989 resultados para turbine inlet temperature
Resumo:
In this work, experimental results are reported for a small scale cogeneration plant for power and refrigeration purposes. The plant includes a natural gas microturbine and an ammonia/water absorption chiller fired by steam. The system was tested under different turbine loads, steam pressures and chiller outlet temperatures. An evaluation based on the 1st and 2nd Laws of Thermodynamics was also performed. For the ambient temperature around 24°C and microturbine at full load, the plant is able to provide 19 kW of saturated steam at 5.3 bar (161 °C), corresponding to 9.2 kW of refrigeration at -5 °C (COP = 0.44). From a 2nd law point-of-view, it was found that there is an optimal chiller outlet temperature that maximizes the chiller exergetic efficiency. As expected, the microturbine presented the highest irreversibilities, followed by the absorption chiller and the HRSG. In order to reduce the plant exergy destruction, it is recommended a new design for the HRSG and a new insulation for the exhaust pipe. © 2013 Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The effects of drying air inlet temperature (IT) and concentration of Aerosil 200 (C-A) on several properties of spray-dried Apeiba tibourbou extracts were investigated following a 3(2) full factorial design. Powder recovery varied from 9.83 to 46.95% and dried products showed moisture contents below 7%. Although the spray-dried products lost some of their polyphenols, they still present excellent antioxidant activity, opening perspectives for its use to medicinal purpose. C-A exerted a key role on the properties of spray-dried extracts, while IT did not present a significative influence. Aerosil (R) 200 proved to be an interesting alternative as an excipient for the drying of the herbal extract, even at intermediate concentrations such as 15%. The best combination of conditions to use for obtaining dry A. tibourbou extracts with adequate physicochemical and functional properties involves an IT of 100 degrees C and a C-A of 15%.
Resumo:
Microparticles of ketoprofen entrapped in blends of acrylic resins (Eudragit RL 30D and RS 30D) were successfully produced by spray drying. The effects of the proportion ketoprofen : polymer (1: 1 and 1: 3) and of spray-drying parameters (drying gas inlet temperatures of 80 and 100 degrees C; microencapsulating composition feed flow rates of 4 and 6 g/min) on the microparticles properties (drug content, encapsulation efficiency, mean particle size, moisture content, and dissolution behavior) were evaluated. Differential scanning calorimetry (DSC) thermograms and X-ray diffractograms of the spray-dried product, the free drug, and the physical mixture between the free drug and spray-dried composition (blank) were carried out. Microparticles obtained at inlet temperature of 80 degrees C, feed flow rate of 4 g/min, and ketoprofen : acrylic resin ratio of 1: 3 presented an encapsulation efficiency of 88.1%, moisture content of 5.8%, production yield around 50%, and a higher reduction in dissolution rate of the entrapped ketoprofen. Sigmoidal shape dissolution profiles were presented by the spray-dried microparticles. The dissolution profiles were relatively well described by the Weibull model, a showing high coefficient of determination, R-2, and a mean absolute error between experimental and estimated values of between 4.6 and 10.1%.
