978 resultados para Cosmological constant
Resumo:
Despite the frequent use of stepping motors in robotics, automation, and a variety of precision instruments, they can hardly be found in rotational viscometers. This paper proposes the use of a stepping motor to drive a conventional constant-shear-rate laboratory rotational viscometer to avoid the use of velocity sensor and gearbox and, thus, simplify the instrument design. To investigate this driving technique, a commercial rotating viscometer has been adapted to be driven by a bipolar stepping motor, which is controlled via a personal computer. Special circuitry has been added to microstep the stepping motor at selectable step sizes and to condition the torque signal. Tests have been carried out using the prototype to produce flow curves for two standard Newtonian fluids (920 and 12 560 mPa (.) s, both at 25 degrees C). The flow curves have been obtained by employing several distinct microstep sizes within the shear rate range of 50-500 s(-1). The results indicate the feasibility of the proposed driving technique.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The scientific question addressed in this work is: what hides beneath first order kinetic constant k (s(-1)) measured for hybridization of a DNA target on a biosensor surface. Kinetics hybridization curves were established with a 27 MHz quartz microbalance (9 MHz, third harmonic) biosensor, constituted of a 20-base probe monolayer deposited on a gold covered quartz surface. Kinetics analysis, by a known two-step adsorption-hybridization mechanism, is well appropriate to fit properly hybridization kinetics curves, for complementary 20-base to 40-base targets over two concentration decades. It was found that the K-1 (M-1) adsorption constant, relevant to the first step, concerns an equilibrium between non hybridized targets and hybridized pre-complex and increases with DNA target length. It was established that k(2) (s(-1)), relevant to irreversible formation of a stable duplex, varies in an opposite way to K-1 with DNA target length. (C) 2012 Published by Elsevier B.V.
Resumo:
This paper presents the analysis and the design of a peak-current-controlled high-power-factor boost rectifier, with slope compensation, operating at constant frequency. The input current shaping is achieved, with continuous inductor current mode, with no multiplier to generate a current reference. The resulting overall circuitry is very simple, in comparison with the average-current-controlled boost rectifier. Experimental results are presented, taken from a laboratory prototype rated at 370 W and operating at 67 kHz. The measured power factor was 0.99, with a input current THD equal to 5.6%, for an input voltage THD equal to 2.26%.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A simple constant-current electrocutaneous stimulator for high-impedance loads using low-cost, standard high-voltage components is presented. A voltage-regulator powers an oscillator built across the primary of a transformer whose secondary delivers, after rectification, the high-voltage supply to switched current-mirrors in the driving stage. Since the compliance high-voltage is proportional to the stimulation current, overall power consumption is minimized. By adjusting the regulated voltage, control of the pulsed-current amplitude is achieved. A prototype with readily available components features stimulation currents of amplitude and pulsewidth in the range 0≤Iskin≤20mA and 50μs ≤Tpulse≤1ms, respectively. Pulse-repetition spans from 1 Hz to 10Hz. Worst-case ripple is 3.7% @Iskin=1mA. Measured pulse fall-time is shorter than 32μs. Overall consumption is 4.4W @Iskin=20mA. Subject isolation from line is 4KV.
Resumo:
We discuss phenomenological tests for the frozen infrared behavior of the running coupling constant and gluon propagators found in some solutions of Schwinger-Dyson equations of the gluonic sector of QCD. We verify that several observables can be used in order to select the different expressions of αs found in the literature. We test the effect of the nonperturbative coupling in the τ-lepton decay rate into nonstrange hadrons, in the ρ vector meson helicity density matrix that are produced in the χc2 → ρρ decay, in the photon to pion transition form factor, and compute the cross-sections for elastic proton-proton scattering and exclusive ρ production in deep inelastic scattering. These quantities depend on the infrared behavior of the coupling constant at different levels, we discuss the reasons for this dependence and argue that the existent and future data can be used to test the approximations performed to solve the Schwinger-Dyson equations and they already seem to select one specific infrared behavior of the coupling.
Resumo:
This paper adresses the problem on processing biological data such as cardiac beats, audio and ultrasonic range, calculating wavelet coefficients in real time, with processor clock running at frequency of present ASIC's and FPGA. The Paralell Filter Architecture for DWT has been improved, calculating wavelet coefficients in real time with hardware reduced to 60%. The new architecture, which also processes IDWT, is implemented with the Radix-2 or the Booth-Wallace Constant multipliers. Including series memory register banks, one integrated circuit Signal Analyzer, ultrasonic range, is presented.
Resumo:
Dichotomic maps are considered by means of the stability of the null solution of a class of differential equations with piecewise constant argument via associated discrete equations. Copyright © 2008 Watam Press.
