986 resultados para Postoperative Myocardial-ischemia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Serum levels of troponin and heart-related fraction of creatine kinase (CK-MB) mass are used as diagnostic and prognostic criteria in myocardial infarction, but the relation between those levels and-the necropsy-determined size of necrosis has not been tested in human beings. In this retrospective study, 1-cm-thick transverse sections of the ventricles were cut from the base to the apex in the necropsy hearts of 27 patients aged 47 to 86 years (mean 66, median 69; 19 men). Total and necrotic areas were measured using a computer-linked image analysis system. The weights of the necrotic areas were also calculated. The correlations of the areas and weights of necrotic myocardium with the highest serum values of CK-MB mass and troponin 1, which had been quantified during life by chemiluminescence immunoassays, were verified by Pearson`s test; results were considered significant at p <= 50.05. Significant correlations were detected between CK-MB mass peak and infarct size (r = 0.63, p < 0.01) and weight (r = 0.69, p < 0.01) and between CK-MB mass and highest troponin level (r = 0.73, p < 0.01); however, the correlations between highest troponin level and myocardial infarct size (r = 0.31, p = 0.11) and weight (r = 0.35, p = 0.07) were small and nonsignificant. In conclusion, despite the well-established role of serum levels of troponin as a diagnostic tool for myocardial infarction, their highest values showed poor correlations with the extent of infarct. In contrast, the highest serum level of CK-MB mass was well correlated with myocardial infarct size. (c) 2008 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective-To compare analgesic effects of tramadol, codeine, and ketoprofen administered alone and in combination and their effects on concentrations of blood glucose, serum cortisol, and serum interleukin (IL)-6 in dogs undergoing maxillectomy or mandibulectomy. Animals-42 dogs with oral neoplasms. Procedures-30 minutes before the end of surgery, dogs received SC injections of tramadol (2 mg/kg), codeine (2 mg/kg), ketoprofen (2 mg/kg), tramadol + ketoprofen, or codeine + ketoprofen (at the aforementioned dosages). Physiologic variables, analgesia, and sedation were measured before (baseline) and 1, 2, 3, 4, 5, and 24 hours after surgery. Blood glucose, serum cortisol, and serum IL-6 concentrations were measured 1, 3, 5, and 24 hours after administration of analgesics. Results-All treatments provided adequate postoperative analgesia. Significant increases in mean +/- SD blood glucose concentrations were detected in dogs receiving tramadol (96 +/- 14 mg/dL), codeine (120 +/- 66 mg/dL and 96 +/- 21 mg/dL), ketoprofen (105 +/- 22 mg/dL), and codeine + ketoprofen (104 +/- 16 mg/dL) at 5, 1 and 3, 5, and 3 hours after analgesic administration, respectively, compared with preoperative (baseline) values. There were no significant changes in physiologic variables, serum IL-6 concentrations, or serum cortisol concentrations. Dogs administered codeine + ketoprofen had light but significant sedation at 4, 5, and 24 hours. Conclusions and Clinical Relevance-Opioids alone or in combination with an NSAID promoted analgesia without adverse effects during the 24-hour postoperative period in dogs undergoing maxillectomy or mandibulectomy for removal of oral neoplasms. (Am J Vet Res 2010;71:1019-1026)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Severely resorbed mandibles often present a short band of keratinized tissue associated with a shallow vestibule. As a result, prominent muscle insertions are present, especially in the mental region of the mandible. This case report describes the deepening of the vestibular sulcus in an atrophic mandible by combining free gingival grafts harvested from the palate and a postoperative acrylic resin stent screwed on osseointegrated implants placed at the anterior region of the mandible. Study design. During the second-stage surgery, a split-thickness labial flap was reflected and apically sutured onto the periosteum. Two free gingival grafts were obtained and then sutured at this recipient site. A previously custom-made acrylic stent was then screwed onto the most distally positioned implants. To document the procedure`s stability over time, a metal ball was placed in the most apical part of the vestibule and standardized cephalometric radiographs were taken before and 6 months after the procedure. Linear measurements of vestibular depths over the observation time were realized using specific software for radiographic analysis. Results. The proposed technique augmented the band of attached masticatory mucosa, deepened the vestibule and prevented the muscle reinsertion. The difference between the 2 measurements of vestibular depths was 9.39 mm (initial 20.88 mm, final 11.49 mm) after a 6-month postoperative period. Conclusion. The technique, in combination with palatal mucosal graft and use of a postoperative stent, decreased the pull of mentalis muscle and provided a peri-implantally stable soft tissue around implants. