946 resultados para Automobile dealers fittings
Resumo:
A case study of Brisbane, the capital city of Queensland, Australia, explored how explicit measures of transit quality of service (e.g., service frequency, service span, and travel time ratio) and implicit environmental predictors (e.g., topographic grade factor) influenced bus ridership. The primary hypothesis tested was that bus ridership was higher in suburbs with high transit quality of service than in suburbs with limited service quality. Multiple linear regression, used to identify a strong positive relationship between route intensity (bus-km/h-km2) and bus ridership, indicated that both increased service frequency and spatial route density corresponded to higher bus ridership. Additionally, the travel time ratio (i.e., the ratio of in-vehicle transit travel time to in-vehicle automobile travel time) had a significant negative association with suburban ridership: transit use declined as travel time ratio increased. In contrast, topographic grade and service span did not significantly affect suburban bus ridership. The study findings enhance the fundamental understanding of traveler behavior, which is informative to urban transportation policy, planning, and provision.
Resumo:
A vibration isolator is described which incorporates a near-zero-spring-rate device within its operating range. The device is an assembly of a vertical spring in parallel with two inclined springs. A low spring rate is achieved by combining the equivalent stiffness in the vertical direction of the inclined springs with the stiffness of the vertical central spring. It is shown that there is a relation between the geometry and the stiffness of the individual springs that results in a low spring rate. Computer simulation studies of a single-degree-of-freedom model for harmonic base input show that the performance of the proposed scheme is superior to that of the passive schemes with linear springs and skyhook damping configuration. The response curves show that, for small to large amplitudes of base disturbance, the system goes into resonance at low frequencies of excitation. Thus, it is possible to achieve very good isolation over a wide low-frequency band. Also, the damper force requirements for the proposed scheme are much lower than for the damper force of a skyhook configuration or a conventional linear spring with a semi-active damper.
Resumo:
We report the observation of persistent photoconductivity (PPC) in flower shaped PbS dendrites grown by the hydrothermal method. Potential fluctuations, due to the presence of various confinement regimes in the branches of dendrites, and surface traps, are likely responsible for the PPC observed here. We also observed photocurrent quenching and decreased dark current in the PPC below 40 K, due to the presence of a metastable state, whereas positive PPC was observed in the temperature region 40-220 K. Dark conductivity measurements, time constant parameters obtained from the stretched exponential fittings of PPC, also showed the metastable state related transition around 50 K.
Resumo:
Technical or contaminated ethanol products are sometimes ingested either accidentally or on purpose. Typical misused products are black-market liquor and automotive products, e.g., windshield washer fluids. In addition to less toxic solvents, these liquids may contain the deadly methanol. Symptoms of even lethal solvent poisoning are often non-specific at the early stage. The present series of studies was carried out to develop a method for solvent intoxication breath diagnostics to speed up the diagnosis procedure conventionally based on blood tests. Especially in the case of methanol ingestion, the analysis method should be sufficiently sensitive and accurate to determine the presence of even small amounts of methanol from the mixture of ethanol and other less-toxic components. In addition to the studies on the FT-IR method, the Dräger 7110 evidential breath analyzer was examined to determine its ability to reveal a coexisting toxic solvent. An industrial Fourier transform infrared analyzer was modified for breath testing. The sample cell fittings were widened and the cell size reduced in order to get an alveolar sample directly from a single exhalation. The performance and the feasibility of the Gasmet FT-IR analyzer were tested in clinical settings and in the laboratory. Actual human breath screening studies were carried out with healthy volunteers, inebriated homeless men, emergency room patients and methanol-intoxicated patients. A number of the breath analysis results were compared to blood test results in order to approximate the blood-breath relationship. In the laboratory experiments, the analytical performance of the Gasmet FT-IR analyzer and Dräger 7110 evidential breath analyzer was evaluated by means of artificial samples resembling exhaled breath. The investigations demonstrated that a successful breath ethanol analysis by Dräger 7110 evidential breath analyzer could exclude any significant methanol intoxication. In contrast, the device did not detect very high levels of acetone, 1-propanol and 2-propanol in simulated breath. The Dräger 7110 evidential breath ethanol analyzer was not equipped to recognize the interfering component. According to the studies the Gasmet FT-IR analyzer was adequately sensitive, selective and accurate for solvent intoxication diagnostics. In addition to diagnostics, the fast breath solvent analysis proved feasible for controlling the ethanol and methanol concentration during haemodialysis treatment. Because of the simplicity of the sampling and analysis procedure, non-laboratory personnel, such as police officers or social workers, could also operate the analyzer for screening purposes.
