986 resultados para Pulsed Magnetic-fields


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This thesis investigates phenomena of vortex dynamics in type II superconductors depending on the dimensionality of the flux-line system and the strength of the driving force. In the low dissipative regime of Bi_2Sr_2CaCu_2O_{8+delta} (BSCCO) the influence of oxygen stoichiometry on flux-line tension was examined. An entanglement crossover of the vortex system at low magnetic fields was identified and a comprehensive B-T phase diagram of solid and fluid phases derived.In YBa_2Cu_3O_7 (YBCO) extremely long (>100 mm) high-quality measurement bridges allowed to extend the electric-field window in transport measurements by up to three orders of magnitude. Complementing analyses of the data conclusively produced dynamic exponents of the glass transition z~9 considerably higher than theoretically predicted and previously reported. In high-dissipative measurements a voltage instability appearing in the current-voltage characteristics of type II superconductors was observed for the first time in BSCCO and shown to result from a Larkin-Ovchinnikov flux-flow vortex instability under the influence of quasi-particle heating. However, in an analogous investigation of YBCO the instability was found to appear only in the temperature and magnetic-field regime of the vortex-glass state. Rapid-pulse measurements fully confirmed this correlation of vortex glass and instability in YBCO and revealed a constant rise time (~µs).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Das Detektorsystem des Spektrometers Ader Drei-Spektrometer-Anlage am MainzerElektronenbeschleuniger MAMI wurde im Rahmen dieser Arbeitum ein Fokalebenen-Proton-Polarimeter (FPP) ergänzt.Dazu wurden zwei Horizontale Doppeldriftkammern entworfenund zusammen mit einem Kohlenstoffanalysator hinter derFokalebene des Spektrometers aufgebaut.Zur Berechnung der Spin-Präzession in den inhomogenenMagnetfeldern des Spektrometers wurde das Programm QSPINerstellt und damit eine Spin-Transfer-Matrix (STM) erzeugt,mit der über eine Fitprozedur die Polarisationskomponentender Protonen in der Streuebene an die im FPP gemessenenangepaßt werden können.Mit elastischen Elektron-Proton-Streuexperimenten wurdenfalsche Asymmetrien im FPP untersucht, die berechnete STMbestätigt, die inklusive Proton-Kohlenstoff-Analysierstärkeauf einen größeren Streuwinkelbereich erweitert und dasVerhältnis zwischen dem elektrischen und dem magnetischenSachs-Formfaktor des Protons gemessen.Zur Untersuchung der Coulomb-Quadrupol-Übergangsamplitudebei der Anregung des Nukleons zur Delta(1232)-Resonanzwurden in einem Pion-Elektroproduktions-Experiment am Protonmit dem FPP die Komponenten der Polarisation derRückstoßprotonen in paralleler Kinematik gemessen.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study is to evaluate the effects of the pulsed electromagnetic fields (PEMFS) on pain relief and functional capacity of dogs with osteoarthritis by which a single centre study prospective clinical trial. PEMFs are non ionized, athermic and time varying electromagnetic fields that has been successfully used for the treatment of osteoarthritis in human thanks to their chondroprotective, antinflammatory and analgesic property. 20 dogs were treated with PEMFs , 3 times per week for a total of 20 sessions.We found beneficial effects on pain relief and lameness in the absence of adverse effect. The decrease of pain impacted positively on the health-dogs related quality of life and the grade of satisfaction of their owner was very high. The benefits were obvious at half therapy and lasted for a medium long time. This is the first published report concerning PEMFs treatment on canine osteoarthtitis. The result of this study proves that PEMFs is a non –invasive remedy, lacking in adverse effect , easy to employ and useful for controlling pain and inflammation associated with osteoarthritis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Die vorliegende Arbeit untersucht die Möglichkeiten und Limitierungen der MR-Lungenbildgebung mit hyperpolarisiertem 3-He bei gegenüber üblichen Magnetfeldstärken reduzierten magnetischen Führungsfeldern. Dabei werden insbesondere auch die funktionellen Bildgebungstechniken (dynamische Bildgebung, diffusionsgewichtete Bildgebung und Bestimmung des Sauerstoff-Partialdrucks) berücksichtigt. Experimentell geschieht dies durch in vivo Messungen an einem 0.1 T-Ganzkörpertomographen. Zur systematischen Untersuchung der MR-Bildgebung unter dem Einfluss diffundierender Kontrastmittel werden analytische Simulationen, Monte-Carlo-Studien und Referenzexperimente durchgeführt. Hier wird das Augenmerk besonders auf den Einfluss von Diffusions- und Suszeptibilitätsartefakten auf die morphologische und die diffusionsgewichtete Bildgebung gerichtet. Die Entwicklung und der Vergleich verschiedener Konzepte zur Erzeugung von MR-Führungsmagnetfeldern führt zur Erfindung eines neuartigen Prinzips zur weiträumigen Homogenisierung von Magnetfeldern. Die Umsetzung dieses Prinzips erfolgt in Form eines besonders kompakten Transportbehälters für kernspinpolarisierte Edelgase. Die Arbeit beinhaltet eine ausführliche Diskussion der MR-Bildgebungstechnik in Theorie und Praxis, um die Anknüpfungspunkte an die angestellten Untersuchungen herauszuarbeiten. Teile dieser Studien wurden von der Europäischen Raumfahrtorganisation ESA finanziert (Contract No.15308/01/NL/PA).