967 resultados para Congestion Window (cwnd)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Combining ionic liquids (ILs) with polymers offers the prospect of new applications, where they surpass the performance of conventional media, such as organic solvents, giving advantages in terms of improved safety and a higher operating temperature range. In this work we have investigated the morphology, thermal and electrochemical properties of polymer electrolytes prepared through the addition of con- trolled quantities of the cholinium based IL N,N,N-trimethyl-N-(2-hydroxyethyl)ammonium bis(trifluo- romethylsulfonyl)imide ([N1 1 1 2(OH)] [NTf2]) to a deoxyribonucleic acid (DNA) host network. These novel IL-based electrolytes have been analyzed aiming at applications in electrochemical devices. An optimized sample showed good thermal stability up to 155 °C and a wide electrochemical window of ~3.5 V. The highest conductivity was registered for the DNA[N1 1 1 2(OH)][NTf2] (1:1) (2.82 × 10-5 and 1.09 × 10-3 S cm-1 at 30 and 100 °C, respectively).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

New polymer electrolytes (PEs) based on chitosan and three ionic liquid (IL) families ([C2mim][CnSO3], [C2mim][CnSO4] and [C2mim][diCnPO4]) were synthesized by the solvent casting method. The effect of the length of the alkyl chain of the IL anion on the thermal, morphological and electrochemical properties of the PEs was studied. The solid polymer electrolytes (SPE) membranes were analyzed by differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray (EDX), polarized optical microscopy (POM), atomic force microscopy (AFM), complex impedance spectroscopy (ionic conductivity) and cyclic voltammetry (CV). The obtained results evidenced an influence of the alkyl chain length of the IL anion on the temperature of degradation, birefringence, surface roughness and ionic conductivity of the membranes. The DSC, XRD and CV results showed independency from the length of the IL-anion-alkyl chain. The PEs displayed an predominantly amorphous morphology, a minimum temperature of degradation of 135 °C, a room temperature (T = 25 °C) ionic conductivity of 7.78 × 10−4 S cm−1 and a wide electrochemical window of ∼ 4.0 V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Silk fibroin (SF) is a commonly available natural biopolymer produced in specialized glands of arthropods, with a long history of use in textile production and also in health cares. The exceptional intrinsic properties of these fibers, such as self-assembly, machinability, biocompatibility, biodegradation or non-toxicity, offer a wide range of exciting opportunities [1]. It has long been recognized that silk can be a rich source of inspiration for designing new materials with tailored properties, enhanced performance and high added value for targeted applications, opening exciting new prospects in the domain of materials science and related technological fields, including bio-friendly integration, miniaturization and multifunctionalization. In recent years it has been demonstrated that fibroin is an excellent material for active components in optics and photonics devices. Progress in new technological fields such as optics, photonics and electronics are emerging [2,3]. The incorporation of polymer electrolytes as components of various devices (advanced batteries, smart windows, displays and supercapacitors) offers significant advantages with respect to traditional electrolytes, including enhanced reliability and improved safety. SF films are particularly attractive in this context. They have near-perfect transparency across the VIS range, surface flatness (together with outstanding mechanical robustness), ability to replicate patterned substrates and their thickness may be easily tailored from a few nanometers to hundreds of micrometers through spin-casting of a silk solution into subtract. Moreover, fibroin can be added to other biocomponents or salts in order to modify the biomaterial properties leading to optimized and total different functions. Preliminary tests performed with a prototype electrochromic device (ECD) incorporating SF films doped with lithium triflate and lithium tetrafluoroborate (LiTFSI and LiBF4, respectively) as electrolyte and WO3 as cathodic electrochromic layer, are extremely encouraging. Aiming to evaluate the performance of the ion conducting SF membranes doped with LiTFSI and LiBF4 (SF-Li), small ECDs with glass/ITO/WO3/SF-Li/CeO2-TiO2/ITO/glass configuration were assembled and characterized. The device exhibited, after 4500 cycles, the insertion of charge at -3.0 V reached –1.1 mC.cm-2 in 15 s. After 4500 cycles the window glass-staining, glass/ITO/WO3/Fibrin-Li salts electrolyte/CeO2-TiO2/ITO/glass configuration was reversible and featured a T  8 % at λ = 686 nm

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Materials Engineering

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia e Gestão de Sistemas de Informação

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Civil

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Relatório de estágio de mestrado em Sociologia (área de Especialização em Organizações e Trabalho)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Informática Médica)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de Mestrado Ciclo de Estudos Integrados Conducentes ao Grau de Mestre em Arquitectura Área de Especialização: Construção e Tecnologia

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado em Ciências da Comunicação (área de especialização em Informação e Jornalismo)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors describe a case of pericardial effusion accompanied by cardiac tamponade caused by primary hypothyroidism. Diagnosis was made by exclusion, because other causes of cardiac tamponade are more frequent. Emergency treatment of cardiac tamponade is pericardiocentesis (with possible pericardial window), and, after stabilization, performance of hormonal reposition therapy with L-thyroxin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de Doutoramento em Ciências da Saúde

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de Doutoramento em Ciência e Engenharia de Polímeros e Compósitos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O treino competitivo envolve exercício intenso e prolongado, capaz de modular o número e actividade das células imunitárias. Quando demasiado exigente poderá induzir fadiga e aumentar a susceptibilidade a doenças. Esta dissertação apresenta três estudos desenvolvidos no âmbito da Imunologia do Exercício, considerando a análise da resposta celular imunitária sistémica aguda e crónica ao exercício aplicada em situações reais do treino competitivo de natação, controlando factores passíveis de influenciar esta resposta. Pretendeu-se avaliar a resposta imunitária a uma sessão de treino prolongada e intensa, durante as 24h de recuperação (Estudo 1) e a uma época de treino com sete meses (Estudo 2), e estudar a influência de um macrociclo de treino de quatro meses sobre a resposta imunitária à mesma sessão de treino e período de recuperação (Estudo 3), controlando sexo, fases do ciclo menstrual, maturidade, escalão, especialidade, performance, cargas de treino e sintomas respiratórios superiores (URS). A sessão de treino induziu a diminuição da vigilância imunitária adquirida imediatamente e, pelo menos nas 2h seguintes. Juvenis e seniores recuperaram totalmente 24h depois, mas não os juniores, reforçando a ideia da existência de uma janela aberta para a infecção após exercícios prolongados e intensos e sugerindo uma recuperação menos eficiente para os juniores. No período de treino mais intenso da época observou-se uma imunodepressão e maior prevalência de URS. No final da época, a imunidade inata diminuiu aparentando maior sensibilidade aos efeitos cumulativos da carga de treino, enquanto a imunidade adquirida parece ter recuperado após o taper. O macrociclo de treino atenuou a resposta imunitária à sessão de treino e aumentou o período de janela aberta às infecções (efeitos mais acentuados nos adolescentes). Os resultados evidenciam a importância de controlar alterações imunitárias durante a época competitiva, especialmente em períodos de treino intenso e quando se realizam sessões de treino intensas consecutivas com recuperações inferiores a 24h.