1000 resultados para Banda
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo Energia
Resumo:
Mestrado em Engenharia Electrotécnica e de Computadores - Área de Especialização de Telecomunicações
Resumo:
Tese de Douturamento
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Eletrónica e Telecomunicações
Resumo:
O presente trabalho teve como objetivo a produção de exoantígenos H e M das amostras 58, B-679, A-811 e O187 de Histoplasma capsulatum, utilizando o meio NGTA (neopeptona, glicose, tiamina e asparagina) em períodos de cultivo de 1, 2 e 3 meses, a 36ºC, sob agitação constante (50 v.p.m.). Os antígenos brutos foram avaliados contra anti-soro e antígeno de Histoplasma capsulatum de referência (Center for Disease Control), 4 soros de pacientes portadores de paracoccidioidomicose, 7 de histoplasmose e soro hiperimune anti-H. capsulatum produzido em coelhos, através da reação de imunodifusão dupla. Verificou-se que, com exceção de B-679 com 1 mês de crescimento, todos os demais exoantígenos apresentaram as frações H e M de precipitação. Os exoantígenos obtidos de A-811 apresentaram só a banda H. Excetuando-se os exoantígenos 58 e B-679 com 1 mês de crescimento, todos os demais exoantígenos reagiram contra soros de pacientes com histoplasmose. Em relação aos soros de pacientes com paracoccidioidomicose, somente os exoantígenos 58 e O187 não apresentaram reação cruzada. Todos os exoantígenos reagiram frente ao soro hiperimune de coelho anti-H. capsulatum. Para obtenção de exoantígenos de H. capsulatum, sugerimos que as amostras sejam cultivadas sob as condições anteriormente descritas, adotando-se o período de 3 meses de crescimento, utilizando-se exoantígenos de referência como controles da reação.
Resumo:
Dissertação apresentada para obtenção do Grau de Doutor em Química, especialidade Química Inorgânica, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia.
Resumo:
Dissertação apresentada para obtenção do Grau de Doutor em Biologia Especialidade Biologia Molecular pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia. A presente dissertação foi preparada no Departamento de Bacteriologia do Laboratório Nacional de Investigação Veterinária
Resumo:
Trabalho final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações
Resumo:
Dissertação de Mestrado em Engenharia Informática
Resumo:
Trabalho de Dissertação de Natureza Científica para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização em Estruturas
Resumo:
Os osciloscópios digitais são utilizados em diversas áreas do conhecimento, assumindo-se no âmbito da engenharia electrónica, como instrumentos indispensáveis. Graças ao advento das Field Programmable Gate Arrays (FPGAs), os instrumentos de medição reconfiguráveis, dadas as suas vantagens, i.e., altos desempenhos, baixos custos e elevada flexibilidade, são cada vez mais uma alternativa aos instrumentos tradicionalmente usados nos laboratórios. Tendo como objectivo a normalização no acesso e no controlo deste tipo de instrumentos, esta tese descreve o projecto e implementação de um osciloscópio digital reconfigurável baseado na norma IEEE 1451.0. Definido de acordo com uma arquitectura baseada nesta norma, as características do osciloscópio são descritas numa estrutura de dados denominada Transducer Electronic Data Sheet (TEDS), e o seu controlo é efectuado utilizando um conjunto de comandos normalizados. O osciloscópio implementa um conjunto de características e funcionalidades básicas, todas verificadas experimentalmente. Destas, destaca-se uma largura de banda de 575kHz, um intervalo de medição de 0.4V a 2.9V, a possibilidade de se definir um conjunto de escalas horizontais, o nível e declive de sincronismo e o modo de acoplamento com o circuito sob análise. Arquitecturalmente, o osciloscópio é constituído por um módulo especificado com a linguagem de descrição de hardware (HDL, Hardware Description Language) Verilog e por uma interface desenvolvida na linguagem de programação Java®. O módulo é embutido numa FPGA, definindo todo o processamento do osciloscópio. A interface permite o seu controlo e a representação do sinal medido. Durante o projecto foi utilizado um conversor Analógico/Digital (A/D) com uma frequência máxima de amostragem de 1.5MHz e 14 bits de resolução que, devido às suas limitações, obrigaram à implementação de um sistema de interpolação multi-estágio com filtros digitais.
Resumo:
Dissertação apresentada para obtenção do Grau de Doutor em Nanotecnologias e Nanociências pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia.
