885 resultados para BEV, Battery Electric Vehicle, Simulink model, thermal management system, heat pump
Resumo:
The objective of the work has been to study why systems thinking should be used in combination with TQM, what are the main benefits of the integration and how it could best be done. The work analyzes the development of systems thinking and TQM with time and the main differences between them. The work defines prerequisites for adopting a systems approach and the organizational factors which embody the development of an efficient learning organization. The work proposes a model based on combination of an interactive management model and redesign to be used for application of systems approach with TQM in practice. The results of the work indicate that there are clear differences between systems thinking and TQM which justify their combination. Systems approach provides an additional complementary perspective to quality management. TQM is focused on optimizing operations at the operational level while interactive management and redesign of organization are focused on optimization operations at the conceptual level providing a holistic system for value generation. The empirical study demonstrates the applicability of the proposed model in one case study company but its application is tenable and possible also beyond this particular company. System dynamic modeling and other systems based techniques like cognitive mapping are useful methods for increasing understanding and learning about the behavior of systems. The empirical study emphasizes the importance of using a proper early warning system.
Resumo:
Electricity distribution network operation (NO) models are challenged as they are expected to continue to undergo changes during the coming decades in the fairly developed and regulated Nordic electricity market. Network asset managers are to adapt to competitive technoeconomical business models regarding the operation of increasingly intelligent distribution networks. Factors driving the changes for new business models within network operation include: increased investments in distributed automation (DA), regulative frameworks for annual profit limits and quality through outage cost, increasing end-customer demands, climatic changes and increasing use of data system tools, such as Distribution Management System (DMS). The doctoral thesis addresses the questions a) whether there exist conditions and qualifications for competitive markets within electricity distribution network operation and b) if so, identification of limitations and required business mechanisms. This doctoral thesis aims to provide an analytical business framework, primarily for electric utilities, for evaluation and development purposes of dedicated network operation models to meet future market dynamics within network operation. In the thesis, the generic build-up of a business model has been addressed through the use of the strategicbusiness hierarchy levels of mission, vision and strategy for definition of the strategic direction of the business followed by the planning, management and process execution levels of enterprisestrategy execution. Research questions within electricity distribution network operation are addressed at the specified hierarchy levels. The results of the research represent interdisciplinary findings in the areas of electrical engineering and production economics. The main scientific contributions include further development of the extended transaction cost economics (TCE) for government decisions within electricity networks and validation of the usability of the methodology for the electricity distribution industry. Moreover, DMS benefit evaluations in the thesis based on the outage cost calculations propose theoretical maximum benefits of DMS applications equalling roughly 25% of the annual outage costs and 10% of the respective operative costs in the case electric utility. Hence, the annual measurable theoretical benefits from the use of DMS applications are considerable. The theoretical results in the thesis are generally validated by surveys and questionnaires.
Resumo:
Vaihtosuuntaajan IGBT-moduulin liitosten lämpötiloja ei voida suoraan mitata, joten niiden arviointiin tarvitaan reaaliaikainen lämpömalli. Tässä työssä on tavoitteena kehittää tähän tarkoitukseen C-kielellä implementoitu ratkaisu, joka on riittävän tarkka ja samalla mahdollisimman laskennallisesti tehokas. Ohjelmallisen toteutuksen täytyy myös sopia erilaisille moduulityypeille ja sen on tarvittaessa otettava huomioon saman moduulin muiden sirujen lämmittävä vaikutus toisiinsa. Kirjallisuuskatsauksen perusteella valitaan olemassa olevista lämpömalleista käytännön toteutuksen pohjaksi lämpöimpedanssimatriisiin perustuva malli. Lämpöimpedanssimatriisista tehdään Simulink-ohjelmalla s-tason simulointimalli, jota käytetään referenssinä muun muassa implementoinnin tarkkuuden verifiointiin. Lämpömalli tarvitsee tiedon vaihtosuuntaajan häviöistä, joten työssä on selvitetty eri vaihtoehtoja häviölaskentaan. Lämpömallin kehittäminen s-tason mallista valmiiksi C-kieliseksi koodiksi on kuvattu tarkasti. Ensin s-tason malli diskretoidaan z-tasoon. Z-tason siirtofunktiot muutetaan puolestaan ensimmäisen kertaluvun differenssiyhtälöiksi. Työssä kehitetty monen aikatason lämpömalli saadaan jakamalla ensimmäisen kertaluvun differenssiyhtälöt eri aikatasoille suoritettavaksi sen mukaan, mikä niiden kuvaileman termin vaatima päivitysnopeus on. Tällainen toteutus voi parhaimmillaan kuluttaa alle viidesosan kellojaksoja verrattuna suoraviivaiseen yhden aikatason toteutukseen. Implementoinnin tarkkuus on hyvä. Implementoinnin vaatimia suoritusaikoja testattiin Texas Instrumentsin TMS320C6727- prosessorilla (300 MHz). Esimerkkimallin laskemisen määritettiin kuluttavan vaihtosuuntaajan toimiessa 5 kHz kytkentätaajuudella vain 0,4 % prosessorin kellojaksoista. Toteutuksen tarkkuus ja laskentakapasiteetin vähäinen vaatimus mahdollistavat lämpömallin käyttämisen lämpösuojaukseen ja lisäämisen osaksi muuta jo prosessorilla olemassa olevaa systeemiä.