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 106: e7-e14)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, 53 patients received piroxicam, administered orally or sublingually, after undergoing removal of symmetrically positioned lower third molars, during two separate appointments. This study used a randomized, blind, cross-over protocol. Objective and subjective parameters were recorded for comparison of postoperative results for 7 days after surgery. Patients treated with oral or sublingual piroxicam reported low postoperative pain scores. The patients who received piroxicam orally took a similar average amount of analgesic rescue medication compared with patients who received piroxicam sublingually (p > 0.05). Patients exhibited similar values for mouth opening measured just before surgery and immediately following suture removal 7 days later (p > 0.05), and showed no significant differences between routes of piroxicam administration for swelling control during the second or seventh postoperative days (p > 0.05). In summary, pain, trismus and swelling after lower third molar extraction, independent of surgical difficulty, could be controlled by piroxicam 20 mg administered orally or sublingually and no significant differences were observed between the route of delivery used in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To measure factors associated with underuse of beta-blocker therapy after myocardial infarction (MI). Methods: The Newcastle and Perth collaborating centres of the World Health Organization (WHO) MONICA project (to MONItor trends and determinants of Cardiovascular disease) systematically evaluated all patients admitted to hospital in their respective regions with possible MI. A total of 1766 patients in Newcastle and 4503 patients in Perth, discharged from hospital after confirmed MI from 1985 to 1993, were studied, Rates of beta-blocker use before and after hospital discharge were evaluated and correlates of beta-blocker use determined. Results: Beta-blocker use was similar in Newcastle and Perth before MI (21% of patients in each centre). During hospital admission, beta-blocker therapy was initiated nearly twice as frequently in Perth compared with Newcastle (66 vs 36%, respectively) and more patients were discharged from hospital on beta-blockers in Perth (68%) than in Newcastle (45%). The main factors associated with underuse of beta-blockers in multivariate analysis were geographical centre (odds ratio (OR) for Newcastle compared with Perth 0.3 95% confidence interval (CI) 0.3-0.3), a history of previous MI (OR 0.6, 95% CI 0.5-0.7), admission to hospital in earlier years (OR 0.4, 95% CI 0.3-0.4 for years 1985-87 compared with years 1991-93), diabetes (OR 0.6, 95% CI 0.5-0.8) and the concomitant use of diuretics (OR 0.5, 95% CI 0.4-0.6) and calcium antagonists (OR 0.6, 95% CI 0.5-0.8). Conclusions: Underuse of beta-blockers after MI was strongly related to hospital prescribing patterns and not to community use of beta-blockers. Underuse occurred in patients with diabetes and in patients with left ventricular dysfunction, patients who stand to benefit most from beta-blocker use following MI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective-To compare the accuracy and feasibility of harmonic power Doppler and digitally subtracted colour coded grey scale imaging for the assessment of perfusion defect severity by single photon emission computed tomography (SPECT) in an unselected group of patients. Design-Cohort study. Setting-Regional cardiothoracic unit. Patients-49 patients (mean (SD) age 61 (11) years; 27 women, 22 men) with known or suspected coronary artery disease were studied with simultaneous myocardial contrast echo (MCE) and SPECT after standard dipyridamole stress. Main outcome measures-Regional myocardial perfusion by SPECT, performed with Tc-99m tetrafosmin, scored qualitatively and also quantitated as per cent maximum activity. Results-Normal perfusion was identified by SPECT in 225 of 270 segments (83%). Contrast echo images were interpretable in 92% of patients. The proportion of normal MCE by grey scale, subtracted, and power Doppler techniques were respectively 76%, 74%, and 88% (p < 0.05) at > 80% of maximum counts, compared with 65%, 69%, and 61% at < 60% of maximum counts. For each technique, specificity was lowest in the lateral wail, although power Doppler was the least affected. Grey scale and subtraction