976 resultados para Frequency-dependent parameters
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this work was to characterize the distribution of myofibers in the gluteus medius muscle of inactive horses of the Brasileiro de Hipismo (BH) breed at different ages by means of histochemical analyses, according to sex and depth of the biopsy. A total of 78 inactive horses (9 castrated males, 35 stallions, and 34 females) of the BH breed, aged 1 to 4 years, were used. A percutaneous muscle biopsy was obtained with a 6.0-mm Bergstrom-type needle, which allowed the removal of muscle fragments at depths of 20 and 60 mm. Myofiber types were determined based on myofibrillar adenosine triphosphatase (mATPase) and nicotinamide dinucleotide tetrazolium reductase (NADH-TR) techniques. Morphometry of the fibers was determined based on cross-sectional area (CSA), mean frequency (F), and relative cross-sectional area (RCSA). The current study demonstrated that BH horses 3 and 4 years of age show a greater percentage of, and area occupied by, type IIA fibers and lower percentage of type IIX fibers in the gluteus medius muscle compared with horses 1 and 2 years of age. No difference was found between sexes in the frequency of and area occupied by the different fiber types at any of the depths and ages studied. In this study, females showed a greater CSA for all fibers in comparison with males, at 1 year of age. The results of the current study indicate that the gluteus medius muscle of inactive BH horses shows modifications in its structural and biochemical composition during the growth of the animals, leading to a better oxidative capacity.
Resumo:
A method of determining spectral parameters p (slope of the phase PSD) and T (phase PSD at 1 Hz) and hence tracking error variance in a GPS receiver PLL from just amplitude and phase scintillation indices and an estimated value of the Fresnel frequency has been previously presented. Here this method is validated using 50 Hz GPS phase and amplitude data from high latitude receivers in northern Norway and Svalbard. This has been done both using (1) a Fresnel frequency estimated using the amplitude PSD (in order to check the accuracy of the method) and (2) a constant assumed value of Fresnel frequency for the data set, convenient for the situation when contemporaneous phase PSDs are not available. Both of the spectral parameters (p, T) calculated using this method are in quite good agreement with those obtained by direct measurements of the phase spectrum as are tracking jitter variances determined for GPS receiver PLLs using these values. For the Svalbard data set, a significant difference in the scintillation level observed on the paths from different satellites received simultaneously was noted. Then, it is shown that the accuracy of relative GPS positioning can be improved by use of the tracking jitter variance in weighting the measurements from each satellite used in the positioning estimation. This has significant advantages for scintillation mitigation, particularly since the method can be accomplished utilizing only time domain measurements thus obviating the need for the phase PSDs in order to extract the spectral parameters required for tracking jitter determination.
Resumo:
An oxovanadium-salen complex (NAP-ethylene-bis(salicylidenciminato) oxovanadium) thin film deposited on a graphite-polyurethane electrode was investigated with regard to its potential use for detection of L-dopa in flow injection system. The oxovanadium(IV)/oxovanadium(V) redox couple of the modified electrode was found to mediate the L-dopa oxidation before its use in the FIA system. Experimental parameters, such as pH of the carrier solution, flow rate, sample volume injection and probable interferents were investigated. Under the optimized FIA conditions, the amperometric signal was linearly dependent on the L-dopa concentration over the range 1.0 x 10(-1) to 1.0 x 10(-4) mol L-1 (I-anodic, mu A) = 0.01 + 0.25 [L-dopa mu mol L-1]) with a detection limit (S/N = 3) of 8.0 x 10(-7) mol L-1 and a sampling frequency of 90 h(-1) was achieved. For a concentration of 1.0 x 10(-5) mol L-1 L-dopa, the R.S.D. of nine consecutive measurements was 3.7%. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
In this paper, a factor referred to as k(f) for linear induction motor end effect analysis is presented. The mathematical model takes into account the longitudinal entry end effect. The entry end effect produces considerable distortion in magnetic field distribution. It is shown how this influence is derived from the machine-developed force that is calculated through the application of the I-D theory. The k(f) factor establishes the relationship between the longitudinal end effect and machine parameters, mainly the number of magnetic poles, secondary resistivity, and frequency.
