994 resultados para SPIN-RESONANCE
Resumo:
Two integrable quantum spin ladder systems will be introduced associated with the fundamental su(2 \2) solution of the Yang-Baxter equation. The first model is a generalized quantum Ising system with Ising rung interactions. In the second model the addition of extra interactions allows us to impose Heisenberg rung interactions without violating integrability. The existence of a Bethe ansatz solution for both models allows us to investigate the elementary excitations for antiferromagnetic rung couplings. We find that the first model does not show a gap whilst in the second case there is a gap for all positive values of the rung coupling.
Resumo:
Ischaemic preconditioning in rats was studied using MRI. Ischaemic preconditioning was induced, using an intraluminal filament method, by 30 min middle cerebral artery occlusion (MCAO), and imaged 24 h later. The secondary insult of 100 min MCAO was induced 3 days following preconditioning and imaged 24 and 72 h later. Twenty four hours following ischaemic preconditioning most rats showed small sub-cortical hyperintense regions not seen in sham-preconditioned rats. Twenty-four hours and 72 h following the secondary insult preconditioned animals showed significantly smaller lesions (24 h = 112 +/- 31 mm(3), mean +/- standard error; 72 h = 80 +/- 35 mm(3)) which were confined to the striatum, than controls (24 h = 234 +/- 32 mm(3), p = 0.026; 72 h = 275 +/- 37 mm(3), p = 0.003). In addition during Lesion maturation from 24 to 72 h post-secondary MCAO, preconditioned rats displayed an average reduction in lesion size as measured by MRI whereas sham-preconditioned rats displayed increases in lesion size; this is the first report of such differential lesion volume evolution in cerebral ischaemic preconditioning. Copyright (C) 2001 John Wiley & Sons, Ltd.
Resumo:
The nuclear magnetic resonance (NMR) spin-spin relaxation time (T-2) is related to the radiation-dependent concentration of polymer formed in polymer gel dosimeters manufactured from monomers in an aqueous gelatin matrix. Changes in T-2 with time post-irradiation have been reported in the literature but their nature is not fully understood. We investigated those changes with time after irradiation using FT-Raman spectroscopy and the precise determination of T-2 at high magnetic field in a polymer gel dosimeter, A model of fast exchange of magnetization taking into account ongoing gelation and strengthening of the gelatin matrix as well as the polymerization of the monomers with time is presented. Published data on the changes of T-2 in gelatin gels as a function of post-manufacture time are used and fitted closely by the model presented. The same set of parameters characterizing the variations of T-2 in gelatin gels and the increasing concentration of polymer determined from Fr-Raman spectroscopy are used successfully in the modelling of irradiated polymer gel dosimeters. Minimal variations in T-2 in an irradiated PAG dosimeter are observed after 13 h.
Resumo:
Little is known of the neural mechanisms of marsupial olfaction. However, functional magnetic resonance imaging (fMRI) has made it possible to visualize dynamic brain function in mammals without invasion. In this study, central processing of urinary pheromones was investigated in the brown antechinus, Antechinus stuartii, using fMRI. Images were obtained from 18 subjects (11 males, 7 females) in response to conspecific urinary olfactory stimuli. Significant indiscriminate activation occurred in the accessory olfactory bulb, entorhinal, frontal, and parietal cortices in response to both male and female urine. The paraventricular nucleus of hypothalamus, ventrolateral thalamic nucleus, and medial preoptic area were only activated in response to male urine. Results of this MRI study indicate that projections of accessory olfactory system are activated by chemo-sensory cues. Furthermore, it appears that, based on these experiments, urinary pheromones may act on the hypothalamo-pituitary-adrenocortical axis via the paraventricular nucleus of the hypothalamus and may play an important role in the unique life history pattern of A. stuartii. Finally, this study has demonstrated that fMRI may be a powerful tool for investigations of olfactory processes in mammals.
