890 resultados para guided-wave optics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Water withdrawal from Mediterranean reservoirs in summer is usually very high. Because of this, stratification is often continuous and far from the typical two-layered structure, favoring the excitation of higher vertical modes. The analysis of wind, temperature, and current data from Sau reservoir (Spain) shows that the third vertical mode of the internal seiche (baroclinic mode) dominated the internal wave field at the beginning of September 2003. We used a continuous stratification two-dimensional model to calculate the period and velocity distribution of the various modes of the internal seiche, and we calculated that the period of the third vertical mode is ;24 h, which coincides with the period of the dominating winds. As a result of the resonance between the third mode and the wind, the other oscillation modes were not excited during this period

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction : Le bloc transverse de l'abdomen (bloc TAP, Transversus Abdominis Plane) échoguidé consiste en l'injection d'anesthésique local dans la paroi abdominale entre les muscles oblique interne et transverse de l'abdomen sous contrôle échographique. Ceci permet de bloquer l'innervation sensitive de la paroi antérolatérale de l'abdomen afin de soulager la douleur après des interventions chirurgicales. Auparavant, cette procédure reposait sur une technique dite « à l'aveugle » qui utilisait des repères anatomiques de surface. Depuis quelques années, cette technique est effectuée sous guidage échographique ; ainsi, il est possible de visualiser les structures anatomiques, l'aiguille et l'anesthésique local permettant ainsi une injection précise de l'anesthésique local à l'endroit désiré. Les précédentes méta- analyses sur le bloc TAP n'ont inclus qu'un nombre limité d'articles et n'ont pas examiné l'effet analgésique spécifique de la technique échoguidée. L'objectif de cette méta-analyse est donc de définir l'efficacité analgésique propre du bloc TAP échoguidé après des interventions abdominales chez une population adulte. Méthode : Cette méta-analyse a été effectuée selon les recommandations PRISMA. Une recherche a été effectuée dans les bases de donnée MEDLINE, Cochrane Central Register of Controlled Clinical Trials, Excerpta Medica database (EMBASE) et Cumulative Index to Nursing and Allied Health Literature (CINAHL). Le critère de jugement principal est la consommation intraveineuse de morphine cumulée à 6 h postopératoires, analysée selon le type de chirurgie (laparotomie, laparoscopie, césarienne), la technique anesthésique (anesthésie générale, anesthésie spinale avec/ou sans morphine intrathécale), le moment de l'injection (début ou fin de l'intervention), et la présence ou non d'une analgésie multimodale. Les critères de jugement secondaires sont, entre autres, les scores de douleur au repos et à l'effort à 6 h postopératoires (échelle analogique de 0 à 100), la présence ou non de nausées et vomissements postopératoires, la présence ou non de prurit, et le taux de complications de la technique. Résultats : Trente et une études randomisées contrôlées, incluant un total de 1611 adultes ont été incluses. Indépendamment du type de chirurgie, le bloc TAP échoguidé réduit la consommation de morphine à 6 h postopératoires (différence moyenne : 6 mg ; 95%IC : -7, -4 mg ; I =94% ; p<0.00001), sauf si les patients sont au bénéfice d'une anesthésie spinale avec morphine intrathécale. Le degré de réduction de consommation de morphine n'est pas influencé par le moment de l'injection (I2=0% ; p=0.72) ou la présence d'une analgésie multimodale (I2=73% ; p=0.05). Les scores de douleurs au repos et à l'effort à 6h postopératoire sont également réduits (différence moyenne au repos : -10 ; 95%IC : -15, -5 ; I =92% ; p=0.0002; différence moyenne en mouvement : -9 ; 95%IC : -14, -5 ; I2=58% ; p<0. 00001). Aucune différence n'a été retrouvée au niveau des nausées et vomissements postopératoires et du prurit. Deux complications mineures ont été identifiées (1 hématome, 1 réaction anaphylactoïde sur 1028 patients). Conclusions : Le bloc TAP échoguidé procure une analgésie postopératoire mineure et ne présente aucun bénéfice chez les patients ayant reçu de la morphine intrathécale. L'effet analgésique mineure est indépendant du moment de l'injection ou de la présence ou non d'une analgésie multimodale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Image segmentation of natural scenes constitutes a major problem in machine vision. This paper presents a new proposal for the image segmentation problem which has been based on the integration of edge and region information. This approach begins by detecting the main contours of the scene which are later used to guide a concurrent set of growing processes. A previous analysis of the seed pixels permits adjustment of the homogeneity criterion to the region's characteristics during the growing process. Since the high variability of regions representing outdoor scenes makes the classical homogeneity criteria useless, a new homogeneity criterion based on clustering analysis and convex hull construction is proposed. Experimental results have proven the reliability of the proposed approach

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In terms of the Fourier spectrum, a simple but general analytical expression is given for the evanescent field associated to a certain kind of non-paraxial exact solutions of the Maxwell equations. This expression enables one to compare the relative weight of the evanescent wave with regard to the propagating field. In addition, in those cases in which the evanescent term is significant, the magnitude of the field components across the transverse profile (including the evanescent features) can be determined. These results are applied to some illustrative examples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this project is to accomplish an application software based on Matlab to calculate the radioelectrical coverage by surface wave of broadcast radiostations in the band of Medium Wave (WM) all around the world. Also, given the location of a transmitting and a receiving station, the software should be able to calculate the electric field that the receiver should receive at that specific site. In case of several transmitters, the program should