971 resultados para ANALOG


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pain is defined as an unpleasant sensory or emotional experience, associated with tissue damage, that is a reality linked to the surgical procedure and the postoperative period. Objective: Knowing the degree of pain experienced by patients after cardiac surgery, depending on the type of intervention they underwent, over the post-operative period in an intensive care unit (ICU). Method: Descriptive observational study. Pain was assessed by the visual analog scale (VAS), going from 0 to 10, thereby obtaining the first VAS1 assessment at 2 h post-extubation and every 8 hours thereafter up to 48 hours or until discharge to floor VAS7. It included patients having undergone cardiac surgery [valve surgery, bypass, combined procedure (including valve surgery and bypass) and mediastinitis]. Data were processed using Spss.v 20. Results: 120 patients 70 years old on average (standard deviation (SD): 13.3 years old) were included, out of which 70% were male. 40.8% of them had underwent bypass coronary revascularization. Patients subjected to the bypass technique showed an VAS1 mean value of 4.35 (SD: 2.45), unlike those subjected to valve surgery, who showed a mean value of 2.89 (SD: 2.27), those subjected to the combined procedure, who showed a mean value of 3.87 (SD: 2.90), and those with mediastinitis, who showed a mean value of 3.33 (SD: 3.51); (p < 0.031). 28.5% of patients had underwent revascularization (n = 49 ) by an internal mam mary artery (IMA) graft. These patients showed a mean value for VAS1 of 5.4 (SD: 1.89), unlike those who had underwent a combined procedure [IMA and saphenous vein (SV)], who showed a mean value of 3.9 (SD: 2.6), and those who had underwent a SV procedure , who showed a mean value of 3.5 (SD: 2.1); (p < 0.045). Conclusions: Patients having underwent bypass and IMA procedures perceive more pain than in other cardiac surgery and graft interventions

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Melanoma is one of the most aggressive types of skin cancer and its incidence rate is still increasing. All existing treatments are minimally effective. Consequently, new therapeutic agents for melanoma treatment should be developed. The DM-1 compound is a curcumin analog that possesses several curcumin characteristics, such as antiproliferative, antitumor, and anti-metastatic properties. The aim of this study was to evaluate the different signaling pathways involved in the cytotoxic effect of DM-1 on melanoma cells. The apoptotic process and cytoskeletal changes were evaluated by immunoblotting and immunofluorescence, respectively, in melanoma cells. After DM-1 treatment, SK-MEL-5 melanoma cells showed actin filament disorganization with spicule formation throughout the cytoskeleton and significant reduction of focal adhesion as well as they were present only at cell extremities, conferring a poor connection between the cell and the substrate. Besides this, there was significant filopodium retraction and loss of typical cytoskeleton scaffold. These modifications contributed to cell detachment followed by cell death. Furthermore, DM-1-induced apoptosis was triggered by multiple Bcl-2 proteins involved in both the extrinsic and the intrinsic apoptotic pathways. SK-MEL-5 cells showed a death mechanism mainly by Bcl-2/Bax ratio decrease, whereas A375 cells presented apoptosis induction by Mcl-1 and Bcl-xL downregulation. In SK-MEL-5 and A375 melanoma cells, there was a significant increase in the active form of caspase 9, and the inactive form of the effector caspase 3 was decreased in both cell lines. Expression of cleaved poly ADP ribose polymerase was increased after DM-1 treatment in these melanoma cell lines, demonstrating that the apoptotic process occurred. Altogether, these data elucidate the cellular and molecular mechanisms involved in the cytotoxicity induced by the antitumor agent DM-1 in melanoma cells.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Le but de cette étude était d'investiguer l'association entre l'alliance thérapeutique et le contrôle de substances, comme il est vécu par le patient. La théorie de King et le concept de l'alliance thérapeutique figuraient comme cadres théoriques. L'investigation se faisait à l'aide d'un questionnaire auto-administré, incluant l'instrument working alliance inventory (WAI) dans sa forme abréviée, traduit et validé en français, visant un échantillon de convenance (n=28). L'alliance thérapeutique était évaluée sur une échelle Likert à 12 questions, et les alliances thérapeutiques se sont révélées comme bonnes (x=61.68, max=84). Mais il y a une relation linéaire négative significative entre le degré à quel point les contrôles sont perçus comme pesants, évalués par une question supplémentaire sur une visual analog scale (VAS), et l'établissement d'une alliance thérapeutique (r =-0.67, p-value>0.001). De plus, la forme d'admission joue un rôle significatif, car dans cette étude, les patients admis sous pression de l'extérieur (n=7) ont de moins bonnes alliances (t, p-value=0.018) et vivent les contrôles comme plus pesants (Z, p-value=0.004) que les patients admis de leur propre gré (n=21). Malgré que ces résultats ne sont, vu le