Resumo:
Off-resonance RF pre-saturation was used to obtain contrast in MRI images of polymer gel dosimeters irradiated to doses up to 50 Gy. Two different polymer gel dosimeters composed of 2-hydroxyethyl-acryl ate or methacrylic acid monomers mixed with N, N'-methylene-bisacrylamide (BIS), dispersed in an aqueous gelatin matrix were evaluated. Radiation-induced polymerization of the co-monomers generates a fast-relaxing insoluble polymer. Saturation of the polymer using off-resonance Gaussian RF pulses prior to a spin-echo read-out with a short echo time leads to contrast that is dependent on the absorbed dose. This contrast is attributed to magnetization transfer (MT) between free water and the polymer, and direct saturation of water was found to be negligible under the prevailing experimental conditions. The usefulness of MT imaging was assessed by computing the dose resolution obtained with this technique. We found a low value of dose resolution over a wide range of doses could be obtained with a single experiment. This is an advantage over multiple spin echo (MSE) experiments using a single echo spacing where an optimal dose resolution is achieved over only very limited ranges of doses. The results suggest MT imaging protocols may be developed into a useful tool for polymer gel dosimetry.
Resumo:
The performance of three different techniques for determining proton rotating frame relaxation rates (T1pH) in charred and uncharred woods is compared. The variable contact time (VCT) experiment is shown to over-estimate T1pH, particularly for the charred samples, due to the presence of slowly cross-polarizing C-13 nuclei. The variable spin (VSL) or delayed contact experiment is shown to overcome these problems; however, care is needed in the analysis to ensure rapidly relaxing components are not overlooked. T1pH is shown to be non-uniform for both charred and uncharred wood samples; a rapidly relaxing component (T1pH = 0.46-1.07 ms) and a slowly relaxing component (T1pH = 3.58-7.49) is detected in each sample. T1pH for each component generally decreases with heating temperature (degree of charring) and the proportion of rapidly relaxing component increases. Direct T1pH determination (via H-1 detection) shows that all samples contain an even faster relaxing component (0.09-0.24 ms) that is virtually undetectable by the indirect (VCT and VSL) techniques. A new method for correcting for T1pH signal losses in spin counting experiments is developed to deal with the rapidly relaxing component detected in the VSL experiment. Implementation of this correction increased the proportion of potential C-13 CPMAS NMR signal that can be accounted for by up to 50% for the charred samples. An even greater proportion of potential signal can be accounted for if the very rapidly relaxing component detected in the direct T1pH determination is included; however, it must be kept in mind that this experiment also detects H-1 pools which may not be involved in H-1-C-13 cross-polarization. (C) 2002 Elsevier Science (USA).
Resumo:
It has recently been stated that the parametrization of the time variables in the one-dimensional (I-D) mixing-frequency electron spin-echo envelope modulation (MIF-ESEEM) experiment is incorrect and hence the wrong frequencies for correlated nuclear transitions are predicted. This paper is a direct response to such a claim, its purpose being to show that the parametrization in land 2-D MIF-ESEEM experiments possesses the same form as that used in other 4-pulse incrementation schemes and predicts the same correlation frequencies. We show that the parametrization represents a shearing transformation of the 2-D time-domain and relate the resulting frequency domain spectrum to the HYSCORE spectrum in terms of a skew-projection. It is emphasized that the parametrization of the time-domain variables may be chosen arbitrarily and affects neither the computation of the correct nuclear frequencies nor the resulting resolution. The usefulness or otherwise of the MIF parameters \gamma\ > 1 is addressed, together with the validity of the original claims of the authors with respect to resolution enhancement in cases of purely homogeneous and inhomogeneous broadening. Numerical simulations are provided to illustrate the main points.
