991 resultados para heart valve prostheses


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the influence of oral contraceptives (OCs) containing 20 mu mu g ethinylestradiol (EE) and 150 mu mu g gestodene (GEST) on the autonomic modulation of heart rate (HR) in women. Methods One-hundred and fifty-five women aged 24 +/-+/- 2 years were divided into four groups according to their physical activity and the use or not of an OC: active-OC, active-non-OC (NOC), sedentary-OC, and sedentary-NOC. The heart rate was registered in real time based on the electrocardiogram signal for 15 minutes, in the supine-position. The heart rate variability (HRV) was analysed using Shannon`s entropy (SE), conditional entropy (complexity index [CInd] and normalised CInd [NCI]), and symbolic analysis (0V%, 1V%, 2LV%, and 2ULV%). For statistical analysis the Kruskal-Wallis test with Dunn post hoc and the Wilcoxon test (p < 0.05 was considered significant) were applied. Results Treatment with this COC caused no significant changes in SE, CInd, NCI, or symbolic analysis in either active or sedentary groups. Active groups presented higher values for SE and 2ULV%, and lower values for 0V% when compared to sedentary groups (p < 0.05). Conclusion HRV patterns differed depending on life style; the non-linear method applied was highly reliable for identifying these changes. The use of OCs containing 20 mu mu g EE and 150 mu mu g GEST does not influence HR autonomic modulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aims of this study were to assess the feasibility of performing a complete fetal echocardiographic study during the first trimester of pregnancy, to establish the best week to accomplish a complete evaluation, and to find a relationship between the diameters of the cardiac valves and gestational age. Methods: 46 fetuses with normal nuchal translucency and venous duct Doppler velocimetry were submitted to echocardiographic studies by the transvaginal approach between the 11 + 0 and 14 + 6 weeks of gestation. A complete echocardiographic evaluation was defined as an examination in which the three basic planes, four-chamber, longitudinal and short-axis views, were obtained. Results: The rates of complete echocardiography evaluation were 37, 85 and 100% at 11, 12 and 13-14 weeks, respectively. The longitudinal view was the easiest to obtain and the short-axis view was the most difficult one. The diameter of the cardiac valves was compared with the crown-rump length (CRL) and there was no statistically significant difference between either the diameters of the mitral and tricuspid or the aortic and pulmonary valves. A linear growth curve was constructed to demonstrate the diameter correlations. Conclusions: The study demonstrated the feasibility of a complete fetal echocardiographic evaluation by the transvaginal approach during the first trimester of gestation. The rate of a complete evaluation increased along the period and reached 100% when the CRL was 64 mm or 13 weeks of gestational age. There was a linear correlation between the cardiac valve diameters and the CRL revealing a relationship between the cardiac and fetal development. The absence of a statistically significant difference between the left and right valve dimensions possibly means that there is no predominance of right or left chambers during this period of evaluation. Copyright (C) 2007 S. Karger AG, Basel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated whether there is an association between anxiety disorders and mitral valve prolapse. We compared mitral valve prolapse prevalence in individuals with panic disorder (n=41), social anxiety disorder (n=89) and in healthy controls (n=102) in an attempt to overcome the biases of previous studies. Our results show no associations between panic disorder or social anxiety disorder and mitral valve prolapse, regardless of the diagnostic criteria employed, and that the relationship between these conditions seems not to be clinically relevant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Noninvasive assessment of cardiac structure and function is essential to understand the natural course of murine infection with Trypanosoma cruzi. Magnetic resonance imaging (MRI) and echocardiography have been used to monitor anatomy and function; positron emission tomography (PET) is ideal for monitoring metabolic events in the myocardium. Mice infected with T. cruzi (Brazil strain) were imaged 15-100 days post infection (dpi). Quantitative (18)F-FDG microPET imaging, MRI and echocardiography were performed and compared. Tracer ((18)F-FDG) uptake was significantly higher in infected mice at all days of infection, from 15 to 100 dpi. Dilatation of the right ventricular chamber was observed by MRI from 30 to 100 dpi in infected mice. Echocardiography revealed significantly reduced ejection fraction by 60 dpi. Combination of these three complementary imaging modalities makes it possible to noninvasively quantify cardiovascular function, morphology, and metabolism from the earliest days of infection through the chronic phase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prostacyclin (PgI(2)) and endothelium-derived nitric oxide (EDNO) are produced by the arterial and venous endothelium. In addition to their vasodilator action on vascular smooth muscle, both act together to inhibit platelet aggregation and promote platelet disaggregation. EDNO also inhibits platelet adhesion to the endothelium. EDNO and PgI(2) have been shown to be released from