techniques were least accurate in the septal wall, but power Doppler showed particular problems in the apex. On a per patient analysis, the sensitivity was 67%, 75%, and 83% for detection of coronary artery disease using grey scale, colour coded, and power Doppler, respectively, with a significant difference between power Doppler and grey scale only (p < 0.05). Specificity was also the highest for power Doppler, at 55%, but not significantly different from subtracted colour coded images. Conclusions-Myocardial contrast echo using harmonic power Doppler has greater accuracy than with grey scale imaging and digital subtraction. However, power Doppler appears to be less sensitive for mild perfusion defects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The subjective interpretation of dobutamine echocardiography (DBE) makes the accuracy of this technique dependent on the experience of the observer, and also poses problems of concordance between observers. Myocardial tissue Doppler velocity (MDV) may offer a quantitative technique for identification of coronary artery disease, but it is unclear whether this parameter could improve the results of less expert readers and in segments with low interobserver concordance. The aim of this study was to find whether MDV improved the accuracy of wall motion scoring in novice readers, experienced echocardiographers, and experts in stress echocardiography, and to identify the optimal means of integrating these tissue Doppler data in 77 patients who underwent DBE and angiography. New or worsening abnormalities were identified as ischemia and abnormalities seen at rest as scarring. Segmental MDV was measured independently and previously derived cutoffs were applied to categorize segments as normal or ab normal. Five strategies were used to combine MDV and wall motion score, and the results of each reader using each strategy were compared with quantitative coronary angiography. The accuracy of wall motion scoring by novice (68 +/- 3%) and experienced echocardiographers (71 +/- 3%) was less than experts in stress echocardiography (88 +/- 3%, p < 0.001). Various strategies for integration with MDV significantly improved the accuracy of wall motion scoring by novices from 75 +/- 2% to 77 +/- 5% (p < 0.01). Among the experienced group, accuracy improved from 74 +/- 2% to 77 +/- 5% (p < 0.05), but in the experts, no improvement was seen from their baseline accuracy. Integration with MDV also improved discordance related to the basal segments. Thus, use of MDV in all segments or MDV in all segments with wall motion scoring in the apex offers an improvement in sensitivity and accuracy with minimal compromise in specificity. (C) 2001 by Excerpta Medica, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Tobacco cessation after acute myocardial infarction (AMI) substantially improves outcome but how effective individual programmes are needs to be established. To date, few studies have examined this factor. Aims: To assess the outcome of two smoking cessation programmes after AMI. Methods: One hundred and ninety-eight current smokers admitted to coronary care with an AMI participated in a randomized controlled study comparing two outpatient tobacco interventions, the Stanford Heart Attack Staying Free (SF) programme and a Usual Care (UC) programme. Results: Log-rank analyses revealed that patients in the SF programme were retained longer (P < 0.001) and had higher cotinine validated abstinence rates (P < 0.001) compared with patients in the UC programme. Twelve months after intervention, 39% of the SF programme compared with 2% of the UC programme demonstrated cotinine validated tobacco cessation, representing a significant reduced relapse rate in the SF programme (chi (2), P < 0.001). Conclusions: The SF smoking cessation programme initiated in hospital can significantly reduce smoking rates at 12 months after myocardial infarction. Although superior to the UC quit programme, Australian outcomes were lower than the American programme originators' published outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The aim of this study is to look at the efficacy of extended surgical staging and postoperative vaginal vault brachytherapy in patients with Stage II (occult) endometrial carcinoma. Methods. Between January 1989 and December 1997, there were 30 patients with Stage II (occult) endometrial carcinoma who received postoperative vaginal vault brachytherapy as the only adjuvant treatment. The study group consisted of 15 of these patients who had extended surgical staging (including lymphadenectomy). Results. At a median follow-up of 36 months (range 17 to 113 months), there has been no recurrence. There were no major complications from surgery. Only 1 patient had mild rectal bleeding