929 resultados para Edge detector


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flow-mode static and dynamic laser light scattering (SLS/DLS) studies of polymers, including polystyrene, polyethylene, polypropylene and poly(dimethylsiloxane) (PDMS), in 1,2,4-trichlorobenzene (TCB) at 150 degreesC were performed on a high temperature gel permeation chromatography (GPC) coupled with a SLS/DLS detector. Both absolute molecular weight (M) and molecular sizes (radius of gyration, R-g and hydrodynamic radius, R-h) of polymers eluting from the GPC columns were obtained simultaneously. The conformation of different polymers in TCB at 150 degreesC were discussed according to the scaling relationships between R-g, R-h and M and the rho-ratio (p = R-g/R-h). Flow-mode DLS results of PDMS were verified by batch-mode DLS study of the same sample. The presented technique was proved to be a convenient and quick method to study the shape and conformation of polymers in solution at high temperature. However, the flow-mode DLS was only applicable for high molecular weight polymers with a higher refractive index increment such as PDMS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report capillary electrophoresis coupling to a solid-state electrochemiluminescence (ECL) detector for the first time. The solid-state ECL detector was fabricated by immobilizing the ECL reagent tris(2,2'-bipyridyf)ruthenium (TBR) in poly-(p-styrenesulfonate)-silica-poly(vinyl alcohol) grafting 4-vinylpyridine copolymer films. The excellent stability of the solid-state ECL detector in the phosphate solution satisfied application in CE. The CE with solid-state ECL detector system was characterized using tripropylamine (TPA) and proline. The influences of detection potential, the concentration of TBR in the film, and pH value of ECL buffer were investigated. The linear range for TPA and proline was 0.005-10 muM and 5-10 mM with correlation coefficients of 0.997 and 0.998, respectively. The detection limit (signal-to-noise ratio S/N = 3) was estimated to be 0.002 and 2.0 muM for TPA and proline, respectively. The relative standard deviations for 1.0 pm TPA and 1.0 mm proline were 8.7% and 7.5% with theoretical plate numbers of 70 000 and 16 000, respectively. Compared with the CE-ECL of TBR in aqueous solution, the CE coupling with solid-state ECL detector system gave the same sensitivity of analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

VUV-UV and Eu-L-3 edge XANES spectra were measured for europium-doped strontium tetraborate prepared by solid state reaction at high temperature in air. The VUV-UV spectra show that the host absorption band of (SrBO7)-O-4 appears below 170 nm. The charge transfer band of Eu3+ doped in SrB4O7 is peaked at 272 nm. The 4f-5d transitions of Eu2+ consist of a band peaked at 310 nm with a shoulder at 280 nm and also include the bands peaked at 238 (weak) and 203 (strong) nm. The result of XANES spectrum at Eu-L3 edge of the synthesized sample indicates that Eu3+ and Eu2+ coexist in SrB4O7:Eu prepared in air, which is consistent with the results of the VUV-UV spectra.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The local structure and the valences of europium in SrBPO5:Eu prepared in air were checked by means of XAFS at Eu-L-3 edge. From the EXAFS results, it was discovered that the doped europium atoms were nine-coordinated by oxygen atoms and the distances of bond Eu-O were 2.42 Angstrom in the host. From the XANES data, it was found that the divalent and trivalent europium coexisted in the matrix. The emission spectra excited by VUV or UV exhibited a prominent broad band due to the 4f(6)5d-4f(7) transition of Eu2+ ions, which indicated that the trivalent europium ions were reduced in air in the matrix at high temperature by the defects [V-Sr]" formed by aliovalent substitution between Sr2+ and Eu3+ ions. The VUV excitation spectra in 100-200 nm range showed that the matrix had absorption bands with the maxima at about 130 and 150 nm, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The luminescent materials SrB4O7:Eu and BaB8O13:Eu were synthesized, and the valence states of europium in the materials were measured by means of XANES at Eu-L-3 edge. It is found that the Ed(3+) and Eu2+ ions are all present in the materials, and more Eu3+ ions can be reduced in SrB4O7:Eu than in BaB8O13:Eu. The excitation and emission spectra of Eu3+ in SrB4O7:Eu and BaB8O13:Eu were determined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three cellulose derivatives were synthesized and used as chiral stationary phases based on silica gel. The effects of adsorbances on the column numbers