OBJECTIVE: External auditory canal cholesteatoma (EACC) is a rarity. Although there have been numerous case reports, there are only few systematic analyses of case series, and the pathogenesis of idiopathic EACC remains enigmatic. STUDY DESIGN: In a tertiary referral center for a population of 1.5 million inhabitants, 34 patients with 35 EACC (13 idiopathic [1 bilateral] and 22 secondary) who were treated between 1994 and 2006 were included in the study. RESULTS: EACC cardinal symptoms were longstanding otorrhea (65%) and dull otalgia (12%). Focal bone destruction in the external auditory canal with retained squamous debris and an intact tympanic membrane were characteristic. Only 27% of the patients showed conductive hearing loss exceeding 20 dB. Patients with idiopathic EACC had lesions typically located on the floor of the external auditory canal and were older, and the mean smoking intensity was also greater (p < 0.05) compared with patients with secondary EACC. The secondary lesions were assigned to categories (poststenotic [n = 6], postoperative [n = 6], and posttraumatic EACC [n = 4]) and rare categories (radiogenic [n = 2], postinflammatory [n = 1], and postobstructive EACC [n = 1]). In addition, we describe 2 patients with EACC secondary to the complete remission of a Langerhans cell histiocytosis of the external auditory canal. Thirty of 34 patients were treated surgically and became all free of recurrence, even after extensive disease. DISCUSSION: For the development of idiopathic EACC, repeated microtrauma (e.g., microtrauma resulting from cotton-tipped applicator abuse or from hearing aids) and diminished microcirculation (e.g., from smoking) might be risk factors. A location other than in the inferior portion of the external auditory canal indicates a secondary form of the disease, as in the case of 2 patients with atypically located EACC after years of complete remission of Langerhans cell histiocytosis, which we consider as a new posttumorous category and specific late complication of this rare disease.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The mammalian inner ear has very limited ability to regenerate lost sensory hair cells. This deficiency becomes apparent when hair cell loss leads to hearing loss as a result of either ototoxic insult or the aging process. Coincidently, with this inability to regenerate lost hair cells, the adult cochlea does not appear to harbor cells with a proliferative capacity that could serve as progenitor cells for lost cells. In contrast, adult mammalian vestibular sensory epithelia display a limited ability for hair cell regeneration, and sphere-forming cells with stem cell features can be isolated from the adult murine vestibular system. The neonatal inner ear, however, does harbor sphere-forming stem cells residing in cochlear and vestibular tissues. Here, we provide protocols to isolate sphere-forming stem cells from neonatal vestibular and cochlear sensory epithelia as well as from the spiral ganglion. We further describe procedures for sphere propagation, cell differentiation, and characterization of inner ear cell types derived from spheres. Sphere-forming stem cells from the mouse inner ear are an important tool for the development of cellular replacement strategies of damaged inner ears and are a bona fide progenitor cell source for transplantation studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Postnatally ascertained trisomy 16 mosaicism is a rare diagnosis, with only three reported cases to date with no defined clinical phenotype. Trisomy 16 mosaicism diagnosed prenatally is common and associated with variable pregnancy outcomes ranging from stillbirth with multiple congenital abnormalities to an apparently normal newborn, making the genetic counseling very challenging. It is not clear whether uniparental disomy (UPD) 16 contributes to the phenotype, although it has been suggested that maternal UPD 16 affects the rate of intra-uterine growth retardation (IUGR) and congenital anomalies. We report on two further cases of trisomy 16 mosaicism confined to fibroblasts diagnosed postnatally. Patient 1 presented at birth with severe hypospadias, unilateral postaxial polydactyly, and different hair color with midline demarcation. His growth and development were normal at 11 months of age. Patient 2 was born with IUGR, significant craniofacial and body asymmetry, asymmetric skin hyperpigmentation, unilateral hearing loss, scoliosis, VSD, unexplained dilated cardiomyopathy, feeding difficulties, failure to thrive, and recurrent respiratory tract infections. She died at 7 months of age from respiratory failure. These two further cases of postnatally diagnosed trisomy 16 mosaicism