the cultured endocardial cells. In this study, we examined the release of vasoactive substances from the intact endocardium by using isolated rabbit hearts perfused with physiological salt solution (95% O(2)/5% CO(2), T = 37 degrees C). The right and left cardiac chambers were perfused through separate constant-flow perfusion loops (physiological salt solution, 8 ml min(-1)). Effluent from left and right cardiac, separately, was bioassayed on canine coronary artery smooth muscle, which had been contracted with prostaglandin F(2 alpha_)(2 x 10(-6) M) and no change in tension was exhibit. However, addition of calcium ionophore A23187 (10(-6) M) to the cardiac chambers` perfusion line induced vasodilation of the bioassay coronary ring, 61.4 +/- 7.4% versus 70.49 +/- 6.1% of initial prostaglandin F(2 alpha) contraction for the left and right cardiac chambers perfusate, respectively (mean +/- SEM, n = 10, p > 0.05). Production of vasodilator was blocked totally in the left heart but, only partially blocked in the right heart by adding indomethacin (10(-5) M) to the perfusate, respectively, 95.2 +/- 2.2% versus 41.5 +/- 4.8% (mean +/- SEM, n = 10, p < 0.05). 6-Keto prostaglandin F(1 alpha), measured in the endocardial superfusion effluent was also higher for the left cardiac chambers than for the right at the time of stimulation with the A23187, respectively, 25385.88 +/- 5495 pg/ml (n = 8) versus 13,132.45 +/- 1839.82 pg/ml (n = 8), (p < 0.05). These results showed that cyclooxygenase pathway plays major role in generating vasoactive substances for the left cardiac chamber endocardium; while it is not the main pathway for the right ventricular endocardium at which EDNO and PgI(2) Could act together and potentiate their antithrombogenic activities in isolated perfused rabbit heart. This may be an explanation for the intraventricular thrombus mostly seen in left ventricle rather than in right ventricle as a complication of myocardial infarction. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was conducted in one kidney, one clip (1K1C) Goldblatt hypertensive rats to evaluate vascular and cardiac autonomic control using different approaches: 1) evaluation of the autonomic modulation of heart rate (HR) and systolic arterial pressure (SAP) by means of autoregressive power spectral analysis 2) assessment of the cardiac baroreflex sensitivity; and 3) double blockade with methylatropine and propranolol. The 1K1C group developed hypertension and tachycardia. The 1K1C group also presented reduction in variance as well as in LF (0.23 +/- 0.1 vs. 1.32 +/- 0.2 ms(2)) and HF (6.6 +/- 0.49 vs. 15.1 +/- 0.61 ms(2)) oscillations of pulse interval. Autoregressive spectral analysis of SAP showed that 1K1C rats had an increase in variance and LF band (13.3 +/- 2.7 vs. 7.4 +/- 1.01 mmHg(2)) in comparison with the sham group. The baroreflex gain was attenuated in the hypertensive 1K1C (- 1.83 +/- 0.05 bpm/mmHg) rats in comparison with normotensive sham (-3.23 +/- 0.06 bpm/MmHg) rats. The autonomic blockade caused an increase in the intrinsic HR and sympathetic predominance on the basal HR of 1K1C rats. Overall, these data indicate that the tachycardia observed in the 1K1C group may be attributed to intrinsic cardiac mechanisms (increased intrinsic heart rate) and to a shift in the sympathovagal balance towards cardiac sympathetic over-activity and vagal suppression associated to depressed baroreflex sensitivity. Finally, the increase in the LF components of SAP also suggests an increase in sympathetic activity to peripheral vessels. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Although the influence of respiration on ventricular filling, as evaluated by Doppler technique, and the evaluation of diastolic velocities of mitral valve annulus (MVA), as measured by Doppler tissue imaging (DTI), can provide valuable information for the study of left ventricular (LV) diastolic function, the concomitant effects of aging, tidal volume (TV), and respiratory rate (RR) on these velocities have not been quantitatively investigated. Methods: We evaluated 12 normal male volunteers (Group I) aged 20-26 years (mean: 22.8) and 8 normal subjects aged 41 to 54 years old (mean: 45.9) (Group II). Using DTI we measured peak early (E-a) and late (A(a)) velocities of longitudinal axis expansion at lateral and medial MVA. Doppler mitral and tricuspid flow velocities were measured: peak early (E) and late (A) inflow velocity, early (E-i) and late (A(i)) flow integral, and deceleration time of peak early mitral flow velocity (DT). Respiratory cycles were simultaneously recorded at RR of 9, 12, 15, and 18 cycles/min and TV of 600 and 900 mL during respiration (RESP). Results and conclusions: (1) E, A, and A(i) in MV had negligible change during respiration, but E-i was significantly reduced during inspiration; (2) DT reduced slightly with inspiration, but the change was significant only with TV of 900 mL; (3) an important increase of E in right ventricular flow was observed during inspiration; (4) variations of RR and TV did not significantly influence right and left ventricular inflow in normal subjects, in the conditions of this investigation; (5) a significant increase of E-a at medial MVA was documented during inspiration only in young subjects; (6) a significant decrease of A(a) at medial MVA was observed during inspiration in both groups of volunteers; (7) RR and TV did not influence MVA velocities in young and adult subjects; (8) a consistent reduction in E-a and a significant