921 resultados para suspended robot-arm system (SRAS)
Resumo:
We demonstrate autonomous construction of structures using a robot arm that can fabricate threads of TPA (Thermoplastic Adhesive) in free space on the fly. TPA has many important material properties that help to greatly simplify the otherwise complex task of building structures in complex environments. We present a model for the formation of TPA strings based on plastic deformation which also includes the temperature dependent material properties which change significantly as the thread is formed and cools. Experiments of drawing TPA show that drawing forces due to the viscosity of the TPA are more dominated by the speed of drawing than the changes in viscosity due to temperature. The load bearing capacity of individual strings is also modelled and measured and structures are built using the TPA strings which due to the adhesiveness can be anchored to a wide range surfaces as well as to other strings. © 2013 IEEE.
Resumo:
Guided self-organization can be regarded as a paradigm proposed to understand how to guide a self-organizing system towards desirable behaviors, while maintaining its non-deterministic dynamics with emergent features. It is, however, not a trivial problem to guide the self-organizing behavior of physically embodied systems like robots, as the behavioral dynamics are results of interactions among their controller, mechanical dynamics of the body, and the environment. This paper presents a guided self-organization approach for dynamic robots based on a coupling between the system mechanical dynamics with an internal control structure known as the attractor selection mechanism. The mechanism enables the robot to gracefully shift between random and deterministic behaviors, represented by a number of attractors, depending on internally generated stochastic perturbation and sensory input. The robot used in this paper is a simulated curved beam hopping robot: a system with a variety of mechanical dynamics which depends on its actuation frequencies. Despite the simplicity of the approach, it will be shown how the approach regulates the probability of the robot to reach a goal through the interplay among the sensory input, the level of inherent stochastic perturbation, i.e., noise, and the mechanical dynamics. © 2014 by the authors; licensee MDPI, Basel, Switzerland.
Resumo:
结合星球探测的应用背景,对漫游车的工作方式进行了研究,针对车载机械臂开发了一套基于立体视觉的机械臂平面定位仿真系统。该系统依靠虚拟现实技术,通过虚拟机械臂对三维重建得到的平整物体表面的定位仿真得到机械臂的各关节参数,以此指导真实机械臂的运动。论述了基于立体视觉的机械臂定位机理和基于OpenGL的虚拟机械臂的实现过程。采用VC++构建了仿真实验平台,进行了定位实验,获得了较高的定位精度。
Resumo:
提出一种面向操作手装配系统的快速碰撞检测算法。该算法以机器人运动学和空间解析几何为基础 ,将判断机械手手臂与障碍物是否发生碰撞问题转化为直线段与有界平面是否存在公共点的简单解析几何问题 ,并以 PU MA5 6 0操作手为例对算法加以说明。该算法不仅适用于静态的障碍物已知的环境 ,而且适用于障碍物运动规律已知的动态环境 ,减少了碰撞检测占用的时间 ,提高了路径规划的效率
Resumo:
The goal of this thesis is to apply the computational approach to motor learning, i.e., describe the constraints that enable performance improvement with experience and also the constraints that must be satisfied by a motor learning system, describe what is being computed in order to achieve learning, and why it is being computed. The particular tasks used to assess motor learning are loaded and unloaded free arm movement, and the thesis includes work on rigid body load estimation, arm model estimation, optimal filtering for model parameter estimation, and trajectory learning from practice. Learning algorithms have been developed and implemented in the context of robot arm control. The thesis demonstrates some of the roles of knowledge in learning. Powerful generalizations can be made on the basis of knowledge of system structure, as is demonstrated in the load and arm model estimation algorithms. Improving the performance of parameter estimation algorithms used in learning involves knowledge of the measurement noise characteristics, as is shown in the derivation of optimal filters. Using trajectory errors to correct commands requires knowledge of how command errors are transformed into performance errors, i.e., an accurate model of the dynamics of the controlled system, as is demonstrated in the trajectory learning work. The performance demonstrated by the algorithms developed in this thesis should be compared with algorithms that use less knowledge, such as table based schemes to learn arm dynamics, previous single trajectory learning algorithms, and much of traditional adaptive control.
Resumo:
Q. Meng and M. H Lee, Automated cross-modal mapping in robotic eye/hand systems using plastic radial basis function networks, Connection Science, 19(1), pp 25-52, 2007.