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The consumer demand for natural, minimally processed, fresh like and functional food has lead to an increasing interest in emerging technologies. The aim of this PhD project was to study three innovative food processing technologies currently used in the food sector. Ultrasound-assisted freezing, vacuum impregnation and pulsed electric field have been investigated through laboratory scale systems and semi-industrial pilot plants. Furthermore, analytical and sensory techniques have been developed to evaluate the quality of food and vegetable matrix obtained by traditional and emerging processes. Ultrasound was found to be a valuable technique to improve the freezing process of potatoes, anticipating the beginning of the nucleation process, mainly when applied during the supercooling phase. A study of the effects of pulsed electric fields on phenol and enzymatic profile of melon juice has been realized and the statistical treatment of data was carried out through a response surface method. Next, flavour enrichment of apple sticks has been realized applying different techniques, as atmospheric, vacuum, ultrasound technologies and their combinations. The second section of the thesis deals with the development of analytical methods for the discrimination and quantification of phenol compounds in vegetable matrix, as chestnut bark extracts and olive mill waste water. The management of waste disposal in mill sector has been approached with the aim of reducing the amount of waste, and at the same time recovering valuable by-products, to be used in different industrial sectors. Finally, the sensory analysis of boiled potatoes has been carried out through the development of a quantitative descriptive procedure for the study of Italian and Mexican potato varieties. An update on flavour development in fresh and cooked potatoes has been realized and a sensory glossary, including general and specific definitions related to organic products, used in the European project Ecropolis, has been drafted.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Diverse tecniche di ingegneria tessutale sono state sviluppate per promuovere la riparazione delle lesioni della cartilagine articolare. Nonostante i buoni risultati clinici a breve termine, il tessuto rigenerato fallisce nel tempo poiché non possiede le caratteristiche meccaniche e funzionali della cartilagine articolare nativa. La stimolazione con campi elettromagnetici pulsati (CEMP) rappresenta un approccio terapeutico innovativo. I CEMP aumentano l’attività anabolica dei condrociti con conseguente incremento della sintesi della matrice, e limitano l’effetto catabolico delle citochine pro-infiammatorie riducendo la degradazione della cartilagine nel microambiente articolare. I CEMP agiscono mediante l’up-regolazione dei recettori adenosinici A2A potenziando il loro affetto anti-infiammatorio. Lo scopo di questo studio è stato quello di valutare l’effetto della stimolazione con CEMP sulla guarigione di difetti osteocondrali in un modello sperimentale nel coniglio. Un difetto osteocondrale del diametro di 4mm è stato eseguito nel condilo femorale mediale di entrambe le ginocchia di 20 conigli. A destra la lesione è stata lasciata a guarigione spontanea mentre a sinistra e stata trattata mediante inserimento di scaffold collagenico o trapianto di cellule mesenchimali midollari sul medesimo scaffold precedentemente prelevate dalla cresta iliaca. In base al trattamento eseguito 10 animali sono stati stimolati con CEMP 4 ore/die per 40 giorni mentre altri 10 hanno ricevuto stimolatori placebo. Dopo il sacrificio a 40 giorni, sono state eseguite analisi istologiche mediante un punteggio di O’Driscoll modificato. Confrontando le lesioni lasciate a guarigione spontanea, la stimolazione con CEMP ha migliorato significativamente il punteggio (p=0.021). Lo stesso risultato si è osservato nel confronto tra lesioni trattate mediante trapianto di cellule mesenchimali midollari (p=0.032). Nessuna differenza è stata osservata tra animali stimolati e placebo quando la lesione è stata trattata con il solo scaffold (p=0.413). La stimolazione con CEMP è risultata efficace nel promuovere la guarigione di difetti osteocartilaginei in associazione a tecniche chirurgiche di ingegneria tessutale.