975 resultados para depth perception


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wavefront coding is a powerful technique that can be used to extend the depth of field of an incoherent imaging system. By adding a suitable phase mask to the aperture plane, the optical transfer function of a conventional imaging system can be made defocus invariant. Since 1995, when a cubic phase mask was first suggested, many kinds of phase masks have been proposed to achieve the goal of depth extension. In this Letter, a phase mask based on sinusoidal function is designed to enrich the family of phase masks. Numerical evaluation demonstrates that the proposed mask is not only less sensitive to focus errors than cubic, exponential, and modified logarithmic masks are, but it also has a smaller point-spread-function shifting effect. (C) 2010 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wave-front coding is a well known technique used to extend the depth of field of incoherent imaging system. The core of this technique lies in the design of suitable phase masks, among which the most important one is the cubic phase mask suggested by Dowski and Cathey (1995) [1]. In this paper, we propose a new type called cubic sinusoidal phase mask which is generated by combing the cubic one and another component having the sinusoidal form. Numerical evaluations and real experimental results demonstrate that the composite phase mask is superior to the original cubic phase mask with parameters optimized and provides another choice to achieve the goal of depth extension. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here we used cytokinesis-block micronucleus assay to measure the biological response along the penetrate depth of ions in water in human lymphocytes exposed to 100 MeV/u incident carbon ions in vitro. Polyethylene shielding was used to change the penetration depth of ions in water. A quantitative biological response curve was generated for micronuclei induction. The results showed a marked increase with the penetrate depth of ions in water in the micronuclei formation, which was consistent with a linearenergy- transfer dependent increase in biological effectiveness. The dose–response relationship for MN information was different at different penetrate depth of ions in water, at the 6 and 11.2 mm penetrate depth of ions in water, the dose–response relationships for the micronucleus frequencies induced by carbon ions irradiation were linear; while it was power function at 17.1 mm penetrate depth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Treatment planning of heavy-ion radiotherapy involves predictive calculation of not only the physical dose but also the biological dose in a patient body. The goal in designing beam-modulating devices for heavy ion therapy is to achieve uniform biological effects across the spread-out Bragg peak (SOBP). To achieve this, a mathematical model of Bragg peak movement is presented. The parameters of this model have been resolved with Monte Carlo method. And a rotating wheel filter is designed basing on the velocity of the Bragg peak movement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

National Natural Science Foundation of China [40701021, 40625002, 40331013]; National Knowledge Innovation Program of Chinese Academy of Sciences [KZCX2-YW-315-2]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is important to detect the aromaticity of structures during the process of structure elucidation and output. In this paper, an alogrithm was proposed to detect the aromaticity of structures by the use of algorithm on ring identification. The results show that it could be used to identify most of the aromatic structure. It have been used as constraints of Expert System on Elucidation Structure of Organic Compounds(ESESOC) and a good result has been achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It's important to identify ring in the process of structure elucidation. In this paper, all rings and the smallest set of smallest ring(SSSR) of structure are obtained from two-dimensional connection table. The results are satisfactory by using this algorithm in ESESOC expert system as constraint.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the development of our ESESOC system (Expert System for the Elucidation of the Structures of Organic Compounds), computer perception of topological symmetry is essential in searching for the canonical description of a molecular structure, removing the irredundant connections in the structure generation process, and specifying the number of peaks in C-13- and H-1-NMR spectra in the structure evaluation process. In the present paper, a new path identifier is introduced and an algorithm for detection of topological symmetry from a connection table is developed by the all-paths method. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new algorithm for computer perception of topological symmetry is proposed. A node library containing various kinds of nodes is built, and the index number of the library is used as initial atom class identifier (CI) to discriminate the different types of non-hydrogen atoms. The path index (PI) and ringindex (RI) are calculated from the CI, and the global topological enviroment is defined as the sum of PIs and RIs. The topological symmetry can be detected by the iterative calculation of the global topological enviroment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the exhaustive and irredundant generation of candidate structures in ESESOC (Expert System for the Elucidation of the Structures of Organic Compounds), a new algorithm for computer perception of topological equivalence classes of the nodes (non-hydrog