977 resultados para unknown input functional observers


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports a system decomposition that allows the construction of a minimum-order functional observer using a state observer design approach. The system decomposition translates the functional observer design problem to that of a state observer for a smaller decomposed subsystem. Functional observability indices are introduced, and a closed-form expression for the minimum order required for a functional observer is derived in terms of those functional observability indices. © 2014 Taylor & Francis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a method for designing residual generators using minimum-order functional observers to detect actuator and component faults in time-delay systems. Existence conditions of the residual generators and functional observers are first derived, and then based on a parametric approach to the solution of a generalized Sylvester matrix equation, we develop systematic procedures for designing minimum-order functional observers to detect faults in the system. The advantages of having minimum-order observers are obvious from the economical and practical points of view as cost saving and simplicity can be achieved, particularly when dealing with high-order complex systems. Extensive numerical examples are given to illustrate the proposed fault detection scheme. In all the numerical examples, we design minimum-order residual generators and functional observers to detect faults in the system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The direct approach in designing functional observers was first presented in [1] for estimating a single function of the states of a Linear Time-Invariant (LTI) system. One of the benefits of the direct scheme is that it does not require solving the interconnected Sylvester equations that appear in the other observer design approaches. In the present paper, the direct approach is extended to reconstruct multiple functions of the states in such a way that the minimum possible order of the observer is achieved. The observer is designed so that an asymptotic functional observer can be obtained with arbitrary convergence rate. In the proposed methodology, it is not necessary that a reduced order observer exists for the desired functions to be estimated. To release this limitation, an algorithm is employed to find some auxiliary functions in the minimum required number to be appended to the desired functions. This method assumes that the system is functional observable. This assumption however is less restrictive than the observability and detectability conditions of the system. A numerical example and simulation results explain the efficacy and the benefits of the proposed algorithm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a load frequency control scheme using electric vehicles (EVs) to help thermal turbine units to provide the stability fluctuated by load demands. First, a general framework for deriving a state-space model for general power system topologies is given. Then, a detailed model of a four-area power system incorporating a smart and renewable discharged EVs system is presented. The areas within the system are interconnected via a combination of alternating current/high voltage direct current links and thyristor controlled phase shifters. Based on some recent development on functional observers, novel distributed functional observers are designed, one at each local area, to implement any given global state feedback controller. The designed observers are of reduced order and dynamically decoupled from others in contrast to conventional centralized observer (CO)-based controllers. The proposed scheme can cope better against accidental failures than those CO-based controllers. Extensive simulations and comparisons are given to show the effectiveness of the proposed control scheme.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This brief considers a new problem of designing reduced-order positive linear functional observers for positive time-delay systems. The order of the designed functional observers is equal to the dimension of the functional state vector to be estimated. The designed functional observers always nonnegative at any time and they converge asymptotically to the true functional state vector. Moreover, conditions for the existence of such positive linear functional observers are formulated in terms of linear programming (LP). Numerical examples and simulation results are given to illustrate the effectiveness of the proposed design method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents new developments in common functional observers for two systems. We improve an existing common functional observer scheme by reducing its order, and then investigate its existence conditions in terms of the original system matrices. These conditions have never been explored and they enable the users to know at the outset the class of systems for which the scheme is applicable. They also show that both observers can be designed independently of each other which significantly simplifies the design process. A numerical simulation verifies the findings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper considers the design of a common linear functional observer for two linear time-invariant systems with unknown inputs. A structure for a common observer which only uses the available output information is proposed. Here, for the proposed structure, we show that the simultaneous functional observation problem of two plants is reduced to a problem of designing two observers: the first is a full-order unknown input observer of one of the two systems; the second observer is a common unknown input observer of a system comprises two-connected systems. In general, the existence conditions for the second observer are very difficult to satisfy. This paper thus concludes that it is indeed very difficult to find a common observer for two linear systems with unknown inputs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This note deals with the design of reduced-order disturbance decoupled scalar functional observers for linear systems with unknown inputs. Based on a parametric approach, existence conditions are derived and a design procedure for finding reduced-order scalar functional observers is given. The derived existence conditions are relaxed and the procedure can find first-order disturbance decoupled scalar functional observers for some cases where the number of unknown inputs is more than the number of outputs. Also, the observer matching condition, which is the necessary requirement for the design of state observers for linear systems with unknown inputs, is not required. Numerical examples are given to illustrate the attractiveness of the proposed design method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a solution to the problem of designing a common linear functional observer that can observe a partial set of the state vector of two linear systems with unknown inputs. A new structure of a decoupled linear functional observer is proposed for systems subject unknown disturbances, using only the available output information. Existence conditions as well as a design procedure are given for constructing the proposed observer. A numerical example is given to illustrate the effectiveness of the new observer structure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A delay-dependent functional observer is designed for linear time-invariant (LTI) systems with time-varying input delay. Compared to delay-free observers, delay-dependent functional observers are less conservative and cover more systems. The designed functional observer is with minimum possible order (minimal). Necessary and sufficient conditions of the existence of the observer and asymptomatic stability of it are illustrated. The proposed observer is extended to multiple input delayed systems with time-varying delays. An algorithm is developed for designing of the minimal order observer based on the methodology of this paper. Two numerical examples and simulations are used to support our proposed methodology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper examines the design of minimal-order residual generators for the purpose of detecting and isolating actuator and/or component faults in dynamical systems. We first derive existence conditions and design residual generators using only first-order observers to detect and identify the faults. When the first-order functional observers do not exist, then based on a parametric approach to the solution of a generalized Sylvester matrix equation, we develop systematic procedures for designing residual generators utilizing minimal-order functional observers. Our design approach gives lower-order residual generators than existing results in the literature. The advantages for having such lower-order residual generators are obvious from the economical and practical points of view as cost saving and simplicity in implementation can be achieved, particularly when dealing with high-order complex systems. Numerical examples are given to illustrate the proposed fault detection and isolation schemes. In all of the numerical examples, we design minimum-order residual generators to effectively detect and isolate actuator and/or component faults in the system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents necessary and sufficient conditions for the existence of a reduced-order linear functional state observer for linear stochastic systems. The order of the observer is the same as the dimension of the vectors to be estimated. A simple design algorithm is given together with a numerical example to illustrate the simplicity of the design procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Functional observers estimate a linear function of the state vector directly without having to estimate all the individual states. In the past various observer structures have been employed to design such functional estimates. In this paper we discuss the generality of those various observer structures and prove the conditions under which those observer structures are unified. The paper also highlights and clarifies the need to remove the self-convergent states from the system and also from the functions to be estimated before proceeding with the design of a functional observer or else incorrect conclusions regarding the existence of functional observers can be arrived at.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new problem on ε-bounded functional state estimation for time-delay systems with unknown bounded disturbances is studied in this paper. In the presence of unknown bounded disturbances, the common assumption regarding the observers matching condition is no longer required. In this regard, instead of achieving asymptotic convergence for the observer error, the error is now required to converge exponentially within a ball with a small radius ε > 0. This means that the estimate converges exponentially within an ε-bound of the true value. A general observer that utilises multiple-delayed output and input information is proposed. Sufficient conditions for the existence of the proposed observer are first given. We then employ an extended Lyapunov-Krasovskii functional which combines the delay-decomposition technique with a triple-integral term to study the ε-convergence problem of the observer error system. Moreover, the obtained results are shown to be more effective than the existing results for the cases with no disturbances and/or no time delay. Three numerical examples are given to illustrate the obtained results.