880 resultados para pebble bed reactor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this thesis is to find and analyze different methods which reduce fluid bed boilers’ auxiliary power consumption. The objective is to examine the effects and feasibility of these methods. The literature part explains how fluid bed boilers work and what are the main sources of auxiliary power consumption. Designs and operation of these equipment are presented. The literature part also discusses the basics of auxiliary power consumption reduction and introduces four low pressure drop constructions. The experimental part inspects six different methods. Effects of these methods on the auxiliary power consumption are calculated and their impacts on the operation of the boiler are modeled. Calculations show that reasonable changes can reduce fluid bed boiler’s auxiliary power consumption by 2,1-10,2 %. Biggest reductions come from lower air coefficients, smaller bed a-level pressures and lower primary/secondary air –ratios. Models showed no problems with the smaller bed a-level pressures. With the lower air coefficients and smaller primary/secondary air –ratios the models showed a significant increase in the carbon monoxide levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increasing amount of renewable energy source based electricity production has set high load control requirements for power grid balance markets. The essential grid balance between electricity consumption and generation is currently hard to achieve economically with new-generation solutions. Therefore conventional combustion power generation will be examined in this thesis as a solution to the foregoing issue. Circulating fluidized bed (CFB) technology is known to have sufficient scale to acts as a large grid balancing unit. Although the load change rate of the CFB unit is known to be moderately high, supplementary repowering solution will be evaluated in this thesis for load change maximization. The repowering heat duty is delivered to the CFB feed water preheating section by smaller gas turbine (GT) unit. Consequently, steam extraction preheating may be decreased and large amount of the gas turbine exhaust heat may be utilized in the CFB process to reach maximum plant electrical efficiency. Earlier study of the repowering has focused on the efficiency improvements and retrofitting to maximize plant electrical output. This study however presents the CFB load change improvement possibilities achieved with supplementary GT heat. The repowering study is prefaced with literature and theory review for both of the processes to maximize accuracy of the research. Both dynamic and steady-state simulations accomplished with APROS simulation tool will be used to evaluate repowering effects to the CFB unit operation. Eventually, a conceptual level analysis is completed to compare repowered plant performance to the state-of-the-art CFB performance. Based on the performed simulations, considerably good improvements to the CFB process parameters are achieved with repowering. Consequently, the results show possibilities to higher ramp rate values achieved with repowered CFB technology. This enables better plant suitability to the grid balance markets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this master’s thesis were to understand the importance of bubbling fluidized bed (BFB) conditions and to find out how digital image processing and acoustic emission technology can help in monitoring the bed quality. An acoustic emission (AE) measurement system and a bottom ash camera system were evaluated in acquiring information about the bed conditions. The theory part of the study describes the fundamentals of BFB boiler and evaluates the characteristics of bubbling bed. Causes and effects of bed material coarsening are explained. The ways and methods to monitor the behaviour of BFB are determined. The study introduces the operating principles of AE technology and digital image processing. The empirical part of the study describes an experimental arrangement and results of a case study at an industrial BFB boiler. Sand consumption of the boiler was reduced by optimization of bottom ash handling and sand feeding. Furthermore, data from the AE measurement system and the bottom ash camera system was collected. The feasibility of these two systems was evaluated. The particle size of bottom ash and the changes in particle size distribution were monitored during the test period. Neither of the systems evaluated was ready to serve in bed quality control accurately or fast enough. Particle size distributions according to the bottom ash camera did not correspond to the results of manual sieving. Comprehensive interpretation of the collected AE data requires much experience. Both technologies do have potential and with more research and development they may enable acquiring reliable and real-time information about the bed conditions. This information could help to maintain disturbance-free combustion process and to optimize bottom ash handling system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energy generation industry is very capital-intensive industry. Productivity and availability requirements have increased while competition and quality requirement have increased. Maintenance has a significant role that these requirements can be reached. Even maintenance is much more than repairing faults nowadays, spare parts are important part of maintenance. Large