855 resultados para SYSTEMATIC-ERROR CORRECTION


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Observational evidence consistently shows that consumption of a diet rich in fruit and vegetables may offer protection against diseases such as cardiovascular disease and cancer. Assessment of dietary intake is complex and prone to many sources of error. More objective biomarkers of fruit and vegetable intake are therefore of interest. The aim of this review is to examine the usefulness of the main biomarkers of fruit and vegetable intake to act as objective indicators of compliance in dietary intervention studies. A comprehensive search of the literature was conducted using six databases. Suitable papers were selected and relevant data extracted. The papers were categorized into 3 sub-groups: whole diet interventions; mixed fruit and vegetable interventions; and studies involving individual varieties of fruits or vegetables. Ninety-six studies were included in the review. Overall, the most commonly measured, and most consistently responsive, biomarkers were the carotenoids and vitamin C. Based on the results of this systematic review, it remains prudent to measure a panel of biomarkers in fruit and vegetable intervention studies. The only possible exception to this is “fruit only” intervention studies where assessment of vitamin C alone may suffice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: There is growing interest in the potential utility of real-time polymerase chain reaction (PCR) in diagnosing bloodstream infection by detecting pathogen deoxyribonucleic acid (DNA) in blood samples within a few hours. SeptiFast (Roche Diagnostics GmBH, Mannheim, Germany) is a multipathogen probe-based system targeting ribosomal DNA sequences of bacteria and fungi. It detects and identifies the commonest pathogens causing bloodstream infection. As background to this study, we report a systematic review of Phase III diagnostic accuracy studies of SeptiFast, which reveals uncertainty about its likely clinical utility based on widespread evidence of deficiencies in study design and reporting with a high risk of bias. 

Objective: Determine the accuracy of SeptiFast real-time PCR for the detection of health-care-associated bloodstream infection, against standard microbiological culture. 

Design: Prospective multicentre Phase III clinical diagnostic accuracy study using the standards for the reporting of diagnostic accuracy studies criteria. 

Setting: Critical care departments within NHS hospitals in the north-west of England. 

Participants: Adult patients requiring blood culture (BC) when developing new signs of systemic inflammation. 

Main outcome measures: SeptiFast real-time PCR results at species/genus level compared with microbiological culture in association with independent adjudication of infection. Metrics of diagnostic accuracy were derived including sensitivity, specificity, likelihood ratios and predictive values, with their 95% confidence intervals (CIs). Latent class analysis was used to explore the diagnostic performance of culture as a reference standard. 

Results: Of 1006 new patient episodes of systemic inflammation in 853 patients, 922 (92%) met the inclusion criteria and provided sufficient information for analysis. Index test assay failure occurred on 69 (7%) occasions. Adult patients had been exposed to a median of 8 days (interquartile range 4–16 days) of hospital care, had high levels of organ support activities and recent antibiotic exposure. SeptiFast real-time PCR, when compared with culture-proven bloodstream infection at species/genus level, had better specificity (85.8%, 95% CI 83.3% to 88.1%) than sensitivity (50%, 95% CI 39.1% to 60.8%). When compared with pooled diagnostic metrics derived from our systematic review, our clinical study revealed lower test accuracy of SeptiFast real-time PCR, mainly as a result of low diagnostic sensitivity. There was a low prevalence of BC-proven pathogens in these patients (9.2%, 95% CI 7.4% to 11.2%) such that the post-test probabilities of both a positive (26.3%, 95% CI 19.8% to 33.7%) and a negative SeptiFast test (5.6%, 95% CI 4.1% to 7.4%) indicate the potential limitations of this technology in the diagnosis of bloodstream infection. However, latent class analysis indicates that BC has a low sensitivity, questioning its relevance as a reference test in this setting. Using this analysis approach, the sensitivity of the SeptiFast test was low but also appeared significantly better than BC. Blood samples identified as positive by either culture or SeptiFast real-time PCR were associated with a high probability (> 95%) of infection, indicating higher diagnostic rule-in utility than was apparent using conventional analyses of diagnostic accuracy. 

Conclusion: SeptiFast real-time PCR on blood samples may have rapid rule-in utility for the diagnosis of health-care-associated bloodstream infection but the lack of sensitivity is a significant limiting factor. Innovations aimed at improved diagnostic sensitivity of real-time PCR in this setting are urgently required. Future work recommendations include technology developments to improve the efficiency of pathogen DNA extraction and the capacity to detect a much broader range of pathogens and drug resistance genes and the application of new statistical approaches able to more reliably assess test performance in situation where the reference standard (e.g. blood culture in the setting of high antimicrobial use) is prone to error.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: This systematic review reports on the survival of feldspathic porcelain veneers.

