953 resultados para label switching


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intensification of North Pacific Intermediate Water during the Younger Dryas and stadials of the last glacial episode has been advocated by Kennett and his colleagues based on studies of ventilation history in Santa Barbara Basin. Because Santa Barbara Basin is a semi-isolated marginal basin, this hypothesis requires testing in sequences on the upper continental margin facing the open-ocean of the Pacific. Ocean Drilling Program Site 1017 is located on the upper slope of southern California off Point Conception close to the entrance of Santa Barbara Basin, an ideal location to test the hypothesis of late Quaternary switching in intermediate waters. We examined chemical and mineral composition, sedimentary structures, and grain size of hemipelagic sediments representing the last 80 k.y. at this site to detect changes in behavior of intermediate waters. We describe distinct compositional and textual variations that appear to reflect changes in grain size in response to flow velocity fluctuations of bottom waters. Qualitative estimates of changes in degree of pyritization indicate better ventilation of bottom water during intervals of stronger bottom-water flow. Comparison between variations in the sediment parameters and the planktonic d18O record indicates intensified bottom-current activity during the Younger Dryas and stadials of marine isotope Stage 3. This result strongly supports the hypothesis of Kennett and his colleagues. Our investigation also suggests strong grain-size control on organic carbon content (and to less extent carbonate carbon content). This, in turn, suggests the possibility that organic carbon content of sediments, which is commonly used as an indicator of surface productivity, can be influenced by bottom currents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examined diatom assemblages in a series of remarkable laminated diatomaceous ooze (LDO) horizons in the marine sediments from Integrated Ocean Drilling Program (IODP) Site U1304 to reconstruct the middle-to-late Pleistocene paleoceanographic evolution of the northern North Atlantic Ocean. Four confirmed diatom biohorizons combined with calcareous nannofossil and paleomagnetic stratigraphies established the chronological framework for the material. The planktonic, araphid, needle-like species Thalassiothrix longissima was the greatest contributor to the LDO facies. From the results of a principal component analysis using the percent abundances of 65 significant (p = 5%) diatom taxa, except for Tx. longissima, which was extremely dominant in almost all horizons observed, we identified two principal component (PC) axes. Taxa probably associated with the stratigraphic distribution of the major zonal marker Neodenticula seminae (ranging from 1.26 to 0.84 Ma in this ocean) loaded on PC1 with a high value. PC2 was related to the ocean surface temperature. The stratigraphic variability of the PC2 score indicated that switching between warm- and cold-water assemblages occurred concurrently with LDO deposition (or extreme Tx. longissima dominance) episodes in several horizons (particularly after 0.84 Ma), suggesting that the Subarctic Convergence (SAC) oceanic front passed over Site U1304 during Pleistocene glacial/interglacial cycles. Our floral evidence supports the model of nearly monospecific LDO formation caused by the enhanced physical accumulation of particular diatoms such as Tx. longissima. On the other hand, Nd. seminae, which probably contributes to spring phytoplankton blooms in the modern ocean, was present only between 1.26 and 0.84 Ma in this area. Thus, we infer that the main contributor of export flux in the regional annual primary production cycle would have shifted drastically from one of a spring phytoplankton bloom leader (Nd. seminae) to minor but mass dump assemblages (Tx. longissima etc.) in the mid-Pleistocene.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have recently demonstrated a biosensor based on a lattice of SU8 pillars on a 1 μm SiO2/Si wafer by measuring vertically reflectivity as a function of wavelength. The biodetection has been proven with the combination of Bovine Serum Albumin (BSA) protein and its antibody (antiBSA). A BSA layer is attached to the pillars; the biorecognition of antiBSA involves a shift in the reflectivity curve, related with the concentration of antiBSA. A detection limit in the order of 2 ng/ml is achieved for a rhombic lattice of pillars with a lattice parameter (a) of 800 nm, a height (h) of 420 nm and a diameter(d) of 200 nm. These results correlate with calculations using 3D-finite difference time domain method. A 2D simplified model is proposed, consisting of a multilayer model where the pillars are turned into a 420 nm layer with an effective refractive index obtained by using Beam Propagation Method (BPM) algorithm. Results provided by this model are in good correlation with experimental data, reaching a reduction in time from one day to 15 minutes, giving a fast but accurate tool to optimize the design and maximizing sensitivity, and allows analyzing the influence of different variables (diameter, height and lattice parameter). Sensitivity is obtained for a variety of configurations, reaching a limit of detection under 1 ng/ml. Optimum design is not only chosen because of its sensitivity but also its feasibility, both from fabrication (limited by aspect ratio and proximity of the pillars) and fluidic point of view. (© 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a theoretical analysis and an optimization method for envelope amplifier. Highly efficient envelope amplifiers based on a switching converter in parallel or series with a linear regulator have been analyzed and optimized. The results of the optimization process have been shown and these two architectures are compared regarding their complexity and efficiency. The optimization method that is proposed is based on the previous knowledge about the transmitted signal type (OFDM, WCDMA...) and it can be applied to any signal type as long as the envelope probability distribution is known. Finally, it is shown that the analyzed architectures have an inherent efficiency limit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modern transmitters usually have to amplify and transmit signals with simultaneous envelope and phase modulation. Due to this property of the transmitted signal, linear power amplifiers (class A, B, or AB) are usually used as a solution for the power amplifier stage. These amplifiers have high linearity, but suffer from low efficiency when the transmitted signal has high peak-to-average power ratio. The Kahn envelope elimination and restoration technique is used to enhance the efficiency of RF transmitters, by combining highly efficient, nonlinear RF amplifier (class E) with a highly efficient envelope amplifier in order to obtain a linear and highly efficient RF amplifier. This paper presents a solution for the envelope amplifier based on a multilevel converter in series with a linear regulator. The multilevel converter is implemented by employing voltage dividers based on switching capacitors. The implemented envelope amplifier can reproduce any signal with a maximum spectral component of 2 MHz and give instantaneous maximum power of 50 W. The efficiency measurements show that when the signals with low average value are transmitted, the implemented prototypes have up to 20% higher efficiency than linear regulators used as a conventional solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In previous works we demonstrated the benefits of using micro–nano patterning materials to be used as bio-photonic sensing cells (BICELLs), referred as micro–nano photonic structures having immobilized bioreceptors on its surface with the capability of recognizing the molecular binding by optical transduction. Gestrinone/anti-gestrinone and BSA/anti-BSA pairs were proven under different optical configurations to experimentally validate the biosensing capability of these bio-sensitive photonic architectures. Moreover, Three-Dimensional Finite Difference Time Domain (FDTD) models were employed for simulating the optical response of these structures. For this article, we have developed an effective analytical simulation methodology capable of simulating complex biophotonic sensing architectures. This simulation method has been tested and compared with previous experimental results and FDTD models. Moreover, this effective simulation methodology can be used for efficiently design and optimize any structure as BICELL. In particular for this article, six different BICELL's types have been optimized. To carry out this optimization we have considered three figures of merit: optical sensitivity, Q-factor and signal amplitude. The final objective of this paper is not only validating a suitable and efficient optical simulation methodology but also demonstrating the capability of this method for analyzing the performance of a given number of BICELLs for label-free biosensing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Switching of a signal beam by another control beam at different wavelength is demonstrated experimentally using the optical bistability occurring in a 1.55 mm-distributed feedback semiconductor optical amplifier (DFBSOA) working in reflection. Counterclockwise (S-shaped) and reverse (clockwise) bistability are observed in the output of the control and the signal beam respectively, as the power of the input control signal is increased. With this technique an optical signal can be set in either of the optical input wavelengths by appropriate choice of the powers of the input signals. The switching properties of the DFBSOA are studied experimentally as the applied bias current is increased from below to above threshold and for different levels of optical power in the signal beam and different wavelength detunings between both input signals. Higher on-off extinction ratios, wider bistable loops and lower input power requirements for switching are obtained when the DFBSOA is operated slightly above its threshold value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports a new family of multimode fiber-optic switching devices based on nematic liquid crystal devices reported by us previously. These devices have a wedged structure as the main characteristic. Several modes of behavior cart arise depending on the internal configuration of the molecules. As we show, fhey have the possibility of total switching of unpolarized light with a very simple structure, low insertion losses, and very low operating voltages These new devices should find a wide range of applications in fiber-optic communication systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Possible switching architectures, with Optically Programmable Logic Cells - OPLCs - will be reported in this paper. These basic units, previously employed by us for some other applications mainly in optical computing, will be employed as main elements to switch optical communications signals. The main aspect to be considered is that because the nternal components of these cells have nonlinear behaviors, namely either pure bistable or SEED-like properties, several are the possibilities to be obtained. Moreover, because their properties are dependent, under certain condition, of the signal wavelength, they are apt to be employed in WDM systems and the final result will depend on the orresponding optical signal frequency. We will give special emphasis to the case where self-routing is achieved, namely to structures of the Batcher or Banyan type. In these cases, as it will be shown, there is the possibility to route any packet input to a certain direction according to its first bits. The number of possible outputs gives the number of bits needed to route signals. An advantage of this configuration is that a very versatile behavior may be allowed. The main one is the possibility to obtain configurations with different kinds of behavior, namely, Strictly Nonblocking, Wide-Sense Nonblocking or