Resumo:
Tulevaisuudessa sähköverkko kohtaa monia haasteita, kun sähköautot yleistyvät, vaatien suuren tehotarpeen. Uusiutuvan energiantuotannon epävarma huipputehon tuotanto ei välttämättä pysty kattamaan sähköautoista johtuvaa suurta tehopiikkiä, jos suuret määrät ajoneuvoista kytketään yhtä aikaa lataukseen. Jos sähköajoneuvot voidaan ladata ohjatusti, ei välttämättä tarvita lisäenergian tuotantoa kattamaan kasvanutta huipputehon tarvetta. Lisäksi sähköajoneuvojen akut toimivat koko sähköverkolle energiavarastoina, jollaista ei ole ennen ollut. Älykkäällä sähköverkolla voidaan ohjata sähköajoneuvon latausta, mikäli ajoneuvossa on ohjausjärjestelmä ja akkujen varaustilan mittaus. Tässä kandidaatin työssä ohjelmoidaan mittaus- ja ohjauskortti plug-in hybridiautoa varten, jossa on V2G-ominaisuus. Ohjainkortista toteutetaan toimintakuvaus, jonka mukaan se myös ohjelmoidaan. Ohjainkortti mittaa akkujen jännitettä ja virtaa, joista voidaan määrittää akkujen varaustilat. Ohjainkortti lähettää tiedot eteenpäin PC:lle, jolta ohjainkortti saa käskyn toimintatilasta. Mittaustietojen perusteella voidaan seurata mahdollisia vikatilanteita. Kandidaatintyön aikana ohjainkorttia ei ehditty asentamaan ajoneuvoon, mutta laboratoriotestien mukaan voidaan todeta, että ohjainkortti on ohjelmallisesti toimiva. Mittauksissa selvisi, että ohjainkortin mittaustulot eivät olleet tarpeeksi tarkkoja käyttökohteeseen. Todettiin, että ohjainkortti vaatii rakenteellisia muutoksia mittaustuloksien parantamista varten, ennen ohjainkortin käyttöönottoa, mutta kandidaatintyön tavoitteet saavutettiin.
Resumo:
ABSTRACTThis study presents a contribution to the modeling of a computer application employing a method of serviceability performance for unpaved roads, aiming the management of maintenance/restoration activities of the primary surface layer. The proposed methodology consisted of field inspections during dry (April to September) and rainy (October to March) periods, during which objective evaluations were performed to survey of defects and their densities and degrees of severity. To aid the functional classification of analyzed road sections and the determination of the defect with major influence on the serviceability of these roads, the method of serviceability performance proposed by Silva (2009)was implemented in the Visual Basic for Applications (VBA) language in Microsoft Excel software. With the use of the computer application proposed it was possible to identify among the defects analyzed in field, through the index of serviceability of the sampling unit per defect type (ISUdef), which one had the greatest influence on determining the relative serviceability index per road section (IST). The results allow us to conclude that the computer application Road achieved satisfactory results, since the objective evaluation criteria applied to road sections denotes consistency regarding their serviceability.