Resumo:
As the wireless cellular market reaches competitive levels never seen before, network operators need to focus on maintaining Quality of Service (QoS) a main priority if they wish to attract new subscribers while keeping existing customers satisfied. Speech Quality as perceived by the end user is one major example of a characteristic in constant need of maintenance and improvement. It is in this topic that this Master Thesis project fits in. Making use of an intrusive method of speech quality evaluation, as a means to further study and characterize the performance of speech codecs in second-generation (2G) and third-generation (3G) technologies. Trying to find further correlation between codecs with similar bit rates, along with the exploration of certain transmission parameters which may aid in the assessment of speech quality. Due to some limitations concerning the audio analyzer equipment that was to be employed, a different system for recording the test samples was sought out. Although the new designed system is not standard, after extensive testing and optimization of the system's parameters, final results were found reliable and satisfactory. Tests include a set of high and low bit rate codecs for both 2G and 3G, where values were compared and analysed, leading to the outcome that 3G speech codecs perform better, under the approximately same conditions, when compared with 2G. Reinforcing the idea that 3G is, with no doubt, the best choice if the costumer looks for the best possible listening speech quality. Regarding the transmission parameters chosen for the experiment, the Receiver Quality (RxQual) and Received Energy per Chip to the Power Density Ratio (Ec/N0), these were subject to speech quality correlation tests. Final results of RxQual were compared to those of prior studies from different researchers and, are considered to be of important relevance. Leading to the confirmation of RxQual as a reliable indicator of speech quality. As for Ec/N0, it is not possible to state it as a speech quality indicator however, it shows clear thresholds for which the MOS values decrease significantly. The studied transmission parameters show that they can be used not only for network management purposes but, at the same time, give an expected idea to the communications engineer (or technician) of the end-to-end speech quality consequences. With the conclusion of the work new ideas for future studies come to mind. Considering that the fourth-generation (4G) cellular technologies are now beginning to take an important place in the global market, as the first all-IP network structure, it seems of great relevance that 4G speech quality should be subject of evaluation. Comparing it to 3G, not only in narrowband but also adding wideband scenarios with the most recent standard objective method of speech quality assessment, POLQA. Also, new data found on Ec/N0 tests, justifies further research studies with the intention of validating the assumptions made in this work.
Resumo:
O diagnóstico da fasciolose é feito principalmente por métodos serológicos, devido ao polimorfismo do quadro clínico e à baixa sensibilidade dos métodos parasitológicos. Contudo, estes métodos apresentam algumas limitações, pelo que a melhoria dos testes imunológicos, nomeadamente, a utilização de antigénio homólogo, pode ser um factor relevante para a especificidade do diagnóstico. Este estudo teve como objectivo a produção e avaliação de antigénios total e deslipidizado de F. gigantica no imunodiagnóstico da fasciolose pelos métodos de Micro-ELISA e Western-blot, em comparação com os de F. hepatica. Foram analisados 111 soros de indivíduos cabo-verdianos e 67 de indivíduos residentes em Portugal, de ambos os sexos, com suspeita clínica de fasciolose. Os antigénios, total e deslipidizado, foram produzidos a partir de vermes adultos de F. gigantica recolhidos de bovinos na ilha de Santiago (Cabo Verde). Os antigénios totais das duas espécies de Fasciola apresentaram a mesma sensibilidade (100%), mas a especificidade foi superior para o antigénio total de F. gigantica (95,2%), na detecção de IgG. À semelhança dos antigénios totais, os deslipidizados demonstraram uma sensibilidade de 100%. Contudo, a especificidade foi superior (95,2%) quando se utilizou o antigénio deslipidizado de F. hepatica em relação à obtida com F. gigantica, cujo valor foi de 90,5%. Quanto à detecção de IgM anti-Fasciola, os valores de sensibilidade e especificidade foram de 97% e 90,5%, respectivamente, para os antigénios totais dos dois parasitas. Na pesquisa de IgM anti-parasita, as sensibilidades foram 94% e 83% para os antigénios deslipidizados de F. gigantica e F. hepatica, respectivamente, com uma especificidade de 90,5% para ambos os antigénios deslipidizados. No Immunobloting, a fracção antigénica de 24 kDa foi comum nas quatro preparações antigénicas, quer para IgM quer para IgG anti-Fasciola, pelo que a sua caracterização poderá ser relevante para o desenvolvimento de métodos com maior especificidade e reprodutibilidade, melhorando significativamente o diagnóstico. A banda de 26 kDa, presente apenas no antigénio total de F. gigantica, parece ser específica deste parasita. Este facto leva-nos a concluir que esta banda poderá ser objecto de mais estudos, no sentido de vir a ter-se um diagnóstico diferencial entre as duas espécies de Fasciola.
Resumo:
Mestrado em Engenharia Informática