Resumo:
In der Herstellung fester Darreichungsformen umfasst die Granulierung einen komplexen Teilprozess mit hoher Relevanz für die Qualität des pharmazeutischen Produktes. Die Wirbelschichtgranulierung ist ein spezielles Granulierverfahren, welches die Teilprozesse Mischen, Agglomerieren und Trocknen in einem Gerät vereint. Durch die Kombination mehrerer Prozessstufen unterliegt gerade dieses Verfahren besonderen Anforderungen an ein umfassendes Prozessverständnis. Durch die konsequente Verfolgung des PAT- Ansatzes, welcher im Jahre 2004 durch die amerikanische Zulassungsbehörde (FDA) als Guideline veröffentlicht wurde, wurde der Grundstein für eine kontinuierliche Prozessverbesserung durch erhöhtes Prozessverständnis, für Qualitätserhöhung und Kostenreduktion gegeben. Die vorliegende Arbeit befasste sich mit der Optimierung der Wirbelschicht-Granulationsprozesse von zwei prozesssensiblen Arzneistoffformulierungen, unter Verwendung von PAT. rnFür die Enalapril- Formulierung, einer niedrig dosierten und hochaktiven Arzneistoffrezeptur, wurde herausgefunden, dass durch eine feinere Zerstäubung der Granulierflüssigkeit deutlich größere Granulatkörnchen erhalten werden. Eine Erhöhung der MassRatio verringert die Tröpfchengröße, dies führt zu größeren Granulaten. Sollen Enalapril- Granulate mit einem gewünschten D50-Kornverteilung zwischen 100 und 140 um hergestellt werden, dann muss die MassRatio auf hohem Niveau eingestellt werden. Sollen Enalapril- Granulate mit einem D50- Wert zwischen 80 und 120µm erhalten werden, so muss die MassRatio auf niedrigem Niveau eingestellt sein. Anhand der durchgeführten Untersuchungen konnte gezeigt werden, dass die MassRatio ein wichtiger Parameter ist und zur Steuerung der Partikelgröße der Enalapril- Granulate eingesetzt werden kann; unter der Voraussetzung dass alle anderen Prozessparameter konstant gehalten werden.rnDie Betrachtung der Schnittmengenplots gibt die Möglichkeit geeignete Einstellungen der Prozessparameter bzw. Einflussgrößen zu bestimmen, welche dann zu den gewünschten Granulat- und Tabletteneigenschaften führen. Anhand der Lage und der Größe der Schnittmenge können die Grenzen der Prozessparameter zur Herstellung der Enalapril- Granulate bestimmt werden. Werden die Grenzen bzw. der „Design Space“ der Prozessparameter eingehalten, kann eine hochwertige Produktqualität garantiert werden. rnUm qualitativ hochwertige Enalapril Tabletten mit der gewählten Formulierung herzustellen, sollte die Enalapril- Granulation mit folgenden Prozessparametern durchgeführt werden: niedrige Sprührate, hoher MassRatio, einer Zulufttemperatur von mindestens > 50 °C und einer effektiven Zuluftmenge < 180 Nm³/h. Wird hingegen eine Sprührate von 45 g/min und eine mittlere MassRatio von 4.54 eingestellt, so muss die effektive Zuluftmenge mindestens 200 Nm³/h und die Zulufttemperatur mindestens 60 °C betragen, um eine vorhersagbar hohe Tablettenqualität zu erhalten. Qualität wird in das Arzneimittel bereits während der Herstellung implementiert, indem die Prozessparameter bei der Enalapril- Granulierung innerhalb des „Design Space“ gehalten werden.rnFür die Metformin- Formulierung, einer hoch dosierten aber wenig aktiven Arzneistoffrezeptur wurde herausgefunden, dass sich der Wachstumsmechanismus des Feinanteils der Metformin- Granulate von dem Wachstumsmechanismus der D50- und D90- Kornverteilung unterscheidet. Der Wachstumsmechanismus der Granulate ist abhängig von der Partikelbenetzung durch die versprühten Flüssigkeitströpfchen und vom Größenverhältnis von Partikel zu Sprühtröpfchen. Der Einfluss der MassRatio ist für die D10- Kornverteilung der Granulate vernachlässigbar klein. rnMit Hilfe der Störgrößen- Untersuchungen konnte eine Regeleffizienz der Prozessparameter für eine niedrig dosierte (Enalapril)- und eine hoch dosierte (Metformin) Arzneistoffformulierung erarbeitet werden, wodurch eine weitgehende