646 resultados para Fracturação hidráulica
Resumo:
Most of the hydraulic turbines that are running in the world are the Francis type, because they are able to fit a wide range of head and flow. We also can declare that most of the installed hydraulic energy up to this date is generated by this type of turbine. On the other hand, if we pay attention to mechanical details of a Francis turbine we will see that among the three most used types it is the one that presents the more complex design. And, the simplest one is the Pelton type, whereas the Kaplan is the one less utilized. This work aims to develop the hydrodynamic calculation of a Francis turbine as well as to obtain its assembly drawing and 3D modeling drawing. In this way all details must be shown therefore needing a complete knowledge about this issue. Both 2D and 3D drawings help much if one wants the machine to be running in its power house. It is well noted that most of the entities that design and manufacture the Francis turbines are not brazilian. In this way the more we study how to design this kind of machine the more is our contribution to our country in order to conquer technology and manufacture Francis turbines
Resumo:
The treatment of domestic and industrial effluents through Wastewater Treatment Plants (WTPs) generates a residue termed sewage sludge, rich in organic matter, high-volume, occasionally containing pathogens and heavy metals. The sludge generation can minimize the benefits brought by the treatment of sewage, because this residue does not always receive appropriate treatment before final disposal. The disposal is another problem related to sludge. Landfills generally does not have physical space and alternatives such as the use in agriculture requires an intense treatment that could be in many cases operational or economic unfeasible. The objective of this work is the theoretical research about the processes of stabilization of the sludge by anaerobic digestion and the methanogenic activity during the process. Through analysis of each step and contemplating each relevant factor in anaerobic digestion process in order to optimize them, we proposed a theoretical model of reactors capable of stabilize the sludge, reduce its volume and eliminate pathogens. The obtained configuration consists of two anaerobic reactors connected in series. The first one operates in the range mesophilic temperature (35 ° C) and has higher hydraulic retention time (25 days) working primarily in the stabilization of organic matter present in the sludge and producing biogas, whereas the second one operates in the thermophilic range (55 ° C) in order to eliminate pathogens, and to reduce the volume. The hydraulic retention time in the second reactor is lower (10 days). Both mesophilic and thermophilic processes were efficient in what was proposed, promoting the stabilization of organic matter present in the sludge and significant reduction of pathogens. As a final step with the sludge previously digested, it is indicated a final dehydration... (Complete abstract click electronic access below)
Resumo:
The term model refers to any representation of a real system. The use of models in Hydrogeology can be valuable predictive tools for management of groundwater resources. The numeric models of groundwater flow, object of this study, consist on a set of differential equations that describe the water flow in the porous medium. In this context, numeric simulations were made for a sub-basin located at Cara Preta farm – Santa Rita do Passa Quatro – SP. The aquifer at the local is composed by rocks of Pirambóia Formation, which is part of Guarani Aquifer System. It was developed a conceptual model from previous studies in the area, and from that, simulations were made through the software Visual Modflow®. The conceptual model established previously was considered consistent through the results of simulation.
Resumo:
The purpose of this work is to study the theme “infiltration trenches” in some of its main aspects, such as sizing methods and parameters related to this, in order to subsidize the installation of these structures in the urban area of Rio Claro/SP. For purposes of sizing, the “rain-envelope method” was used for its simplicity and direct application from the local characterization data and the IDF (intensity-duration-frequency) curve data. The method bases on the determination of the tributary volume of input and output device. The curve of values accumulated over time of the volumes tributaries to the device, which is built on the flow rates obtained from the local IDF curve, is compared with the value curve of his effluent volumes determined from the flow characteristics obtained from the infiltration soil. The maximum difference between the curves is the volume sizing. Five locations were chosen in the urban area of Rio Claro for implementation of these devices, considering the soil type, hydraulic conductivity of each area and lot size according to the Master Plan of Rio Claro. This work also presented an estimated reduction of the runoff in urban lots by using infiltration trenches.