petit échantillon (n=28), pas généralisables, ils pourraient impliquer pour la pratique de repenser la prise d'urine et d'être sensibilisés aux conséquences possibles. Des options, comme l'introduction d'une supervision par caméra ou le retrait complet de l'infirmière de référence de toute sorte de contrôles, seraient imaginables. Au moins pour les personnes hospitalisées sous pression de l'extérieur et qui sont probablement, pour cette raison, plus susceptibles à tout dérangement de la relation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A piezoelectric detector based on a commercial quartz crystal of 3.57MHz is shown. A PTFE cell attached to the GC-column outlet holds the polymer-coated crystal, whose terminals were removed. Two TTL oscillators (reference and sensor) are used and the beating of their frequencies is monitored through a home-made counter card inserted in a microcomputer. The original thermal conductivity detector was also interfaced, but through a 12-bit analog-to-digital converter. In spite of the well-known fact that QCM has low sensitivity at high temperatures, results show significant peak deformation for low temperatures. In addition, the phenomenon is also dependent on the chemical composition of the absorbent film besides instantaneous partial pressure and chemical composition of the analyte.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Antimicrobial peptides offer a new class of therapeutic agents to which bacteria may not be able todevelop genetic resistance, since their main activity is in the lipid component of the bacterial cell mem-brane. We have developed a series of synthetic cationic cyclic lipopeptides based on natural polymyxin,and in this work we explore the interaction of sp-85, an analog that contains a C12 fatty acid at theN-terminus and two residues of arginine. This analog has been selected from its broad spectrum antibac-terial activity in the micromolar range, and it has a disruptive action on the cytoplasmic membrane ofbacteria, as demonstrated by TEM. In order to obtain information on the interaction of this analog withmembrane lipids, we have obtained thermodynamic parameters from mixed monolayers prepared withPOPG and POPE/POPG (molar ratio 6:4), as models of Gram positive and Gram negative bacteria, respec-tively. LangmuirBlodgett films have been extracted on glass plates and observed by confocal microscopy,and images are consistent with a strong destabilizing effect on the membrane organization induced bysp-85. The effect of sp-85 on the membrane is confirmed with unilamelar lipid vesicles of the same com-position, where biophysical experiments based on fluorescence are indicative of membrane fusion andpermeabilization starting at very low concentrations of peptide and only if anionic lipids are present.Overall, results described here provide strong evidence that the mode of action of sp-85 is the alterationof the bacterial membrane permeability barrier.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A digital multimeter (~U$ 240.00 on the national market) connected to a microcomputer by a RS-232 serial interface is proposed for data acquisition in equipment with analog output. Data are measured at the rate of 2 points per second and stored in text files by the software that accompanies the device, running in a Windows environment. The performance of the multimeter was verified by monitoring the transient signals generated in flow injection systems associated with fluorimetric, spectrophotometric and flame photometric detection. In addition, the performance of the proposed device was similar to that attained by employing an interface card with a 12-bit analog-to-digital converter for acquisition of the signals generated by a capillary electrophoresis equipment with oscillometric detection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A lab-made interface for acquisition of instrumental analog signals between 0 and 5 V at a frequency up to 670 kHz at the parallel port of a microcomputer is described. Since it uses few and small components, it was built into the connector of a printer parallel cable. Its performance was evaluated by monitoring the signals of four different instruments and similar analytical curves were obtained with the interface and from readings from the instrument' displays. Because the components are cheap (~U$35,00) and easy to get, the proposed interface is a simple and economical alternative for data acquisition in small laboratories for routine work, research and teaching.