highlight the variability of clinical features and outcome in this diagnosis. While Patient 2 presented with typical features of chromosomal mosaicism, Patient 1 had mild and transient features with essentially normal outcome, suggesting that trisomy 16 mosaicism may be under-diagnosed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: Multiple studies have proved that microvascular decompression (MVD) is the treatment of choice in cases of medically refractory trigeminal neuralgia (TN). In the elderly, however, the surgical risks related to MVD are assumed to be unacceptably high and various alternative therapies have been proposed. We evaluated the outcomes of MVD in patients aged older than 65 years of age and compared them with the outcomes in a matched group of younger patients. The focus was on procedure-related morbidity rate and long-term outcome. METHODS: This was a retrospective study of 112 patients with TN operated on consecutively over 22 years. The main outcome measures were immediate and long-term postoperative pain relief and neurological status, especially function of trigeminal, facial, and cochlear nerves, as well as surgical complications. A questionnaire was used to assess long-term outcome: pain relief, duration of a pain-free period, need for pain medications, time to recurrence, pain severity, and need for additional treatment. RESULTS: The mean age was 70.35 years. The second and third branches of the trigeminal nerve were most frequently affected (37.3%). The mean follow-up period was 90 months (range, 48-295 months). Seventy-five percent of the patients were completely pain free, 11% were never pain free, and 14% experienced recurrences. No statistically significant differences existed in the outcome between the younger and older patient groups. Postoperative morbidity included trigeminal hypesthesia in 6.25%, hypacusis in 5.4%, and complete hearing loss, vertigo, and partial facial nerve palsy in 0.89% each. Cerebrospinal fluid leak and meningitis occurred in 1 patient each. There were no mortalities in both groups. CONCLUSION: MVD for TN is a safe procedure even in the elderly. The risk of serious morbidity or mortality is similar to that in younger patients. Furthermore, no significant differences in short- and long-term outcome were found. Thus, MVD is the treatment of choice in patients with medically refractory TN, unless their general condition prohibits it.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The cochlear implant (CI) is one of the most successful neural prostheses developed to date. It offers artificial hearing to individuals with profound sensorineural hearing loss and with insufficient benefit from conventional hearing aids. The first implants available some 30 years ago provided a limited sensation of sound. The benefit for users of these early systems was mostly a facilitation of lip-reading based communication rather than an understanding of speech. Considerable progress has been made since then. Modern, multichannel implant systems feature complex speech processing strategies, high stimulation rates and multiple sites of stimulation in the cochlea. Equipped with such a state-of-the-art system, the majority of recipients today can communicate orally without visual cues and can even use the telephone. The impact of CIs on deaf individuals and on the deaf community has thus been exceptional. To date, more than 300,000 patients worldwide have received CIs. In Switzerland, the first implantation was performed in 1977 and, as of 2012, over 2,000 systems have been implanted with a current rate of around 150 CIs per year. The primary purpose of this article is to provide a contemporary overview of cochlear implantation, emphasising the situation in Switzerland.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE To confirm the clinical efficacy and safety of a direct acoustic cochlear implant. STUDY DESIGN Prospective multicenter study. SETTING The study was performed at 3 university hospitals in Europe (Germany, The Netherlands, and Switzerland). PATIENTS Fifteen patients with severe-to-profound mixed hearing loss because of otosclerosis or previous failed stapes surgery. INTERVENTION Implantation with a Codacs direct acoustic cochlear implant investigational device (ID) combined with a stapedotomy with a conventional stapes prosthesis MAIN OUTCOME MEASURES Preoperative and postoperative (3 months after activation of the investigational direct acoustic cochlear implant) audiometric evaluation measuring conventional pure tone and speech audiometry, tympanometry, aided thresholds in sound field and hearing difficulty by the Abbreviated Profile of Hearing Aid Benefit questionnaire. RESULTS