Rearrangeably Nonblocking as well as to eliminate switching conflicts at a certain intermediate stages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Large scale high yield cadmium sulfide (CdS) nanowires with uniform diameter were synthesized using a rapid and simple solvo-chemical and hydrothermal route assisted by the surfactant cetyltrimethylammonium bromide (CTAB). Unique CdS nanowires of different morphologies could be selectively produced by only varying the concentration of CTAB in the reaction system with cadmium acetate, sulfur powder and ethylenediamine. We obtained CdS nanowires with diameters of 64–65 nm and lengths of up to several micrometers. A comparative study of the optical properties of ferroelectric liquid crystal (FLC) Felix-017/100 doped with 1% of CdS nanowires was performed. Response times of the order of from 160 to 180 μs, rotational viscosities of the order of from 5000 to 3000 mN s m−2 and polarizations of the order of from 10 to 70 nC cm−2 were measured. We also observed an anti-ferroelectric to ferroelectric transition for CdS doped FLC instead of the ferroelectric to paraelectric transition for pure FLC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyze the gain-switching dynamics of two-section tapered lasers by means of a simplified three-rate-equation model. The goal is to improve the understanding of the underlying physics and to optimize the device geometry to achieve high power short duration optical pulses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Label free immunoassay sector is a ferment of activity, experiencing rapid growth as new technologies come forward and achieve acceptance. The landscape is changing in a “bottom up” approach, as individual companies promote individual technologies and find a market for them. Therefore, each of the companies operating in the label-free immunoassay sector offers a technology that is in some way unique and proprietary. However, no many technologies based on Label-free technology are currently in the market for PoC and High Throughput Screening (HTS), where mature labeled technologies have taken the market.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The field of optical label free biosensors has become a topic of interest during past years, with devices based on the detection of angular or wavelength shift of optical modes [1]. Common parameters to characterize their performance are the Limit of Detection (LOD, defined as the minimum change of refractive index upon the sensing surface that the device is able to detect, and also BioLOD, which represents the minimum amount of target analyte accurately resolved by the system; with units of concentration (common un its are p pm, ng/ml, or nM). LOD gives a first value to compare different biosensors, and is obtained both theoretically (using photonic calculation tools), and experimentally,covering the sensing area with fluids of different refractive indexes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Los sectores de detección biológica demandan continuamente técnicas de análisis y diagnóstico más eficientes y precisas para identificar enfermedades y desarrollar nuevos medicamentos. Actualmente se considera que hay una gran necesidad de desarrollar herramientas de diagnóstico capaces de asegurar sensibilidad, rapidez, sencillez y asequibilidad para aplicaciones en sectores como la salud, la alimentación, el medioambiente o la seguridad. En el ámbito clínico se necesitan profundos avances tecnológicos capaces de ofrecer análisis rápidos, exactos, fiables y asequibles en coste y que tengan como consecuencia la mejora clínica y económica a partir de un diagnóstico eficiente. En concreto, hay un interés creciente por la descentralización del diagnóstico clínico mediante plataformas de detección cercanas al usuario final, denominadas POCs (Point Of Care devices). La utilización de POCs (referidas al diagnóstico cercano al usuario final o fuera del laboratorio de análisis clínico), mediante detección in vitro (IVD), será extremadamente útil en centros de salud, clínicas o unidades hospitalarias, entornos laborales o incluso en el hogar. Por otra parte, el desarrollo de la genómica, proteómica y otras tecnologías conocidas como “omics” (sufijo en inglés para referirse, por ejemplo, a genomics, transcriptomics, proteomics, metabolomics, lipidomics) está incrementando la demanda de nuevas tecnologías mucho más avanzadas con una clara orientación hacia la medicina personalizada y la necesidad de hacer frente a cambios en los tratamientos en el caso de enfermedades complejas. Desde hace poco tiempo se han definido las Celdas Biofónicas (BICELLs) como una metodología novedosa para la detección de agentes biológicos que ofrecen una serie de características que las hacen interesantes como son: Capacidad de multiplexación, alta sensibilidad, posibilidad de medir en gota, compatible con otras tecnologías. En este trabajo se hace un estudio y optimización sobre diferentes tipos de BICELLs y se valoran una serie de figuras de merito a tener en cuenta desde el punto de vista del lector óptico a emplear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of Biophotonic Sensing Cells (BICELLs) based on micro-nano pattemed photonic architectures has been recently proven as an efficient methodology for label-free biosensing by using Optical Interrogation [1]. According to this, we have studied the different optical response for a specific typology of BICELL, consisting of structures of SU -8. This material is biocompatible with different types of biomolecules and can be immobilized on its sensing surface. In particular, we have measured the optical response for a biomarker in clinic diagnostic of dry eye. Although different proteins can be enstudied such as: PRDX5, ANXA 1, ANXA 11, CST 4, PLAA Y S 1 OOA6 related with ocular surface (dry eye), for this work PLAA (phospholipase A2) is studied by means of label free biosensing based on BICELLs for analyzing the performance and specificity according with means values of concentration in ROC curves.