Resumo:
While providing physical and psychological benefits, excessive exercise could be or cause a compulsive behavior, making the individual dependent on it. In a parallel discussion, computerized psychological instruments, for a hand, reflects the development of information technology and your applicability to other areas, but also shows little advance for Psychological Assessment. In this perspective, this study aims to adapt the Exercise Dependence Scale (EDS-R) in two formats (paper-and-pencil and computerized) and evaluate evidence of factorial and convergent validity, and reliability of each version and compare them with each other. It is also proposed to observe the relationship of some bio-demographic (Sex, age, frequency, duration and intensity of practice exercise) and the exercise dependence (DEF). For this purpose, 709 regular physical activity practitioners, selected by procedures non-probabilistic sampling, responded a adapted version of EDS-R, Muscle Appearance Satisfaction Scale (MASS), Body Modification Scale (BMS) and a demographic questionnaire, analyzed through Exploratory Factor Analysis, Cronbach's Alpha and not parametric tests. Both the traditional version and the computer showed a seven factors structure, explaining 57 and 62% of the variance, respectively, and Cronbach's alphas of 0.83 and 0.89. Factors were: (1) intentionality, (2) continuity, (3) tolerance, (4) reduction of other activities, (5) lack of control, (6) abstinence and (7) time spent on exercise. Relationships were observed between the Exercise Dependence and the variables: age, diets, consumption of food supplements and medicines for weight change, desire to do plastic surgery and body satisfaction. We observed also a positive correlation between the DEF and the frequency, duration and intensity of exercise, and the factor "Dependence on exercising" from MASS, indicating convergent validity of the EDS-R. Finally, comparisons between the two formats were equivalent, with few changes: computerized version achieved higher DEF scores. Based on these results, it can be concluded that the EDS-R has factorial and convergent validity, reliability, to measure exerceise dependence on traditional e computerized formats. DEF is related to actions used to body modification and behaviors toward exercise. Finally, it was found equivalence between the formats, especially in psychometric parameters, thus suggesting feasibility of a computerized assessment. However, it was observed that the computerized data has sample recruiting strategies more limited
Resumo:
The search for better performance in the structural systems has been taken to more refined models, involving the analysis of a growing number of details, which should be correctly formulated aiming at defining a representative model of the real system. Representative models demand a great detailing of the project and search for new techniques of evaluation and analysis. Model updating is one of this technologies, it can be used to improve the predictive capabilities of computer-based models. This paper presents a FRF-based finite element model updating procedure whose the updating variables are physical parameters of the model. It includes the damping effects in the updating procedure assuming proportional and none proportional damping mechanism. The updating parameters are defined at an element level or macro regions of the model. So, the parameters are adjusted locally, facilitating the physical interpretation of the adjusting of the model. Different tests for simulated and experimental data are discussed aiming at defining the characteristics and potentialities of the methodology.