Resumo:
The (2,3)J(CH) dependence on dihedral angle (theta H-C-C-X) for cyclopentane derivatives was investigated. We observed that the combined use of experimentally obtained (2,3)J(CH) values and the theoretically determined dihedral angles between the corresponding nuclei can be used to infer the relative stereochemistry of the ring substituents in cyclopentane derivatives. There is a good correlation between the magnitude of (3)J(CH) and the dihedral angle between the hydrogen and the coupled carbon (R-2 = 0.88). Copyright (C) 2008 John Wiley & Sons, Ltd.
Resumo:
Objective: To determine the cost effectiveness of a magnetic resonance imaging scan (MRI) within 5 days of injury compared with the usual management of occult scaphoid fracture. Methods: All patients with suspected scaphoid fractures in five hospitals were invited to participate in a randomised controlled trial of usual treatment with or without an MRI scan. Healthcare costs were compared, and a cost effectiveness analysis of the use of MRI in this scenario was performed. Results: Twenty eight of the 37 patients identified were randomised: 17 in the control group, 11 in the MRI group. The groups were similar at baseline and follow up in terms of number of scaphoid fractures, other injuries, pain, and function. Of the patients without fracture, the MRI group had significantly fewer days immobilised: a median of 3.0 (interquartile range 3.0-3.0) v 10.0 (7-12) in the control group (p = 0.006). The MRI group used fewer healthcare units (median 3.0, interquartile range 2.0-4.25) than the control group (5.0, 3.0-6.5) (p = 0.03 for the difference). However, the median cost of health care in the MRI group ($594.35 AUD, $551.35-667.23) was slightly higher than in the control group ($428.15, $124.40-702.65) (p = 0.19 for the difference). The mean incremental cost effectiveness ratio derived from this simulation was that MRI costs $44.37 per day saved from unnecessary immobilisation (95% confidence interval $4.29 to $101.02). An illustrative willingness to pay was calculated using a combination of the trials measure of the subjects' individual productivity losses and the average daily earnings. Conclusions: Use of MRI in the management of occult scaphoid fracture reduces the number of days of unnecessary immobilisation and use of healthcare units. Healthcare costs increased non-significantly in relation to the use of MRI in this setting. However, when productivity losses are considered, MRI may be considered cost effective, depending on the individual case.
Magnetic Investigation of CoFe(2)O(4) Nanoparticles Supported in Biocompatible Polymeric Microsphere
Resumo:
Magnetic investigation of spinel ferrite nanoparticles dispersed in biocompatible polymeric microspheres is reported in this study. X-ray diffraction data analysis confirms the presence of nanosized CoFe(2)O(4) particles (mean size of similar to 8 nm). This finding is corroborated by transmission electron microscopy micrographs. Magnetization isotherms suggest a spin disorder likely occurring at the nanoparticle`s surface. The saturation magnetization value is used to estimate particle concentration of 1.6 x 10(18) cm(-3) dispersed in the polymeric template. A T(1/2) dependence of the coercive field is determined in the low-temperature region (T < 30 K). The model of non-interacting mono-domains is used to estimate an effective magnetic anisotropy of K(eff) = 0.6 x 10(5) J/m(3). The K(eff) value we found is lower than the value reported for spherically-shaped CoFe(2)O(4) nanoparticles, though consistent with the low coercive field observed in the investigated sample.
Resumo:
N,N-dimethyl-pyrrolidinium iodide has been investigated using differential scanning calorimetry, nuclear magnetic resonance (NMR) spectroscopy, second moment calculations, and impedance spectroscopy. This pyrrolidinium salt exhibits two solid-solid phase transitions, one at 373 K having an entropy change, Delta S, of 38 J mol(-1) K-1 and one at 478 K having Delta S of 5.7 J mol(-1) K-1. The second moment calculations relate the lower temperature transition to a homogenization of the sample in terms of the mobility of the cations, while the high temperature phase transition is within the temperature region of isotropic tumbling of the cations. At higher temperatures a further decrease in the H-1 NMR linewidth is observed which is suggested to be due to diffusion of the cations. (C) 2005 American Institute of Physics.