increase in A(a) were observed with increasing age; (9) these changes were more conspicuous and consistent than those documented in ventricular filling when young and middle-age men are compared, suggesting that the DTI is more sensitive to detect changes in diastolic function; and (10) in addition, these data suggest that, for evaluation of diastolic function, in clinical context, it is not necessary to control rigorously RR or TV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interventional cardiology for paediatric and congenital cardiac disease is a relatively young and rapidly evolving field. As the profession begins to establish multi-institutional databases, a universal system of nomenclature is necessary for the field of interventional cardiology for paediatric and congenital cardiac disease. The purpose of this paper is to present the results of the efforts of The International Society for Nomenclature of Paediatric and Congenital Heart Disease to establish a system of nomenclature for cardiovascular catheterisation for congenital and paediatric cardiac disease, focusing both on procedural nomenclature and on the nomenclature of complications associated with interventional cardiology. This system of nomenclature for cardiovascular catheterisation for congenital and paediatric cardiac disease is a component of The International Paediatric and Congenital Cardiac Code. This manuscript is the first part of a two-part series. Part 1 will cover the procedural nomenclature associated with interventional cardiology as treatment for paediatric and congenital cardiac disease. This procedural nomenclature of The International Paediatric and Congenital Cardiac Code will be used in the IMPACT Registry (TM) (IMproving Pediatric and Adult Congenital Treatment) of the National Cardiovascular Data Registry (R) of The American College of Cardiology. Part 2 will cover the nomenclature of complications associated with interventional cardiology as treatment for paediatric and congenital cardiac disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interventional cardiology for paediatric and congenital cardiac disease is a relatively young and rapidly evolving field. As the profession begins to establish multi-institutional databases, a universal system of nomenclature is necessary for the field of interventional cardiology for paediatric and congenital cardiac disease. The purpose of this paper is to present the results of the efforts of The International Society for Nomenclature of Paediatric and Congenital Heart Disease to establish a system of nomenclature for cardiovascular catheterisation for congenital and paediatric cardiac disease, focusing both on procedural nomenclature and the nomenclature of complications associated with interventional cardiology. This system of nomenclature for cardiovascular catheterisation for congenital and paediatric cardiac disease is a component of The International Paediatric and Congenital Cardiac Code. This manuscript is the second part of the two-part series. Part 1 covered the procedural nomenclature associated with interventional cardiology as treatment for paediatric and congenital cardiac disease. Part 2 will cover the nomenclature of complications associated with interventional cardiology as treatment for paediatric and congenital cardiac disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. aEuro integral Heart rate variability (HRV) decreases after an acute myocardial infarction (AMI) due to changes in cardiac autonomic balance. The purpose of the present study, therefore, was to evaluate the effects of a progressive exercise protocol used in phase I cardiac rehabilitation on the HRV of patients with post-AMI. Material and methods. aEuro integral Thirty-seven patients who had been admitted to hospital with their first non-complicated AMI were studied. The treated group (TG, n == 21, age == 52 +/-+/- 12 years) performed a 5-day programme of progressive exercise during phase I cardiac rehabilitation, while the control group (CG, n == 16, age == 54 +/-+/- 11 years) performed only respiratory exercises. Instantaneous heart rate (HR) and RR interval were acquired by a HR monitor (Polar (R) A (R) S810i). HRV was analysed by frequency domain methods. Power spectral density was expressed as normalised units (nu) at low (LF) and high (HF) frequencies, and as LF/HF. Results. aEuro integral After 5 days of progressive exercise, the TG showed an increase in HFnu (35.9 +/-+/- 19.5 to 65.19 +/-+/- 25.4) and a decrease in LFnu and LF/HF (58.9 +/-+/- 21.4 to 32.5 +/-+/- 24.1; 3.12 +/-+/- 4.0 to 1.0 +/-+/- 1.5, respectively) in the resting position (p < 0.05). No changes were observed in the CG. Conclusions. aEuro integral A progressive physiotherapeutic exercise programme carried out during phase I cardiac rehabilitation, as supplement to clinical treatment increased vagal and decreased sympathetic cardiac modulation in patients with post-AMI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diagnosis and treatment for paediatric and congenital cardiac disease has undergone remarkable progress over the last 60 years. Unfortunately, this progress has been largely limited to the developed world. Yet every year approximately 90% of the more than 1,000,000 children who are born with congenital cardiac disease across the world receive either suboptimal care or are totally denied care. While in the developed world the focus has changed from an effort to decrease post-operative mortality to now improving