991 resultados para Air-pilot guides.
Resumo:
Aims: To investigate methods for the recovery of airborne bacteria within pig sheds and to then use the appropriate methods to determine the levels of heterotrophs and Escherichia coli in the air within sheds. Methods and Results: AGI-30 impingers and a six-stage Andersen multi-stage sampler (AMS) were used for the collection of aerosols. Betaine and catalase were added to impinger collection fluid and the agar plates used in the AMS. Suitable media for enumerating E. coli with the Andersen sampler were also evaluated. The addition of betaine and catalase gave no marked increase in the recovery of heterotrophs or E. coli. No marked differences were found in the media used for enumeration of E. coli. The levels of heterotrophs and E. coli in three piggeries, during normal pig activities, were 2Æ2 · 105 and 21 CFU m)3 respectively. Conclusions: The failure of the additives to improve the recovery of either heterotrophs or E. coli suggests that these organisms are not stressed in the piggery environment. The levels of heterotrophs in the air inside the three Queensland piggeries investigated are consistent with those previously reported in other studies. Flushing with ponded effluent had no marked or consistent effect on the heterotroph or E. coli levels. Significance and Impact of the Study: Our work suggests that levels of airborne heterotrophs and E. coli inside pig sheds have no strong link with effluent flushing. It would seem unlikely that any single management activity within a pig shed has a dominant influence on levels of airborne heterotrophs and E. coli
Resumo:
- Objective We sought to assess the effect of long-term exposure to ambient air pollution on the prevalence of self-reported health outcomes in Australian women. - Design Cross-sectional study - Setting and participants The geocoded residential addresses of 26 991 women across 3 age cohorts in the Australian Longitudinal Study on Women's Health between 2006 and 2011 were linked to nitrogen dioxide (NO2) exposure estimates from a land-use regression model. Annual average NO2 concentrations and residential proximity to roads were used as proxies of exposure to ambient air pollution. - Outcome measures Self-reported disease presence for diabetes mellitus, heart disease, hypertension, stroke, asthma, chronic obstructive pulmonary disease and self-reported symptoms of allergies, breathing difficulties, chest pain and palpitations. - Methods Disease prevalence was modelled by population-averaged Poisson regression models estimated by generalised estimating equations. Associations between symptoms and ambient air pollution were modelled by multilevel mixed logistic regression. Spatial clustering was accounted for at the postcode level. - Results No associations were observed between any of the outcome and exposure variables considered at the 1% significance level after adjusting for known risk factors and confounders. - Conclusions Long-term exposure to ambient air pollution was not associated with self-reported disease prevalence in Australian women. The observed results may have been due to exposure and outcome misclassification, lack of power to detect weak associations or an actual absence of associations with self-reported outcomes at the relatively low annual average air pollution exposure levels across Australia.
Resumo:
Background It is often believed that by ensuring the ongoing completion of competency documents and life-long learning in nursing practice guarantees quality patient care. This is probably true in most cases where it provides reassurances that the nursing team is maintaining a safe “generalised” level of practice. However, competency does not always promise quality performance. There are a number of studies that have reported differences in what practitioners know and what they actually do despite being deemed competent. Aim The aim of this study was to assess whether our current competency documentation is fit for purpose and to ascertain whether performance assessment needs to be a key component in determining competence. Method 15 nurses within a General ICU who had been on the unit <4 years agreed to participate in this project. Using participant observation and assessing performance against key indicators of the Benner Novice to Expert5 model the participants were supported and assessed over the course of a ‘normal’ nursing shift. Results The results were surprising both positively and negatively. First, the nurses felt more empowered in their clinical decision making skills; second, it identified individual learning needs and milestones in educational development. There were some key challenges identified which included 5 nurses over estimating their level of competence, practice was still very much focused on task acquisition and skill and surprisingly some nurses still felt dominated by the other health professionals within the unit. Conclusion We found that the capacity and capabilities of our nursing workforce needs continual ongoing support especially if we want to move our staff from capable task-doer to competent performers. Using the key novice to expert indicators identified the way forward for us in how we assess performance and competence in practice particularly where promotion to higher grades is based on existing documentation.