Resumo:
Tässä kandidaatintyössä tarkastellaan sähköajoneuvojen yleistymisen vaikutuksia Suomen sähköverkkoihin. Työssä käsitellään myös sähköajoneuvojen, sekä hybridi- että täyssähköajoneuvon, toimintaperiaate, akkuteknologiaa ja latausvaihtoehtoja, sekä mahdollisia muita vaihtoehtoja nykyiselle polttonesteajoneuvokannalle. Kirjallisuustutkimuksessa käydään läpi myös mahdolliset sähköajoneuvojen yleistymisskenaariot. Tutkimuksessa käydään läpi yleistymisen vaikutukset sähkön siirtoverkkoon, keskijänniteverkkoon, pienjänniteverkkoon sekä sähköntuotantoon.
Resumo:
The aim of this report is to describe the current status of the waste-to-energy chain in the province of Northern Savonia in Finland. This work is part of the Baltic Sea Region Programme project Remowe-Regional Mobilizing of Sustainable Waste-to-Energy Production (2009-2012). Partnering regions across Baltic Sea countries have parallelly investigated the current status, bottle-necks and needs for development in their regions. Information about the current status is crucial for the further work within the Remowe project, e.g. in investigating the possible future status in target regions. Ultimate result from the Northern Savonia point of view will be a regional model which utilizes all available information and facilitates decision-making concerning energy utilization of waste. The report contains information on among others: - waste management system (sources, amounts, infrastructure) - energy system (use, supply, infrastructure) - administrative structure and legislation - actors and stakeholders in the waste-to-energy field, including interest and development ideas The current status of the regions will be compared in a separate Remowe report, with the focus on finding best practices that could be transferred among the regions. In this report, the current status has been defined as 2006-2009. In 2009, the municipal waste amount per capita was 479 kg/inhabitant in Finland. Industrial waste amounted 3550 kg/inhabitant, respectively. The potential bioenergy from biodegradable waste amounts 1 MWh/inhabitant in Northern Savonia. This figure includes animal manure, crops that would be suitable for energy use, sludge from municipal sewage treatment plants and separately collected biowaste. A key strategy influencing also to Remowe work is the waste plan for Eastern Finland. Currently there operate two digestion plants in Northern Savonia: Lehtoniemi municipal sewage treatment sludge digestion plant of Kuopion Vesi and the farm-scale research biogas plant of Agrifood Research Finland in Maaninka. Moreover, landfill gas is collected to energy use from Heinälamminrinne waste management centre and Silmäsuo closed landfill site, both belonging to Jätekukko Oy. Currently there is no thermal utilization of waste in Northern Savonia region. However, Jätekukko Oy is pretreating mixed waste and delivering refuse derived fuel (RDF) to Southern Finland to combustion. There is a strong willingness among seven regional waste management companies in Eastern Finland to build a waste incineration plant to Riikinneva waste management centre near city of Varkaus. The plant would use circulating fluidized bed (CFB) boiler. This would been a clear boost in waste-to-energy utilization in Northern Savonia and in many surrounding regions.
Resumo:
The number of electric vehicles grows continuously and the implementation of charging electric vehicles is an important issue for the future. Increasing amount of electric vehicles can cause problems to distribution grid by increasing peak load. Currently charging of electric vehicles is uncontrolled, but as the amount of electric vehicles grows, smart charg-ing (controlled charging) will be one possible solution to handle this situation. In this thesis smart charging of electric vehicles is examined from electricity retailers` point of view. The purpose is to find out plausible saving potentials of smart charging, when it´s controlled by price signal. Saving potential is calculated by comparing costs of price signal controlled charging and uncontrolled charging.