Automatisierung zur Verringerung von Fehlerquellen durch Nachregelung der Störgrößen ermöglicht wird. Es ergibt sich für die gesamte Prozesskette ein in sich geschlossener PAT- Ansatz. Die Prozessparameter Sprührate und Zuluftmenge erwiesen sich als am besten geeignet. Die Nachregelung mit dem Parameter Zulufttemperatur erwies sich als träge. rnFerner wurden in der Arbeit Herstellverfahren für Granulate und Tabletten für zwei prozesssensible Wirkstoffe entwickelt. Die Robustheit der Herstellverfahren gegenüber Störgrößen konnte demonstriert werden, wodurch die Voraussetzungen für eine Echtzeitfreigabe gemäß dem PAT- Gedanken geschaffen sind. Die Kontrolle der Qualität des Produkts findet nicht am Ende der Produktions- Prozesskette statt, sondern die Kontrolle wird bereits während des Prozesses durchgeführt und basiert auf einem besseren Verständnis des Produktes und des Prozesses. Außerdem wurde durch die konsequente Verfolgung des PAT- Ansatzes die Möglichkeit zur kontinuierlichen Prozessverbesserung, zur Qualitätserhöhung und Kostenreduktion gegeben und damit das ganzheitliche Ziel des PAT- Gedankens erreicht und verwirklicht.rn
Resumo:
Due to their high thermal efficiency, diesel engines have excellent fuel economy and have been widely used as a power source for many vehicles. Diesel engines emit less greenhouse gases (carbon dioxide) compared with gasoline engines. However, diesel engines emit large amounts of particulate matter (PM) which can imperil human health. The best way to reduce the particulate matter is by using the Diesel Particulate Filter (DPF) system which consists of a wall-flow monolith which can trap particulates, and the DPF can be periodically regenerated to remove the collected particulates. The estimation of the PM mass accumulated in the DPF and total pressure drop across the filter are very important in order to determine when to carry out the active regeneration for the DPF. In this project, by developing a filtration model and a pressure drop model, we can estimate the PM mass and the total pressure drop, then, these two models can be linked with a regeneration model which has been developed previously to predict when to regenerate the filter. There results of this project were: 1 Reproduce a filtration model and simulate the processes of filtration. By studying the deep bed filtration and cake filtration, stages and quantity of mass accumulated in the DPF can be estimated. It was found that the filtration efficiency increases faster during the deep-bed filtration than that during the cake filtration. A “unit collector” theory was used in our filtration model which can explain the mechanism of the filtration very well. 2 Perform a parametric study on the pressure drop model for changes in engine exhaust flow rate, deposit layer thickness, and inlet temperature. It was found that there are five primary variables impacting the pressure drop in the DPF which are temperature gradient along the channel, deposit layer thickness, deposit layer permeability, wall thickness, and wall permeability. 3 Link the filtration model and the pressure drop model with the regeneration model to determine the time to carry out the regeneration of the DPF. It was found that the regeneration should be initiated when the cake layer is at a certain thickness, since a cake layer with either too big or too small an amount of particulates will need more thermal energy to reach a higher regeneration efficiency. 4 Formulate diesel particulate trap regeneration strategies for real world driving conditions to find out the best desirable conditions for DPF regeneration. It was found that the regeneration should be initiated when the vehicle’s speed is high and during which there should not be any stops from the vehicle. Moreover, the regeneration duration is about 120 seconds and the inlet temperature for the regeneration is 710K.
