957 resultados para OPTIMAL CONTROL
Resumo:
The performance of the optimal linear feedback control and of the state-dependent Riccati equation control techniques applied to control and to suppress the chaotic motion in the atomic force microscope are analyzed. In addition, the sensitivity of each control technique regarding to parametric uncertainties are considered. Simulation results show the advantages and disadvantages of each technique. © 2013 Brazilian Society for Automatics - SBA.
Resumo:
O diagnóstico precoce e o tratamento adequado dos casos de malária é a principal estratégia para o controle da doença. Várias alternativas para o diagnóstico microscópico tradicional foram propostas nos últimos anos, os testes imunocromatográficos que capturam antígenos alvos dos parasitos da malária estão sendo propostos, como o teste OptiMAL-IT® que detecta a desidrogenase lática do Plasmodium sp.. O estudo teve como objetivo a avaliação do nível de concordância entre o teste imunocromatográfico (OptiMAL-IT®) e a gota espessa para o diagnóstico da malária no Município de Mazagão – Amapá. Foram analisados 413 indivíduos com sintomatologia de malária, que procuraram o serviço da Unidade Mista de Saúde de Mazagão, com idade entre 01-68 anos. Os resultados do teste OptiMAL-IT® foram comparados com os resultados obtidos (das amostras) através da gota espessa corada pelo Giemsa. Dos 413 pacientes suspeitos de apresentarem malária, 317(76.8%) eram positivos através da GE e 311 (75.3%) eram positivos pelo TDR. Das lâminas de GE positivas, foram encontrados 27.4% de P. falciparum e 72.6% de P. vivax. O teste OptiMAL-IT® detectou 27.7% de P. falciparum e 72.3% de P. vivax. A sensibilidade obtida com o TDR para o P. falciparum foi de 97.7% e para o P. vivax foi de 98.2%, a sensibilidade global do TDR foi de 98.1% e a especificidade global e para ambas as espécies foi de 100%. Foram encontrados valores preditivos positivos e negativos de 100% e 94.1%, respectivamente. O teste OptiMAL-IT®, teve uma alta concordância com a GE, foi específico e eficiente, podendo ser usado no diagnóstico de malária nas situações onde a microscopia não está disponível.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Research has shown that applying the T-2 control chart by using a variable parameters (VP) scheme yields rapid detection of out-of-control states. In this paper, the problem of economic statistical design of the VP T-2 control chart is considered as a double-objective minimization problem with the statistical objective being the adjusted average time to signal and the economic objective being expected cost per hour. We then find the Pareto-optimal designs in which the two objectives are met simultaneously by using a multi-objective genetic algorithm. Through an illustrative example, we show that relatively large benefits can be achieved by applying the VP scheme when compared with usual schemes, and in addition, the multi-objective approach provides the user with designs that are flexible and adaptive.
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Manipulation of follicle development to ensure optimal oocyte quality and conception rates in cattle
Resumo:
Over the last several decades, a number of therapies have been developed that manipulate ovarian follicle growth to improve oocyte quality and conception rates in cattle. Various strategies have been proposed to improve the responses to reproductive biotechnologies following timed artificial insemination (TAI), superovulation (SOV) or ovum pickup (OPU) programmes. During TAI protocols, final follicular growth and size of the ovulatory follicle are key factors that may significantly influence oocyte quality, ovulation, the uterine environment and consequently pregnancy outcomes. Progesterone concentrations during SOV protocols influence follicular growth, oocyte quality and embryo quality; therefore, several adjustments to SOV protocols have been proposed depending on the animal category and breed. In addition, the success of in vitro embryo production is directly related to the number and quality of cumulus oocyte complexes harvested by OPU. Control of follicle development has a significant impact on the OPU outcome. This article discusses a number of key points related to the manipulation of ovarian follicular growth to maximize oocyte quality and improve conception rates following TAI and embryo transfer of in vivo-and in vitro-derived embryos in cattle.
Resumo:
It is well known that control systems are the core of electronic differential systems (EDSs) in electric vehicles (EVs)/hybrid HEVs (HEVs). However, conventional closed-loop control architectures do not completely match the needed ability to reject noises/disturbances, especially regarding the input acceleration signal incoming from the driver's commands, which makes the EDS (in this case) ineffective. Due to this, in this paper, a novel EDS control architecture is proposed to offer a new approach for the traction system that can be used with a great variety of controllers (e. g., classic, artificial intelligence (AI)-based, and modern/robust theory). In addition to this, a modified proportional-integral derivative (PID) controller, an AI-based neuro-fuzzy controller, and a robust optimal H-infinity controller were designed and evaluated to observe and evaluate the versatility of the novel architecture. Kinematic and dynamic models of the vehicle are briefly introduced. Then, simulated and experimental results were presented and discussed. A Hybrid Electric Vehicle in Low Scale (HELVIS)-Sim simulation environment was employed to the preliminary analysis of the proposed EDS architecture. Later, the EDS itself was embedded in a dSpace 1103 high-performance interface board so that real-time control of the rear wheels of the HELVIS platform was successfully achieved.