Resumo:
Thesis: A liquid-cooled, direct-drive, permanent-magnet, synchronous generator with helical, double-layer, non-overlapping windings formed from a copper conductor with a coaxial internal coolant conduit offers an excellent combination of attributes to reliably provide economic wind power for the coming generation of wind turbines with power ratings between 5 and 20MW. A generator based on the liquid-cooled architecture proposed here will be reliable and cost effective. Its smaller size and mass will reduce build, transport, and installation costs. Summary: Converting wind energy into electricity and transmitting it to an electrical power grid to supply consumers is a relatively new and rapidly developing method of electricity generation. In the most recent decade, the increase in wind energy’s share of overall energy production has been remarkable. Thousands of land-based and offshore wind turbines have been commissioned around the globe, and thousands more are being planned. The technologies have evolved rapidly and are continuing to evolve, and wind turbine sizes and power ratings are continually increasing. Many of the newer wind turbine designs feature drivetrains based on Direct-Drive, Permanent-Magnet, Synchronous Generators (DD-PMSGs). Being low-speed high-torque machines, the diameters of air-cooled DD-PMSGs become very large to generate higher levels of power. The largest direct-drive wind turbine generator in operation today, rated just below 8MW, is 12m in diameter and approximately 220 tonne. To generate higher powers, traditional DD-PMSGs would need to become extraordinarily large. A 15MW air-cooled direct-drive generator would be of colossal size and tremendous mass and no longer economically viable. One alternative to increasing diameter is instead to increase torque density. In a permanent magnet machine, this is best done by increasing the linear current density of the stator windings. However, greater linear current density results in more Joule heating, and the additional heat cannot be removed practically using a traditional air-cooling approach. Direct liquid cooling is more effective, and when applied directly to the stator windings, higher linear current densities can be sustained leading to substantial increases in torque density. The higher torque density, in turn, makes possible significant reductions in DD-PMSG size. Over the past five years, a multidisciplinary team of researchers has applied a holistic approach to explore the application of liquid cooling to permanent-magnet wind turbine generator design. The approach has considered wind energy markets and the economics of wind power, system reliability, electromagnetic behaviors and design, thermal design and performance, mechanical architecture and behaviors, and the performance modeling of installed wind turbines. This dissertation is based on seven publications that chronicle the work. The primary outcomes are the proposal of a novel generator architecture, a multidisciplinary set of analyses to predict the behaviors, and experimentation to demonstrate some of the key principles and validate the analyses. The proposed generator concept is a direct-drive, surface-magnet, synchronous generator with fractional-slot, duplex-helical, double-layer, non-overlapping windings formed from a copper conductor with a coaxial internal coolant conduit to accommodate liquid coolant flow. The novel liquid-cooling architecture is referred to as LC DD-PMSG. The first of the seven publications summarized in this dissertation discusses the technological and economic benefits and limitations of DD-PMSGs as applied to wind energy. The second publication addresses the long-term reliability of the proposed LC DD-PMSG design. Publication 3 examines the machine’s electromagnetic design, and Publication 4 introduces an optimization tool developed to quickly define basic machine parameters. The static and harmonic behaviors of the stator and rotor wheel structures are the subject of Publication 5. And finally, Publications 6 and 7 examine steady-state and transient thermal behaviors. There have been a number of ancillary concrete outcomes associated with the work including the following. X Intellectual Property (IP) for direct liquid cooling of stator windings via an embedded coaxial coolant conduit, IP for a lightweight wheel structure for lowspeed, high-torque electrical machinery, and IP for numerous other details of the LC DD-PMSG design X Analytical demonstrations of the equivalent reliability of the LC DD-PMSG; validated electromagnetic, thermal, structural, and dynamic prediction models; and an analytical demonstration of the superior partial load efficiency and annual energy output of an LC DD-PMSG design X A set of LC DD-PMSG design guidelines and an analytical tool to establish optimal geometries quickly and early on X Proposed 8 MW LC DD-PMSG concepts for both inner and outer rotor configurations Furthermore, three technologies introduced could be relevant across a broader spectrum of applications. 1) The cost optimization methodology developed as part of this work could be further improved to produce a simple tool to establish base geometries for various electromagnetic machine types. 2) The layered sheet-steel element construction technology used for the LC DD-PMSG stator and rotor wheel structures has potential for a wide range of applications. And finally, 3) the direct liquid-cooling technology could be beneficial in higher speed electromotive applications such as vehicular electric drives.
Resumo:
The design process of direct-driven permanent magnet synchronous machines (PMSMs) for a full electric 4 ´ 4 sports car is presented. The rotor structure of the machine consists of two permanent magnet layers embedded inside the rotor laminations thus resulting in some inverse saliency, where the q-axis inductance is larger than the d-axis one. An integer slot stator winding was selected to fully take advantage of the additional reluctance torque. The performance characteristics of the designed PMSMs were calculated by applying a twodimensional finite element method. Cross-saturation between the d- and q-axes was taken into account in the calculation of the synchronous inductances. The calculation results are validated by measurements.