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A two-dimensional model to analyze the distribution of magnetic fields in the airgap of a PM electrical machines is studied. A numerical algorithm for non-linear magnetic analysis of multiphase surface-mounted PM machines with semi-closed slots is developed, based on the equivalent magnetic circuit method. By using a modular structure geometry, whose the basic element can be duplicated, it allows to design whatever typology of windings distribution. In comparison to a FEA, permits a reduction in computing time and to directly changing the values of the parameters in a user interface, without re-designing the model. Output torque and radial forces acting on the moving part of the machine can be calculated. In addition, an analytical model for radial forces calculation in multiphase bearingless Surface-Mounted Permanent Magnet Synchronous Motors (SPMSM) is presented. It allows to predict amplitude and direction of the force, depending on the values of torque current, of levitation current and of rotor position. It is based on the space vectors method, letting the analysis of the machine also during transients. The calculations are conducted by developing the analytical functions in Fourier series, taking all the possible interactions between stator and rotor mmf harmonic components into account and allowing to analyze the effects of electrical and geometrical quantities of the machine, being parametrized. The model is implemented in the design of a control system for bearingless machines, as an accurate electromagnetic model integrated in a three-dimensional mechanical model, where one end of the motor shaft is constrained to simulate the presence of a mechanical bearing, while the other is free, only supported by the radial forces developed in the interactions between magnetic fields, to realize a bearingless system with three degrees of freedom. The complete model represents the design of the experimental system to be realized in the laboratory.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Hydrogels are used in a variety of applications in daily life, such as super absorbers, contact lenses and in drug delivery. Functional hydrogels that allow the incorporation of additional functionalities have enormous potential for future development. The properties of such hydrogels can be diversified by introducing responsiveness to external stimuli. These crosslinked polymers are known to respond to changes in temperature, pH and pressure, as well as chemical and electrical stimuli, magnetic fields and irradiation. From this responsive behavior possible applications arise in many fields like drug delivery, tissue engineering, purification and implementation as actuators, biosensors or for medical coatings. However, their interaction with biomaterial and way of functioning are yet not fully understood. Therefore, thorough investigations regarding their optical, mechanical and chemical nature have to be conducted. A UV-crosslinkable polymer, consisting of N-isopropylacrylamide, methacrylic acid and the UV-crosslinker 4-benzoylphenyl methacrylate was synthesized. Its composition, determined by a comprehensive NMR study, is equivalent to the composition of the monomer mixture. The chemical characteristics were preserved during the subsequently formation of hydrogel films by photo-crosslinking as proved by XPS. For the optical characterization, e.g. the degree of swelling of very thin films, the spectroscopy of coupled long range surface plasmons is introduced. Thicker films, able to guide light waves were analyzed with combined surface plasmon and optical waveguide mode spectroscopy (SPR/OWS). The evaluation of the data was facilitated by the reverse Wentzel-Kramers-Brillouin (WKB) approximation. The meshsize and proper motion of the surface anchored hydrogels were investigated by fluorescence correlation spectroscopy (FCS), micro photon correlation spectroscopy (µPCS) and SPR/OWS. The studied gels exhibit a meshsize that allowed for the diffusion of small biomolecules inside their network. For future enhancement of probing diffusants, a dye that enables FRET in FCS was immobilized in the gel and the diffusion of gold-nanoparticles embedded in the polymer solution was studied by PCS. These properties can be conveniently tuned by the crosslinking density, which depends on the irradiation dose. Additionally, protocols and components for polymer analogous reactions based on active ester chemistry of the hydrogel were developed. Based on these syntheses and investigations, the hydrogel films are applied in the fields of medical coatings as well as in biosensing as matrix and biomimetic cushion. Their non-adhesive properties were proved in cell experiments, SPR/OWS and ToF-SIMS studies. The functionality and non-fouling property of the prepared hydrogels allowed for adaption to the needs of the respective application.