Resumo:
Direct Steam Generation (DSG) in Linear Fresnel (LF) solar collectors is being consolidated as a feasible technology for Concentrating Solar Power (CSP) plants. The competitiveness of this technology relies on the following main features: water as heat transfer fluid (HTF) in Solar Field (SF), obtaining high superheated steam temperatures and pressures at turbine inlet (500ºC and 90 bar), no heat tracing required to avoid HTF freezing, no HTF degradation, no environmental impacts, any heat exchanger between SF and Balance Of Plant (BOP), and low cost installation and maintenance. Regarding to LF solar collectors, were recently developed as an alternative to Parabolic Trough Collector (PTC) technology. The main advantages of LF are: the reduced collector manufacturing cost and maintenance, linear mirrors shapes versus parabolic mirror, fixed receiver pipes (no ball joints reducing leaking for high pressures), lower susceptibility to wind damages, and light supporting structures allowing reduced driving devices. Companies as Novatec, Areva, Solar Euromed, etc., are investing in LF DSG technology and constructing different pilot plants to demonstrate the benefits and feasibility of this solution for defined locations and conditions (Puerto Errado 1 and 2 in Murcia Spain, Lidellin Newcastle Australia, Kogran Creek in South West Queensland Australia, Kimberlina in Bakersfield California USA, Llo Solar in Pyrénées France,Dhursar in India,etc). There are several critical decisions that must be taken in order to obtain a compromise and optimization between plant performance, cost, and durability. Some of these decisions go through the SF design: proper thermodynamic operational parameters, receiver material selection for high pressures, phase separators and recirculation pumps number and location, pipes distribution to reduce the amount of tubes (reducing possible leaks points and transient time, etc.), etc. Attending to these aspects, the correct design parameters selection and its correct assessment are the main target for designing DSG LF power plants. For this purpose in the recent few years some commercial software tools were developed to simulatesolar thermal power plants, the most focused on LF DSG design are Thermoflex and System Advisor Model (SAM). Once the simulation tool is selected,it is made the study of the proposed SFconfiguration that constitutes the main innovation of this work, and also a comparison with one of the most typical state-of-the-art configuration. The transient analysis must be simulated with high detail level, mainly in the BOP during start up, shut down, stand by, and partial loads are crucial, to obtain the annual plant performance. An innovative SF configurationwas proposed and analyzed to improve plant performance. Finally it was demonstrated thermal inertia and BOP regulation mode are critical points in low sun irradiation day plant behavior, impacting in annual performance depending on power plant location.
Resumo:
High pressure homogenisation (HPH) is a novel dairy processing tool, which has many effects on enzymes, microbes, fat globules and proteins in milk. The effects of HPH on milk are due to a combination of shear forces and frictional heating of the milk during processing; the relative importance of these different factors is unclear, and was the focus of this study. The effect of milk inlet temperature (in the range 10-50 degrees C) on residual plasmin, alkaline phosphatase, lactoperoxidase and lipase activities in raw whole bovine milk homogenised at 200 MPa was investigated. HPH caused significant heating of the milk; outlet temperature increased in a linear fashion (0(.)5887 degrees C/degrees C, R-2 =0-9994) with increasing inlet temperature. As milk was held for 20 s at the final temperature before cooling, samples of the same milk were heated isothermally in glass capillary tubes for the same time/temperature combinations. Inactivation profiles of alkaline phosphatase in milk were similar for isothermal heating or HPH, indicating that loss of enzyme activity was due to heating alone. Loss of plasmin and lactoperoxidase activity in HPH milk, however, was greater than that in heated milk. Large differences in residual lipase activities in milks subjected to heating or HPH were observed due to the significant increase in lipase activity in homogenised milk. Denaturation of beta-lactoglobulin was more extensive following HPH than the equivalent heat treatment. Inactivation of plasmin was correlated with increasing fat/serum interfacial area but was not correlated with denaturation of beta-lactoglobulin. Thus, while some effects of HPH on milk are due to thermal effects alone, many are induced by the combination of forces and heating to which the milk is exposed during HPH.
Resumo:
Experimental investigations and computer modelling studies have been made on the refrigerant-water counterflow condenser section of a small air to water heat pump. The main object of the investigation was a comparative study between the computer modelling predictions and the experimental observations for a range of operating conditions but other characteristics of a counterflow heat exchanger are also discussed. The counterflow condenser consisted of 15 metres of a thermally coupled pair of copper pipes, one containing the R12 working fluid and the other water flowing in the opposite direction. This condenser was mounted horizontally and folded into 0.5 metre straight sections. Thermocouples were inserted in both pipes at one metre intervals and transducers for pressure and flow measurement were also included. Data acquisition, storage and analysis was carried out by a micro-computer suitably interfaced with the transducers and thermocouples. Many sets of readings were taken under a variety of conditions, with air temperature ranging from 18 to 26 degrees Celsius, water inlet from 13.5 to 21.7 degrees, R12 inlet temperature from 61.2 to 81.7 degrees and water mass flow rate from 6.7 to 32.9 grammes per second. A Fortran computer model of the condenser (originally prepared by Carrington[1]) has been modified to match the information available from experimental work. This program uses iterative segmental integration over the desuperheating, mixed phase and subcooled regions for the R12 working fluid, the water always being in the liquid phase. Methods of estimating the inlet and exit fluid conditions from the available experimental data have been developed for application to the model. Temperature profiles and other parameters have been predicted and compared with experimental values for the condenser for a range of evaporator conditions and have shown that the model gives a satisfactory prediction of the physical behaviour of a simple counterflow heat exchanger in both single phase and two phase regions.
