994 resultados para ENZYME-CATALYZED REACTIONS
Resumo:
The iron(III) complexes [H(EtOH)][FeCl2(L)(2)] (1), [H(2)bipy](1/2)[FeCl2(L)(2)].DMF (2) and [FeCl2(L)(2,2'-bipy)] (3) (L = 3-amino-2-pyrazinecarboxylate; H(2)bipy = doubly protonated 4,4'-bipyridine; 2,2'-bipy = 2,2'-bipyridine, DMF = dimethylformamide) have been synthesized and fully characterized by IR, elemental and single-crystal X-ray diffraction analyses, as well as by electrochemical methods. Complexes 1 and 2 have similar mononuclear structures containing different guest molecules (protonated ethanol for 1 and doubly protonated 4,4'-bipyridine for 2) in their lattices, whereas the complex 3 has one 3-amino-2-pyrazinecarboxylate and a 2,2'-bipyridine ligand. They show a high catalytic activity for the low power (10 W) solvent-free microwave assisted peroxidative oxidation of 1-phenylethanol, leading, in the presence of TEMPO, to quantitative yields of acetophenone [TOFs up to 8.1 x 10(3) h(-1), (3)] after 1 h. Moreover, the catalysts are of easy recovery and reused, at least for four consecutive cycles, maintaining 83 % of the initial activity and concomitant rather high selectivity. 3-Amino-2-pyrazinecarboxylic acid is used to synthesize three new iron(III) complexes which act as heterogeneous catalysts for the solvent-free microwave-assisted peroxidative oxidation of 1-phenylethanol.
Resumo:
Hydatid disease in tropical areas poses a serious diagnostic problem due to the high frequence of cross-reactivity with other endemic helminthic infections. The enzyme-linked-immunosorbent assay (ELISA) and the double diffusion arc 5 showed respectively a sensitivity of 73% and 57% and a specificity of 84-95% and 100%. However, the specificity of ELISA was greatly increased by using ovine serum and phosphorylcholine in the diluent buffer. The hydatic antigen obtained from ovine cyst fluid showed three main protein bands of 64,58 and 30 KDa using SDS PAGE and immunoblotting. Sera from patients with onchocerciasis, cysticercosis, toxocariasis and Strongyloides infection cross-reacted with the 64 and 58 KDa bands by immunoblotting. However, none of the analyzed sera recognized the 30 KDa band, that seems to be specific in this assay. The immunoblotting showed a sensitivity of 80% and a specificity of 100% when used to recognize the 30 KDa band.
Resumo:
A new serological test, the gelatin particle agglutination test (GPAT), was used for the serodiagnosis of schistosomiasis mansoni. This technique showed the sensitivity (90.6%) and specificity (97.8%) close to those of enzyme-linked immunosorbent assay. The GPAT can be easily and rapidly performed without specialized equipment, by using lyophilized antigen-coated gelatin particles. The test also seems to be useful for mass screening of Schistosoma infection in field conditions.
Resumo:
Dissertation presented to obtain the Doctorate degree (Ph.D.) in Biology at Instituto de Tecnologia Química e Biológica da Universidade Nova de Lisboa
Resumo:
A dot-enzyme-linked immunosorbent assay (Dot-ELISA) for pneumococcal antigen detection was standardized in view of the need for a rapid and accurate immunodiagnosis of acute pneumococcal pneumonia. A total of 442 pleural fluid effusion samples (PFES) from children with clinical and laboratory diagnoses of acute bacterial pneumonia, plus 38 control PFES from tuberculosis patients and 20 negative control serum samples from healthy children were evaluated by Dot-ELISA. The samples were previously treated with 0.1 M EDTA pH 7.5 at 90°C for 10 min and dotted on nitrocellulose membrane. Pneumococcal omniserum diluted at 1:200 was employed in this assay for antigen detection. When compared with standard bacterial culture, counterimmunoelectrophoresis and latex agglutination techniques, the Dot-ELISA results showed relative indices of 0.940 to sensitivity, 0.830 to specificity and 0.760 to agreement. Pneumococcal omniserum proved to be an optimal polyvalent antiserum for the detection of pneumococcal antigen by Dot-ELISA. Dot-ELISA proved to be a practical alternative technique for the diagnosis of pneumococcal pneumonia.