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In case of violation of CPT- and Lorentz Symmetry, the minimal Standard Model Extension (SME) of Kostelecky and coworkers predicts sidereal modulations of atomic transition frequencies as the Earth rotates relative to a Lorentz-violating background field. One method to search for these modulations is the so-called clock-comparison experiment, where the frequencies of co-located clocks are compared as they rotate with respect to the fixed stars. In this work an experiment is presented where polarized 3He and 129Xe gas samples in a glass cell serve as clocks, whose nuclear spin precession frequencies are detected with the help of highly sensitive SQUID sensors inside a magnetically shielded room. The unique feature of this experiment is the fact that the spins are precessing freely, with transverse relaxation times of up to 4.4 h for 129Xe and 14.1 h for 3He. To be sensitive to Lorentz-violating effects, the influence of external magnetic fields is canceled via the weighted difference of the 3He and 129Xe frequencies or phases. The Lorentz-violating SME parameters for the neutron are determined out of a fit on the phase difference data of 7 spin precession measurements of 12 to 16 hours length. The result of the fit gives an upper limit for the equatorial component of the neutron parameter b_n of 3.7×10^(−32) GeV at the 95% confidence level. This value is not limited by the signal-to-noise ratio, but by the strong correlations between the fit parameters. To reduce the correlations and therewith improve the sensitivity of future experiments, it will be necessary to change the time structure of the weighted phase difference, which can be realized by increasing the 129Xe relaxation time.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this thesis, we investigate mixtures of quantum degenerate Bose and Fermi gases of neutral atoms in threedimensional optical lattices. Feshbach resonances allow to control interspecies interactions in these systems precisely, by preparing suitable combinations of internal atomic states and applying external magnetic fields. This way, the system behaviour can be tuned continuously from mutual transparency to strongly interacting correlated phases, up to the stability boundary.rnThe starting point for these investigations is the spin-polarized fermionic band insulator. The properties of this non-interacting system are fully determined by the Pauli exclusion principle for the occupation of states in the lattice. A striking demonstration of the latter can be found in the antibunching of the density-density correlation of atoms released from the lattice. If bosonic atoms are added to this system, isolated heteronuclear molecules can be formed on the lattice sites via radio-frequency stimulation. The efficiency of this process hints at a modification of the atom number distribution over the lattice caused by interspecies interaction.rnIn the following, we investigate systems with tunable interspecies interaction. To this end, a method is developed which allows to assess the various contributions to the system Hamiltonian both qualitatively and quantitatively by following the quantum phase diffusion of the bosonic matter wave.rnBesides a modification of occupation number statistics, these measurements show a significant renormalization of the bosonic Hubbard parameters. The final part of the thesis considers the implications of this renormalization effect on the many particle physics in the mixture. Here, we demonstrate how the quantum phase transition from a bosonic superfluid to a Mott insulator state is shifted towards considerably shallower lattices due to renormalization.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ion traps have been established as a powerful tool for ion cooling and laser spectroscopy experiments since a long time ago. SpecTrap, one of the precision experiments associated to the HITRAP facility at GSI, is implementing a Penning trap for studies of large bunches of externally produced highly charged ions. The extremely strong electric and magnetic fields that exist around the nuclei of heavy elements drastically change their electronic properties, such as energy level spacings and radiative lifetimes. The electrons can therefore serve as sensitive probes for nuclear properties such as size, magnetic moment and spatial distribution of charge and magnetization. The energies of forbidden fine and hyperfine structure transitions in such ions strongly depend on the nuclear charge and shift from the microwave domain into the optical domain. Thus, they become accessible for laser spectroscopy and its potentially high accuracy. A number of such measurements has been performed in storage rings and electron beam ion traps and yielded results with relative accuracies in the 10