Resumo:
A study on heat pump thermodynamic characteristics has been made in the laboratory on a specially designed and instrumented air to water heat pump system. The design, using refrigerant R12, was based on the requirement to produce domestic hot water at a temperature of about 50 °C and was assembled in the laboratory. All the experimental data were fed to a microcomputer and stored on disk automatically from appropriate transducers via amplifier and 16 channel analogue to digital converters. The measurements taken were R12 pressures and temperatures, water and R12 mass flow rates, air speed, fan and compressor input powers, water and air inlet and outlet temperatures, wet and dry bulb temperatures. The time interval between the observations could be varied. The results showed, as expected, that the COP was higher at higher air inlet temperatures and at lower hot water output temperatures. The optimum air speed was found to be at a speed when the fan input power was about 4% of the condenser heat output. It was also found that the hot water can be produced at a temperature higher than the appropriate R12 condensing temperature corresponding to condensing pressure. This was achieved by condenser design to take advantage of discharge superheat and by further heating the water using heat recovery from the compressor. Of the input power to the compressor, typically about 85% was transferred to the refrigerant, 50 % by the compression work and 35% due to the heating of the refrigerant by the cylinder wall, and the remaining 15% (of the input power) was rejected to the cooling medium. The evaporator effectiveness was found to be about 75% and sensitive to the air speed. Using the data collected, a steady state computer model was developed. For given input conditions s air inlet temperature, air speed, the degree of suction superheat , water inlet and outlet temperatures; the model is capable of predicting the refrigerant cycle, compressor efficiency, evaporator effectiveness, condenser water flow rate and system Cop.
Resumo:
SD Apo Lactoferrin-Tobramycin/Gentamicin Combinations are superior to monotherapy in the eradication of Pseudomonas aeruginosa Biofilm in the lungs Wilson Oguejiofor1, Lindsay J. Marshall1, Andrew J. Ingham1, Robert Price2, Jag. Shur2 1School of Life and Health Sciences, Aston University, Birmingham, UK. 2School of Pharmacy and Pharmacology, University of Bath, Bath, UK. KEYWORDS: lactoferrin, apo lactoferrin, spray drying, biofilm, cystic fibrosis Introduction Chronic lung infections from the opportunistic pathogeen Pseudomonas aeruginosa has been recognised as a major contributor to the incidences of high morbidity and mortality amongst cystic fibrosis (CF) patients (1,2). Currently, strategies for managing lung infections in CF patients involves the aggressive use of aerosolised antibiotics (3), however, increasing evidence suggests that the biofilm component of P. aeruginosa in the lower airway remains unperturbed and is associated with the development of antibiotic resistance. If this is so then, there is an urgent need to suitably adjust the current treatment strategy so that it includes compounds that prevent biofilm formation or disrupt established biofilms. It is well understood that biofilm formation is strongly dependent on iron (Fe3+) availability (4), therefore aerosolised anti-infective formulations which has the ability to chelate iron may essentially be a well suited therapy for eliminating P. aeruginosa biofilms on CF airway epithelial cells (5). In this study, we report the use of combination therapy; an aminoglycosides (tobramycin and