power boilers are user-specific therefore features of boilers vary from project to project. Equipment have been designed to follow the customer’s requirements therefore spare parts are mainly user-specific also. The study starts with literature review introducing maintenance, failure mechanisms, and systems and equipment of bubbling fluidized bed boiler. At the final part spare part management is discussed from boiler technology point of view. For this part of the study science publications about spare part management are utilized also some specialist from a boiler technology company and other original equipment manufacturers were interviewed. Spare part management is challenging from the boiler supplier point of view and the end user of spare parts has a responsibility of stocking items. Criticality analysis can be used for finding most critical devices of the process and spare part management shall focus to those items. Spare parts are part of risk management. Stocking spare parts is increasing costs but then high spare part availability is decreasing delay time caused by fault of item.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study has been conducted focusing on how the phosphorus renrx)val efficiency of a constructed wetland (CW) can be optimized through the selective enrichment of the substratum. Activated alumina and powdered iron were examined as possible enrichment compounds. Using packed glass column trials it was found that alumina was not suitable for the renx)val of ortho-phosphate from solution, while mixtures of powdered iron and quartz sand proved to be very efficient. The evaluation of iron/sand mixtures in CWs planted with cattails was performed in three stages; first using an indoor lab scale wetland, then an outdoor lab scale wetland, and finally in a small scale pilot project. For the lab scale tests, three basic configurations were evaluated: using the iron/sand as a pre-filter, in the root bed. and as a post filter. Primary lagoon effluent was applied to the test cells to simulate actual CW conditions, and the total phosphorus and iron concentrations of the influent and effluent were nfK)nitored. The pilot scale trials were limited to using only a post filter design, due to in-progress research at the pilot site. The lab scale tests achieved average renrK>val efficiencies greater than 91% for all indoor configurations, and greater than 97% for all outdoor configurations. The pilot scale tests had an average renK)val efficiency of 60%. This relatively low efficiency in the pilot scale can be attributed to the post filters being only one tenth the size of the lab scale test in terms of hydraulic loading (6 cm/day vs. 60 cm/day).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine the potential of biochemical parameters, such as enzyme activity and adenosine triphosphate (ATP) levels, as monitors of process performance in the Upflow Anaerobic Sludge Blanket (UASB) reactor utilizing a starch wastewater. The acid and alkaline phosphatase activity and the ATP content of the UASB sludge were measured in response to changes in flow rate and nutrient loading. Conventional parameters of process performance, such as gas production, acetic acid production, COD, phosphorus, nitrogen and suspended solids loadings and % COD removal were also monitored. The response of both biochemical and conventional parameters to changing process conditions was then compared. Alkaline phosphatase activity exhibited the highest activity over the entire study perioda A high suspended solids loading was observed to upset the system in terms of gas production, acetic acid production and % COD removala The initial rate of increase in alkaline phosphatase activity following an increase in loading was four times as great during process upset than under conditions of good performance. The change in enzyme actiVity was also more sensitive to process upset than changes in acetic acid production. The change in ATP content of the sludge with time suggested that enzyme actiVity was changing independently of the actual viable biomass present. The bacterial composition of the anaerobic sludge granules was similar to that of other sludge bed systems, at the light and scanning electron microscope level. Isolated serum bottle cultures produced several acids involved in anaerobic carbohydrate metabolism. The overall performance of the UASB system indicated that higher loadings of soluble nutrients could have been tolerated by the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect that plants {Typha latifolia) as well as root-bed medium physical and chemical characteristics have on the treatment of primary treated domestic wastewater within a vertical flow constructed wetland system was investigated. Five sets of cells, with two cells in each set, were used. Each cell was made of concrete and measured 1 .0 m X 1 .0 m and was 1.3 m deep. Four different root-bed media were tested : Queenston Shale, Fonthill Sand, Niagara Shale and a Michigan Sand. Four of the sets contained plants and a single type of root-bed medium. The influence of plants was tested by operating a Queenston Shale set without plants. Due to budget constraints no replicates were constructed. All of the sets were operated independently and identically for twenty-eight months. Twelve months of data are presented here, collected after 16 months of continuous operation. Root-bed medium type did not influence BOD5 removal. All of the sets