Resumo:
A functional magnetic resonance imaging mental rotation paradigm was used to investigate the patterns of activation of fronto-parietal brain areas in male adolescents with attention-deficit hyperactivity disorder, combined type (ADHD-CT) compared with age-, gender-, handedness- and performance IQ-matched healthy controls. The ADHD-CT group had (a) decreased activation of the 'action-attentional' system (including Brodmann's areas (BA) 46, 39,40) and the superior parietal (BA7) and middle frontal (BA10) areas and (b) increased activation of the posterior midline attentional system. These different neuroactivation patterns indicate widespread frontal, striatal and parietal dysfunction in adolescents with ADHD-CT. Declaration of interest None.
Resumo:
Objectives We sought to determine whether the quantitative assessment of myocardial fibrosis (MF), either by histopathology or by contrast-enhanced magnetic resonance imaging (ce-MRI), could help predict long-term survival after aortic valve replacement. Background Severe aortic valve disease is characterized by progressive accumulation of interstitial MF. Methods Fifty-four patients scheduled to undergo aortic valve replacement were examined by ce-MRI. Delayed-enhanced images were used for the quantitative assessment of MF. In addition, interstitial MF was quantified by histological analysis of myocardial samples obtained during open-heart surgery and stained with picrosirius red. The ce-MRI study was repeated 27 +/- 22 months after surgery to assess left ventricular functional improvement, and all patients were followed for 52 +/- 17 months to evaluate long-term survival. Results There was a good correlation between the amount of MF measured by histopathology and by ce-MRI (r = 0.69, p < 0.001). In addition, the amount of MF demonstrated a significant inverse correlation with the degree of left ventricular functional improvement after surgery (r = -0.42, p = 0.04 for histopathology; r = -0.47, p = 0.02 for ce-MRI). Kaplan-Meier analyses revealed that higher degrees of MF accumulation were associated with worse long-term survival (chi-square = 6.32, p = 0.01 for histopathology; chi-square = 5.85, p = 0.02 for ce-MRI). On multivariate Cox regression analyses, patient age and the amount of MF were found to be independent predictors of all-cause mortality. Conclusions The amount of MF, either by histopathology or by ce-MRI, is associated with the degree of left ventricular functional improvement and all-cause mortality late after aortic valve replacement in patients with severe aortic valve disease. (J Am Coll Cardiol 2010; 56: 278-87) (c) 2010 by the American College of Cardiology Foundation
Resumo:
Purpose: To evaluate the risk of geographic miss associated with the classic four-field ""box"" irradiation technique and to define the variables that predict this risk. Materials and Methods: The study population consisted of 80 patients with uterine cervix cancer seen between 2001 and 2006. Median age was 55 years (23-82 years), and 72 (90%) presented with squamous cell carcinoma. Most patients (68.7%) presented with locally advanced disease (IIb or more). Magnetic resonance imaging findings from before treatment were compared with findings from simulation of the conventional four-field ""box"" technique done with rectal contrast. Study variables included tumor volume; involvement of vagina, parametrium, bladder, or rectum; posterior displacement of the anterior rectal wall; and tumor anteroposterior diameter (APD). Margins were considered adequate when the target volume (primary tumor extension, whole uterine body, and parametrium) was included within the field limits and were at least 1 cm in width. Results: Field limits were inadequate in 45 (56%) patients: 29 (36%) patients at the anterior and 28 (35%) at the posterior border of the lateral fields. Of these, 12 patients had both anterior and posterior miss, and this risk was observed in all stages of the disease (p = 0.076). Posterior displacement of the anterior rectal wall beyond S2-S3 was significantly correlated with the risk of geographic miss (p = 0.043). Larger tumors (APD 6 cm or above and volume above 50 cm(3)) were also significantly correlated with this risk (p = 0.004 and p = 0.046, respectively). Conclusions: Posterior displacement of the anterior rectal wall, tumor APD, and volume can be used as guidance in evaluating the risk of geographic miss. (C) 2009 Elsevier Inc.