914 resultados para Combined Heat and Power (CHP)
Resumo:
Deep-frying, which consists of immersing a wet material in a large volume of hot oil, presents a process easily adaptable to dry rather than cook materials. A suitable material for drying is sewage sludge, which may be dried using recycled cooking oils (RCO) as frying oil. One advantage is that this prepares both materials for convenient disposal by incineration. This study examines fry-drying of municipal sewage sludge using recycled cooking oil. The transport processes occurring during fry-drying were monitored through sample weight, temperature, and image analysis. Due to the thicker and wetter samples than the common fried foods, high residual moisture is observed in the sludge when the boiling front has reached the geometric center of the sample, suggesting that the operation is heat transfer controlled only during the first half of the process followed by the addition of other mechanisms that allow complete drying of the sample. A series of mechanisms comprising four stages (i.e., initial heating accompanied by a surface boiling onset, film vapor regime, transitional nucleate boiling, and bound water removal) is proposed. In order to study the effect of the operating conditions on the fry-drying kinetics, different oil temperatures (from 120 to 180 degrees C), diameter (D = 15 to 25 mm), and initial moisture content of the sample (4.8 and 5.6 kg water(.)kg(-1) total dry solids) were investigated.
Resumo:
In this study, we investigate the fabrication of 3D porous poly(lactic-co-glycolic acid) (PLGA) scaffolds using the thermally-induced phase separation technique. The current study focuses on the selection of alternative solvents for this process using a number of criteria, including predicted solubility. toxicity, removability and processability. Solvents were removed via either vacuum freeze-drying or leaching, depending on their physical properties. The residual solvent was tested using gas chromatography-mass spectrometry. A large range of porous, highly interconnected scaffold architectures with tunable pore size and alignment was obtained, including combined macro- and microporous structures and an entirely novel 'porous-fibre' structure. The morphological features of the most promising poly(lactic-co-glycolic acid) scaffolds were analysed via scanning electron microscopy and X-ray micro-computed tomography in both two and three dimensions. The Young's moduli of the scaffolds under conditions of temperature, pH and ionic strength similar to those found in the body were tested and were found to be highly dependent on the architectures.
Resumo:
In this Study we examine the spectral and morphometric properties of the four important lunar mare dome fields near Cauchy, Arago, Hortensius. and Milichius. We utilize Clementine UV vis mulfispectral data to examine the soil composition of the mare domes while employing telescopic CCD imagery to compute digital elevation maps in order to determine their morphometric properties, especially flank slope, height, and edifice Volume. After reviewing previous attempts to determine topographic data for lunar domes, we propose an image-based 3D reconstruction approach which is based on a combination of photoclinometry and shape from shading. Accordingly, we devise a classification scheme for lunar Marc domes which is based on a principal component analysis of the determined spectral and morphometric features. For the effusive mare domes of the examined fields we establish four Classes, two of which are further divided into two subclasses, respectively, where each class represents distinct combinations of spectral and morphometric dome properties. As a general trend, shallow and steep domes formed out of low-TiO2 basalts are observed in the Hortensius and Milichius dome fields, while the domes near Cauchy and Arago that consist of high-TiO2 basalts are all very shallow. The intrusive domes of our data set cover a wide continuous range of spectral and morphometric quantities, generally characterized by larger diameters and shallower flank slopes than effusive domes. A comparison to effusive and intrusive mare domes in other lunar regions, highland domes, and lunar cones has shown that the examined four mare dome fields display Such a richness in spectral properties and 3D dome shape that the established representation remains valid in a more global context. Furthermore, we estimate the physical parameters of dome formation for the examined domes based on a rheologic model. Each class of effusive domes defined in terms of spectral and morphometric properties is characterized by its specific range of values for lava viscosity, effusion rate, and duration of the effusion process. For our data set we report lava viscosities between about 10(2) and 10(8) Pas, effusion rates between 25 and 600 m(3) s(-1), and durations of the effusion process between three weeks and 18 years. Lava viscosity decreases with increasing R-415/R-750 spectral ratio and thus TiO2 content; however, the correlation is not strong, implying an important influence of further parameters like effusion temperature on lava viscosity.