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Galactic microquasars are certainly one of the most recent additions to the field of high energy Astrophysics. These new objects are just X-ray binaries with the ability to generate relativistic jets and their interest has been growing during the last decade. Today, they represent primary targets for all space based observatories working in the X-ray and [gamma]-ray domains. Behind such interest, there is hope that their study will assist us to understand some of the analog phenomena observed in distant quasars and active galactic nuclei, wich share with microquasars practically the same scaled-up physics. Microquasars are also believed to be among the different kind of sources responsible for the violent and ever changing appearance of the [gamma]-ray ski. In this paper we review the general situation of the microquasar topic, their identification and study, including comments on the recent observational and theoretical discoveries most relevant in our opinion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Poder mesurar i enregistrar diferents tipus de magnituds com pressió, força, temperatura etc. s’ha convertit en una necessitat per moltes aplicacions actuals. Aquestes magnituds poden tenir procedències molt diverses, tals com l’entorn, o poden ser generades per sistemes mecànics, elèctrics, etc. Per tal de poder adquirir aquestes magnituds, s’utilitzen els sistemes d’adquisició de dades. Aquests sistemes, prenen mostres analògiques del món real, i les transformen en dades digitals que poden ser manipulades per un sistema electrònic. Pràcticament qualsevol magnitud es pot mesurar utilitzant el sensor adient. Una magnitud molt utilitzada en sistemes d’adquisició de dades, és la temperatura. Els sistemes d’adquisició de temperatures estan molt generalitzats, i podem trobar-los com a sistemes, on l’objectiu és mostrar les dades adquirides, o podem trobar-los formant part de sistemes de control, aportant uns inputs necessaris per el seu correcte funcionament, garantir-ne l’estabilitat, seguretat etc. Aquest projecte, promogut per l’empresa Elausa, s’encarregarà d’adquirir, el senyal d’entrada de 2 Termoparells. Aquests mesuraran temperatures de circuits electrònics, que es trobaran dintre la càmera climàtica de Elausa, sotmesos a diferents condicions de temperatura, per tal de rebre l’homologació del circuit. El sistema haurà de poder mostrar les dades adquirides en temps real, i emmagatzemar-les en un PC que estarà ubicat en una oficina, situada a uns 30 m de distància de la sala on es farà el test. El sistema constarà d’un circuit electrònic que adquirirà, i condicionarà el senyal de sortida dels termoparells, per adaptar-lo a la tensió d’entrada d’un convertidor analògic digital, del microcontrolador integrat en aquesta placa. Seguidament aquesta informació, s’enviarà a través d’un mòdul transmissor de radiofreqüència, cap al PC on es visualitzaran les dades adquirides. Els objectius plantejats són els següents: - Dissenyar el circuit electrònic d’adquisició i condicionament del senyal. - Dissenyar, fabricar i muntar el circuit imprès de la placa d’adquisició. - Realitzar el programa de control del microcontrolador. - Realitzar el programa per presentar i desar les dades en un PC. - El sistema ha d’adquirir 2 temperatures, a través de Termoparells amb un rang d’entrada de -40ºC a +240ºC - S’ha de transmetre les dades via R.F. Els resultats del projecte han estat satisfactoris i s’han complert els objectius plantejats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cyclolignan (+)-lyoniresinol (1), veratric acid (2), vanillic acid (3), lupeol, oleanolic acid, 3β-hydroxy-urs-11-en-28,13β-lactone (4), the mixture of α- and β-amyrin, trans-polyisoprene, and β-sitosterol were isolated from the leaves of Maytenus phyllanthoides. The structures of the isolated compounds were established based on spectroscopic data, mainly ¹H and 13C nuclear magnetic resonance (NMR). Compound 1, its acetate analog 1a, and compounds 2, 3, and 4 were tested against Trichomonas vaginalis. (+)-Lyoniresinol showed activity corresponding to IC50 17.57 µM. This is the first report on the occurrence of 3β-hydroxy-urs-11-en-28,13β-lactone (4) in the Celastraceous family and lyoniresinol in the Maytenus genus, and on the antitrichomonal activity of lyoniresinol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Työssä suunnitellaan kierrosnopeusmittauksen toteutus vanhaan Ford -teollisuusdieseliin käyttäen moottorin alkuperäistä kierrosnopeusanturia. Anturi kunnostetaan vaihtamalla vanha, palanut käämi uuteen digitaaliseen järjestelmään soveltuvaan käämiin. Sen toimin-ta halutulla kierrosnopeusalueella varmistetaan mittauksin ja tämän perusteella suunnitel-laan kytkentä sen liittämiseksi kierrosnopeuden laskevaan mikrokontrolleriin. Kytkennän toimivuutta testataan simuloimalla ennen prototyypin rakentamista. Erilaisia vaihtoehtoja analogisen näytön toteuttamiseksi tutkitaan ja niistä valitaan yksi ve-nekäyttöön soveltuva, joka toteutetaan järjestelmän näyttöratkaisuksi. Järjestelmälle suunnitellaan piirilevy, jolle prototyyppi kasataan. Mikrokontrollerille koodataan C -ohjelmointikielellä ohjelma, joka laskee dieselmoottorin kierrosnopeuden anturipulssien perusteella ja ohjaa näyttöä.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Erotusvahvistin on instrumentointivahvistin, jonka tulo ja lähtö ovat galvaanisesti erotettu toisistaan. Erotusvahvistimia käytetään galvaanista erotusta vaativissa sovelluksissa, muun muassa sairaalalaitteissa. Teollisuudessa on olemassa sovelluksia, joihin tarvittaisiin analogisia erotusvahvistimia, mutta ei tiedetä onko analogisilla erotusvahvistimilla riittävän hyvät komponenttiarvot. Tässä työssä selvitetään analogisten erotusvahvistimien tämänhetkisiä ominaisuuksia, hintoja ja komponenttiarvoja neljältä eri valmistajalta.