979 resultados para COMET ASSAY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

New rapid first-derivative spectrophotometric (UVDS) and a stability-indicating high performance liquid chromatographic (HPLC) methods were developed, validated and successfully applied in the analysis of loratadine (LT) in tablets and syrups. In the UVDS method, 0.1 M HCl was used as solvent. The measurements were made at 312.4 nm in the first order derivative spectra. The HPLC method was carried out on a RP-18 column with a mobile phase composed of methanol-water-tetrahydrofuran (50:30:20, v/v/v). UV detection was made at 247 nm. For HPLC methods the total analysis time was <3min, adequate for routine quality control of tablets and syrups containing loratadine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to compare the responses of the Salmonella/microsome microsuspension assay with the new microplate fluctuation protocol (MPF) for the evaluation of the mutagenic activity of environmental samples. Organic extracts of total particulate atmospheric air samples, surface waters, and effluents were tested in dose-response experiments. The assays were performed with strain TA98 in the absence and presence of S9 mix. Both protocols produced similar results, despite the fact that the maximum score of the MPF is limited to 48 wells, whereas in the regular plate assay it is possible to count up to 1,500 colonies using an automatic counter. Similar sensitivities based on the lowest dose that resulted in a positive response were obtained for both assays. The MPF procedure is less laborious (e.g., all-liquid format, use of multi-channel pipettors) and allows for automation of the pipetting and dispensing steps, thus, reducing time of the analysis which is particularly important in environmental quality monitoring programs or in effect-directed analysis. The results show that the MPF procedure is a promising tool to test environmental samples for mutagenic activity. Environ. Mol. Mutagen. 51:31-38, 2010. (C) 2009 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method was optimized for the analysis of omeprazole (OMZ) by ultra-high speed LC with diode array detection using a monolithic Chromolith Fast Gradient RP 18 endcapped column (50 x 2.0 mm id). The analyses were performed at 30 degrees C using a mobile phase consisting of 0.15% (v/v) trifluoroacetic acid (TFA) in water (solvent A) and 0.15% (v/v) TFA in acetonitrile (solvent B) under a linear gradient of 5 to 90% B in 1 min at a flow rate of 1.0 mL/min and detection at 220 nm. Under these conditions, OMZ retention time was approximately 0.74 min. Validation parameters, such as selectivity, linearity, precision, accuracy, and robustness, showed results within the acceptable criteria. The method developed was successfully applied to OMZ enteric-coated pellets, showing that this assay can be used in the pharmaceutical industry for routine QC analysis. Moreover, the analytical conditions established allow for the simultaneous analysis of OMZ metabolites, 5-hydroxyomeprazole and omeprazole sulfone, in the same run, showing that this method can be extended to other matrixes with adequate procedures for sample preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive, specific polymerase chain reaction-based assay was developed for the detection of the causal agent of ratoon stunting disease of sugarcane, Clavibacter xyli subsp. xyli. This assay uses oligonucleotide primers derived from the internal transcribed spacer region between the 16S and 23S rRNA genes of the bacterial rRNA operon. The assay is specific for C. xyli subsp. xyli and does not produce an amplification product from the template of the closely related bacterium C. xyli subsp. cynodontis, nor from other bacterial species. The assay was successfully applied to the detection of C. xyli subsp. xyli in fibrovascular fluid extracted from sugarcane and was sensitive to approximately 22 cells per PCR assay. A multiplex PCR test was also developed which identified and differentiated C. xyli subsp. xyli and C. xyli subsp. cynodontis in a single PCR assay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mycophenolic acid is an immunosuppressant administered as a bioavailable ester, mycophenolate mofetil. The pharmacokinetics of mycophenolic acid have been reported to be variable. Accurate measurement of concentrations of this drug could be important to adjust doses. The aim of this study was to compare the enzyme-multiplied immunoassay technique (EMIT [Dade Behring; San Jose, CA, U.S.A.]) for mycophenolic acid with a high-performance liquid chromatographic (HPLC) assay using samples collected from renal transplant recipients. The HPLC assay used solid phase extraction and a C18 stationary phase with