Resumo:
The performance of a scramjet combustor with combined normal and tangential injection was experimentally investigated. Experiments were performed on a 500-mm cylindrical scramjet combustor at a freestream Mach number of 4.5, a nozzle supply pressure of 35.8 MPa, and a nozzle supply enthalpy of 5.8 MJ/kg. Hydrogen fuel was injected normally through portholes to promote combustion and tangentially through a slot to reduce viscous drag. A series of fuel injectors were used to vary the proportion of tangential to normal fuel between 45 and 100%. Reductions in the viscous drag of up to 25% were observed with the greatest reductions occurring at the lowest total equivalence ratio tested for each injector. However, the average pressure produced by combustion with combined normal and tangential injection was approximately 50% less than that produced by normal injection alone. An analysis of the change in specific impulse of the scramjet combustor indicated that the best overall performance was produced by 100% normal injection.
Resumo:
Objective: To compare the incidence of ventilator-associated pneumonia (VAP) in patients ventilated in intensive care by means of circuits humidified with a hygroscopic heat-and-moisture exchanger with a bacterial viral filter (HME) or hot-water humidification with a heater wire in both inspiratory and expiratory circuit limbs (DHW) or the inspiratory limb only (SHW). Design: A prospective, randomized trial. Setting: A metropolitan teaching hospital's general intensive care unit. Patients: Three hundred eighty-one patients requiring a minimum period of mechanical ventilation of 48 hrs. Interventions: Patients were randomized to humidification with use of an HME (n = 190), SHW (n = 94), or DHW (n = 97). Measurements and Main Results. Study end points were VAP diagnosed on the basis of Clinical Pulmonary Infection Score (CPIS) (1), HME resistance after 24 hrs of use, endotracheal tube resistance, and HME use per patient. VAP occurred with similar frequency in all groups (13%, HME; 14%, DHW; 10%, SHW; p = 0.61) and was predicted only by current smoking (adjusted odds ratio [AOR], 2.1; 95% confidence interval [CI], 1.1-3.9; p =.03) and ventilation days (AOR, 1.05; 95% Cl, 1.0-1.2; p =.001); VAP was less likely for patients with an admission diagnosis of pneumonia (AOR, 0.40; 95% Cl, 0.4-0.2; p =.04). HME resistance after 24 hrs of use measured at a gas flow of 50 L/min was 0.9 cm H2O (0.4-2.9). Endotracheal tube resistance was similar for all three groups (16-19 cm H2O min/L; p =.2), as were suction frequency, secretion thickness, and blood on suctioning (p =.32, p =.06, and p =.34, respectively). The HME use per patient per day was 1.13. Conclusions: Humidification technique does not influence either VAP incidence or secretion characteristics, but HMEs may have air-flow resistance higher than manufacturer specifications after 24 hrs of use.
Resumo:
Aims: To compare treatment outcomes amongst patients offered pharmacotherapy with either naltrexone or acamprosate used singly or in combination, in a 12-week outpatient cognitive behavioural therapy (CBT) programme for alcohol dependence. Methods: We matched 236 patients across gender, age group, prior alcohol detoxification, and dependence severity and conducted a cohort comparison study of three medication groups (CBT+acamprosate, CBT+naltrexone, CBT+combined medication) which included 59 patients per group. Outcome measures included programme attendance, programme abstinence and for those who relapsed, cumulative abstinence duration (CAD) and days to first breach (DFB). Secondary analyses compared the remaining matched 59 subjects who declined medication with the pharmacotherapy groups. Results: Across medication groups, CBT+ combined medication produced the greatest improvement across all outcome measures. Although a trend favoured the CBT+ combined group, differences did not reach statistical significance. Programme attendance: CBT + Acamprosate group (66.1%), CBT + Naltrexone group (79.7%), and in the CBT + Combined group (83.1%). Abstinence rates were 50.8, 66.1, and 67.8%, respectively. For those that did not complete the programme abstinent, the average number of days abstinent (CAD) were 45.07, 49.95, and 53.58 days, respectively. The average numbers of days to first breach (DFB) was 26.79, 26.7, and 37.32 days. When the focal group (CBT + combined) was compared with patients who declined medication (CBT-alone), significant differences were observed across all outcome indices. Withdrawal due to adverse medication effects was minimal. Conclusions: The addition of both medications (naltrexone and acamprosate) resulted in measurable benefit and was well tolerated. In this patient population naltrexone with CBT is as effective as combined medication with CBT, but the trend favours combination medication.