and stabilities have been investigated. These stationary phases exhibited high chiral recognition for various racemates. At the same time, the on-line curves of polarimeter were obtained by high performance liquid chromatography with polarimeter as on-line detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new electrochemical cell assembly with the combination of UV and amperometric detector (AD) based on their complementarity was described. A Nafion tubing junction was used to decouple the high voltage from the separation capillary in the rear of on-column UV detector. In this mode, the electroactive and inert compounds could be detected by UV and AD at the same time. Aromatic amines were determined with the UV and the end-column AD detection to evaluate the performances of the cell assembly. Such an improved electrochemical detector could match the capillary with different diameters. By simple adjustment of the screws, the positioning of the working electrode and the detection capillary was easily gained without microscope. It is also very easy to assemble and disassemble the working electrode when needed. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrochemistry at the liquid/liquid and liquid/membrane interface has been developed recently. It can be used for a new kind of electrochemical detector and sensor. Some new aspects of the field in this laboratory are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A procedure is described for the preparation of a tubular electrode by chemical deposition of platinum at the end of a fused-silica capillary. The properties of the electrode were tested under liquid chromatographic conditions, demonstrating that both the static and the dynamic behaviour of the detection system satisfy the requirements of capillary chromatographic separations and compare well with a wall-jet amperometric system and with UV photometric detection. The detection system described is easy to prepare and does not require any time-consuming positioning of the electrode system as it is integrated into the separation part of the apparatus. (C) 1998 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reversed-phase high-performance liquid chromatography with series dual glassy carbon electrodes for the amperometric detection of water-soluble menadione is described. The complex post-column derivatization reaction and the high background currents were avoided. The menadione sodium bisulfite was reduced at -0.3 V vs. SCE at the upstream (generator) electrode and oxidized at +0.2V vs. SCE at the downstream (collector) electrode. The mobile phase was 0.2moll(-1) HAc-NaAc aqueous buffer (pH 5.50) and 40% (v/v) methanol. The linear response was in the range of 35 ng to 15 mu g, with a detection Limit of 15 ng (S/N=3). The correlation coefficient was 0.9997 (n=6). The electrochemical detection with series dual electrodes has a higher selectivity for menadione (vitamin K-3) compound than with UV detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chemically modified electrodes (CMEs) prepared by the dispersion of metal oxide particles on a glassy carbon (GC) substrate greatly enhance the voltammetric response and amperometric detection of local anesthetics following liquid chromatography (LC). The enhancement is more pronounced with the GC electrodes dispersed by the metal oxides of higher oxidation states (+3, +4) and for the species exhibiting relatively slow electrode kinetics under given conditions. With an applied potential of 1.2 V (vs. SCE), LC amperometric detection of the analytes at the alpha-alumina modified GC surface gives detection limits 2-5 times lower than those obtained at the bare electrode. The metal oxide-dispersed electrodes display significant improvement in sensitivity, and selectivity and indicate excellent preparation reproducibility and performance stability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dispersion of alumina particles on a glassy-carbon surface serving as a modified electrode significantly enhances the amperometric detection of cysteine and glutathione following liquid chromatography. With an applied potential of 0.8 V vs. SCE, the detection limits were 1.2 ng for cysteine and 8 ng for glutathione and the electrode response was linear up to 600 ng for cysteine and 1.8-mu-g for glutathione. The modified electrode displayed high sensitivity and stability and was easy and inexpensive to prepare.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An electrochemical detector which was constracted by using a carbon fibre electrode in a flow-through cell was connected with a liquid chromatographic column. Thus a sensitive,