gentamicin) and an antimicrobial peptide (lactoferrin) to significantly deplete P. aeruginosa biofilms. We demonstrate that lactoferrin-tobramycin and lactoferrin-gentamicin combinations are superior to the single antibiotic regime currently being employed to combat P. aeruginosa biofilms. MATERIALS AND METHOD Antibiotics: The antibiotics used in this study included gentamicin and tobramycin supplied by Fagron, UK. Bacterial strain and growth conditions: Pseudomonas aeruginosa strain PAO1 was provided by Prof. Peter Lambert of Aston University, Birmingham UK. The Strains were routinely grown from storage in a medium supplemented with magnesium chloride, glucose and casamino acids. Dialysis of lactoferrin: Apo lactoferrin was prepared by dialyzing a suspension of lactoferrin for 24 hrs at 4 °C against 20 mmol/L sodium dihydrogen phosphate, 20 mmol/L sodium acetate and 40 mmol/L EDTA (pH 3.5). Ferric ion (Fe3+) removal was verified by atomic absorption spectroscopy measurements. Spray drying of combinations of lactoferrin and apo lactoferrin with the different aminoglycosides: Combinations of tobramycin and gentamicin with the different preparations of lactoferrin were spray dried (SD) as a 2% (w/v) aqueous suspension. The spray drying parameters utilized for the production of suitable micron-sized particles includes: Inlet temperature, 180°C, spray flow rate, 606 L/hr; pump setting, 10%; aspirator setting, 85% (34m3/hr) to produce various outlet temperatures ranging from 99 - 106°C. Viability assay: To test the bactericidal activity of the various combinations, a viability assay was performed as previously described by Xu, Xiong et al. (6) with some modifications. Briefly, 10µL of ~ c. 6.6 x 107 CFU mL-1 P. aeruginosa strain PAO1 suspension were incubated (37°C, 60 mins) with 90 µL of a 2 µg/mL concentration of the various combinations and sampled every 10 mins. After incubation, the cells were diluted in deionised water and plated in Mueller hinton agar plates. Following 24 h incubation of the plates at 37°C, the percentage of viable cells was determined relative to incubation without added antibiotics. Biofilm assay: To test the susceptibility of the P. aeruginosa strain to various antibiotics in the biofilms mode of growth, overnight cultures of P. aeruginosa were diluted 1:100 into fresh medium supplemented with magnesium chloride, glucose and casamino acids. Aliquots of the dilution were dispensed into a 96 well dish and incubated (37°C, 24 h). Excess broth was removed and the number of colony forming units per milliliter (CFU/mL) of the planktonic bacteria was quantified. The biofilms were then washed and stained with 0.1% (w/v) crystal violet for 15 mins at room temperature. Following vigorous washing with water, the stained biofilms were solubilized in 30% acetic acid and the absorbance at 550nm of a 125 µL aliquot was determined in a microplate reader (Multiskan spectrum, Thermo Scientific) using 30% acetic acid in water as the blank. Aliquots of the broth prior to staining were used as an indicator of the level of planktonic growth. RESULTS AND DISCUSSION Following spray drying, the mean yield, volume weighted mean diameter and moisture content of lactoferrin powder were measured and were as follows (Table 1 and table 2); Table 1: Spray drying parameters FormulationInlet temp (°C)Outlet temp (°C)Airflow rate (L/hr)Mean yield (%)Moisture content (%) SD Lactoferrin18099 - 10060645.2 ±2.75.9 ±0.4 SD Apo Lactoferrin180100 - 10260657.8 ±1.85.7 ±0.2 Tobramycin180102 - 10460682.1 ±2.23.2 ±0.4 Lactoferrin + Tobramycin180104 - 10660687.5 ±1.43.7 ±0.2 Apo Lactoferrin + Tobramycin180103 - 10460676.3 ±2.43.3 ±0.5 Gentamicin18099 - 10260685.4 ±1.34.0 ±0.2 Lactoferrin + Gentamicin180102 - 10460687.3 ±2.13.9 ±0.3 Apo Lactoferrin + Gentamicin18099 -10360680.1±1.93.4 ±0.4 Table 2: Particle size distribution d10 d50d90 SD Lactoferrin1.384.9111.08 SD Apo Lactoferrin1.284.7911.04 SD Tobramycin1.254.9011.29 SD Lactoferrin + Tobramycin1.175.2715.23 SD Apo Lactoferrin + Tobramycin1.115.0614.31 SD Gentamicin1.406.0614.38 SD Lactoferrin + Gentamicin1.476.2314.41 SD Apo Lactoferrin + Gentamicin1.465.1511.53 The bactericidal activity of the various combinations were tested against P. aeruginosa PAO1 following a 60 minute incubation period (Figure 1 and Figure 2). While 2 µg/mL of a 1:1 combination of spray dried apo lactoferrin and Gentamicin was able to completely kill all bacterial cells within 40 mins, the same concentration was not as effective for the other antibiotic combinations. However, there was an overall reduction of bacterial cells by over 3 log units by the other combinations within 60 mins. Figure 1: Logarithmic plot of bacterial cell viability of various combinations of tobramycin and lactoferrin preparations at 2µg/mL (n = 3). Figure 2: Logarithmic plot of bacterial cell viability of various combinations of gentamicin and lactoferrin preparations at 2µg/mL (n = 3). Crystal violet staining showed that biofilm formation by P. aeruginosa PAO1 was significantly (ANOVA, p < 0.05) inhibited in the presence of the different lactoferrin preparations. Interestingly, apo lactoferrin and spray dried lactoferrin exhibited greater inhibition of both biofilm formation and biofilm persistence (Figure 2). Figure 2: Crystal violet staining of residual biofilms of P. aeruginosa following a 24hr incubation with the various combinations of antibiotics and an exposure to 48 hr formed biofilms. CONCLUSION In conclusion, combination therapy comprising of an antimicrobial peptide (lactoferrin) and an aminoglycosides (tobramycin or gentamicin) provides a feasible and alternative approach to monotherapy since the various combinations are more efficient than the respective monotherapy in the eradication of both planktonic and biofilms of P. aeruginosa. ACKNOWLEDGEMENT The authors would like to thank Mr. John Swarbrick and Friesland Campina for their generous donation of the Lactoferrin. REFERENCES 1.Hassett, D.J., Sutton, M.D., Schurr, M.J., Herr, A.B., Caldwell, C.C. and Matu, J.O. (2009), "Pseudomonas aeruginosa hypoxic or anaerobic biofilm infections within cystic fibrosis airways". Trends in Microbiology, 17, 130-138. 2.Trust, C.F. (2009), "Antibiotic treatment for cystic fibrosis". Report of the UK Cystic Fibrosis Trust Antibiotic Working Group. Consensus document. London: Cystic Fibrosis Trust. 3.Garcia-Contreras, L. and Hickey, A.J. (2002), "Pharmaceutical and biotechnological aerosols for cystic fibrosis therapy". Advanced Drug Delivery Reviews, 54, 1491-1504. 4.O'May, C.Y., Sanderson, K., Roddam, L.F., Kirov, S.M. and Reid, D.W. (2009), "Iron-binding compounds impair Pseudomonas aeruginosa biofilm formation, especially under anaerobic conditions". J Med Microbiol, 58, 765-773. 5.Reid, D.W., Carroll, V., O'May, C., Champion, A. and Kirov, S.M. (2007), "Increased airway iron as a potential factor in the persistence of Pseudomonas aeruginosa infection in cystic fibrosis". European Respiratory Journal, 30, 286-292. 6.Xu, G., Xiong, W., Hu, Q., Zuo, P., Shao, B., Lan, F., Lu, X., Xu, Y. and Xiong, S. (2010), "Lactoferrin-derived peptides and Lactoferricin chimera inhibit virulence factor production and biofilm formation in Pseudomonas aeruginosa". J Appl Microbiol, 109, 1311-1318.