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Magnetic memories are a backbone of today's digital data storage technology, where the digital information is stored as the magnetic configuration of nanostructured ferromagnetic bits. Currently, the writing of the digital information on the magnetic memory is carried out with the help of magnetic fields. This approach, while viable, is not optimal due to its intrinsically high energy consumption and relatively poor scalability. For this reason, the research for different mechanisms that can be used to manipulate the magnetic configuration of a material is of interest. In this thesis, the control of the magnetization of different nanostructured materials with field-free mechanisms is investigated. The magnetic configuration of these nanostructured materials was imaged directly with high resolution x-ray magnetic microscopy. rnFirst of all, the control of the magnetic configuration of nanostructured ferromagnetic Heusler compounds by fabricating nanostructures with different geometries was analyzed. Here, it was observed that the magnetic configuration of the nanostructured elements is given by the competition of magneto-crystalline and shape anisotropy. By fabricating elements with different geometries, we could alter the point where these two effects equilibrate, allowing for the possibility to tailor the magnetic configuration of these nanostructured elements to the required necessities.rnThen, the control of the magnetic configuration of Ni nanostructures fabricated on top of a piezoelectric material with the magneto-elastic effect (i.e. by applying a piezoelectric strain to the Ni nanostructures) was investigated. Here, the magneto-elastic coupling effect gives rise to an additional anisotropy contribution, proportional to the strain applied to the magnetic material. For this system, a reproducible and reversible control of the magnetic configuration of the nanostructured Ni elements with the application of an electric field across the piezoelectric material was achieved.rnFinally, the control of the magnetic configuration of La0.7Sr0.3MnO3 (LSMO) nanostructures with spin-polarized currents was studied. Here, the spin-transfer torque effect was employed to achieve the displacement of magnetic domain walls in the LSMO nanostructures. A high spin-transfer torque efficiency was observed for LSMO at low temperatures, and a Joule-heating induced hopping of the magnetic domain walls was observed at room temperatures, allowing for the analysis of the energetics of the domain walls in LSMO.rnThe results presented in this thesis give thus an overview on the different field-free approaches that can be used to manipulate and tailor the magnetization configuration of a nanostructured material to the various technological requirements, opening up novel interesting possibilities for these materials.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Der Spin Seebeck Effekt repräsentiert einen neuartigen Spin kalorischen Effekt mit vorteilhaften und aussichtsreichen Eigenschaften für Anwendungen in den Gebieten der Spintronik und Thermoelektrik.rnIn dieser Arbeit präsentieren wir eine umfangreiche Untersuchung des Spin Seebeck Effekts in isolierenden, magnetischen Granaten und geben Antworten zum kontrovers diskutierten Ursprung des Effekts. Um dieses Ziel zu erreichen, haben wir die Abhängigkeit des Spin Seebeck Effekts von der Dicke des Ferromagneten, der Temperatur, der Stärke des magnetisches Feldes, der Grenzflächen und des Detektormaterials, sowie Kombinationen dieser Parameter gemessen. Im Zuge dessen haben wir das Wachstum der untersuchten magnetischen Granate optimiert und eine umfassende Analyse der strukturellen und magnetischen Parameter durchgeführt, um Einflüsse der Probenqualität auszuschließen. Des Weiteren zeigte eine Untersuchung des magnetoresistiven Effekts, welcher als mögliche Ursache des Effekts galt, in Kombination mit einer Studie des Messaufbaus, dass parasitäre Einflüsse auf das Messergebnis ausgeschlossen werden können. Unsere Ergebnisse zeigen, dass der Spin Seebeck Effekt mit zunehmender Dicke des Ferromagneten eine Sättigung des Signals aufweist. Diese hängt zudem von der Temperatur ab, da mit abnehmender Temperatur die Sättigung erst bei dickeren Filmen auftritt. Außerdem fanden unsere Messungen ein Maximum des Spin Seebeck Effekts für Temperaturen unterhalb der Raumtemperatur, welcher sowohl von der Dicke des Materials als auch der Magnetfeldstärke und dem Detektormaterial beeinflusst wird. In Messungen bei hohen magnetischen Feldstärken beobachteten wir eine Unterdrückung des Messsignals, dessen Ursache mithilfe von Simulationen auf den magnonischen Ursprung des Spin Seebeck Effekts zurückgeführt werden kann. Dies unterstreicht, dass der Effekt auf vom Ferromagneten emittierten Magnonen basiert. Im letzten Abschnitt dieser Arbeit präsentieren wir Messungen in einem bislang nicht untersuchten ferrimagnetischen Material, welche zwei Vorzeichenwechsel des Spin Seebeck Effekts als Funktion der Temperatur aufzeigen. Dieses bisher unbekannte Signalverhalten betont, dass der Effekt aus einem komplexen Zusammenspiel der magnonischen Moden resultiert und zusätzlich vom Detektormaterial abhängt.rnSomit tragen unsere Ergebnisse und Beobachtungen im hohen Maße zur Beantwortung der Frage nach dem Ursprungs des Spin Seebeck Effekts bei und zeigen neuartige bisher nicht beobachtete Effekte, welche ein neues Kapitel für das Gebiet der Spin Kaloritronik eröffnen.