The preoperative and postoperative air and bone conduction thresholds did not change significantly by the implantation with the investigational Direct Acoustic Cochlear Implant. The mean sound field thresholds (0.25-8 kHz) improved significantly by 48 dB. The word recognition scores (WRS) at 50, 65, and 80 dB SPL improved significantly by 30.4%, 75%, and 78.2%, respectively, after implantation with the investigational direct acoustic cochlear implant compared with the preoperative unaided condition. The difficulty in hearing, measured by the Abbreviated Profile of Hearing Aid Benefit, decreased by 27% after implantation with the investigational direct acoustic cochlear implant. CONCLUSION Patients with moderate-to-severe mixed hearing loss because of otosclerosis can benefit substantially using the Codacs investigational device.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To investigate objective and subjective effects of an adjunctive contralateral routing of signal (CROS) device at the untreated ear in patients with a unilateral cochlear implant (CI). Design: Prospective study of 10 adult experienced unilateral CI users with bilateral severe-to-profound hearing loss. Speech in noise reception (SNR) and sound localization were measured with and without the additional CROS device. SNR was measured by applying speech signals at the untreated/CROS side while noise signals came from the front (S90N0). For S0N90, signal sources were switched. Sound localization was measured in a 12-loudspeaker full circle setup. To evaluate the subjective benefit, patients tried the device for 2 weeks at home, then filled out the abbreviated Speech, Spatial and Qualities of Hearing Scale as well as the Bern benefit in single-sided deafness questionnaires. Results: In the setting S90N0, all patients showed a highly significant SNR improvement when wearing the additional CROS device (mean 6.4 dB, p < 0.001). In the unfavorable setting S0N90, only a minor deterioration of speech understanding was noted (mean -0.66 dB, p = 0.54). Sound localization did not improve substantially with CROS. In the two questionnaires, 12 of 14 items showed an improvement in mean values, but none of them was statistically significant. Conclusion: Patients with unilateral CI benefit from a contralateral CROS device, particularly in a noisy environment, when speech comes from the CROS ear side. © 2014 S. Karger AG, Basel.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES Sensorineural hearing loss from sound overexposure has a considerable prevalence. Identification of sound hazards is crucial, as prevention, due to a lack of definitive therapies, is the sole alternative to hearing aids. One subjectively loud, yet little studied, potential sound hazard is movie theaters. This study uses smart phones to evaluate their applicability as a widely available, validated sound pressure level (SPL) meter. Therefore, this study measures sound levels in movie theaters to determine whether sound levels exceed safe occupational noise exposure limits and whether sound levels in movie theaters differ as a function of movie, movie theater, presentation time, and seat location within the theater. DESIGN Six smart phones with an SPL meter software application were calibrated with a precision SPL meter and validated as an SPL meter. Additionally, three different smart phone generations were measured in comparison to an integrating SPL meter. Two different movies, an action movie and a children's movie, were measured six times each in 10 different venues (n = 117). To maximize representativeness, movies were selected focusing on large release productions with probable high attendance. Movie theaters were selected in the San Francisco, CA, area based on whether they screened both chosen movies and to represent the largest variety of theater proprietors. Measurements were analyzed in regard to differences between theaters, location within the theater, movie, as well as presentation time and day as indirect indicator of film attendance. RESULTS The smart phone measurements demonstrated high accuracy and reliability. Overall, sound levels in movie theaters do not exceed safe exposure limits by occupational standards. Sound levels vary significantly across theaters and demonstrated statistically significant higher sound levels and exposures in the action movie compared to the children's movie. Sound levels decrease with distance from the screen. However, no influence on time of day or day of the week as indirect indicator of film attendance could be found. CONCLUSIONS Calibrated smart phones with an appropriate software application as used in this study can be utilized as a validated SPL meter. Because of the wide availability, smart phones in combination with the software application can provide high quantity recreational sound exposure measurements, which can facilitate the identification of potential noise hazards. Sound levels in movie theaters decrease with distance to the screen, but do not exceed safe occupational noise exposure limits. Additionally, there are significant differences in sound levels across movie theaters and movies, but not in presentation time.