following vaginal vault brachytherapy and there were no grade 3 or 4 bowel toxicities. Conclusions. Extended surgical staging and postoperative vaginal vault brachytherapy for Stage II (occult) endometrial carcinoma is associated with minimal morbidity and excellent survival. (C) 2001 Academic Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tissue type plasminogen activator is available, through recombinant technology, for thrombolytic use as alteplase. Alteplase is relatively clot specific and should cause less bleeding side effects than the non-specific agents such as streptokinase. Alteplase has been used successfully in evolving myocardial infarction (MI) to reopen occluded coronary arteries. It is probably equally effective or superior to streptokinase in opening arteries and reducing mortality in Mi. Alteplase is most effective when given early in Mi and is probably ineffective when given 12 h after the onset of symptoms. The effectiveness of alteplase in Mi can be increased by front loading with a bolus of 15 mg, followed by an infusion of 50 mg over 30 min and 35 mg over 60 min. Percutaneous transluminal coronary angioplasty or stenting is associated with a greater patency and lower rates of serious bleeding, recurrent ischaemia and death than alteplase in MI and is likely to take over from alteplase as the standard Mi treatment. A reduced dose of alteplase to increase coronary artery patency prior to angioplasty may be useful in Mi. An exciting new indication for the use of alteplase is in stroke, where it has become the first beneficial intervention. Alteplase is used to reopen occluded cerebral vessels but is associated with an increased risk of intracerebral haemorrhage. Alteplase is beneficial if given within 3 h of the onset of stroke but not after this time period. Therefore, the next challenge is to increase the percentage of people being diagnosed and treated within this period. Clinical trials have not established a role for alteplase in the treatment of acute coronary syndromes or deep vein thrombosis. However, alteplase is useful in treating pulmonary thromboembolism and peripheral vascular disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To determine (i) factors which predict whether patients hospitalised with acute myocardial infarction (AMI) receive care discordant with recommendations of clinical practice guidelines; and (ii) whether such discordant care results in worse outcomes compared with receiving guideline-concordant care. Design: Retrospective cohort study. Setting: Two community general hospitals. Participants: 607 consecutive patients admitted with AMI between July 1997 and December 2000. Main outcome measures: Clinical predictors of discordant care; crude and risk-adjusted rates of inhospital mortality and reinfarction, and mean length of hospital stay. Results: At least one treatment recommendation for AMI was applicable for 602 of the 607 patients. Of these patients, 411(68%) received concordant care, and 191 (32%) discordant care. Positive predictors at presentation of discordant care were age > 65 years (odds ratio [OR], 2.5; 95% Cl, 1.7-3.6), silent infarction (OR, 2.7; 95% Cl, 1.6-4.6), anterior infarction (OR, 2.5; 95% Cl, 1.7-3.8), a history of heart failure (OR, 6.3; 95% Cl, 3.7-10.7), chronic atrial fibrillation (OR, 3.2; 95% Cl, 1.5-6.4); and heart rate greater than or equal to 100 beats/min (OR, 2.1; 95% Cl, 1.4-3.1). Death occurred in 12.0% (23/191) of discordant-care patients versus 4.6% (19/411) of concordant-care patients (adjusted OR, 2.42; 95% Cl, 1.22-4.82). Mortality was inversely related to the level of guideline concordance (P = 0.03). Reinfarction rates also tended to be higher in the discordant-care group (4.2% v 1.7%; adjusted OR, 2.5; 95% Cl, 0.90-7.1). Conclusions: Certain clinical features at presentation predict a higher likelihood of guideline-discordant care in patients presenting with AMI Such care appears to increase the risk of inhospital death.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Diastolic dysfunction induced by ischemia may alter transmitral blood flow, but this reflects global ventricular function, and pseudonormalization may occur with increased preload. Tissue Doppler may assess regional diastolic function and is relatively load-independent, but limited data exist regarding its application to stress testing. We sought to examine the stress response of regional diastolic parameters to dobutomine echocardiography (DbE). Methods Sixty-three patients underwent study with DbE: 20 with low probability of coronary artery disease (CAD) and 43 with CAD who underwent angiography. A standard DbE protocol was used, and segments were categorized as ischemic, scar, or normal. Color tissue Doppler was acquired at baseline and