Resumo:
The importance of mannitol has increased recently as an emerging diluent for orodispersible dosage forms. The study aims to prepare spray dried mannitol retaining high porosity and mechanical strength for the development of orally disintegrating tablets (ODTs). Aqueous feed of d-mannitol (10% w/v) comprising ammonium bicarbonate, NH4HCO3 (5% w/v) as pore former was spray dried at inlet temperature of 110-170°C. Compacts were prepared at 151MPa and characterized for porosity, hardness and disintegration time. Particle morphology and drying mechanisms were studied using thermal (HSM, DSC and TGA) and polymorphic (XRD) methods. Tablet porosity increased from 0.20±0.002 for pure mannitol to 0.53±0.03 using fabricated porous mannitol. Disintegration time dropped by 50-77% from 135±5.29s for pure mannitol to 75.33±2.52-31.67±1.53s for mannitol 110-170°C. Hardness increased by 150% at 110°C (258.67±28.89N) and 30% at 150°C (152.70±10.58N) compared to pure mannitol tablets (104.17±1.70N). Increasing inlet temperature resulted in reducing tablet hardness due to generation of 'micro-sponge'-like particles exhibiting significant elastic recovery. Impact of mannitol polymorphism on plasticity/elasticity cannot be ruled out as a mixture of α and β polymorphs formed upon spray drying.
Resumo:
In oil and gas pipeline operations, the gas, oil, and water phases simultaneously move through pipe systems. The mixture cools as it flows through subsea pipelines, and forms a hydrate formation region, where the hydrate crystals start to grow and may eventually block the pipeline. The potential of pipe blockage due to hydrate formation is one of the most significant flow-assurance problems in deep-water subsea operations. Due to the catastrophic safety and economic implications of hydrate blockage, it is important to accurately predict the simultaneous flow of gas, water, and hydrate particles in flowlines. Currently, there are few or no studies that account for the simultaneous effects of hydrate growth and heat transfer on flow characteristics within pipelines. This thesis presents new and more accurate predictive models of multiphase flows in undersea pipelines to describe the simultaneous flow of gas, water, and hydrate particles through a pipeline. A growth rate model for the hydrate phase is presented and then used in the development of a new three-phase model. The conservation equations of mass, momentum, and energy are formulated to describe the physical phenomena of momentum and heat transfer between the fluid and the wall. The governing equations are solved based on an analytical-numerical approach using a Newton-Raphson method for the nonlinear equations. An algorithm was developed in Matlab software to solve the equations from the inlet to the outlet of the pipeline. The developed models are validated against a single-phase model with mixture properties, and the results of comparative studies show close agreement. The new model predicts the volume fraction and velocity of each phase, as well as the mixture pressure and temperature profiles along the length of the pipeline. The results from the hydrate growth model reveal the growth rate and location where the initial hydrates start to form. Finally, to assess the impact of certain parameters on the flow characteristics, parametric studies have been conducted. The results show the effect of a variation in the pipe diameter, mass flow rate, inlet pressure, and inlet temperature on the flow characteristics and hydrate growth rates.
Resumo:
This work presents an experimental investigation of thermal hydraulic performance of the nanofluid composed by graphene nanoparticles dispersed in a mixture of water and ethylene glycol at a ratio of 70:30% by volume. The tests were carried out under forced convection inside a circular tube with uniform heat flux on the wall for the laminar-turbulent transition regime. The mass flow rate ranged from 40 to 70 g/s corresponding to Reynolds numbers between 3000 and 7500. The heat flux was maintained constant at values of 11, 16 and 21 kW/m², as well as the inlet temperature of 15, 20 and 25°C. Three samples were produced with the nanofluid volumetric concentration of 0.05%, 0.10% and 0.15%. Thermophysical properties were experimentaly measured for all samples that were critically compared and discussed with theoretical models most commonly used in the literature. Initially, experiments with distilled water confirmed the validity of the experimental equipment for the thermo-hydraulic tests. Therefore, nanofluid samples that showed the highest thermal conductivity, corresponding to the volumetric concentrations of 0.15% and 0.10%, were subjected to the tests. The thermal-hydraulic performance for both samples was unsatisfactory. The heat transfer coefficients for convection of nanofluids reduced 21% in average, for the sample with = 0.15% and 26% and for =0.10%. The pressure drop of the samples was higher than the base fluid. Finally, the pressure drop and heat transfer coefficient by convection of both samples were also compared to theoretical models. The models used for pressure drop showed an excellent agreement with experimental results, which is remarkable considering the transitional flow.