ultraviolet (UV) detection (254 nm). The immunoassay required no manual sample preparation. Plasma samples (n = 102) from seven patients, collected at various times after a dose, were analyzed using both methods. Both assays fulfilled quality-control criteria. Higher concentrations were consistently measured in patient samples when using EMIT. The mean (+/- standard deviation [SD]) bias (EMIT-HPLC) was 1.88 +/- 0.86 mg/L. The differences in concentrations were higher in the middle of a dosage interval, suggesting that a metabolite might have been responsible for overestimation. Measurement of glucuronide concentrations by HPLC demonstrated only a weak correlation between assay differences and glucuronide concentrations. If the crossreacting substance is active, EMIT could provide a superior measure of immunosuppression; if inactive, further work is needed to improve antibody specificity. In conclusion, it was found that EMIT overestimates the concentration of mycophenolic acid in plasma samples from renal transplant recipients compared with HPLC analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Azo dyes are of environmental concern due to their degradation products, widespread use, and low-removal rate during conventional treatment. Their toxic properties are related to the nature and position of the substituents with respect to the aromatic rings and amino nitrogen atom. The dyes Disperse Red 1 and Disperse Red 13 were tested for Salmonella mutagenicity, cell viability by annexin V, and propidium iodide in HepG2 and by aquatic toxicity assays using daphnids. Both dyes tested positive in the Salmonella assay, and the suggestion was made that these compounds induce mainly frame-shift mutations and that the enzymes nitroreductase and O-acetyltransferase play an important role in the observed effect. In addition, it was shown that the presence of the chlorine substituent in Disperse Red 13 decreased the mutagenicity about 14 times when compared with Disperse Red 1, which shows the same structure as Disperse Red 13, but without the chlorine substituent. The presence of this substituent did not cause cytotoxicity in HepG2 cells, but toxicity to the water flea Daphnia similis increased in the presence of the chlorine substituent. These data suggest that the insertion of a chlorine substituent could be an alternative in the design of dyes with low-mutagenic potency, although the ecotoxicity should be carefully evaluated. (C) 2010 Wiley Periodicals, Inc. Environ Toxicol 26: 489-497, 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study evaluates the effect of isolated fractions of Harpagophytum procumbens (devil`s claw) on cyclooxygenase (COX-1 and COX-2) activities and NO production using a whole blood assay. The activity of COX-1 was quantified as platelet thromboxane B(2) production in blood clotting and COX-2 as prostaglandin E(2) production in LPS-stimulated whole blood. Total NO(2)(-)/NO(3)(-) concentration was determined by Griess reaction in LPS stimulated blood. Assays were performed by incubation of isolated fractions obtained by flash chromatography monitored with HPLC, TLC and identified by (1)HNMR, containing different amounts of harpagoside with blood from healthy donors. Indomethacin and etoricoxib were the positive controls of COX-1 and COX-2 Inhibition. Data shows that fraction containing the highest concentration of harpagoside inhibited indistinctively COX-1 and COX-2 (37.2 and 29.5% respectively) activity and greatly inhibited NO production (66%). In contrast the fraction including iridoid pool increased COX-2 and did not alter NO and COX-1 activities. The fraction containing cinnamic acid was able to reduce only NO production (67%). Our results demonstrated that the harpagoside fraction is the main responsible for the effect of devils claw on these enzyme activities. However, other components from devil`s claw crude extract could antagonize or increase the synthesis of inflammatory mediators. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sludge produced in sewage treatment plants can contain toxic substances. Among these, the genotoxic substances are of great concern. The present paper aimed at evaluating the genotoxicity of treated sludge samples collected at four different sewage treatment plants (STP) located in the State of Sao Paulo Brazil, using the Trad-MN assay. Another objective of the study was to compare the responses of the Clone #4430 with the Tradescantia pallida. Sludge samples mixed with reference soil in concentrations of 10, 25 and 50% (v/v) were tested in experiments with 3 months exposure in the field. Negative and positive controls (arsenic trioxide) were also tested with both plants. In Clone #4430 two sludge samples induced genotoxicity while in T pallida three were positive, although no clear dose-response were observed for both plants. Results with the negative and positive controls suggest that T pallida presented similar results when compared to the Clone #4430. The protocol using plants chronically exposed to sludge mixed with soil seems to be a promising tool to assess the genotoxicity of sludge although time consuming. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Helicobacter pylori ClariRes assay is a novel commercially available real-time PCR assay allowing H. pylori detection and clarithromycin susceptibility testing in either gastric biopsy or stool specimens. Objective: The aim of this study was to validate the novel biprobe real-time assay in stool specimens from 217 dyspeptic children. Methods: DNA from gastric biopsies and stool specimens were obtained and submitted to the biprobe real time assay for H. pylori detection and clarithromycin susceptibility testing. Results: The sensitivity, specificity, and test accuracy were 69, 100 and 93.9% for the detection of H. pylori infection and 83.3, 100 and 95.6%, for detection of clarithromycin resistance. Conclusion: This assay proved to be appropriate for H. pylori clarithromycin susceptibility testing, particularly in children populations where a high prevalence of clarithromycin-resistant strains is suspected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow cytometry-adapted fluorescent antibody to membrane antigen (FAMA) assay to detect IgG antibodies against varicella-zoster virus (VZV) was developed and tested in 62 serum samples, showing 90.32% accuracy obtained from a receiver operating characteristic (ROC) curve with a 0.9125 (95% confidence interval [CI], 0.829 to 1.00) area below the curve compared to the result with standard FAMA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was designed to examine the use of the QuantiFERON-TB Gold assay as an aid in the diagnosis of active pulmonary tuberculosis (TB) in Brazilian patients. Using the receiver operating characteristic curve, the cutoff was adjusted to >= 0.20 IU/ml. The sensitivity increased to 86%, with 100% specificity. All TB patients with negative sputum smear microscopy and negative culture results were positive using this test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laboratory diagnosis of hantavirus cardiopulmonary syndrome (HCPS) in Brazil has been performed mostly by a detection of IgM antibodies to recombinant antigen purified from Sin Nombre virus and Andes Virus (ANDV). Recently, a recombinant nucleocapsid (rN) protein of Argentina virus (ARAV), a Brazilian hantavirus, was Obtained in Escherichia coli. To evaluate ARAV rN as antigen for antibody detection, serum samples from 30 patients front Argentina seropositive for hantavirus were tested. All samples were positive for IgG and IgM by enzyme-linked immunosorbent assay (ELISA) using either ARAV rN or ANDV rN antigens. In Brazil, six of 00 serum samples from patients With suspected HCPS (10%) were positive for IgM by ELISA Using ARAV rN antigen and 7 were positive Using ANDV rN antigen. For results obtained with 90 serum samples analyzed by IgM ELISA with ANDV rN antigen, the sensitivity of the IgM ELISA using ARAV rN antigen was 97.2%,, the specificity was 100%, the positive predictive value was 100% and the negative predictive value was 98.1%. The results show that ARAV rN is a Suitable antigen for diagnosis Of hantavirus infection in Brazil and Argentina.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examined the correlation between results obtained from the in vivo Draize test for ocular irritation and in vitro results obtained from the sheep red blood cell (RBC) haemolytic assay, which assesses haemolysis and protein denaturation in erythrocytes, induced by cosmetic products. We sought to validate the haemolytic assay as a preliminary test for identifying highly-irritative products, and also to evaluate the in vitro test as alternative assay for replacement of the in vivo test. In vitro and in vivo analyses were carried out on 19 cosmetic products, in order to correlate the lesions in the ocular structures with three in vitro parameters: (i) the extent of haemolysis (H50); (ii) the protein denaturation index (131); and (iii) the H50/DI ratio, which reflects the irritation potential (IP). There was significant correlation between maximum average scores (MAS) and the parameters determined in vitro (r = 0.752-0.764). These results indicate that the RBC assay is a useful and rapid test for use as a screening method to assess the IP of cosmetic products, and for predicting the IP value with a high level of concordance (94.7%). The assay showed high sensitivity and specificity rates of 91.6% and 100%, respectively.