peak stress, and waveforms in the basal and mid segments were used to measure early filling (Em), late filling (Am), and E deceleration time. Significant CAD was defined by stenoses >50% vessel diameter. Results Diastolic parameters had limited feasibility because of merging of Em and Am waves at high heart rates and limited reproducibility. Nonetheless, compared with normal segments, segments subtended with significant stenoses showed a lower Em velocity at rest (6.2 +/- 2.6 cm/s vs 4.8 +/- 2.2 cm/s, P < .0001) and peak (7.5 +/- 4.2 cm/s vs 5.1 +/- 3.6 cm/s, P < .0001), Abnormal segments also showed a shorter E deceleration time (51 +/- 27 ms vs 41 +/- 27 ms, P = .0001) at base and peak. No changes were documented in Am. The same pattern was seen with segments identified as ischemic with wall motion score. However, in the absence of ischemia, segments of patients with left ventricular hypertrophy showed a lower Em velocity, with blunted Em responses to stress. Conclusion Regional diastolic function is sensitive to ischemia. However, a number of practical limitations limit the applicability of diastolic parameters for the quantification of stress echocardiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Tissue Doppler may be used to quantify regional left ventricular function but is limited by segmental variation of longitudinal velocity from base to apex and free to septal walls. We sought to overcome this by developing a composite of longitudinal and radial velocities. Methods and Results. We examined 82 unselected patients undergoing a standard dobutamine echocardiogram. Longitudinal velocity was obtained in the basal and mid segments of each wall using tissue Doppler in the apical views. Radial velocities were derived in the same segments using an automated border detection system and centerline method with regional chords grouped according to segment location and temporally averaged. In 25 patients at low probability of coronary disease, the pattern of regional variation in longitudinal velocity (higher in the septum) was the opposite of radial velocity (higher in the free wall) and the combination was homogenous. In 57 patients undergoing angiography, velocity in abnormal segments was less than normal segments using longitudinal (6.0 +/- 3.6 vs 9.0 +/- 2.2 cm/s, P = .01) and radial velocity (6.0 +/- 4.0 vs 8.0 +/- 3.9 cm/s, P = .02). However, the composite velocity permitted better separation of abnormal and normal segments (13.3 +/- 5.6 vs 17.5 +/- 4.2 cm/s, P = .001). There was no significant difference between the accuracy of this quantitative approach and expert visual wall motion analysis (81% vs 84%, P = .56). Conclusion: Regional variation of uni-dimensional myocardial velocities necessitates site-specific normal ranges, probably because of different fiber directions. Combined analysis of longitudinal and radial velocities allows the derivation of a composite velocity, which is homogenous in all segments and may allow better separation of normal and abnormal myocardium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Systolic myocardial Doppler velocity accurately identifies coronary artery disease. However, these velocities may be affected by age, hemodynamic responses to stress, and left ventricular cavity size. We sought to examine the influences of these variables on myocardial velocity during dobutamine stress in patients with normal wall motion. Methods One hundred seventy-nine consecutive patients with normal dobutamine echocardiograms were studied. Color myocardial tissue Doppler data were obtained at rest and peak stress, and peak systolic myocardial velocity (PSV) was measured in all basal and midventricular segments. Velocities at rest and peak stress were compared with left ventricular diastolic and systolic volumes, blood pressure, heart rate, and age by Pearson correlation and interdecile analysis by use of analysis of variance. Results The only clinical variable correlating with velocity was age; PSV showed only mild correlation with age at rest (r(2) = 0.01, P = .001) and peak stress (r(2) = 0.02, P = .001), but the normal peak velocity was significantly different between the extremes of age (<44 years and >74 years). There was very weak correlation of PSV with systolic and diastolic blood pressure (r(2) < 0.01), heart rate (r(2) < 0.01), systemic vascular resistance (r(2) = 0.08), and left ventricular volumes (r(2) < 0.01). Conclusions Peak systolic velocity during dobutamine stress is relatively independent of hemodynamic factors and left ventricular cavity size. The extremes of age may influence peak systolic Doppler velocities. These results suggest that peak systolic velocity may be a robust quantitative measure during dobutamine echocardiography across most patient subgroups.