MATERIALS AND METHODS: The Cochrane Library, MEDLINE (OVID), Embase, Web of Knowledge, selected journals, clinical trials registers, and conference proceedings were searched independently by two reviewers. Academic colleagues were also contacted to identify relevant research. Inclusion criteria were human cohort studies (prospective and retrospective) and controlled trials assessing outcomes of feldspathic porcelain veneers in more than 15 patients and with at least some of the veneers in situ for 5 years. Of 4,294 articles identified, 116 studies underwent full-text screenings and 69 were further reviewed for eligibility. Of these, 11 were included in the qualitative analysis and 6 (5 cohorts) were included in meta-analyses. Estimated cumulative survival and standard error for each study were assessed and used for meta-, sensitivity, and post hoc analyses. The I2 statistic and the Cochran Q test and its associated P value were used to evaluate statistical heterogeneity, with a random-effects meta-analysis used when the P value for heterogeneity was less than .1. Galbraith, forest, and funnel plots explored heterogeneity, publication patterns, and small study biases.

RESULTS: The estimated cumulative survival for feldspathic porcelain veneers was 95.7% (95% confidence interval [CI]: 92.9% to 98.4%) at 5 years and ranged from 64% to 95% at 10 years across three studies. A post hoc meta-analysis indicated that the 10-year best estimate may approach 95.6% (95% CI: 93.8% to 97.5%). High levels of statistical heterogeneity were found.

CONCLUSIONS: When bonded to enamel substrate, feldspathic porcelain veneers have a very high 10-year survival rate that may approach 95%. Clinical heterogeneity is associated with differences in reported survival rates. Use of clinically relevant survival definitions and careful reporting of tooth characteristics, censorship, clustering, and precise results in future research would improve metaanalytic estimates and aid treatment decisions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we introduce a statistical data-correction framework that aims at improving the DSP system performance in presence of unreliable memories. The proposed signal processing framework implements best-effort error mitigation for signals that are corrupted by defects in unreliable storage arrays using a statistical correction function extracted from the signal statistics, a data-corruption model, and an application-specific cost function. An application example to communication systems demonstrates the efficacy of the proposed approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate visual acuity, visual function, and prevalence of refractive error among Chinese secondary-school children in a cross-sectional school-based study. METHODS: Uncorrected, presenting, and best corrected visual acuity, cycloplegic autorefraction with refinement, and self-reported visual function were assessed in a random, cluster sample of rural secondary school students in Xichang, China. RESULTS: Among the 1892 subjects (97.3% of the consenting children, 84.7% of the total sample), mean age was 14.7 +/- 0.8 years, 51.2% were female, and 26.4% were wearing glasses. The proportion of children with uncorrected, presenting, and corrected visual disability (< or = 6/12 in the better eye) was 41.2%, 19.3%, and 0.5%, respectively. Myopia < -0.5, < -2.0, and < -6.0 D in both eyes was present in 62.3%, 31.1%, and 1.9% of the subjects, respectively. Among the children with visual disability when tested without correction, 98.7% was due to refractive error, while only 53.8% (414/770) of these children had appropriate correction. The girls had significantly (P < 0.001) more presenting visual disability and myopia < -2.0 D than did the boys. More myopic refractive error was associated with worse self-reported visual function (ANOVA trend test, P < 0.001). CONCLUSIONS: Visual disability in this population was common, highly correctable, and frequently uncorrected. The impact of refractive error on self-reported visual function was significant. Strategies and studies to understand and remove barriers to spectacle wear are needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To study spectacle wear among rural Chinese children. METHODS: Visual acuity, refraction, spectacle wear, and visual function were measured. RESULTS: Among 1892 subjects (84.7% of the sample), the mean (SD) age was 14.7 (0.8) years. Among 948 children (50.1%) potentially benefiting from spectacle wear, 368 (38.8%) did not own them. Among 580 children owning spectacles, 17.9% did not wear them at school. Among 476 children wearing spectacles, 25.0% had prescriptions that could not improve their visual acuity to better than 6/12. Therefore, 62.3% (591 of 948) of children needing spectacles did not benefit from appropriate correction. Children not owning and not wearing spectacles had better self-reported visual function but worse visual acuity at initial examination than children wearing spectacles and had a mean (SD) refractive error of -2.06 (1.15) diopter (D) and -2.78 (1.32) D, respectively. Girls (P < .001) and older children (P = .03) were more likely to be wearing their spectacles. A common reason for nonwear (17.0%) was the belief that spectacles weaken the eyes. Among children without spectacles, 79.3% said their families would pay for them (mean, US $15). CONCLUSIONS: Although half of the children could benefit from spectacle wear, 62.3% were not wearing appropriate correction. These children have significant uncorrected refractive errors. There is potential to support programs through spectacle sales.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wearable devices performing advanced bio-signal analysis algorithms are aimed to foster a revolution in healthcare provision of chronic cardiac diseases. In this context, energy efficiency is of paramount importance, as long-term monitoring must be ensured while relying on a tiny power source. Operating at a scaled supply voltage, just above the threshold voltage, effectively helps in saving substantial energy, but it makes circuits, and especially memories, more prone to errors, threatening the correct execution of algorithms. The use of error detection and correction codes may help to protect the entire memory content, however it incurs in large area and energy overheads which may not be compatible with the tight energy budgets of wearable systems. To cope with this challenge, in this paper we propose to limit the overhead of traditional schemes by selectively detecting and correcting errors only in data highly impacting the end-to-end quality of service of ultra-low power wearable electrocardiogram (ECG) devices. This partition adopts the protection of either significant words or significant bits of each data element, according to the application characteristics (statistical properties of the data in the application buffers), and its impact in determining the output. The proposed heterogeneous error protection scheme in real ECG signals allows substantial energy savings (11% in wearable devices) compared to state-of-the-art approaches, like ECC, in which the whole memory is protected against errors. At the same time, it also results in negligible output quality degradation in the evaluated power spectrum analysis application of ECG signals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tese de mestrado integrado em Engenharia Biomédica e Biofísica, apresentada à Universidade de Lisboa, através da Faculdade de Ciências, 2014