Resumo:
This paper investigates the feasibility of using an energy harvesting device tuned such that its natural frequency coincides with higher harmonics of the input to capture energy from walking or running human motion more efficiently. The paper starts by reviewing the concept of a linear resonant generator for a tonal frequency input and then derives an expression for the power harvested for an input with several harmonics. The amount of power harvested is estimated numerically using measured data from human subjects. Assuming that the input is periodic, the signal is reconstructed using a Fourier series before being used in the simulation. It is found that although the power output depends on the input frequency, the choice of tuning the natural frequency of the device to coincide with a particular higher harmonic is restricted by the amount of damping that is needed to maximize the amount of power harvested, as well as to comply with the size limit of the device. It is also found that it is not feasible to tune the device to match the first few harmonics when the size of the device is small, because a large amount of damping is required to limit the motion of the mass.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Os objetivos do presente estudo foram avaliar a performance das raças Jersey e Holandesa em diferentes condições de pluviosidade (estações seca e chuvosa) através do monitoramento de aspectos relacionados com a mastite subclínica (contagem de células somáticas, isolamento microbiológico, tipo de patógeno isolado), qualidade do leite (lactose, proteína, gordura e sólidos totais) e produção (media da produção de leite) de ambas as raças. O estudo foi conduzido em propriedade leiteira localizada no estado de São Paulo, Brasil. Oito visitas foram realizadas a propriedade, quatro em período de alta pluviosidade e outro em período de baixa pluviosidade. Amostras de leite foram colhidas de todos os animais para contagem eletrônica de células somáticas e determinação dos principais componentes do leite (proteína, gordura, sólidos totais, lactose). Gordura, proteína, sólidos totais e produção leiteira foram influenciadas tanto pela raça como pela estação, apresentando tendências similares para ambas raças em ambas estações. A contagem de células somáticas (CCS) apresentou resultados similares para ambas as raças. Vacas holandesas com infecção intramamária (IIM) apresentaram um maior aumento na CCS quando comparadas as vacas Jersey (P<0.001). Na estação seca, 53 animais tiveram IIM em pelo menos um mês do estudo. Destes, 32 eram da raça Holandesa e 21 da raça Jersey. Na estação chuvosa, 65 animais possuíram infecção intramamária, dos quais 43 eram da raça Holandesa e 22 da raça Jersey. A frequência de casos de IIM foi maior na estação chuvosa em comparação à estação seca. Vacas Jersey apresentaram uma menor chance de desenvolver sinais e sintomas de IIM em relação às vacas holandesas na estação chuvosa (razão de chances=0.52). O maior numero de casos de IIM na estação chuvosa pode ter contribuído para uma menor taxa de lactose no leite para ambas as raças, sendo que esta pode ser considerada como um indicador do status de IIM. Existiu uma prevalência de patógenos contagiosos durante todo o experimento. O modelo estatístico aplicado mostrou que patógenos ambientais foram mais frequentemente isolados da raça Jersey, independentemente do período do estudo. Aparentemente existem diferenças na resposta imune das raças Jersey e Holandesa.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
O objetivo do presente estudo foi desenvolver um snorquel (SNQ) de baixo custo para mensuração de parâmetros cardiorrespiratórios em natação. Para isso, a máscara do analisador de gases VO2000 (MASC) foi adaptada a um SNQ desenvolvido artesanalmente com espaço morto de 250ml. Oito participantes foram submetidos a dois testes incrementais (TI) em cicloergômetro utilizando a MASC e o SNQ. Os TI foram realizados até a exaustão voluntária e foram compostos por estágios de 3min com carga inicial e incrementos de 35W. em ambas as situações, amostras gasosas foram coletadas em intervalos de 10s para determinação dos volumes de oxigênio (VO2), gás carbônico (VCO2), ventilatório (VE) e mensuração da freqüência cardíaca (FC). A comparação dos parâmetros cardiorrespiratórios (VO2, VE, VCO2 e FC) mensurados com o SNQ e a MASC foi realizada com o teste t de Student para amostras dependentes, enquanto que o teste de correlação de Pearson e a análise gráfica de Bland e Altman foram utilizados para verificar as associações e concordância entre parâmetros. em todos os casos, o nível de significância foi de P < 0,05. A adequação das equações de correção para os valores provenientes do SNQ foi verificada pelos erros sistemáticos (bias), aleatórios (precisão) e acurácia (ac). Não foram observadas diferenças significativas entre os valores de VO2, VCO2 e FC obtidos com a MASC e SNQ. Os valores de VE mensurados com o SNQ foram significativamente superiores aos obtidos com a MASC. No entanto, todos os parâmetros apresentaram elevada concordância e coeficiente de correlação (0,88 a 0,97). Além disso, foram verificados reduzidos valores de bias (VO2 = 0,11L/min; VE = 4,11L/min; VCO2 = 0,54L/min; 8,87bpm), precisão (VO2 = 0,24L/min; VE = 11,02L/ min; VCO2 = 0,18L/min; 7,42bpm) e ac (VO2 = 0,27L/min; VE = 11,76L/min; VCO2 = 0,56L/min; 11,56bpm). Desse modo, pode-se concluir que o SNQ desenvolvido neste estudo possibilita a mensuração válida de parâmetros cardiorrespiratórios em natação.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)