Resumo:
The first observations of solar X-rays date back to late 1940 s. In order to observe solar X-rays the instruments have to be lifted above the Earth s atmosphere, since all high energy radiation from the space is almost totally attenuated by it. This is a good thing for all living creatures, but bad for X-ray astronomers. Detectors observing X-ray emission from space must be placed on-board satellites, which makes this particular discipline of astronomy technologically and operationally demanding, as well as very expensive. In this thesis, I have focused on detectors dedicated to observing solar X-rays in the energy range 1-20 keV. The purpose of these detectors was to measure solar X-rays simultaneously with another X-ray spectrometer measuring fluorescence X-ray emission from the Moon surface. The X-ray fluorescence emission is induced by the primary solar X-rays. If the elemental abundances on the Moon were to be determined with fluorescence analysis methods, the shape and intensity of the simultaneous solar X-ray spectrum must be known. The aim of this thesis is to describe the characterization and operation of our X-ray instruments on-board two Moon missions, SMART-1 and Chandrayaan-1. Also the independent solar science performance of these two almost similar X-ray spectrometers is described. These detectors have the following two features in common. Firstly, the primary detection element is made of a single crystal silicon diode. Secondly, the field of view is circular and very large. The data obtained from these detectors are spectra with a 16 second time resolution. Before launching an instrument into space, its performance must be characterized by ground calibrations. The basic operation of these detectors and their ground calibrations are described in detail. Two C-flares are analyzed as examples for introducing the spectral fitting process. The first flare analysis shows the fit of a single spectrum of the C1-flare obtained during the peak phase. The other analysis example shows how to derive the time evolution of fluxes, emission measures (EM) and temperatures through the whole single C4 flare with the time resolution of 16 s. The preparatory data analysis procedures are also introduced in detail. These are required in spectral fittings of the data. A new solar monitor design equipped with a concentrator optics and a moderate size of field of view is also introduced.
Resumo:
We discuss a dynamic pricing model which will aid automobile manufacturer in choosing the right price for customer segment. Though there is oligopoly market structure, the customers get "locked" into a particular technology/company which virtually makes the situation akin to a monopoly. There are associated network externalities and positive feedback. The key idea in monopoly pricing lies in extracting the customer surplus by exploiting the respective elasticities of demand. We present a Walrasian general equilibrium approach to determine the segment price. We compare the prices obtained from optimization model with that from Walrasian dynamics. The results are encouraging and can serve as a critical factor in Customer Relationship Management (CRM) and thereby effectively manage the lock-in.
