848 resultados para Polymerization, Metallocene, Tandem, Fiber, Heterogeneous


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a task for eliciting attitudes toward risk that is close to real-world risky decisions which typically involve gains and losses. The task consists of accepting or rejecting gambles that provide a gain with probability p and a loss with probability 1−p . We employ finite mixture models to uncover heterogeneity in risk preferences and find that (i) behavior is heterogeneous, with one half of the subjects behaving as expected utility maximizers, (ii) for the others, reference-dependent models perform better than those where subjects derive utility from final outcomes, (iii) models with sign-dependent decision weights perform better than those without, and (iv) there is no evidence for loss aversion. The procedure is sufficiently simple so that it can be easily used in field or lab experiments where risk elicitation is not the main experiment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study shows the possibility offered by modern ultra-high performance supercritical fluid chromatography combined with tandem mass spectrometry in doping control analysis. A high throughput screening method was developed for 100 substances belonging to the challenging classes of anabolic agents, hormones and metabolic modulators, synthetic cannabinoids and glucocorticoids, which should be detected at low concentrations in urine. To selectively extract these doping agents from urine, a supported liquid extraction procedure was implemented in a 48-well plate format. At the tested concentration levels ranging from 0.5 to 5 ng/mL, the recoveries were better than 70% for 48-68% of the compounds and higher than 50% for 83-87% of the tested substances. Due to the numerous interferences related to isomers of steroids and ions produced by the loss of water in the electrospray source, the choice of SFC separation conditions was very challenging. After careful optimization, a Diol stationary phase was employed. The total analysis time for the screening assay was only 8 min, and interferences as well as susceptibility to matrix effect (ME) were minimized. With the developed method, about 70% of the compounds had relative ME within the range ±20%, at a concentration of 1 and 5 ng/mL. Finally, limits of detection achieved with the above-described strategy including 5-fold preconcentration were below 0.1 ng/mL for the majority of the tested compounds. Therefore, LODs were systematically better than the minimum required performance levels established by the World anti-doping agency, except for very few metabolites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[cat] Aquest estudi destaca la importància de considerar un nivell d’agregació adequat en els anàlisis de demanda, ja que treballar utilitzant un nivell d’agregació inadequat pot donar lloc a estimacions esbiaixades. Aquest fet es mostra a través de l’anàlisi de diferents productes de lluç fresc comercialitzats a Mercabarna, el mercat majorista de Barcelona. La literatura sobre la demanda de peix tracta al lluç com un únic producte i espècie. No obstant això, en el mercat espanyol, es comercialitzen molts peixos com a lluç, els quals mostren comportaments molt diferents (des de béns inferiors fins a béns de luxe). Els resultats obtinguts, en concordança amb les observacions empíriques, demostren que l’anàlisi s’ha de realitzar amb un major grau de detall que a nivell d’espècie. Això qüestiona els resultats d’anteriors estudis de demanda i la majoria de les bases de dades, on l’observació del nivell d’agregació adequat dels productes no es té en compte.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[cat] Aquest estudi destaca la importància de considerar un nivell d’agregació adequat en els anàlisis de demanda, ja que treballar utilitzant un nivell d’agregació inadequat pot donar lloc a estimacions esbiaixades. Aquest fet es mostra a través de l’anàlisi de diferents productes de lluç fresc comercialitzats a Mercabarna, el mercat majorista de Barcelona. La literatura sobre la demanda de peix tracta al lluç com un únic producte i espècie. No obstant això, en el mercat espanyol, es comercialitzen molts peixos com a lluç, els quals mostren comportaments molt diferents (des de béns inferiors fins a béns de luxe). Els resultats obtinguts, en concordança amb les observacions empíriques, demostren que l’anàlisi s’ha de realitzar amb un major grau de detall que a nivell d’espècie. Això qüestiona els resultats d’anteriors estudis de demanda i la majoria de les bases de dades, on l’observació del nivell d’agregació adequat dels productes no es té en compte.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Kandidaatintyön tarkoituksena oli tutkia tandem-MAG-hitsauksen soveltuvuutta tuotteen X hitsaamiseen vaaka-asennossa. Työssä selvitettiin tuotteen X hitsaukseen optimaaliset hitsausparametrit sekä varmistettiin hitsin laatu ja luotettavuus. Päätavoite oli saavuttaa mahdollisimman suuri hitsausnopeus, varmistaa hitsin juuren puolen luotettava sulaminen ja saavuttaa mahdollisimman roiskeeton hitsi. Lisäksi tutkittiin alustavasti laserleikattujen railojen pinnanlaadun ja leikkauskaasun vaikutusta tandem-MAG-hitsauksessa, ilmaraon vaikutusta tandem-MAG-hitsauksessa sekä MAG-siltahitsien sulamista juuren puolelta. Koehitsausten pohjalta laadittiin alustava hitsausohje (pWPS). Koehitsaukset tehtiin Lappeenrannan teknillisen yliopiston hitsaustekniikan laboratoriossa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, preliminary results of the use of hydrophobic thin films obtained by plasma deposition to protect grains and seeds are presented: grains coated by the films did not present biological degradation when stored in a saturated water vapor environment, but had their germination accelerated in the presence of water. A model that explains the difference of behavior of the films when exposed to water in vapor form or in liquid form, based on the formation of microchannels within the film that lead to water uptake in seeds, is presented. The model was successfully tested using quartz crystal measurements, which showed that the microchannels within the films can favor the adsorption and permeation of water when the films are immersed in water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work shows a method for the determination of chloramphenicol (CAP) antibiotic