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the speech intelligibility in noise with a new cochlear implant (CI) processor that uses a pinna effect imitating directional microphone system. STUDY DESIGN Prospective experimental study. SETTING Tertiary referral center. PATIENTS Ten experienced, unilateral CI recipients with bilateral severe-to-profound hearing loss. INTERVENTION All participants performed speech in noise tests with the Opus 2 processor (omnidirectional microphone mode only) and the newer Sonnet processor (omnidirectional and directional microphone mode). MAIN OUTCOME MEASURE The speech reception threshold (SRT) in noise was measured in four spatial settings. The test sentences were always presented from the front. The noise was arriving either from the front (S0N0), the ipsilateral side of the CI (S0NIL), the contralateral side of the CI (S0NCL), or the back (S0N180). RESULTS The directional mode improved the SRTs by 3.6 dB (p < 0.01), 2.2 dB (p < 0.01), and 1.3 dB (p < 0.05) in the S0N180, S0NIL, and S0NCL situations, when compared with the Sonnet in the omnidirectional mode. There was no statistically significant difference in the S0N0 situation. No differences between the Opus 2 and the Sonnet in the omnidirectional mode were observed. CONCLUSION Speech intelligibility with the Sonnet system was statistically different to speech recognition with the Opus 2 system suggesting that CI users might profit from the pinna effect imitating directionality mode in noisy environments.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Für Patienten an der Hämodialyse ist nach Versagen der klassischen arterio-venösen Fisteln oder Shunts ein direkter Gefässzugang mittels Katheter lebensnotwendig. Permanente zentralvenöse Katheter penetrieren die Hals- und Thoraxweichteile und die Haut ohne rigide Befestigung. Die Infektionsrate ist hoch und führt oft zur Explantation. Knochenverankerte Hörgeräte sind zur Behandlung bei Schalleitungsschwerhörigkeit etabliert. Das Implantat sitzt fest im Felsenbein und der Aufsatz penetriert die Haut. Schwere Infektionen, die eine Explantation nötig machen, sind sehr selten. Wir nehmen an, dass einer der Hauptgründe für die tiefe Komplikationsrate die starke Befestigung des Implantats am Knochen ist, wodurch die Hautbewegungen relativ zum Knochen minimiert werden. Basierend auf den Erfahrungen mit implantierten Hörsystemen haben wir einen perkutanen knochenverankerten Hämodialysezugang im Bereich des Felsenbeins als vorteilhafte Alternative zum herkömmlichen zentralvenösen Katheterzugang entwickelt. Dabei wurde die Felsenbeinanatomie und Knochendicke zur Lokalisierung des idealen Implantationsortes untersucht; die Schraubenstabilität im Knochen getestet; ein Titanimplantat inklusive Ventile und Katheter, sowie chirurgische Instrumente zur sicheren Implantation entwickelt. Der knochenverankerte Hämodialysezugang wurde auf Flussrate, Dichtigkeit und Reinigung getestet; die Platzierung des Katheters mittels Seldingertechnik in die V. jugularis interna über eine Halsinzision festgelegt. Die Resultate unserer Arbeit zeigen die technische Machbarkeit eines im Felsenbein verankerten neuartigen Hämodialysezuganges und bilden die Grundlage einer inzwischen bewilligten klinischen Pilotstudie.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

CONCLUSION Bone conduction implants are useful in patients with conductive and mixed hearing loss for whom conventional surgery or hearing aids are no longer an option. They may also be used in patients affected by single-sided deafness. OBJECTIVES To establish a consensus on the quality standards required for centers willing to create a bone conduction implant program. METHOD To ensure a consistently high level of service and to provide patients with the best possible solution the members of the HEARRING network have established a set of quality standards for bone conduction implants. These standards constitute a realistic minimum attainable by all implant clinics and should be employed alongside current best practice guidelines. RESULTS Fifteen items are thoroughly analyzed. They include team structure, accommodation and clinical facilities, selection criteria, evaluation process, complete preoperative and surgical information, postoperative fitting and assessment, follow-up, device failure, clinical management, transfer of care and patient complaints.