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the present study was to determine which augmented sensory modality would best develop subjective error-detection capabilities of learners performing a spatial-temporal task when using a touch screen monitor. Participants were required to learn a 5-digit key-pressing task in a goal time of 2550 ms over 100 acquisition trials on a touch screen. Participants were randomized into 1 of 4 groups: 1) visual-feedback (colour change of button when selected), 2) auditory-feedback (click sound when button was selected), 3) visual-auditory feedback (both colour change and click sound when button was selected), and 4) no-feedback (no colour change or click sound when button was selected). Following each trial, participants were required to provide a subjective estimate regarding their performance time in relation to the actual time it took for them complete the 5-digit sequence. A no-KR retention test was conducted approximately 24-hours after the last completed acquisition trial. Results showed that practicing a timing task on a touch screen augmented with both visual and auditory information may have differentially impacted motor skill acquisition such that removal of one or both sources of augmented feedback did not result in a severe detriment to timing performance or error detection capabilities of the learner. The present study reflects the importance of multimodal augmented feedback conditions to maximize cognitive abilities for developing a stronger motor memory for subjective error-detection and correction capabilities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectif principal: Il n’est pas démontré que les interventions visant à maîtriser voire modérer la médicamentation de patients atteints d’hypertension peuvent améliorer leur gestion de la maladie. Cette revue systématique propose d’évaluer les programmes de gestion contrôlée de la médicamentation pour l’hypertension, en s’appuyant sur la mesure de l’observance des traitements par les patients (CMGM). Design: Revue systématique. Sources de données: MEDLINE, EMBASE, CENTRAL, résumés de conférences internationales sur l’hypertension et bibliographies des articles pertinents. Méthodes: Des essais contrôlés randomisés (ECR) et des études observationnelles (EO) ont été évalués par 2 réviseurs indépendants. L’évaluation de la qualité (de ce matériel) a été réalisée avec l’aide de l’outil de Cochrane de mesure du risque de biais, et a été estimée selon une échelle à quatre niveaux de qualité Une synthèse narrative des données a été effectuée en raison de l'hétérogénéité importante des études. Résultats: 13 études (8 ECR, 5 EO) de 2150 patients hypertendus ont été prises en compte. Parmi elles, 5 études de CMGM avec l’utilisation de dispositifs électroniques comme seule intervention ont relevé une diminution de la tension artérielle (TA), qui pourrait cependant être expliquée par les biais de mesure. L’amélioration à court terme de la TA sous CMGM dans les interventions complexes a été révélée dans 4 études à qualité faible ou modérée. Dans 4 autres études sur les soins intégrés de qualité supérieure, il n'a pas été possible de distinguer l'impact de la composante CMGM, celle-ci pouvant être compromise par des traitements médicamenteux. L’ensemble des études semble par ailleurs montrer qu’un feed-back régulier au médecin traitant peut être un élément essentiel d’efficacité des traitements CMGM, et peut être facilement assuré par une infirmière ou un pharmacien, grâce à des outils de communication appropriés. Conclusions: Aucune preuve convaincante de l'efficacité des traitements CMGM comme technologie de la santé n’a été établie en raison de designs non-optimaux des études identifiées et des ualités méthodologiques insatisfaisantes de celles-ci. Les recherches futures devraient : suivre les normes de qualité approuvées et les recommandations cliniques actuelles pour le traitement de l'hypertension, inclure des groupes spécifiques de patients avec des problèmes d’attachement aux traitements, et considérer les résultats cliniques et économiques de l'organisation de soins ainsi que les observations rapportées par les patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gabion faced re.taining walls are essentially semi rigid structures that can generally accommodate large lateral and vertical movements without excessive structural distress. Because of this inherent feature, they offer technical and economical advantage over the conventional concrete gravity retaining walls. Although they can be constructed either as gravity type or reinforced soil type, this work mainly deals with gabion faced reinforced earth walls as they are more suitable to larger heights. The main focus of the present investigation was the development of a viable plane strain two dimensional non linear finite element analysis code which can predict the stress - strain behaviour of gabion faced retaining walls - both gravity type and reinforced soil type. The gabion facing, backfill soil, In - situ soil and foundation soil were modelled using 20 four noded isoparametric quadrilateral elements. The confinement provided by the gabion boxes was converted into an induced apparent cohesion as per the membrane correction theory proposed by Henkel and Gilbert (1952). The mesh reinforcement was modelled using 20 two noded linear truss elements. The interactions between the soil and the mesh reinforcement as well as the facing and backfill were modelled using 20 four noded zero thickness line interface elements (Desai et al., 1974) by incorporating the nonlinear hyperbolic formulation for the tangential shear stiffness. The well known hyperbolic formulation by Ouncan and Chang (1970) was used for modelling the non - linearity of the soil matrix. The failure of soil matrix, gabion facing and the interfaces were modelled using Mohr - Coulomb failure criterion. The construction stages were also modelled.Experimental investigations were conducted on small scale model walls (both in field as well as in laboratory) to suggest an alternative fill material for the gabion faced retaining walls. The same were also used to validate the finite element programme developed as a part of the study. The studies were conducted using different types of gabion fill materials. The variation was achieved by placing coarse aggregate and quarry dust in different proportions as layers one above the other or they were mixed together in the required proportions. The deformation of the wall face was measured and the behaviour of the walls with the variation of fill materials was analysed. It was seen that 25% of the fill material in gabions can be replaced by a soft material (any locally available material) without affecting the deformation behaviour to large extents. In circumstances where deformation can be allowed to some extents, even up to 50% replacement with soft material can be possible.The developed finite element code was validated using experimental test results and other published results. Encouraged by the close comparison between the theory and experiments, an extensive and systematic parametric study was conducted, in order to gain a closer understanding of the behaviour of the system. Geometric parameters as well as material parameters were varied to understand their effect on the behaviour of the walls. The final phase of the study consisted of developing a simplified method for the design of gabion faced retaining walls. The design was based on the limit state method considering both the stability and deformation criteria. The design parameters were selected for the system and converted to dimensionless parameters. Thus the procedure for fixing the dimensions of the wall was simplified by eliminating the conventional trial and error procedure. Handy design charts were developed which would prove as a hands - on - tool to the design engineers at site. Economic studies were also conducted to prove the cost effectiveness of the structures with respect to the conventional RCC gravity walls and cost prediction models and cost breakdown ratios were proposed. The studies as a whole are expected to contribute substantially to understand the actual behaviour of gabion faced retaining wall systems with particular reference to the lateral deformations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Resumen basado en la publicaci??n