Resumo:
Background The optimal revascularization strategy for diabetic patients with multivessel coronary artery disease (MVD) remains uncertain for lack of an adequately powered, randomized trial. The FREEDOM trial was designed to compare contemporary coronary artery bypass grafting (CABG) to percutaneous coronary intervention (PCI) with drug-eluting stents in diabetic patients with MVD against a background of optimal medical therapy. Methods A total of 1,900 diabetic participants with MVD were randomized to PCI or CABG worldwide from April 2005 to March 2010. FREEDOM is a superiority trial with a mean follow-up of 4.37 years (minimum 2 years) and 80% power to detect a 27.0% relative reduction. We present the baseline characteristics of patients screened and randomized, and provide a comparison with other MVD trials involving diabetic patients. Results The randomized cohort was 63.1 +/- 9.1 years old and 29% female, with a median diabetes duration of 10.2 +/- 8.9 years. Most (83%) had 3-vessel disease and on average took 5.5 +/- 1.7 vascular medications, with 32% on insulin therapy. Nearly all had hypertension and/or dyslipidemia, and 26% had a prior myocardial infarction. Mean hemoglobin A1c was 7.8 +/- 1.7 mg/dL, 29% had low-density lipoprotein <70 mg/dL, and mean systolic blood pressure was 134 +/- 20 mm Hg. The mean SYNTAX score was 26.2 with a symmetric distribution. FREEDOM trial participants have baseline characteristics similar to those of contemporary multivessel and diabetes trial cohorts. Conclusions The FREEDOM trial has successfully recruited a high-risk diabetic MVD cohort. Follow-up efforts include aggressive monitoring to optimize background risk factor control. FREEDOM will contribute significantly to the PCI versus CABG debate in diabetic patients with MVD. (Am Heart J 2012;164:591-9.)
Resumo:
This work studies the optimization and control of a styrene polymerization reactor. The proposed strategy deals with the case where, because of market conditions and equipment deterioration, the optimal operating point of the continuous reactor is modified significantly along the operation time and the control system has to search for this optimum point, besides keeping the reactor system stable at any possible point. The approach considered here consists of three layers: the Real Time Optimization (RTO), the Model Predictive Control (MPC) and a Target Calculation (TC) that coordinates the communication between the two other layers and guarantees the stability of the whole structure. The proposed algorithm is simulated with the phenomenological model of a styrene polymerization reactor, which has been widely used as a benchmark for process control. The complete optimization structure for the styrene process including disturbances rejection is developed. The simulation results show the robustness of the proposed strategy and the capability to deal with disturbances while the economic objective is optimized.
Resumo:
Abstract Background In areas with limited structure in place for microscopy diagnosis, rapid diagnostic tests (RDT) have been demonstrated to be effective. Method The cost-effectiveness of the Optimal® and thick smear microscopy was estimated and compared. Data were collected on remote areas of 12 municipalities in the Brazilian Amazon. Data sources included the National Malaria Control Programme of the Ministry of Health, the National Healthcare System reimbursement table, hospitalization records, primary data collected from the municipalities, and scientific literature. The perspective was that of the Brazilian public health system, the analytical horizon was from the start of fever until the diagnostic results provided to patient and the temporal reference was that of year 2006. The results were expressed in costs per adequately diagnosed cases in 2006 U.S. dollars. Sensitivity analysis was performed considering key model parameters. Results In the case base scenario, considering 92% and 95% sensitivity for thick smear microscopy to Plasmodium falciparum and Plasmodium vivax, respectively, and 100% specificity for both species, thick smear microscopy is more costly and more effective, with an incremental cost estimated at US$549.9 per adequately diagnosed case. In sensitivity analysis, when sensitivity and specificity of microscopy for P. vivax were 0.90 and 0.98, respectively, and when its sensitivity for P. falciparum was 0.83, the RDT was more cost-effective than microscopy. Conclusion Microscopy is more cost-effective than OptiMal® in these remote areas if high accuracy of microscopy is maintained in the field. Decision regarding use of rapid tests for diagnosis of malaria in these areas depends on current microscopy accuracy in the field.