search for the existence of Inter-Symbol Interference, and calculate the field strenght accordingly. The application should ask for the configuration parameters of the transmitter radiostation within a Graphical User Interface (GUI), and bring back the resulting coverage above a map of the area under study. For the development of this project, it has been used several conductivity databases of different countries, and a high-resolution elevation database (GLOBE). Also, to calculate the field strenght due to groundwave propagation, it has been used ITU GRWAVE program, which must be integrated into a Matlab interface to be used by the application developed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical method for the determination of the anti-inflammatory drug 5-aminosalicylic acid (5-ASA) in pharmaceutical formulations using square wave voltammetry at pencil graphite electrodes was developed. After the optimization of the experimental conditions, calibration curves were obtained in the linear concentration range from 9.78 × 10-7 to 7.25 × 10-5 mol L-1 resulting in a limit of detection of 2.12 ± 0.05 x 10-8 mol L-1. Statistical tests showed that the concentrations of 5-ASA in commercial tablets and enemas obtained with the proposed voltammetric method agreed with HPLC values at a 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple procedure is described for the determination of scopolamine by square-wave voltammetry using a cathodically pretreated boron-doped diamond electrode. Cyclic voltammetry studies indicate that the oxidation of scopolamine is irreversible at a peak potential of 1.59 V (vs. Ag/AgCl (3.0 mol L-1 KCl)) in a 0.50 mol L-1 sulfuric acid solution. Under optimized conditions, the analytical curve obtained was linear (r = 0.9996) for the scopolamine concentration range of 1.0 to 110 µmol L-1, with a detection limit of 0.84 µmol L-1. The method was successfully applied to the determination of scopolamine in pharmaceutical formulations with minimum sample preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents an electroanalytical method for the determination of moxifloxacin (MOXI) in tablets by its interaction with Cu(II) ion and subsequent electrochemical reduction at hanging mercury drop electrode (HMDE). A well-defined reduction peak at -0.21 V vs. Ag/AgCl in Phosphate buffer 0.04 mol L-1 pH 8.0 was observed for the complex reduction MOXI-Cu(II), using square-wave voltammetry (SWV). Using a 10 s of accumulation time at -0.40 V was found a limit detection of 3.60x10-8 mol l-1. The obtained results have shown good agreement with those obtained by spectrophotometric method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to a better characterization of a graphite-polyurethane composite intended to be used as a voltammetric sensor, the performance in a square wave voltammetric procedure was investigated. Using hydroquinone (HQ) as a probe, the electrode showed to be useful in square wave voltammetry with limit of detection of 0.28 µmol L-1, with recoveries between 99.1 and 101.5%. The results of the proposed method agreed with HPLC ones within 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As vigas estruturais de madeira são formas racionais do emprego da madeira na construção de estruturas, sendo obtidas pela associação de peças serradas e permitindo a utilização de tábuas com seções e comprimentos variados, além de combinações com madeira de qualidade diferenciada. Para atingir a resistência máxima de uma viga de madeira laminada colada, pode-se utilizar a classificação mecânica das peças por meio dinâmico. O objetivo deste estudo foi estabelecer correlação entre os métodos estático e dinâmico de classificação de vigas de madeira laminada. O trabalho foi desenvolvido com o emprego de peças de madeira serrada de Pinus taeda e adesivo resorcina fenolformaldeído. O processo de fabricação das vigas envolveu a classificação das peças, usinagem de emendas, formação das lamelas, montagem e prensagem das vigas. Já os ensaios envolveram a determinação do módulo de elasticidade por meio do ''stress wave method'' e de uma máquina universal de ensaios. Os resultados foram analisados pela análise de regressão do estabelecimento da equação de ajuste de correlação. O sistema de classificação visual utilizado na seleção de peças foi insuficiente para se atingirem os valores máximos de módulo de elasticidade; o posicionamento correto das lamelas por meio do método dinâmico de classificação teve como consequência direta o aumento do módulo de elasticidade da viga, e houve baixa correlação entre as formas de obtenção do módulo de elasticidade das vigas, não sendo possível a elaboração de equação adequada entre os métodos testados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foram avaliadas as propriedades físicas e mecânicas de compósitos LVL produzidos com a madeira de paricá (Schizolobium amazonicum Huber ex. Ducke), por meio de Stress Wave Timer. Os compósitos foram confeccionados em laboratório, dos quais foram retiradas amostras, que foram inicialmente destinadas à realização dos ensaios não destrutivos. Todas as amostras, com dimensões de 2,2 × 2,2 × 40 cm, foram ensaiadas, não destrutivamente, com a propagação de ondas nos sentidos flatwise e edgewise. Em sequência, as mesmas amostras foram destinadas à confecção de subamostras, para realização dos ensaios destrutivos, físicos (absorção de água, inchamento em espessura e inchamento residual) e mecânicos (resistência e rigidez à flexão estática flatwise; resistência e rigidez à flexão estática edgewise; resistência à compressão paralela e resistência ao cisalhamento paralelo e perpendicular). A velocidade de propagação das ondas (V0) e o módulo de elasticidade dinâmico (Emd), obtidos com o auxílio do Stress Wave, foram utilizados para elaboração de modelos de predição das propriedades avaliadas. Os resultados indicaram que o Stress Wave Timer apresenta resultados satisfatórios para predição das propriedades mecânicas de compósitos LVL. Com relação às propriedades físicas, embora tenham sido verificados modelos com ajustes significativos, constatou-se limitação dessa ferramenta para predição desses parâmetros. Contudo, considerando ambas as propriedades, físicas e mecânicas, os melhores ajustes foram observados em amostras ensaiadas com a propagação de ondas no sentido edgewise e com o uso da variável independente Emd.