Resumo:
The present study focuses on the drug market in Helsinki in the early 2000s, mainly on the dealing in and use of amphetamines, cannabis and the pharmaceutical Subutex. The drug market is usually analysed into upper, middle and lower level markets. These levels are very different in terms of their operating practices, although there may be some mingling. The present study is mainly concerned with drug dealers and users in the lower and middle level markets. Operations also differ depending on whether the dealing involves just one drug or several. Dealing in and using Subutex is a very different business from dealing and using home grown cannabis, for instance: both the customers and the dealers are mostly quite different. The study material was mostly collected through ethnographical field work, including observations and interviews. Interviews with officials and minutes of pre-trial investigations concerning aggravated drug crimes are also included. The study discusses the roles of dealers on the various levels of the drug market in Helsinki and traces activities at various levels. Ethnographical methods are employed to observe day-to-day drug dealing and use and leisure pursuits in private homes and in public premises. The study takes note of the risks inherent in drug dealing and estimates what kind of drug dealers can last the longest on the market without the authorities intervening. At the same time, the study discusses how small groups on the middle and lower levels of the drug market avoid control measures undertaken by the authorities and how the authorities address these groups. Moreover, the study discusses what the drug market is like in prison from the perspective of a drug dealer sent to prison, what their everyday lives are like after release, and how much money dealers on various levels of the drug market make. The study demonstrates that drug dealing in Helsinki, whether we consider the very top or the very bottom of the pyramid, is a far from rational pursuit. The undertakings are not very systematic; they are more a reaction to intoxicant addiction( s) and other problems caused by other dealers, the dealers own actions and the actions of the police. The everyday lives of drug dealers are often chaos only alleviated by drug use in the company of buyers or alone. If a drug dealer uses drugs himself/herself, things become even more complicated and a vicious circle develops. At the same time, everyday life is certainly exciting, and a drug dealer often has a highly eventful if brief life. Drug dealing is a very masculine pursuit, and there is a sort of macho code governing it, although this does not nearly always work as it should. This macho code, typically for illegal activities, involves the threat of violence as a control measure. Hence the untranslatable slang expression Kill the cows : the Finnish word for calf has the slang meaning snitch or police informant . No more cows, no more calves. But informing on others to the authorities is a fact of life in the drug-dealing world. Contributing factors to being reported to the authorities are the dealer s own mistakes and the actions of other dealers and the police. A determined drug dealer will not be deterred from drug dealing by a prison sentence. However, following time in prison only few dealers manage to gain an income from drug dealing commensurate with its risks.
Resumo:
Body-centered-tetragonal (BCT) ZnS nanocrystals have been synthesized, for the first time to the best of our knowledge, by using the chemical coprecipitation method at higher synthesis temperatures of 65 and 95 degrees C. It is confirmed from X-ray diffraction (XRD) studies that in the high-temperature-synthesized samples, cubic and BCT phases coexist, in contrast to the room-temperature-synthesized sample, which consists of only cubic phase with sizes of the particles lying between 2 and 3 nm. The sizes of BCT phase nanocrystals are bigger than those of cubic phase of ZnS. The presence of BCT phase of ZnS in the samples is increased from 40 to 90% when the temperature of synthesis is increased from 65 to 95 degrees C. The nanocrystalline nature and UV-Vis absorption characteristics of the prepared samples have been studied with a transmission electron microscope (TEM) and a UV-Visible pectrophotometer, respectively. The room-temperature-synthesized ZnS sample shows photoluminescence (PL) emission in the blue region with multiple peaks, whereas the high-temperature-synthesized samples show PL emissions in the visible region. The Gaussian fittings of the measured PL spectra shows that three PL peaks at 429, 477, and 525 nm are appeared in the 65 degrees C sample and two peaks at 491 and 540 nm appear in the 95 degrees C sample with the enhanced PL intensity of the green peak at 540 nm. (C) 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
Resumo:
Fiber bragg grating (FBG) sensors have been widely used for number of sensing applications like temperature, pressure, acousto-ultrasonic, static and dynamic strain, refractive index change measurements and so on. Present work demonstrates the use of FBG sensors in in-situ measurement of vacuum process with simultaneous leak detection capability. Experiments were conducted in a bell jar vacuum chamber facilitated with conventional Pirani gauge for vacuum measurement. Three different experiments have been conducted to validate the performance of FBG sensor in monitoring vacuum creating process and air bleeding. The preliminary results of FBG sensors in vacuum monitoring have been compared with that of commercial Pirani gauge sensor. This novel technique offers a simple alternative to conventional method for real time monitoring of evacuation process. Proposed FBG based vacuum sensor has potential applications in vacuum systems involving hazardous environment such as chemical and gas plants, automobile industries, aeronautical establishments and leak monitoring in process industries, where the electrical or MEMS based sensors are prone to explosion and corrosion.