Resumo:
Q. Meng and M.H. Lee, 'Biologically inspired automatic construction of cross-modal mapping in robotic eye/hand systems', IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2006,) ,4742-49, Beijing, 2006.
Resumo:
This article introduces an unsupervised neural architecture for the control of a mobile robot. The system allows incremental learning of the plant during robot operation, with robust performance despite unexpected changes of robot parameters such as wheel radius and inter-wheel distance. The model combines Vector associative Map (VAM) learning and associate learning, enabling the robot to reach targets at arbitrary distances without knowledge of the robot kinematics and without trajectory recording, but relating wheel velocities with robot movements.
Resumo:
X-ray mammography has been the gold standard for breast imaging for decades, despite the significant limitations posed by the two dimensional (2D) image acquisitions. Difficulty in diagnosing lesions close to the chest wall and axilla, high amount of structural overlap and patient discomfort due to compression are only some of these limitations. To overcome these drawbacks, three dimensional (3D) breast imaging modalities have been developed including dual modality single photon emission computed tomography (SPECT) and computed tomography (CT) systems. This thesis focuses on the development and integration of the next generation of such a device for dedicated breast imaging. The goals of this dissertation work are to: [1] understand and characterize any effects of fully 3-D trajectories on reconstructed image scatter correction, absorbed dose and Hounsifeld Unit accuracy, and [2] design, develop and implement the fully flexible, third generation hybrid SPECT-CT system capable of traversing complex 3D orbits about a pendant breast volume, without interference from the other. Such a system would overcome artifacts resulting from incompletely sampled divergent cone beam imaging schemes and allow imaging closer to the chest wall, which other systems currently under research and development elsewhere cannot achieve.
The dependence of x-ray scatter radiation on object shape, size, material composition and the CT acquisition trajectory, was investigated with a well-established beam stop array (BSA) scatter correction method. While the 2D scatter to primary ratio (SPR) was the main metric used to characterize total system scatter, a new metric called ‘normalized scatter contribution’ was developed to compare the results of scatter correction on 3D reconstructed volumes. Scatter estimation studies were undertaken with a sinusoidal saddle (±15° polar tilt) orbit and a traditional circular (AZOR) orbit. Clinical studies to acquire data for scatter correction were used to evaluate the 2D SPR on a small set of patients scanned with the AZOR orbit. Clinical SPR results showed clear dependence of scatter on breast composition and glandular tissue distribution, otherwise consistent with the overall phantom-based size and density measurements. Additionally, SPR dependence was also observed on the acquisition trajectory where 2D scatter increased with an increase in the polar tilt angle of the system.
The dose delivered by any imaging system is of primary importance from the patient’s point of view, and therefore trajectory related differences in the dose distribution in a target volume were evaluated. Monte Carlo simulations as well as physical measurements using radiochromic film were undertaken using saddle and AZOR orbits. Results illustrated that both orbits deliver comparable dose to the target volume, and only slightly differ in distribution within the volume. Simulations and measurements showed similar results, and all measured dose values were within the standard screening mammography-specific, 6 mGy dose limit, which is used as a benchmark for dose comparisons.
Hounsfield Units (HU) are used clinically in differentiating tissue types in a reconstructed CT image, and therefore the HU accuracy of a system is very important, especially when using non-traditional trajectories. Uniform phantoms filled with various uniform density fluids were used to investigate differences in HU accuracy between saddle and AZOR orbits. Results illustrate the considerably better performance of the saddle orbit, especially close to the chest and nipple region of what would clinically be a pedant breast volume. The AZOR orbit causes shading artifacts near the nipple, due to insufficient sampling, rendering a major portion of the scanned phantom unusable, whereas the saddle orbit performs exceptionally well and provides a tighter distribution of HU values in reconstructed volumes.
Finally, the third generation, fully-suspended SPECT-CT system was designed in and developed in our lab. A novel mechanical method using a linear motor was developed for tilting the CT system. A new x-ray source and a custom made 40 x 30 cm2 detector were integrated on to this system. The SPECT system was nested, in the center of the gantry, orthogonal to the CT source-detector pair. The SPECT system tilts on a goniometer, and the newly developed CT tilting mechanism allows ±15° maximum polar tilting of the CT system. The entire gantry is mounted on a rotation stage, allowing complex arbitrary trajectories for each system, without interference from the other, while having a common field of view. This hybrid system shows potential to be used clinically as a diagnostic tool for dedicated breast imaging.