Resumo:
Objective - To evaluate the effects of increasing doses of remifentanil hydrochloride administered via constant rate infusion (CRI) on the minimum alveolar concentration (MAC) of isoflurane in cats. Animals - 6 healthy adult cats. Procedures - For each cat, 2 experiments were performed (2-week interval). On each study day, anesthesia was induced and maintained with isoflurane; a catheter was placed in a cephalic vein for the administration of lactated Ringer's solution or remifentanil CRIs, and a catheter was placed in the jugular vein for collection of blood samples for blood gas analyses. On the first study day, individual basal MAC (MAC Basal) was determined for each cat. On the second study day, 3 remifentanil CRIs (0.25, 0.5, and 1.0 μg/kg/min) were administered (in ascending order); for each infusion, at least 30 minutes elapsed before determination of MAC (designated as MAC R0.25, MAC R0.5, and MAC R1.0, respectively). A 15-minute washout period was allowed between CRIs. A control MAC (MAC Control) was determined after the last remifentanil infusion. Results - Mean ± SD MAC Basal and MAC Control values at sea level did not differ significantly (1.66 ± 0.08% and 1.52 ± 0.21%, respectively). The MAC values determined for each remifentanil CRI did not differ significantly. However, MAC R0.25, MAC R0.5, and MAC R1.0, were significantly decreased, compared with MAC Basal, by 23.4 ± 79%, 29.8 ± 8.3%, and 26.0 ± 9.4%, respectively. Conclusions and Clinical Relevance - The 3 doses of remifentanil administered via CRI resulted in a similar degree of isoflurane MAC reduction in adult cats, indicating that a ceiling effect was achieved following administration of the lowest dose.
Resumo:
This paper deals with the study of the basic theory of existence, uniqueness and continuation of solutions of di®erential equations with piecewise constant argument. Results about asymptotic stability of the equation x(t) =-bx(t) + f(x([t])) with argu- ment [t], where [t] designates the greatest integer function, are established by means of dichotomic maps. Other example is given to illustrate the application of the method. Copyright © 2011 Watam Press.
Resumo:
This work proposes a new three-phase multipulse rectifier based on the delta autotransformer connection with DC-DC Boost stages and constant hysteresis control which has the objective of providing a reliable DC bus for on-board applications, electric motor drives and similars, always considering power quality issues. Thus, the proposal presents 0.99 power factor, 6% harmonic distortions in the currents from the mains and enhanced magnetic core utilization, which results in low weight and volume for the overall converter. The proposed control technique uses the simple constant hysteresis concept, thus leading to a low-cost but effective and reliable strategy. © 2011 IEEE.
Resumo:
Constant rate infusion (CRI) shows several advantages in balanced anesthesia, such as reduction of requirement for inhaled anesthetics and control of pain. The most commonly used drugs in these protocols are local anesthetics, dissociative, and opioids, which may be administered alone or in combinations. We evaluated the records of 200 dogs that underwent various surgical procedures with anesthetic or analgesic CRI in the perioperative period during 2011 and 2012 at the Veterinary Hospital of Franca University (Unifran), and identified possible complications during the transoperative period. Records evaluated included clinical state, laboratory tests, drugs used in premedication and induction, and CRI protocol. Acepromazine and morphine were the main drugs used in premedication. Propofol was used to induce anesthesia alone or in combination with other agents. We evaluated records of the 25 different CRI protocols. Fentanyl was the main drug employed in CRI, either alone or in combination. There were 128 episodes of anesthetic complications during CRI;the most common were hypotension, hypertension, and tachycardia, which occurred in 43 (32%), 35 (26.3%), and 19 (14.2%) dogs, respectively. Cardiac arrhythmia was reported in only 4 dogs. Signs of respiratory depression were present in dogs treated with 6 different CRI protocols. The consumption of isoflurane (vol %) reduced between 15.7% and 21.05% after 30minutes of the CRI in the fentanyl and fentanyl-lidocaine-ketamine CRI groups (p<0.05). In conclusion, CRI is a valid component of balanced anesthesia in dogs, safe, and has a low incidence of adverse effects. However, future studies are warranted to describe the results of the clinical use of CRI to better characterize and refine this technique.
Resumo:
A detailed dynamical analysis of the tachyonic teleparallel dark energy model, in which a noncanonical scalar field (tachyon field) is nonminimally coupled to gravitation, is performed. It is found that, when the nonminimal coupling is ruled by a dynamically changing coefficient α≡f ,φ/√f, with f(φ) an arbitrary function of the scalar field φ, the Universe may experience a field-matter-dominated era φMDE, in which it has some portions of the energy density of φ in the matter dominated era. This is the most significant difference in relation to the so-called teleparallel dark energy scenario, in which a canonical scalar field (quintessence) is nonminimally coupled to gravitation. © 2013 American Physical Society.
Resumo:
Pós-graduação em Ciências Sociais - FFC