Resumo:
The sensitivity and specificity of an enzyme-linked immunosorbent assay (ELISA) for the detection of circulating antigens from toxic components of Tityus serrulatus scorpion venom was determined in patients stung by T. serrulatus before antivenom administration. Thirty-seven patients were classified as mild cases and 19 as moderate or severe cases. The control absorbance in the venom assay was provided by serum samples from 100 individuals of same socioeconomic group and geographical area who had never been stung by scorpions or treated with horse antisera. The negative cutoff value (mean + 2 SD) corresponded to a venom concentration of 4.8 ng/ml. Three out of the 100 normal sera were positive, resulting in a specificity of 97%. The sensitivity of the ELISA when all cases of scorpion sting were included was 39.3%. When mild cases were excluded, the sensitivity increased to 94.7%. This study showed that this ELISA can be used for the detection of circulating venom toxic antigens in patients with systemic manifestations following. T. serrulatus sting but cannot be used for clinical studies in mild cases of envenoming since the test does not discriminate mild cases from control patients.
Resumo:
A Dot enzyme-linked immunosorbent assay (Dot-ELISA) was standardized and evaluated for the serodiagnosis of human toxoplasmosis. Out of 538 serum samples tested by the immunofluorescence test for toxoplasmosis (IFAT-IgG) as reference test, 183 (34%) were positive at cut off 1:16 and 192 (36%) were positive for Dot-ELISA-IgG at cut-off 1:256. For Dot-ELISA, co-positivity was 0.94, co-negativity 0.94 and concordance 0.88 in relation to IFAT-IgG. These results suggest the usefulness of Dot-ELISA (cut-off titer of 1:256) for the serodiagnosis of human toxoplasmosis. The main advantage of this technique is simplicity, positive test can be visually identified (colored precipitate). It does not require a special equipment and it can be used as a qualitative test to screen large numbers of samples or as a quantitative assay to determine end-point titration of individual sera.
Resumo:
An immunoprecipitation technique, ELIEDA (enzyme-linked-immuno-electro-diffusion assay), was evaluated for the diagnosis of Schistosoma mansoni infection with low worm burden. One hundred of serum samples from patients excreting less than 600 eggs per gram of feces (epg), with unrelated diseases and clinically healthy subjects were studied. In patients with egg counts higher than 200 epg, the sensitivities of IgM and IgG ELIEDA were 1.000 and 0.923, respectively, not differing from other Serologic techniques, such as indirect hemaglutination (IHAT), immunofluorescence (IFT) tests and immuno-electrodiffusion assay (IEDA). However in patients with low egg counts (< 100 epg), the IgG ELIEDA provided better results (0.821) than IgM ELIEDA (0.679), showing sensitivity that did not differ from that of IgG IFT (0.929), but lower than that of IgM IFT (0.964). However, its sensivity was higher than that found with IHAT (0.607) and IEDA (0.536). The specificity of IgG ELIEDA was comparable to that of other techniques. The data indicate that IgG ELIEDA might be useful for the diagnosis of slight S. mansoni infections, and the cellulose acetate membrane strips can be stored for further retrospective studies.
Resumo:
A thesis submitted to the University of Innsbruck for the doctor degree in Natural Sciences, Physics and New University of Lisbon for the doctor degree in Physics, Atomic and Molecular Physics
Resumo:
A simple method of rubella antigen production by treatment with sodium desoxycholate for use in enzyme immunoassay (IMT-ELISA) is presented. When this assay was compared with a commercial test (Enzygnost-Rubella, Behring), in the study of 108 sera and 118 filter paper blood samples, 96.9% (219/226) overall agreement and correlation coefficient of 0.90 between absorbances were observed. Seven samples showed discordant results, negative by the commercial kit and positive by our test. Four of those 7 samples were available, being 3 positive by HI.
Resumo:
Concomitant serotypes 1 and 4 infections were detected in a 15-month old female child with community-acquired diarrhoea which lasted 7 days and coursed with moderate dehydration. The evidence for dual rotavirus infection was offered by the following findings: a) enzyme-linked immunosorbent assay (ELISA) positive reactions to both 1 and 4 serotypes; and b) extra-migrating bands at electro-phoresis of RNA in polyacrylamide gel (PAGE). These results suggest that children living under poor sanitation conditions are heavily exposed to rotavirus infections; in addition, the co-circulation of different serotypes in the same setting sustains the current concept that a rotavirus vaccine should be rnultivalent, in order to protect children against the four epidemiologically important rotavirus G serotypes.