Resumo:
This paper proposes a compact electric discharge plasma source for controlling NOX emission in diesel engine exhaust. An automobile ignition coil was used to generate the high voltage pulse using flyback topology. This design is aimed at retrofitting the existing catalytic converters with pulse assisted cleaning technique. In this paper we bring out a relative comparison of discharge plasma and plasma-adsorbent process at different gas flow rates. Activated alumina was used as adsorbent. The main emphasis is laid on the development of a compact pulse source from a DC supply for the removal of NOX from the filtered diesel engine exhaust.
Resumo:
Shri Shakti LPG Ltd. (SSLPG) imports and markets propane (referred to as liquefied petroleum gas (LPG) in India) in south India. It sells LPG in packed (cylinder) form to domestic customers and commercial establishments through a network of dealers. Dealers replenish their stocks of filled cylinders from bottling plants, which in turn receive LPG in bulk from the cheaper of SSLPG's two import-and-storage facilities that are located on the Indian coast. We implemented integer programming to help SSLPG decide on the locations and long-run sizes of its bottling plants. We estimate that our recommended configuration of bottling plants is about $1 million cheaper annually than the one that SSLPG had initially planned.
Resumo:
There is considerable interest currently in developing magnesium based alloys as replacements for aluminum alloys in automobile applications, due to their high specific strength as compared to aluminum alloys. However, the poor formability of magnesium alloys has restricted their applications; superplasticity can be utilized to form components with complex shapes. In the present study, the compressive deformation characteristics of a Mg-0.8 wt% Al alloy with an initial grain size of 19 +/- 1.0 mum have been studied in the temperature range of 623-673 K and at strain rates ranging from 10(-7) to 10(-3) s(-1). The stress exponent was observed to decrease with a decrease in stress. The results are analyzed in terms of the existing theoretical models for high temperature deformation. Furthermore, the potential for superplasticity in this alloy is explored, based on the mechanical and microstructural characteristics of the alloy.
Resumo:
TNCs having their production bases in developing countries provide increasing opportunity for local SMEs to have subcontracting relationships with these TNCs.Even though some theoretical and a few empirical studies throw light on the nature of assistance provided by TNCs to local SMEs through subcontracting relationships,none of the studies so far analysed the diversity of assistance that subcontracting SMEs of India would be able to obtain from a TNC using quantitative measurement.This paper probes the extent of linkages and diversity of assistance that Indian subcontracting SMEs would be able to obtain from a TNC customer based on primary data from SME subcontractors of a major TNC automobile manufacturer. Statistical analysis of direct assistance revealed that SMEs receive more of product and purchase process assistance. The extent of assistance for their process related,marketing, human resource and financial requirements is low whereas the assistance for their organisational know-how requirements is moderate. The major indirect benefits these SMEs could achieve are knowledge transfer, business volume, superior work culture, reputation and quality improvement.
Resumo:
In this paper studies were carried out on two compact electric discharge plasma sources for controlling nitrogen oxides (NOX) emission in diesel engine exhaust. The plasma sources consist of an old television flyback transformer to generate high frequency high voltage ac (HVAC) and an automobile ignition coil to generate the high voltage pulses (HV Pulse). The compact plasma sources are aimed at retrofitting the existing catalytic converters with electric discharge assisted cleaning technique. To enhance NOX removal efficiency cascaded plasma-adsorbent technique has been used. Studies were reported at different flow rates and load conditions of the diesel engine.
Resumo:
This paper proposes a compact electric discharge plasma source for controlling NOX emission in diesel engine exhaust. Boost converter is used to boost to solar powered battery voltage to 24V, further an automobile ignition coil was used to generate the high voltage pulse using fly-back topology. This design is aimed at retrofitting the existing catalytic converters with pulse assisted cleaning technique. In this paper we bring out a relative comparison of discharge plasma and plasma-adsorbent process at different gas flow rates. Activated alumina was used as adsorbent. The main emphasis is laid on the development of a compact pulse source from 12V battery, which is powered by the solar, for the removal of NOX from the filtered diesel engine exhaust.