Resumo:
Children with end-stage liver disease now form a major sub-group of patients considered suitable for liver transplantation (ltp), and enjoy better survival statistics after transplantation than do adults. Since June 1984, a paediatric ltp programme has been developed in Brisbane with an initial working relationship and ongoing close links with two USA centres (Pittsburgh, and the UCLA Medical Center). Fourteen children with end-stage liver disease have been referred to the Queensland Liver Transplantation Programme for formal assessment. Following frank, informed discussion with their parents, 10 of these children were offered the option of ltp. During the transition stage, two infants with biliary atresia were referred to UCLA at their parents' request and, subsequently, eight children aged from 9 months to 6 years have been placed on a transplant candidacy list in Brisbane. A donor procurement team with access to a Queensland Government jet has been available to cover all mainland States except Western Australia. Six of the children have now had orthotopic ltp (two children at the UCLA Medical Center; four children at the Royal Children's Hospital, Brisbane). One UCLA patient died with a non-functioning graft, and one Brisbane patient died 5 weeks post-transplant with rejection, hepatic artery thrombosis and sepsis. The other four children are alive and well, three with normal liver function and one with unexplained intrahepatic cholestasis, during the 1-20 month follow-up to date. Three further children have died of their liver disease without a donor of an appropriate blood group and size being found, and one patient still awaits a suitable donor. The experience of these authors suggests that ltp is a major advance in the treatment of paediatric liver disease, and that the procedure can be carried out successfully in Australia with initial results comparable with leading overseas centres. The procedure requires the full array of services of a major paediatric tertiary care facility, an intensive team effort with awareness of the special needs of children, and a widespread procurement capability. A major problem for Australia is the procurement of sufficient numbers of optimal paediatric donor livers.
Resumo:
It has been shown that it is possible to extend the validity of the Townsend breakdown criterion for evaluating the breakdown voltages in the complete pd range in which Paschen curves are available. Evaluation of the breakdown voltages for air (pd=0.0133 to 1400 kPa · cm), N2(pd=0.0313 to 1400 kPa · cm) and SF6 (pd=0.3000 to 1200 kPa · cm) has been done and in most cases the computed values are accurate to ±3% of the measured values. The computations show that it is also possible to estimate the secondary ionization coefficient ¿ in the pd ranges mentioned above.
Resumo:
Background Previous studies (mostly questionnaire-based in children) suggest that outdoor activity is protective against myopia. There are few studies on young adults investigating both the impact of simply being outdoors versus performing physical activity. The aim was to study the relationship between the refractive error of young adults and their physical activity patterns. Methods Twenty-seven university students, aged 18 to 25 years, wore a pedometer (Omron HJ720ITE) for seven days both during the semester and holiday periods. They simultaneously recorded the type of activity performed, its duration, the number of steps taken (from the pedometer) and their location (indoors/outdoors) in a logbook. Mean spherical refractive error was used to divide participants into three groups (emmetropes: +1.00 to -0.50 D, low myopes: -0.62 to -3.00 D, higher myopes: -3.12 D or greater myopia). Results There were no significant differences between the refractive groups during the semester or holiday periods; the average daily times spent outdoors, the duration of physical activity, the ratio of physical activity performed outdoors to indoors and amount of near work performed were similar. The peak exercise intensity was similar across all groups: approximately 100 steps perminute, a brisk walk. Up to one-third of all physical activity was performed outdoors. There were some significant differences in activities performed during semester and holiday times. For example, lowmyopes spent significantly less time outside (49 ± 47 versus 74 ± 41 minutes, p = 0.005) and performed less physical activity (6,388 ± 1,747 versus 6,779 ± 2,746 steps per day; p = 0.03) during the holidays compared to during semester. Conclusions The fact that all groups had similar low exercise intensity butmany were notmyopic suggests that physical activity levels are not critical. There were differences in the activity patterns of lowmyopes during semester and holiday periods. This study highlights the need for a larger longitudinal-based study with particular emphasis on how discretionary time is spent.
Resumo:
Exercise science is now an integral part of the allied health framework in Australia and graduates from accredited programmes are equipped with skills recognised as being important in the prevention and management of lifestyle-related diseases. This pilot study sought to determine the experiences of 11 final-year exercise science students in their major practicum and identify skills learned and developed while on placement. Analysis of the interview data established that the students worked with clients from a broad range of sociocultural and socioeconomic backgrounds, both within and between practicum sites; the students’ experiences and their preparedness to engage with clients from different backgrounds varied as a result. Although the students generally reported being technically skilled for their major placement, many reported being underprepared to deal with people from different backgrounds. However, all participants held that their interpersonal skills greatly improved in response to their placement and several remarked that they developed their problem-solving skills through watching and assisting their supervisors work with clients. The present study confirms the practicum as a critical learning site for improving communication and problem-solving skills with exercise science and exercise physiology students.