Resumo:
The authors tested for predominant patterns of coordination in the combination of rhythmic flexion-extension (FE) and supination-pronation (SP) at the elbow-joint complex. Participants (N = 10) spontaneously established in-phase (supination synchronized with flexion) and antiphase (pronation synchronized with flexion) patterns. In addition, the authors used a motorized robot arm to generate involuntary SP movements with different phase relations with respect to voluntary FE. The involuntarily induced in-phase pattern was accentuated and was more consistent than other patterns. That result provides evidence that the predominance of the in-phase pattern originates in the influence of neuro-muscular-skeletal constraints rather than in a preference dictated by perceptual-cognitive factors implicated in voluntary control. Neuromuscular-skeletal constraints involved in the predominance of the in-phase and the antiphase patterns are discussed.
Resumo:
BACKGROUND: Robot surgery is a further step towards new potential developments in minimally invasive surgery. Surgeons must keep abreast of these new technologies and learn their limits and possibilities. Robot-assisted laparoscopic cholecystectomy has not yet been performed in our institution. The purpose of this report is to present the pathway of implementation of robotic laparoscopic cholecystectomy in a university hospital. METHODS: The Zeus(R) robot system was used. Experimental training was performed on animals. The results of our experimental training allowed us to perform our first two clinical cases. RESULTS: Robot arm set-up and trocar placement required 53 and 35 minutes. Operative time were 59 and 45 minutes respectively. The overall operative time was 112 and 80 minutes, respectively. There were no intraoperative complications. Patients were discharged from the hospital after an overnight stay. CONCLUSION: Robotic laparoscopic cholecystectomy is safe and patient recovery similar to those of standard laparoscopy. At present, there are no advantages of robotic over conventional surgery. Nevertheless, robots have the potential to revolutionise the way surgery is performed. Robot surgery is not reserved for a happy few. This technology deserves more attention because it has the potential to change the way surgery is performed.
Resumo:
In order to ease control, the links between actuators and robotic limbs are generally made to be as stiff as possible. This is in contrast to natural limbs, where compliance is present. Springs have been added to the drive train between the actuator and load to imitate this natural compliance. The majority of these springs have been in series between the actuator and load. However, a more biologically inspired approach is taken, here springs have been used in parallel to oppose each other. The paper will describe the application of parallel extension springs in a robot arm in order to give it compliance. Advantages and disadvantages of this application are discussed along with various control strategies.
Resumo:
It is common to make the links between actuators and robotic limbs as stiff as possible, in complete contrast to natural systems, where compliance is present. In the past, to create some compliance in a drive, springs have been added to the link between the actuator and load. Many of these springs have been in series with the drive, but recently a more 'biological' approach has been taken where two springs have been used in parallel to counteract each other. This paper describes the application of parallel extension springs in a robot arm in order to give it compliance. Advantages and disadvantages of this application are discussed, along with various control strategies.
Resumo:
Recently a substantial amount of research has been done in the field of dextrous manipulation and hand manoeuvres. The main concern has been how to control robot hands so that they can execute manipulation tasks with the same dexterity and intuition as human hands. This paper surveys multi-fingered robot hand research and development topics which include robot hand design, object force distribution and control, grip transform, grasp stability and its synthesis, grasp stiffness and compliance motion and robot arm-hand coordination. Three main topics are presented in this article. The first is an introduction to the subject. The second concentrates on examples of mechanical manipulators used in research and the methods employed to control them. The third presents work which has been done on the field of object manipulation.
Resumo:
This paper presents a review of the design and development of the Yorick series of active stereo camera platforms and their integration into real-time closed loop active vision systems, whose applications span surveillance, navigation of autonomously guided vehicles (AGVs), and inspection tasks for teleoperation, including immersive visual telepresence. The mechatronic approach adopted for the design of the first system, including head/eye platform, local controller, vision engine, gaze controller and system integration, proved to be very successful. The design team comprised researchers with experience in parallel computing, robot control, mechanical design and machine vision. The success of the project has generated sufficient interest to sanction a number of revisions of the original head design, including the design of a lightweight compact head for use on a robot arm, and the further development of a robot head to look specifically at increasing visual resolution for visual telepresence. The controller and vision processing engines have also been upgraded, to include the control of robot heads on mobile platforms and control of vergence through tracking of an operator's eye movement. This paper details the hardware development of the different active vision/telepresence systems.