Resumo:
Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Geociências e Meio Ambiente - IGCE
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
The aim of this study was to compare the hydraulic conductance in human dentin disks, where 1, 2 or 3 layers of adhesive Single Bond 2(SB2) and Single Bond Universal(SBU) were applied. 84 1 mm. thick(+/- 0.1 mm.) dentin disks were fabricated. Samples were divided into 7 groups (n = 12) Control (without adhesive), A1: one layer of SB2, A2: two layers SB2, A3: three layers SB2, B1: one layer SBU, B2: two layers of SBU, B3: three layers of SBU. The results as averages for the hydraulic conductance of each separate group were: Control (0.0363), A1 (0.0206), A2 (0.0070), A3 (0.0061), B1 (0.0161), B2 (0.0062), B3(0.0056) expressed µl/min.cm2. There is statistically significant difference CH, between the control group and those samples that one coat was applied (p = 0.000) and also between the application of one and two layers (p = 0.000). No difference between the two adhesives (p = 0.434). Summary Key words: Dentin, conductance, difussion adhesive layers.
Resumo:
Pós-graduação em Microbiologia Agropecuária - FCAV
Resumo:
Water and soil pollution caused by the waste from the swine production causes severe environmental impacts in producing areas. An efficient alternative to reduce these impacts can be the use of high-rate anaerobic reactors. In this work, it was evaluated the effect of the swine wastewater with total suspended solids concentrations around 6.000 mg.L-1 in the anaerobic baffled reactor with three compartments. The volume of the first compartment was 210 L and of the second and third ones of 160 L. The anaerobic baffled reactor was submitted at hydraulic detention times of 56, 28 and 18 hours and to organic load rates of 5.0 to 10.1 g total COD (L.d)(-1). The highest total COD removals, of 42 to 68%, and volumetric methane productions, of 0.261 to 0.454 L CH4 (L reactor d)(-1), occurred in the second compartment.
Resumo:
Pós-graduação em Engenharia Civil - FEIS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
O objetivo do presente trabalho foi avaliar a eficiência do tratamento da manipueira de extração de fécula de mandioca, em separado da água de lavagem das raízes, através de biodigestores anaeróbicos de fluxo ascendente, com separação das fases, sem controle de temperatura ou adição de produtos químicos e, avaliar sua adequabilidade, através de suas características físicas e químicas para lançamento em corpo receptor, sistema público coletor de esgotos ou, aplicação em processod e fertirrigação. Depois dos reatores estabilizados, foram realizados ensaios variando a vazão de alimentação com 8,0; 12,0 e 16,0 L/d, correspondentes a um tempo de retenção hidráulica de 8,17; 5,44 e 4,08 dias, respectivamente. Os melhores resultados para redução da carga orgânica foram obtidos com os tempos de retenção hidráulica (TRH) de 8,17 e 5,44 dias com eficiências médias de 89,8% e 80,9%, respectivamente. As características físicas e químicas dos efluentes tratados foram comparadas com os valores estabelecidos na legislação estadual, federal e, com os parâmetros utilizados pelo orgão ambiental fiscalizador. Os resultados obtidos mostraram que o efluente tratado atende parcialmente aos requisitos legais para o lançamento em corpos receptores, devido ao teor elevado de nitrogênio amoniacal. Por outro lado, foram atendidos integralmente os requisitos legais para o lançamento na rede pública coletora de esgotos. O efluente tratado não atendeu às recomendações requeridas pelo orgão ambiental fiscalizador para a sua disposição através do processo de fertirrigação devido aos teores elevados de ferro (Fe) e de fluoretos (F). Considerando os resultados obtidos, concluímos que, devido à simplicidade do sistema utilizado, com a implantação de melhorias como um pós-tratamento, poderiam ser atingidos os parâmetros que atenderiam integralmente a legislação.
Resumo:
The aim of this paper was to evaluate the efficiency of the treatment of cassava wastewater, separately from the root washing water, by means of ascending flux anaerobic digesters, with separation of the phases, without temperature control or addition of chemical products and to evaluate its suitability by means of its physical and chemical characteristics for throwing in receiving body, public sewage system or application in fertilization and irrigation. After reactors had been stabilized, essays were conducted varying feeding flow with 8.0, 12.0 and 16.0 Ld-1 corresponding to a hydraulic retention time of 8.17, 5.44 and 4.08 days, respectively. The best reduction for organic load reduction were obtained with hydraulic retention times (HRT) of 8.17 and 5.44 days with mean efficiencies of 89.8 and 90.9%, respectively.