consistently met Ontario Ministry of Environment (MOE) requirements (<25 mg/L) for BOD5 throughout the year. The 12 month average BOD5 concentration from all sets with plants was below 2.36 mg/L. All of the sets were within MOE discharge requirements (< 25 mg/L) for suspended solids with set effluent concentrations ranging from 1.53 to 14.80 mg/L. The Queenston Shale and Fonthill Sand media removed the most suspended solids while the Niagara Shale set produced suspended solids. The set containing Fonthill Sand was the only series to meet MOE discharge requirements (< Img/L) for total phosphorus year-round with a twelve month mean effluent concentration of 0.23 mg/L. Year-round all of the root-bed media were well below MOE discharge requirements (< 20mg/L in winter and < 10 mg/L in sumnner) for ammonium. The Queenston Shale and Fonthill Sand sets removed the most total nitrogen. Plants had no effect on total nitrogen removal, but did influence how nitrogen was cycled within the system. Plants increased the removal of suspended solids by 14%, BOD5 by 10% and total phosphorus by 22%. Plants also increased the amount of dissolved oxygen that entered the system. During the plant growing season removal of total phosphorus was better in all sets with plants regardless of media type. The sets containing Queenston Shale and Fonthill Sand media achieved the best results and plants in the Queenston Shale set increased treatment efficiency for every parameter except nitrogen. Vertical flow wetland sewage treatment systems can be designed and built to consistently meet MOE discharge requirements year-round for BOD5, suspended solids, total phosphorus and ammonium. This system Is generally superior to the free water systems and sub-surface horizontal flow systems in cold climate situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This investigation aims to gain a better understanding of the glacial history of the Pine Point Mining district, Northwest Territories, by examining the sedimentological properties of the glacial sediments including, geochemical analysis, heavy mineral concentrate analysis, clast macro-­‐fabrics, pebble lithologies, and micromorphological investigation. Four till units were identified, and three were associated with identified erosional bedrock features and streamlined landforms in the area, indicating a minimum of three ice flow directions. Sedimentological properties suggest that these units were all Type-­B tectomict/mélange till, emplaced as part of a soft subglacial deformable bed. The lack of ice-­‐marginal advance and retreat sequences within the studied till, suggests the Middle Wisconsinan Laurentide Ice margin was likely north and west of the Pine Point area, as opposed to along the margin of the Canadian Shield and Western Sedimentary Basin where it has been suggested to have existed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias con Especialidad en Ingeniería Ambiental) U.A.N.L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias con Orientación en Procesos Sustentables) UANL, 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Doctor en Ciencias con Especialidad en Biotecnología) UANL, 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Doctor en Ciencias con Orientación en Procesos Sustentables) UANL, 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Problématique : La littérature scientifique ne contient actuellement aucune étude épidémiologique portant sur la relation entre l’exposition à une infestation de punaises de lit (Cimex lectularis) et la santé mentale. L’objectif de cette étude est d’explorer la relation entre le statut d’exposition aux punaises de lit et des mesures de dépression, anxiété et perturbation du sommeil. Méthodes : Cette recherche est une étude transversale basée sur une analyse secondaire des données provenant de N=91 adultes locataires de logements insalubres qui ont répondu à un questionnaire de santé au moment d’interventions médico-environnementales menées par la direction de santé publique de Montréal entre janvier et juin 2010. Le questionnaire de santé inclut le « Questionnaire de santé du patient (QSP-9) », qui est un outil mesurant les symptômes associés à la dépression, l’outil de dépistage d’anxiété généralisée (GAD-7) et les items 1-18 de l’indice de la qualité du sommeil de Pittsburgh (PSQI). L’association entre une exposition autorapportée à une infestation de punaises de lit et le niveau de perturbation du sommeil selon la sous-échelle correspondante du PSQI, les symptômes dépressifs selon le QSP-9 et les symptômes anxieux selon le GAD-7, a été évaluée en utilisant une analyse de régression linéaire multivariée. Des données descriptives relatives aux troubles de sommeil autodéclarés et à des comportements reliés à un isolement social, dus à une exposition aux punaises de lit, sont aussi présentées. Résultats : L’échantillon comprenait 38 hommes et 53 femmes. Parmi les 91 participants, 49 adultes ont signalé une exposition aux punaises de lit et de ce nombre, 53,06% (26/49) ont déclaré des troubles de sommeil et 46,94% (23/49) des comportements d’isolement social, en raison de l’exposition. Les adultes exposés à des punaises de lit ont obtenu des résultats significativement plus élevés sur le QSP-9 (p=0,025), le GAD-7 (p=0,026) et sur la sous-échelle mesurant la perturbation du sommeil (p=0,003) comparativement à ceux qui n’étaient pas exposés. Conclusions : Cette première étude exploratoire met en évidence une