Resumo:
Novel self-supported natural and synthetic polymer membranes of chitosan-hydroxy ethyl Cellulose-montmorillonite (CS-HEC-MMT) and polyvinyl alcohol (PVA)-polystyrene sulfonic acid (PSSA) are prepared by solution casting method followed by crosslinking. These membranes are employed for air humidification at varying temperatures between 30 degrees C and 70 degrees C and their performances are compared with commercial Nafion membranes. High hater fluxes with desired humidified-air output have been achieved for CS-HEC-MMT and PVA-PSSA hybrid membranes at air-flow rates of 1-10 slpm. Variation in the air/water mixing ratio, dew point, and relative humidity that ultimately results in desired water flux With respect to air-flow rates are also quantified for all the membranes. Water flux values for CS-HEC-MMT are less than those for Nafion (R) and PVA-PSSA membranes, but the operational Stability of CS-HEC-MMT membrane is higher than PVA-PSSA and comparable with Nafion (R) both of which can operate up to 70 degrees C at repetitive cycles of humidification.
Resumo:
Interfacial area measurement has been carried out experimentally by measuring the bubble size and holdup for air-sodium chloride solution system. The size of the bubble is predominantly established by the air hold up. High speed photography technique for bubble size measurement and gamma ray attenuation method for holdup measurements are followed. The measured values are compared with the theoretically predicted values. Interracial area as a function of the liquid flow rate and also its distance from the nozzle of the ejector has been reported in this paper. The results obtained for this non-reactive system are also compared with those of air-water system.
Resumo:
This report describes the development and simulation of a variable rate controller for a 6-degree of freedom nonlinear model. The variable rate simulation model represents an off the shelf autopilot. Flight experiment involves risks and can be expensive. Therefore a dynamic model to understand the performance characteristics of the UAS in mission simulation before actual flight test or to obtain parameters needed for the flight is important. The control and guidance is implemented in Simulink. The report tests the use of the model for air search and air sampling path planning. A GUI in which a set of mission scenarios, in which two experts (mission expert, i.e. air sampling or air search and an UAV expert) interact, is presented showing the benefits of the method.
Resumo:
In school environments, children are constantly exposed to mixtures of airborne substances, derived from a variety of sources, both in the classroom and in the school surroundings. It is important to evaluate the hazardous properties of these mixtures, in order to conduct risk assessments of their impact on chil¬dren’s health. Within this context, through the application of a Maximum Cumulative Ratio approach, this study aimed to explore whether health risks due to indoor air mixtures are driven by a single substance or are due to cumulative exposure to various substances. This methodology requires knowledge of the concentration of substances in the air mixture, together with a health related weighting factor (i.e. reference concentration or lowest concentration of interest), which is necessary to calculate the Hazard Index. Maximum cumulative ratio and Hazard Index values were then used to categorise the mixtures into four groups, based on their hazard potential and therefore, appropriate risk management strategies. Air samples were collected from classrooms in 25 primary schools in Brisbane, Australia. Analysis was conducted based on the measured concentration of these substances in about 300 air samples. The results showed that in 92% of the schools, indoor air mixtures belonged to the ‘low concern’ group and therefore, they did not require any further assessment. In the remaining schools, toxicity was mainly governed by a single substance, with a very small number of schools having a multiple substance mix which required a combined risk assessment. The proposed approach enables the identification of such schools and thus, aides in the efficient health risk management of pollution emissions and air quality in the school environment.
Resumo:
Exposure assessment studies conducted in developing countries have been based on fixed-site monitoring to date. This is a major deficiency, leading to errors in estimating the actual exposures, which are a function of time spent and pollutant concentrations in different microenvironments. This study quantified school children’s daily personal exposure to ultrafine particles (UFP) using real-time monitoring, as well as volatile organic compounds (VOCs) and NO2 using passive sampling in rural Bhutan in order to determine the factors driving the exposures. An activity diary was used to track children’s time activity patterns, and difference in mean exposure levels across sex and indoor/outdoor were investigated with ANOVA. 82 children, attending three primary schools participated in this study; S1 and S2 during the wet season and S3 during the dry season. Mean daily UFP exposure (cm-3) was 1.08 × 104 for children attending S1, 9.81 × 103 for S2, and 4.19 × 104 for S3. The mean daily NO2 exposure (µg m-3) was 4.27 for S1, 3.33 for S2 and 5.38 for S3 children. Likewise, children attending S3 also experienced higher daily exposure to a majority of the VOCs than those attending S1 and S2. Time-series of UFP personal exposures provided detailed information on identifying sources of these particles and quantifying their contributions to the total daily exposures for each microenvironment. The highest UFP exposure resulted from cooking/eating, contributing to 64% of the daily exposure, due to firewood combustion in houses using traditional mud cookstoves. The lowest UFP exposures were during the hours that children spent outdoors at school. The outcomes of this study highlight the significant contributions of lifestyle and socio-economic factors in personal exposures and have applications in environmental risk assessment and household air pollution mitigation in Bhutan.