Resumo:
One of the most prominent industrial applications of heat transfer science and engineering has been electronics thermal control. Driven by the relentless increase in spatial density of microelectronic devices, integrated circuit chip powers have risen by a factor of 100 over the past twenty years, with a somewhat smaller increase in heat flux. The traditional approaches using natural convection and forced-air cooling are becoming less viable as power levels increase. This paper provides a high-level overview of the thermal management problem from the perspective of a practitioner, as well as speculation on the prospects for electronics thermal engineering in years to come.
Resumo:
El estudio se realizó en 2014 para establecer la prevalencia de los factores de riesgo psicosocial en el personal civil y militar en una unidad militar de Bogotá D.C. De una población universo de 632 funcionarios, se tomó por muestreo probabilístico aleatorio a 264 funcionarios a quienes se les aplicó los cuestionarios para la evaluación de Factores de Riesgo Psicosocial Intralaboral, extralaboral, síntomas de estrés y la ficha de datos sociodemográficos y ocupacionales, de la Batería de Instrumentos del Ministerio de Trabajo Colombia [1]. El estudio permitió establecer que los niveles de riesgo con síntomas de estrés son altos; el 61,74% presenta riesgo Muy alto y Alto, el 15,53% riesgo medio y 22.73% riesgo Bajo y Muy bajo. El riesgo más alto lo presentan los oficiales, seguido del personal civil y suboficiales. De mantenerse las condiciones actuales sin intervención fácilmente podrían incrementarse y de acuerdo con el modelo sistémico expuesto por Villalobos 2005, se podrían asociar a respuestas de estrés [2], por tanto se recomienda implementar un Sistema de Vigilancia Epidemiológica para riesgo psicosocial con base en los diagnósticos y sistema de gestión en seguridad y salud en el trabajo, donde se involucre personal con diagnóstico de patología mental.
Resumo:
Climate change is one of the major challenges facing economic systems at the start of the 21st century. Reducing greenhouse gas emissions will require both restructuring the energy supply system (production) and addressing the efficiency and sufficiency of the social uses of energy (consumption). The energy production system is a complicated supply network of interlinked sectors with 'knock-on' effects throughout the economy. End use energy consumption is governed by complex sets of interdependent cultural, social, psychological and economic variables driven by shifts in consumer preference and technological development trajectories. To date, few models have been developed for exploring alternative joint energy production-consumption systems. The aim of this work is to propose one such model. This is achieved in a methodologically coherent manner through integration of qualitative input-output models of production, with Bayesian belief network models of consumption, at point of final demand. The resulting integrated framework can be applied either (relatively) quickly and qualitatively to explore alternative energy scenarios, or as a fully developed quantitative model to derive or assess specific energy policy options. The qualitative applications are explored here.
Resumo:
The thermal performance of a horizontal-coupled ground-source heat pump system has been assessed both experimentally and numerically in a UK climate. A numerical simulation of thermal behaviour of the horizontal-coupled heat exchanger for combinations of different ambient air temperatures, wind speeds, refrigerant temperature and soil thermal properties was studied using a validated 2D transient model. The specific heat extraction by the heat exchanger increased with ambient temperature and soil thermal conductivity, however it decreased with increasing refrigerant temperature. The effect of wind speed was negligible.
Comparing the thermal performance of horizontal slinky-loop and vertical slinky-loop heat exchangers
Resumo:
The heat pump market in the UK has grown rapidly over the last few years. Performance analyses of vertical ground-loop heat exchanger configurations have been widely carried out using both numerical modelling and experiments. However, research findings and design recommendations on horizontal slinky-loop and vertical slinky-loop heat exchangers are far fewer compared with those for vertical ground-loop heat exchanger configurations, especially where the long-term operation of the systems is concerned. The paper presents the results obtained from a numerical simulation for the horizontal slinky-loop and vertical slinky-loop heat exchangers of a ground-source heat pump system. A three-dimensional numerical heat transfer model was developed to study the thermal performance of various heat exchanger configurations. The influence of the loop pitch (loop spacing) and the depth of a vertical slinky-loop installation were investigated and the thermal performance and excavation work required for the horizontal and vertical slinky-loop heat exchangers were compared. The influence of the installation depth for vertical slinky-loop configurations was also investigated. The results of this study show that the influence of the installation depth of the vertical slinky-loop heat exchanger on the thermal performance of the system is small. The maximum difference in the thermal performance between the vertical and horizontal slinky-loop heat exchangers with the same loop diameter and loop pitch is less than 5%.