association significative entre l’état d’exposition aux punaises de lit et des troubles de sommeil, ainsi que des symptômes anxieux et dépressifs, indiquant que ceux qui sont exposés aux punaises de lit représentent un groupe possiblement à risque de développer des problèmes de santé mentale. Ces résultats viennent en appui aux initiatives des décideurs pour organiser des efforts coordonnés d’éradication au niveau des villes et des provinces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La digestion enzymatique des protéines est une méthode de base pour les études protéomiques ainsi que pour le séquençage en mode « bottom-up ». Les enzymes sont ajoutées soit en solution (phase homogène), soit directement sur le gel polyacrylamide selon la méthode déjà utilisée pour l’isolation de la protéine. Les enzymes protéolytiques immobilisées, c’est-à-dire insolubles, offrent plusieurs avantages tels que la réutilisation de l’enzyme, un rapport élevé d’enzyme-sur-substrat, et une intégration facile avec les systèmes fluidiques. Dans cette étude, la chymotrypsine (CT) a été immobilisée par réticulation avec le glutaraldehyde (GA), ce qui crée des particules insolubles. L’efficacité d’immobilisation, déterminée par spectrophotométrie d’absorbance, était de 96% de la masse totale de la CT ajouté. Plusieurs différentes conditions d’immobilisation (i.e., réticulation) tels que la composition/pH du tampon et la masse de CT durant la réticulation ainsi que les différentes conditions d’entreposage tels que la température, durée et humidité pour les particules GA-CT ont été évaluées par comparaison des cartes peptidiques en électrophorèse capillaire (CE) des protéines standards digérées par les particules. Les particules de GA-CT ont été utilisés pour digérer la BSA comme exemple d’une protéine repliée large qui requit une dénaturation préalable à la digestion, et pour digérer la caséine marquée avec de l’isothiocyanate de fluorescéine (FITC) comme exemple d’un substrat dérivé afin de vérifier l’activité enzymatique du GA-CT dans la présence des groupements fluorescents liés au substrat. La cartographie peptidique des digestions par les particules GA-CT a été réalisée par CE avec la détection par absorbance ultraviolet (UV) ou fluorescence induite par laser. La caséine-FITC a été, en effet, digérée par GA-CT au même degré que par la CT libre (i.e., soluble). Un microréacteur enzymatique (IMER) a été fabriqué par immobilisation de la CT dans un capillaire de silice fondu du diamètre interne de 250 µm prétraité avec du 3-aminopropyltriéthoxysilane afin de fonctionnaliser la paroi interne avec les groupements amines. Le GA a été réagit avec les groupements amine puis la CT a été immobilisée par réticulation avec le GA. Les IMERs à base de GA-CT étaient préparé à l’aide d’un système CE automatisé puis utilisé pour digérer la BSA, la myoglobine, un peptide ayant 9 résidus et un dipeptide comme exemples des substrats ayant taille large, moyenne et petite, respectivement. La comparaison des cartes peptidiques des digestats obtenues par CE-UV ou CE-spectrométrie de masse nous permettent d’étudier les conditions d’immobilisation en fonction de la composition et le pH du tampon et le temps de réaction de la réticulation. Une étude par microscopie de fluorescence, un outil utilisé pour examiner l’étendue et les endroits d’immobilisation GA-CT dans l’IMER, ont montré que l’immobilisation a eu lieu majoritairement sur la paroi et que la réticulation ne s’est étendue pas si loin au centre du capillaire qu’anticipée.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study aims to the hydrodynamic characteristics of swirling fluidized bed, using large particles (Geldart D-type) selected from locally available agricultural produce (coffee beans and black pepper). The important variables considered in the present study include percentage area of opening, angle of air injection and the percentage useful area of the distributor. A total of seven distributors have been designed and fabricated for a bed column of 300 mm, namely single row vane type distributors (15˚ and 20˚ vane angle), inclined hole type distributors (15˚ and 20˚ vane angle) and perforated plate distributors. The useful area of distributor of single row vane type, three now vane-type and inclined hole-type distributors are respectively 64%,91% and 94%. The hydrodynamic parameters considered in the present study include distributor pressure drop, air velocity, minimum fluidizing velocity, bed pressure drop, bed height and the bed behaviour. It has been observed that, in general, the distributor pressure drop decreases with an increase in the percentage area of opening, Further, and increase in the area of opening above 17% will not considerably reduce the distributor pressure drop. In the present study, for the distributor with an area of opening 17%, and corresponding to the maximum measured superficial velocity of 4.33 m/s, the distributor pressure drop obtained was 55.25mm of water. The study on the bed behavior revealed that, in a swirling fluidized bed, once swirl motion starts, the bed pressure drop increases with superficial velocity in the outer region and it decreases in the inner region. This means that, with higher superficial velocity, the air might get by-passed through the inner boundary of the bed (around the cone). So, depending on the process for which the bed is used, the maximum superficial velocity is to be limited to have an optimum bed performance.