Resumo:
Human exposures in transportation microenvironments are poorly represented by ambient stationary monitoring. A number of on-road studies using vehicle-based mobile monitoring have been conducted to address this. Most previous studies were conducted on urban roads in developed countries where the primary emission source was vehicles. Few studies have examined on-road pollution in developing countries in urban settings. Currently, no study has been conducted for roadways in rural environments where a substantial proportion of the population live. This study aimed to characterize on-road air quality on the East-West Highway (EWH) in Bhutan and identify its principal sources. We conducted six mobile measurements of PM10, particle number (PN) count and CO along the entire 570 km length of the EWH. We divided the EWH into five segments, R1-R5, taking the road length between two district towns as a single road segment. The pollutant concentrations varied widely along the different road segments, with the highest concentrations for R5 compared with other road segments (PM10 = 149 µg/m3, PN = 5.74 × 104 particles/cm-3, CO = 0.19 ppm), which is the final segment of the road to the capital. Apart from vehicle emissions, the dominant sources were road works, unpaved roads and roadside combustion activities. Overall, the highest contributions above the background levels were made by unpaved roads for PM10 (6 times background), and vehicle emissions for PN and CO (5 and 15 times background, respectively). Notwithstanding the differences in instrumentation used and particle size range measured, the current study showed lower PN concentrations compared with similar on-road studies. However, concentrations were still high enough that commuters, road maintenance workers and residents living along the EWH, were potentially exposed to elevated pollutant concentrations from combustion and non-combustion sources. Future studies should focus on assessing the dispersion patterns of roadway pollutants and defining the short- and long-term health impacts of exposure in Bhutan, as well as in other developing countries with similar characteristics.
Resumo:
Limited studies have examined the associations between air pollutants [particles with diameters of 10um or less (PM10), sulfur dioxide (SO2), and nitrogen dioxide (NO2)] and fasting blood glucose (FBG). We collected data for 27,685 participants who were followed during 2006 and 2008. Generalized Estimating Equation models were used to examine the effects of air pollutants on FBG while controlling for potential confounders. We found that increased exposure to NO2, SO2 and PM10 was significantly associated with increased FBG levels in single pollutant models (p<0.001). For exposure to 4 days’ average of concentrations, a 100 µg/m3 increase in SO2, NO2, and PM10 was associated with 0.17 mmol/L (95%CI: 0.15–0.19), 0.53 mmol/L (95%CI: 0.42–0.65), and 0.11 mmol/L (95%CI: 0.07–0.15) increase in FBG, respectively. In the multi-pollutant models, the effects of SO2 were enhanced, while the effects of NO2 and PM10 were alleviated. The effects of air pollutants on FBG were stronger in female, elderly, and overweight people than in male, young and underweight people. In conclusion, the findings suggest that air pollution increases the levels of FBG. Vulnerable people should pay more attention on highly polluted days to prevent air pollution-related health issues.
Resumo:
Characterization of indoor air quality in school classrooms is crucial to children’s health and performance. The present study was undertaken to characterize the indoor air quality in six naturally ventilated classrooms of three schools in Cassino (Italy). Indoor particle number, mass, black carbon, CO2 and radon concentrations, as well as outdoor particle number were measured within school hours during the winter and spring season. The study found the concentrations of indoor particle number were influenced by the concentrations in the outdoors; highest BC values were detected in classrooms during peak traffic time. The effect of different seasons’ airing mode on the indoor air quality was also detected. The ratio between indoor and outdoor particles was of 0.85 ± 0.10 in winter, under airing conditions of short opening window periods, and 1.00 ± 0.15 in spring when the windows were opened for longer periods. This was associated to a higher degree of penetration of outdoor particles due to longer period of window opening. Lower CO2 levels were found in classrooms in spring (908 ppm) than in winter (2206 ppm). Additionally, a greater reduction in radon concentrations was found in spring. In addition, high PM10 levels were found in classrooms during break time due to re-suspension of coarse particles. Keywords: classroom; Ni/Nout ratio; airing by opening windows; particle number