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work parameters of Mg-doped GaN samples were studied using positron annihilation spectroscopy and analyzed. It is shown that gallium vacancies exist in an unintentionally doped sample. Next, the sample with higher concentration of Mg and low growth temperature contains vacancy clusters. In case of low concentration of Mg the growth temperature does not affect the formation of defects. Analog electronics can be replaced by a modern digital device. While promising a high quantity of benefits, the performance of these digitizers requires thorough adjustment. A 14-bit two channel digitizer has been tested in order to achieve better performance than the one of a traditional analog setup, and the adjustment process is described. It has been shown that the digital device is unable to achieve better energy resolution, but it is quite close to the corresponding attribute of the available analog system, which had been used for measurements in Mg-doped GaN.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Memristive computing refers to the utilization of the memristor, the fourth fundamental passive circuit element, in computational tasks. The existence of the memristor was theoretically predicted in 1971 by Leon O. Chua, but experimentally validated only in 2008 by HP Labs. A memristor is essentially a nonvolatile nanoscale programmable resistor — indeed, memory resistor — whose resistance, or memristance to be precise, is changed by applying a voltage across, or current through, the device. Memristive computing is a new area of research, and many of its fundamental questions still remain open. For example, it is yet unclear which applications would benefit the most from the inherent nonlinear dynamics of memristors. In any case, these dynamics should be exploited to allow memristors to perform computation in a natural way instead of attempting to emulate existing technologies such as CMOS logic. Examples of such methods of computation presented in this thesis are memristive stateful logic operations, memristive multiplication based on the translinear principle, and the exploitation of nonlinear dynamics to construct chaotic memristive circuits. This thesis considers memristive computing at various levels of abstraction. The first part of the thesis analyses the physical properties and the current-voltage behaviour of a single device. The middle part presents memristor programming methods, and describes microcircuits for logic and analog operations. The final chapters discuss memristive computing in largescale applications. In particular, cellular neural networks, and associative memory architectures are proposed as applications that significantly benefit from memristive implementation. The work presents several new results on memristor modeling and programming, memristive logic, analog arithmetic operations on memristors, and applications of memristors. The main conclusion of this thesis is that memristive computing will be advantageous in large-scale, highly parallel mixed-mode processing architectures. This can be justified by the following two arguments. First, since processing can be performed directly within memristive memory architectures, the required circuitry, processing time, and possibly also power consumption can be reduced compared to a conventional CMOS implementation. Second, intrachip communication can be naturally implemented by a memristive crossbar structure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To determine whether paraspinal block reduces pain scores compared to placebo in women with chronic pelvic pain refractory to drug therapy.METHODS: Subjects with chronic pelvic pain due to benign conditions and refractory to drug therapy were invited to participate in a randomized, double blind, superiority trial at a tertiary reference center. Subjects were randomly allocated to receive paraspinal anesthetic block with 1% lidocaine without epinephrine or placebo (control). Lidocaine was injected along the spinal process of the painful segment in the supra- and interspinal ligaments using a 25G X 2" needle. Placebo consisted of introduction of the needle in the same segment without injecting any substance. The main outcome measured was the pain score based on a visual analog scale at T0 (baseline), T1 (within 15 min after the procedure) and T2 (one week after the procedure). Data were statistically analyzed by ANOVA and the 95% confidence interval (95%CI).RESULTS: Mean age was similar for both groups, i.e., 51.2 (paraspinal anesthetic block) and 51.8 years (control). A blind examiner measured the degree of pain according to the visual analog scale from 0 (no pain) to 10 (worst pain imaginable). Based on the visual analog scale, the mean pain scores of the paraspinal anesthetic block group at T0, T1 and T2 were 5.50 (SD=2.92; 95%CI 3.84-7.15), 2.72 (SD=2.10; 95%CI 1.53-3.90), and 4.36 (SD=2.37; 95%CI 1.89-6.82), respectively. The difference between T0 and T1 was statistically significant, with p=0.03.CONCLUSIONS:Paraspinal anesthetic block had a small effect on visual analog scale pain score immediately after the injections, but no sustained benefit after one week. Further studies are needed to determine the efficacy of paraspinal anesthetic block with different lidocaine doses for the treatment of visceral pain of other causes.