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Inner ear pathologies are associated with major morbidity and loss of life quality in affected patients. In many of these conditions, production of reactive oxygen-species (ROS) is thought to be a key pathological mechanism. While the sources of ROS are complex (including for example mitochondria), there is increasing evidence that activation of NOX enzymes, in particular NOX3, plays a key role. NOX3 is a multi-subunit NADPH oxidase, functionally and structurally closely related to NOX1 and NOX2. In both the vestibular and the cochlear compartments of the inner ear, high levels of NOX3 mRNA are expressed. In NOX3 mutant mice, the vestibular function is perturbed due to a lack of otoconia, while only minor alterations of hearing have been documented. However, there is increasing evidence that activation of NOX3 through drugs, noise and probably also aging, leads to hearing loss. Thus, NOX3 is an interesting target to treat and prevent inner ear pathologies and a few first animal models based on drug - or molecular therapy have been reported. So far however, there are no specific NOX3 inhibitors with a documented penetration into the inner ear. Nevertheless, certain antioxidants and non-specific NOX inhibitors diminish hearing loss in animal models. Development of small molecules inhibitors or molecular strategies against NOX3 could improve specificity and efficiency of redox-targeted treatments. In this review, we will discuss arguments for the involvement of NOX3 in inner ear pathologies and therapeutic approaches to target NOX3 activity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La hipoacusia se define como la disminución de la percepción auditiva, la cual constituye la vía habitual para la adquisición el lenguaje. Se trata de un problema relevante en la infancia temprana, dado que el logro de capacidades y habilidades intelectuales y sociales están ligados a un desarrollo adecuado de la audición como principal vía de aprendizaje. La audición, junto con el resto de los sentidos permite el establecer relaciones sociales y del individuo con su entorno. Es uno de los principales procesos fisiológicos que posibilita a los niños el aprendizaje, siendo de suma importancia para el desarrollo del pensamiento. Por ello es importante analizar las diferentes aristas que intervienen en la prevención, promoción y atención primaria y secundaria de dicha afección. A continuación analizaremos el Programa Nacional de Detección Temprana de Hipoacusias (su legislación, gestión y funcionalización), la importancia de una adecuada información a los padres o responsables del niño hipoacúsico, la perspectiva de la cultura sorda y la perspectiva de la oralización de pacientes sordos mediante el implante coclear en la infancia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La Directiva 2003/10/CE del Parlamento Europeo y del Consejo, del 6 de febrero de 2003, específica con arreglo al apartado 1 del artículo 16 de la Directiva 89/391/CEE las disposiciones mínimas de seguridad y de salud relativas a la exposición de los trabajadores a los riesgos derivados de los agentes físicos (ruido). En la industria musical, y en concreto en los músicos de orquesta, una exposición de más de ocho horas al día a un nivel de presión sonora de 80dB(A) o más es algo muy común. Esta situación puede causar a los trabajadores daños auditivos como la hiperacusia, hipoacusia, tinitus o ruptura de la membrana basilar entre otros. Esto significa que deben tomarse medidas para implementar las regulaciones de la forma más razonable posible para que la interpretación del músico, la dinámica y el concepto musical que se quiere transmitir al público se vea lo menos afectada posible. Para reducir la carga auditiva de los músicos de orquesta frente a fuertes impactos sonoros provenientes de los instrumentos vecinos, se está investigando sobre el uso de unos paneles acústicos que colocados en puntos estratégicos de la orquesta pueden llegar a reducir el impacto sonoro sobre el oído hasta 20dB. Los instrumentos de viento metal y de percusión son los responsables de la mayor emisión de presión sonora. Para proteger el oído de los músicos frente a estos impactos, se colocan los paneles en forma de barrera entre dichos instrumentos y los músicos colocados frente a ellos. De esta forma se protege el oído de los músicos más afectados. Para ver el efecto práctico que producen estos paneles en un conjunto orquestal, se realizan varias grabaciones en los ensayos y conciertos de varias orquestas. Los