in milk, powder milk and honey. The solid phase extraction and liquid-liquid extraction were applied as a clean-up and pre-concentration strategies followed by LC-ESI/MS/MS analysis. The recovery was studied for different fortification levels from 0.05 to 1.00 µg L-1 in milk, showing values between 91 101% and RSD bellow 8.0%, while honey was spiked with a concentration of 0.20 µg kg-1 yelding a mean recovery of 83% and RSD of 6.5%. The quantification transition 321>152 showed a LOD of 0.52 ng kg-1 and LOQ of 1.85 ng kg-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the use of an optical fiber sensor to measure the soybean oil concentration in samples obtained from the mixture of pure biodiesel and commercial soybean oil. The operation of the device is based on the long-period grating sensitivity to the surrounding medium refractive index, which leads to measurable modifications in the grating transmission spectrum. The proposed analysis method results in errors in the oil concentration of 0.4% and 2.6% for pure biodiesel and commercial soybean oil, respectively. Techniques of total glycerol, dynamic viscosity, density, and hydrogen nuclear magnetic resonance spectroscopy were also employed to validate the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mechanical properties of biological cells have long been considered as inherent markers of biological function and disease. However, the screening and active sorting of heterogeneous populations based on serial single-cell mechanical measurements has not been demonstrated. Here we present a novel monolithic glass chip for combined fluorescence detection and mechanical phenotyping using an optical stretcher. A new design and manufacturing process, involving the bonding of two asymmetrically etched glass plates, combines exact optical fiber alignment, low laser damage threshold and high imaging quality with the possibility of several microfluidic inlet and outlet channels. We show the utility of such a custombuilt optical stretcher glass chip by measuring and sorting single cells in a heterogeneous population based on their different mechanical properties and verify sorting accuracy by simultaneous fluorescence detection. This offers new possibilities of exact characterization and sorting of small populations based on rheological properties for biological and biomedical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this research work “Identification of the Emerging Issues in Recycled Fiber processing” are discovering of emerging research issues and presenting of new approaches to identify promising research themes in recovered paper application and production. The projected approach consists of identifying technological problems often encountered in wastepaper preparation processes and also improving the quality of recovered paper and increasing its proportion in the composition of paper and board. The source of information for the problem retrieval is scientific publications in which waste paper application and production were discussed. The study has exploited several research methods to understand the changes related to utilization of recovered paper. The all assembled data was carefully studied and categorized by applying software called RefViz and CiteSpace. Suggestions were made on the various classes of these problems that need further investigation in order to propose an emerging research trends in recovered paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main topics related to the use of dual-site catalysts in the production of polymers with broad molecular weight distribution are reviewed. The polymerization using dual-site catalysts is more economical and allows to produce a higher quality product than other processes, such as polymer blend and multistage reactors. However, the formulation of these catalysts is quite complicated since the same catalyst must produce distinct polymer grades. In addition, the release of patents concerning the combination of metallocenes and new technologies for polymerization shows that polymerization processes using dual-site catalysts are of current industrial interest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work shows results on the characterization, by liquid chromatography coupled to high resolution tandem mass spectrometry (LC-IT-TOF-MS) with electrospray ionization, of organic compounds present in raw and treated effluents from a combined sewage treatment systems (upflow anaerobic sludge blanket-trickling filter). The sewage samples were prepared by C18 solid phase extraction and the spectra obtained from the various extracts were submitted to principal component analysis to evaluate their pattern and identify the major deprotonated species. Some target compounds were submitted to semiquantitative analysis, using phenolphtalein as internal standard. The results showed the anaerobic step had little impact on the removal of anionic surfactants (LAS), fatty acids, and some contaminantes such as bisphenol A and bezafibrate, whereas the aerobic post-treatment was very efficient in removing these organics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A LC-ESI-MS/MS method was developed and validated according to the European Union decision 2002/657/EC, for the determination of tetracyclines (TCs) in chicken-muscle since Europe is one of the main markets for Brazilian products. Linearity of r > 0.9979, limits of quantification in the range of 7.0-35.0 ng/g, average recoveries of 89.38 - 106.27%, within-day and between-day precision were adequate for all TCs. The decision limit and the detection capability were 93.00-106.46 ng/g and 95.84-114.38 ng/g, respectively. This method is suitable for application in surveillance programmes of residues of TCs in chicken-muscle samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method using LC/ESI-MS/MS for the quantitative analysis of Ochratoxin A in roasted coffee was described. Linearity was demonstrated (r = 0.9175). The limits of detection and quantification were 1.0 and 3.0 ng g-1, respectively. Trueness, repeatability and intermediate precision values were 89.0-108.8%; 2.4-13.7%; 12.5-17.8%, respectively. To the best of our knowledge, this is the first report in which Ochratoxin A in roasted coffee is analysed by LC/ESI-MS/MS, contributing to the field of mycotoxin analysis, and it will be used for future production of Certified Reference Material.