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The relevance of the fragment relaxation energy term and the effect of the basis set superposition error on the geometry of the BF3⋯NH3 and C2H4⋯SO2 van der Waals dimers have been analyzed. Second-order Møller-Plesset perturbation theory calculations with the d95(d,p) basis set have been used to calculate the counterpoise-corrected barrier height for the internal rotations. These barriers have been obtained by relocating the stationary points on the counterpoise-corrected potential energy surface of the processes involved. The fragment relaxation energy can have a large influence on both the intermolecular parameters and barrier height. The counterpoise correction has proved to be important for these systems

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of basis set superposition error (BSSE) on molecular complexes is analyzed. The BSSE causes artificial delocalizations which modify the first order electron density. The mechanism of this effect is assessed for the hydrogen fluoride dimer with several basis sets. The BSSE-corrected first-order electron density is obtained using the chemical Hamiltonian approach versions of the Roothaan and Kohn-Sham equations. The corrected densities are compared to uncorrected densities based on the charge density critical points. Contour difference maps between BSSE-corrected and uncorrected densities on the molecular plane are also plotted to gain insight into the effects of BSSE correction on the electron density

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The basis set superposition error-free second-order MØller-Plesset perturbation theory of intermolecular interactions was studied. The difficulties of the counterpoise (CP) correction in open-shell systems were also discussed. The calculations were performed by a program which was used for testing the new variants of the theory. It was shown that the CP correction for the diabatic surfaces should be preferred to the adiabatic ones