micrófonos se sitúan a la altura del oído y a una distancia de no más de 10cm de la oreja de varios de los músicos más afectados y de los músicos responsables de la fuerte emisión sonora. De este modo se puede hacer una comparación de los niveles de presión sonora que percibe cada músico y evaluar las diferencias de nivel existentes entre ambos. Así mismo se utilizan configuraciones variables de los paneles para comparar las diferencias de presión sonora que existen entre las distintas posibilidades de colocarlos y decidir así sobre la mejor ubicación y configuración de los mismos. A continuación, una vez obtenidos las muestras de audio y los diferentes archivos de datos medidos con un analizador de audio en distintas posiciones de la orquesta, todo ello se calibra y analiza utilizando un programa desarrollado en Matlab, para evaluar el efecto de los paneles sobre la percepción auditiva de los músicos, haciendo especial hincapié en el análisis de las diferencias de nivel de presión sonora (SPL). Mediante el cálculo de la envolvente de las diferencias de nivel, se evalúa de un modo estadístico el efecto de atenuación de los paneles acústicos en los músicos de orquesta. El método está basado en la probabilidad estadística de varias muestras musicales ya que al tratarse de música tocada en directo, la dinámica y la sincronización entre los músicos varía según el momento en que se toque. Estos factores junto con el hecho de que la partitura de cada músico es diferente dificulta la comparación entre dos señales grabadas en diferentes puntos de la orquesta. Se necesita por lo tanto de varias muestras musicales para evaluar el efecto de atenuación de los paneles en las distintas configuraciones mencionadas anteriormente. El estudio completo del efecto de los paneles como entorno que influye en los músicos de orquesta cuando están sobre el escenario, tiene como objetivo la mejora de sus condiciones de trabajo. Abstract For several years, the European Union has been adopting many laws and regulations to protect and give more security to people who are exposed to some risk in their job. Being exposed to a loud sound pressure level during many hours in the job runs the risk of hearing damage. Particularly in the field of music, the ear is the most important working tool. Not taking care of the ear can cause some damage such as hearing loss, tinnitus, hyperacusis, diplacusis, etc. This could have an impact on the efficiency and satisfaction of the musicians when they are playing, which could also cause stress problems. Orchestra musicians, as many other workers in this sector, are usually exposed to a sound level of 80dB(A) or more during more than eight hours per day. It means that they must satisfy the law and their legal obligations to avoid health problems proceeding from their job. Putting into practice the new regulations is a challenge for orchestras. They must make sure that the repertoire, with its dynamic, balance and feeling, is not affected by the reduction of sound levels imposed by the law. This study tries to investigate the benefits and disadvantages of using shields as a hearing protector during rehearsals and orchestral concerts.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hearing loss is most often the result of hair-cell degeneration due to genetic abnormalities or ototoxic and traumatic insults. In the postembryonic and adult mammalian auditory sensory epithelium, the organ of Corti, no hair-cell regeneration has ever been observed. However, nonmammalian hair-cell epithelia are capable of regenerating sensory hair cells as a consequence of nonsensory supporting-cell proliferation. The supporting cells of the organ of Corti are highly specialized, terminally differentiated cell types that apparently are incapable of proliferation. At the molecular level terminally differentiated cells have been shown to express high levels of cell-cycle inhibitors, in particular, cyclin-dependent kinase inhibitors [Parker, S. B., et al. (1995) Science 267, 1024–1027], which are thought to be responsible for preventing these cells from reentering the cell cycle. Here we report that the cyclin-dependent kinase inhibitor p27Kip1 is selectively expressed in the supporting-cell population of the organ of Corti. Effects of p27Kip1-gene disruption include ongoing cell proliferation in postnatal and adult mouse organ of Corti at time points well after mitosis normally has ceased during embryonic development. This suggests that release from p27Kip1-induced cell-cycle arrest is sufficient to allow supporting-cell proliferation to occur. This finding may provide an important pathway for inducing hair-cell regeneration in the mammalian hearing organ.