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Diese Arbeit beschreibt die Entwicklung, Konstruktion und Untersuchung eines Magnetometers zur exakten und präzisen Messung schwacher Magnetfelder. Diese Art von Magnetometer eignet sich zur Anwendung in physikalischen hochpräzisions Experimenten wie zum Beispiel der Suche nach dem elektrischen Dipolmomentrndes Neutrons. Die Messmethode beruht auf der gleichzeitigen Detektion der freien Spin Präzession Kern-Spin polarisierten 3He Gases durch mehrere optisch gepumpte Cäsium Magnetometer. Es wird gezeigt, dass Cäsium Magnetometer eine zuverlässige und vielseitige Methode zur Messung der 3He Larmor Frequenz und eine komfortable Alternative zur Benutzung von SQUIDs für diesen Zweck darstellen. Ein Prototyp dieses Magnetometers wurde gebaut und seine Funktion in der magnetisch abgeschirmten Messkabine der Physikalisch Technischen Bundesanstalt untersucht. Die Sensitivität des Magnetometers in Abhängigkeitrnvon der Messdauer wurde experimentell untersucht. Es wird gezeigt, dass für kurze Messperioden (< 500s) Cramér-Rao limitierte Messungen möglich sind während die Sensitivität bei längeren Messungen durch die Stabilität des angelegten Magnetfeldes limitiert ist. Messungen eines 1 muT Magnetfeldes mit einer relative Genauigkeit von besser als 5x10^(-8) in 100s werden präsentiert. Es wird gezeigt, dass die Messgenauigkeit des Magnetometers durch die Zahl der zur Detektion der 3He Spin Präzession eingesetzten Cäsium Magnetometer skaliert werden kann. Prinzipiell ist dadurch eine Anpassung der Messgenauigkeit an jegliche experimentellen Bedürfnisse möglich. Es wird eine gradiometrische Messmethode vorgestellt, die es erlaubt den Einfluss periodischerrnmagnetischer Störungen auf dieMessung zu unterdrücken. Der Zusammenhang zwischen der Sensitivität des kombinierten Magnetometers und den Betriebsparametern der Cäsium Magnetometer die zur Spin Detektion verwendet werden wird theoretisch untersucht und anwendungsspezifische Vor- und Nachteile verschiedener Betriebsartenwerden diskutiert. Diese Zusammenhänge werden in einer Formel zusammengefasst die es erlaubt, die erwartete Sensitivität des Magnetometers zu berechnen. Diese Vorhersagen befinden sich in perfekter Übereinstimmung mit den experimentellen Daten. Die intrinsische Sensitivität des Magnetometer Prototyps wird auf Basis dieser Formel theoretisch bestimmt. Ausserdem wird die erwartete Sensitivität für die Anwendung im Rahmen des Experiments der nächsten Generation zur Bestimmung des elektrischenrnDipolmoments des Neutrons am Paul Scherrer Institut abgeschätzt. Des weiteren wird eine bequeme experimentelle Methode zur Messung des Polarisationsgrades und des Rabi Flip-Winkels der 3He Kernspin Polarisation vorgestellt. Letztere Messung ist sehr wichtig für die Anwendung in hochpräzisions Experimenten.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To evaluate the function of the parotid glands before and during gustatory stimulation, using an intrinsic susceptibility-weighted MRI method (blood oxygenation level dependent, BOLD-MRI) at 1.5T and 3T. MATERIALS AND METHODS: A total of 10 and 13 volunteers were investigated at 1.5T and 3T, respectively. Measurements were performed before and during gustatory stimulation using ascorbate. Circular regions of interest (ROIs) were delineated in the left and right parotid glands, and in the masseter muscle for comparison. The effects of stimulation were evaluated by calculating the difference between the relaxation rates, DeltaR(2)*. Baseline and stimulation were statistically compared (Student's t-tests), merging both parotid glands. RESULTS: The averaged DeltaR(2)* values prestimulation obtained in all parotid glands were stable (-0.61 to 0.38 x 10(-3) seconds(-1)). At 3T, these values were characterized by an initial drop (to -2.7 x 10(-3) seconds(-1)) followed by a progressive increase toward the baseline. No significant difference was observed between baseline and parotid gland stimulation at 1.5T, neither for the masseter muscle at both field strengths. A considerable interindividual variability (over 76%) was noticed at both magnetic fields. CONCLUSION: BOLD-MRI at 3T was able to detect DeltaR(2)* changes in the parotid glands during gustatory stimulation, consistent with an increase in oxygen consumption during saliva production.