Resumo:
Some viruses of the families Retroviridae, such as Human T Lymphotropic Virus (HTLV); Herpesviridae as the Cytomegalovirus (CMV) and Hepadnaviridae such as the Hepatitis B Virus (HBV) are liable to be co-transmitted with the Human Immunodeficiency Virus (HIV). Since prisoners are exposed to several and important risk factors involved in the transmission of HIV and the above mentioned viruses, male inmates from the penitentiary complex of Campinas, SP, Brazil, including HIV + and HIV - ones, were examined for the presence of HTLV-I and/or II antibodies; IgG and IgM anti-CMV antibodies, and the research of the superficial hepatitis B antigen (HBsAg). The presence of anti-HTLV-I and/or II was determined by the Western Blot (WB) technique, whereas IgG and IgM anti-CMV and the search of HBsAg were carried out by the Microparticle Enzyme Immunoassay (MEIA-Abbott Lab).With regard to anti-HTLV-I and/or II, 58.3% (14/24-Number of positive reactions/number of sera examined) were reactive among the anti-HIV positive sera. Conversely, only 12.5% (3/24) among the HIV- negative sera showed positive reactions to HTLV-I and/or II antibodies. When looking for IgG anti-CMV percentages of 97.7% (43/44) and 95% (38/40) were obtained for anti-HIV positive and negative sera, respectively. As to IgM anti-CMV antibodies 11.36% (5/44) and 2.5% (1/40) of reactive sera were found for anti-HIV positive and negative, respectively. The HBsAg was found in 12.8% (5/39) of the sera which were anti-HIV positive.
Resumo:
O instável mas tendencialmente crescente preço dos combustíveis associado a preocupações ambientais cada vez mais enraizadas nas sociedades, têm vindo a despoletar uma maior atenção à procura de combustíveis alternativos. Por outro lado, várias projecções indicam um aumento muito acentuado do consumo energético global no curto prazo, fruto do aumento da população e do nível de industrialização das sociedades. Neste contexto, o biodiesel (ésteres de ácidos gordos) obtido através da transesterificação de triglicerídeos de origem vegetal ou animal, surge como a alternativa “verde” mais viável para utilização em equipamentos de combustão. A reacção de transesterificação é catalisada, por norma com recurso a catalisadores homogéneos alcalinos (NaOH ou KOH). Este tipo de processo, o único actualmente com expressão a nível industrial, apresenta algumas desvantagens que, para além de aumentarem o custo do produto final, contribuem para reduzir a benignidade do mesmo: a impossibilidade de reutilização do catalisador, o aumento do número e complexidade das etapas de separação e a produção de efluentes resultantes das referidas etapas. Com o intuito de minimizar ou eliminar estes problemas, vários catalisadores heterogéneos têm vindo a ser estudados para esta reacção. Apesar de muitos apresentarem resultados promissores, a grande maioria não tem viabilidade para aplicação industrial seja devido ao seu próprio custo, seja devido aos pré-tratamentos necessários à sua utilização. Entre estes catalisadores, o óxido de cálcio é talvez o que apresenta resultados mais promissores. O crescente número de estudos envolvendo este catalisador em detrimento de outros, é por si mesmo prova do potencial do CaO. A realização deste trabalho pretendia atingir os seguintes objectivos principais: • Avaliar a elegibilidade do óxido de cálcio enquanto catalisador da reacção de transesterificação de óleos alimentares usados com metanol; • Avaliar qual a sua influência nas características dos produtos finais; • Avaliar as diferenças de performance entre o óxido de cálcio activado em atmosfera inerte (N2) e em ar, enquanto catalisadores da reacção de transesterificação de óleos alimentares usados com metanol; • Optimizar as condições da reacção com recurso às ferramentas matemáticas disponibilizadas pelo planeamento factorial, através da variação de quatro factores chave de influência: temperatura, tempo, relação metanol / óleo e massa de catalisador utilizado. O CaO utlizado foi obtido a partir de carbonato de cálcio calcinado numa mufla a 750 °C durante 3 h. Foi posteriormente activado a 900 °C durante 2h, em atmosferas diferentes: azoto (CaO-N2) e ar (CaO-Ar). Avaliaram-se algumas propriedades dos catalisadores assim preparados, força básica, concentração de centros activos e áreas específicas, tendo-se obtido uma força básica situada entre 12 e 14 para ambos os catalisadores, uma concentração de centros activos de 0,0698 mmol/g e 0,0629 mmol/g e áreas específicas de 10 m2/g e 11 m2/g respectivamente para o CaO-N2 e CaO-Ar. Efectuou-se a transesterificação, com catálise homogénea, da mistura de óleos usados utilizada neste trabalho com o objectivo de determinar os limites para o teor de FAME’s (abreviatura do Inglês de Fatty Acid Methyl Esters’) que se poderiam obter. Foi este o parâmetro avaliado em cada uma das amostras obtidas por catálise heterogénea. Os planos factoriais realizados tiveram como objectivo maximizar a sua quantidade recorrendo à relação ideal entre tempo de reacção, temperatura, massa de catalisador e quantidade de metanol. Verificou-se que o valor máximo de FAME’s obtidos a partir deste óleo estava situado ligeiramente acima dos 95 % (m/m). Realizaram-se três planos factoriais com cada um dos catalisadores de CaO até à obtenção das condições óptimas para a reacção. Não se verificou influência significativa da relação entre a quantidade de metanol e a massa de óleo na gama de valores estudada, pelo que se fixou o valor deste factor em 35 ml de metanol / 85g de óleo (relação molar aproximada de 8:1). Verificou-se a elegibilidade do CaO enquanto catalisador para a reacção estudada, não se tendo observado diferenças significativas entre a performance do CaO-N2 e do CaO-Ar. Identificaram-se as condições óptimas para a reacção como sendo os valores de 59 °C para a temperatura, 3h para o tempo e 1,4 % de massa de catalisador relativamente à massa de óleo. Nas referidas condições, obtiveram-se produtos com um teor de FAME’s de 95,7 % na catálise com CaO-N2 e 95,3 % na catálise com CaO-Ar. Alguns autores de estudos consultados no desenvolvimento do presente trabalho, referiam como principal problema da utilização do CaO, a lixiviação de cálcio para os produtos obtidos. Este facto foi confirmado no presente trabalho e na tentativa de o contornar, tentou-se promover a carbonatação do cálcio com a passagem de ar comprimido através dos produtos e subsequente filtração. Após a realização deste tratamento, não mais se observaram alterações nas suas propriedades (aparecimento de turvação ou precipitados), no entanto, nos produtos obtidos nas condições óptimas, a concentração de cálcio determinada foi de 527 mg/kg no produto da reacção catalisada com CaO-N2 e 475 mg/kg com CaO-A. O óxido de cálcio apresentou-se como um excelente catalisador na transesterificação da mistura de óleos alimentares usados utilizada no presente trabalho, apresentando uma performance ao nível da obtida por catálise homogénea básica. Não se observaram diferenças significativas de performance entre o CaO-N2 e o CaO-Ar, sendo possível obter nas mesmas condições reaccionais produtos com teores de FAME’s superiores a 95 % utilizando qualquer um deles como catalisador. O elevado teor de cálcio lixiviado observado nos produtos, apresenta-se como o principal obstáculo à aplicação a nível industrial do óxido de cálcio como catalisador para a transesterificação de óleos.
Resumo:
The most practicable assay for measurement of measles IgG (mIgG) in large numbers of sera is an enzyme immunoassay (EIA). To assess how EIA results would agree with those by the gold standard method of plaque reduction neutralization (PRN) we compared the results from the two methods in 43 pairs of maternal and umbilical cord sera, and sera from the corresponding infants when aged 11 - 14 months. In maternal-cord sera, the differences between mean antibody levels by EIA or PRN were not statistically significant, though in individual sera, differences could be large. However, agreement was less good for infants sera, in which levels of mIgG were very low. The conclusions of a study of transplacental transport of mIgG would not be affected by the use of either technique. When studying waning immunity in infants, PRN should be the method of choice, while results from studies using EIA should be interpreted with caution.