quality of life and decreasing morbidity, which the focus of this Supplement, the rest of the world still needs to develop basic access to congenital cardiac care. The World Society for Pediatric and Congenital Heart Surgery [http://www.wspchs.org/] was established in 2006. The Vision of the World Society is that every child born anywhere in the world with a congenital heart defect should have access to appropriate medical and surgical care. The Mission of the World Society is to promote the highest quality comprehensive care to all patients with pediatric and/or congenital heart disease, from the fetus to the adult, regardless of the patient`s economic means, with emphasis on excellence in education, research and community service. We present in this article an overview of the epidemiology of congenital cardiac disease, the current and future challenges to improve care in the developed and developing world, the impact of the globalization of cardiac surgery, and the role that the World Society should play. The World Society for Pediatric and Congenital Heart Surgery is in a unique position to influence and truly improve the global care of children and adults with congenital cardiac disease throughout the world [http://www.wspchs.org/].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this research was to assess the dimensional accuracy of orbital prostheses based on reversed images generated by computer-aided design/computer-assisted manufacturing (CAD/CAM) using computed tomography (CT) scans. Materials and Methods: CT scans of the faces of 15 adults, men and women older than 25 years of age not bearing any congenital or acquired craniofacial defects, were processed using CAD software to produce 30 reversed three-dimensional models of the orbital region. These models were then processed using the CAM system by means of selective laser sintering to generate surface prototypes of the volunteers` orbital regions. Two moulage impressions of the faces of each volunteer were taken to manufacture 15 pairs of casts. Orbital defects were created on the right or left side of each cast. The surface prototypes were adapted to the casts and then flasked to fabricate silicone prostheses. The establishment of anthropometric landmarks on the orbital region and facial midline allowed for the data collection of 31 linear measurements, used to assess the dimensional accuracy of the orbital prostheses and their location on the face. Results: The comparative analyses of the linear measurements taken from the orbital prostheses and the opposite sides that originated the surface prototypes demonstrated that the orbital prostheses presented similar vertical, transversal, and oblique dimensions, as well as similar depth. There was no transverse or oblique displacement of the prostheses. Conclusion: From a clinical perspective, the small differences observed after analyzing all 31 linear measurements did not indicate facial asymmetry. The dimensional accuracy of the orbital prostheses suggested that the CAD/CAM system assessed herein may be applicable for clinical purposes. Int J Prosthodont 2010;23:271-276.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Retention systems for implant-retained auricular prostheses using either bar-clip attachments with 2 or 3 clips or retention with 2 or 3 magnets were wear tested (insertion and removal cycles) to simulate clinical periods of use. Measurements were taken at intervals of 540 cycles, which represents a period of use of approximately 6 months, for up to 3,240 cycles. Assessments of retentive force were carried out before, during, and after the wear test. Statistical analysis indicated that the bar-clip systems provided higher retention than the magnetic systems. The bar-clip attachment with 2 clips showed a significant loss of retentive force after wear testing (P < .05), suggesting lower durability and shorter clinical life. The retention provided by the bar-clip attachment with 3 clips remained stronger than that provided by all other systems tested. At the end of the wear test, the magnetic systems showed very little loss of retention but were still less retentive than the bar-clip systems, suggesting higher durability under clinical simulation despite the lower retention initially provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Provision of an inert gas atmosphere with high-purity argon gas is recommended for preventing titanium castings from contamination although the effects of the level of argon purity on the mechanical properties and the clinical performance of Ti castings have not yet been investigated. The purpose of this study was to evaluate the effect of argon purity on the mechanical properties and microstructure of commercially pure (cp) Ti and Ti-6Al-4V alloys. The castings were made using either high-purity and/or industrial argon gas. The ultimate tensile strength (UTS), proportional limit (PL), elongation (EL) and microhardness (VHN) at different depths were evaluated. The microstructure of the alloys was also revealed and the fracture mode was analyzed by scanning electron microscopy. The data from the mechanical tests and hardness were subjected to a two-and three-way ANOVA and Tukey`s test (alpha = 0.05). The mean values of mechanical properties were not affected by the argon gas purity. Higher UTS, PL and VHN, and lower EL were observed for Ti-6Al-4V. The microhardness was not influenced by the argon gas purity. The industrial argon gas can be used to cast cp Ti and Ti-6Al-4V.