only as dielectric pellets but also as a catalyst in the presence of reducing agent such as ethylene and ammonia. Without plasma discharge, scoria did not work well as a catalyst in the temperature range of 100 °C to 200 °C, showing less than 10% of NOx removal efficiency. When plasma is produced inside the reactor, the NOx removal efficiency could be increased to 60% in this temperature range.
Resumo:
This paper reports improved performance of discharge plasma in raw engine exhaust treatment. For the purpose of investigation, both filtered and raw diesel engine exhaust were separately treated by the discharge plasma. In raw exhaust environment, the discharge plasma exhibits a superior performance with regard to NOx removal, energy consumption and formation of by-products. In this study, experiments were conducted at conditions of different temperatures and loads.
Resumo:
A detailed study on the removal of oxides of nitrogen (NOx) from the exhaust of a stationary diesel engine was carried out using nonthermal-plasma (pulsed electrical-discharge plasma)-promoted catalytic process. In this paper, the filtered exhaust from the diesel engine is made to pass through a combination of nonthermal plasma reactor and a catalytic reactor connected in series. This combination is referred to as cascade. Two types of cascaded systems were studied. In one type, the plasma treating filtered exhaust was cascaded with a reduction catalyst V2O5/TiO2 using ammonia as reducing agent, and in the other type, the plasma treating filtered exhaust was cascaded with activated-alumina catalyst without any additive. Improved NOx-removal performance of both the cascaded processes and the role of nonthermal plasma in promoting catalysis are explained. Along with the NOx, total hydrocarbon and aldehydes were also removed. Furthermore, experiments were conducted at different temperatures and engine-loading conditions.
Resumo:
This paper proposes a compact electric discharge plasma source for controlling NOX emission in diesel engine exhaust. Boost converter is used to boost to solar powered battery voltage to 24V, further an automobile ignition coil was used to generate the high voltage pulse using fly-back topology. This design is aimed at retrofitting the existing catalytic converters with pulse assisted cleaning technique. In this paper we bring out a relative comparison of discharge plasma and plasma-adsorbent process at different gas flow rates. Activated alumina was used as adsorbent. The main emphasis is laid on the development of a compact pulse source from 12V battery, which is powered by the solar, for the removal of NOX from the filtered diesel engine exhaust.
Resumo:
Synthesis of methanol using pulsed discharge plasma process is gaining significance. We report the production of methanol from methane and CO2/H2O, using pulsed discharge. Experiments were conducted at very low temperature (-192°C) in addition to normal room temperature. Two types of plasma reactors, cylindrical and rectangular, were tested for methanol production with different corona electrodes (straight wire, helical wire and barbed plate). Gas analysis was carried out by GC-MS and the yield of methanol at various operating conditions was compared and discussed. Experiments were carefully conducted laboratory environment
Resumo:
Application of pulsed plasma for gas cleaning is gaining prominence in recent years mainly from the energy consideration point of view. Normally, gas treatment is carried out, at or above room temperature, by a conventional dry type corona reactor. However, this treatment is still inadequate in the removal of certain stable gases present in the exhaust/flue gas mixture. The authors report some interesting results of the treatment of such stable gases with pulsed plasma at very low ambient temperature. Also reported in the paper is an improvement in DeNO/DeNOx efficiency using unconventional wet-type reactors, designed and fabricated by the authors, operating at different ambient temperatures. Apart from laboratory tests on simulated gas mixtures, field tests were also carried out on the exhaust gas of a 8 kW diesel engine. Further, an attempt was made to test the feasibility of a helical wire as a corona electrode in place of the conventional straight wire electrode. A comparative analysis of the various tests is presented together with a note on the energy consideration
Resumo:
Conversion of hydrocarbon fuels to methanol promoted their efficient utilization as methanol can easily be converted to hydrogen gas, which has higher available energy. In this regard, nonthermal plasma approach using electrical discharges is gaining significance to improve the conversion process of methanol. The efficiency of this nonthermal plasma chemical reaction is affected by various chemical and electrical parameters. This paper presents some important results of the parametric study carried out in methanol synthesis with the aim of reducing energy losses associated with the conventional method. The parameters include the concentration of the reactants, corona electrode configurations, gas mixtures, etc. Further, an attempt was made to study the combined effect of catalysts and electrical discharges on methanol synthesis. Main emphasis was laid on the electrical aspects like electric field, power transfer efficiency, etc. The gas analysis was carried out under carefully maintained laboratory conditions
Resumo:
Application of non-thermal plasma for gas cleaning is gaining prominence in the recent years. Normally, the gas treatment was carried out at or above room temperature, by the dry type plasma reactor. However, this treatment is still inadequate in the removal of certain stable gases present in the flue gas mixture. We propose the non-thermal plasma process at very low temperature, and report here some interesting results of treatment of NO or N2O with pulsed plasma below — 100°C ambient temperature. Direct methanol synthesis from CH4 and CO2 at very low temperature is also reported. A comparative analysis of the various tests are presented together with a note on the energy consideration
Resumo:
The discharge plasma-chemical hybrid process for NO/sub x/ removal from the due gas emissions is an extremely effective and economical approach in comparison with the conventional selective catalytic reduction system. In this paper we bring out a relative comparison of several discharge plasma reactors from the point of NO removal efficiency. The reactors were either energized by AC or by repetitive pulses. Ferroelectric pellets were used to study the effect of pellet assisted discharges on gas cleaning. Diesel engine exhaust, at different loads, is used to approximately simulate the due gas composition. Investigations were carried out at room temperature with respect to the variation of reaction products against the discharge power. Main emphasis is laid on the oxidation of NO to NO/sub 2/, without reducing NOx concentration (i.e., minimum reaction byproducts), with least power consumption. The produced NO/sub 2/ will be totally converted to N/sub 2/ and Na/sub 2/SO/sub 4/ using Na/sub 2/SO/sub 3/. The AC packed bed reactor and pelletless pulsed corona reactor showed better performance, with minimum reaction products for a given power, when the NO concentration was low (/spl sim/100 ppm). At high engine loads (NO>300 ppm) there was not much decrease in NO/sub x/ reduction and more or less all the reactors performed equally. The paper discusses these observations in detail.