975 resultados para screw pump


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Intraoperative EMG based neurophysiological monitoring is increasingly used to assist pedicle screw insertion. We carried out a study comparing the final screw position in the pedicle measured on CT images in relation to its corresponding intraoperative muscle compound action potential (CMAP) values. Material and methods: A total of 189 screws were inserted in thoracolumbar spines of 31 patients during instrumented fusion under EMG control. An observer, blinded to the CMAP value, assessed the horizontal and vertical 'screw edge to pedicle edge' distance perpendicular to the longitudinal axis of the screw on reformatted CT reconstructions using OsiriX software. These distances were analysed with their corresponding CMAP values. Data from 62 thoracic and 127 lumbar screws were processed separately. Interobserver reliability of distance measurements was assessed. Results: No patient suffered neurological injury secondary to screw insertion. Distance measurements were reliable (paired t-test, P = 0.13/0.98 horizontal/vertical). Two screws had their position altered due to low CMAP values suggesting close proximity of nerve tissue. Seventy five percent of screws had CMAP results above 10mA and had an average distance of 0.35cm (SD 0.23) horizontally and 0.46cm (SD 0.26) vertically from the pedicle edge. Additional 12% had a distance from the edge of the pedicle less than 0mm indicating cortical breach but had CMAP values above 10mA. A poor correlation between CMAP values and screw position was found. Discussion: In this study CMAP values above 10mA indicated correct screw position in the majority of cases. The zone of 10-20mA CMAP carries highest risk of a misplaced screw despite high CMAP value (17% of screws this CMAP range). In order to improve accuracy of EMG predictive value further research is warranted including improvement of probing techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neurons fire by releasing neurotransmitters via fusion of synaptic vesicles with the plasma membrane. Fusion can be evoked by an incoming signal from a preceding neuron or can occur spontaneously. Synaptic vesicle fusion requires the formation of trans complexes between SNAREs as well as Ca(2+) ions. Wang et al. (2014. J. Cell Biol. http://dx.doi.org/jcb.201312109) now find that the Ca(2+)-binding protein Calmodulin promotes spontaneous release and SNARE complex formation via its interaction with the V0 sector of the V-ATPase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Calcium uptake by tonoplast enriched membrane vesicles from maize (Zea mays L. cv. LG 11) primary roots was studied. A pH gradient, measured by the fluorescence quenching of quinacrine, was generated across sealed vesicles driven by the pyrophosphate-dependent proton pump. The fluorescence quenching was strongly inhibited by Ca2+; moreover, when increasing Ca2+ concentrations were added to vesicles at steady-state, a concomitant decrease in the proton gradient was observed. Ca2+ uptake using Ca-45(2+) was linear from 10 min when oxalate (10 mM) was present, while Ca2+ uptake was completely inhibited with proton ionophores (FCCP and monensin), indicating a Ca2+/H+ antiport. Membranes were further fractionated using a linear sucrose density gradient (10-45%) and were identified with marker enzymes. Ca2+ uptake co-migrated with the tonoplast pyrophosphate-dependent proton pumping, pyrophosphatase and ATPase activities: the Ca2+/H+ antiport is consequently located at the tonoplast.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The subcellular localization of a calmodulin-stimulated calcium (Ca2+)-ATPase activity from maize roots (Zea mays L., cv LG 11) was studied. For this purpose, an efficient procedure was developed to prepare sealed plasma membrane vesicles allowing the measurement of proton and Ca2+ transport activities. Two-day-old root membranes were fractionated by sucrose and dextran density gradient centrifugation. Marker enzymes were used to study the distribution of the different membranes in the gradients and a filtration technique was developed to measure Ca-45(2+) transport in sealed vesicles. Most of the ATP-dependent Ca2+ transport activity was associated with the ER. However, a small part of this activity was associated with the tonoplast (corresponding to the activity of the H+/Ca2+ antiport) and the plasma membrane. When the Ca2+ transport was measured in the presence of exogenous calmodulin (1 muM), a 3-5-fold increase of uptake was measured. The calmodulin-stimulated activity was associated with the tonoplast vesicles only. This activity was insensitive to monensin, a proton ionophore, ruling out a direct effect of calmodulin on the H+/Ca2+ antiport. In conclusion, four different Ca2+ transporters are present in young maize root cells. A Ca2+/H+ antiport system is present on the tonoplast, whereas, the plasma membrane and the ER possess each a calmodulinin-sensitive Ca2+-ATPase. Finally, a calmodulin-stimulated Ca2+-ATPase is associated with the tonoplast.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hydrolytic subunit of the H+-translocating inorganic pyrophosphatase (V-PPase EC 3.6.1.1.) prepared from Rubus hispidus cell cultures has been purified from tonoplast-enriched membranes and analysed by SDS-polyacrylamide gel electrophoresis, Only one polypeptide of M(r) 70 000 was recovered with the V-PPase activity after solubilization in the presence of Triton X-100, purification by gel filtration (Superose) and anion exchange (Mono Q) chromatography. This polypeptide strongly cross-reacted with an antibody raised against the V-PPase from Vigna radiata. The tonoplast-enriched fraction was also used to solubilize and reconstitute the-V-PPase. The proteoliposomes showing a PPi-dependent proton transport activity were purified by gel filtration (Superose) and analysed by SDS-polyacrylamide gel electrophoresis. Only one polypeptide of M(r) 70 000 was recovered with the proton-pumping activity. All these data suggest that the native V-PPase from Rubus is composed of a single kind of polypeptide with an M(r) of 70 000 and representing the catalytic subunit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Cardiopulmonary bypass (CPB) with aortic cross-clamping and cardioplegic arrest remains the method of choice for patients requiring standard myocardial revascularization. Therefore, very high-risk patients presenting with acute coronary syndrome, unstable angina, onset of cardiac decompensation and requiring emergency multiple myocardial revascularization, can have a poor outcome. The on-pump beating heart technique can reduce the mortality and the morbidity in such a selected group of patients and this report describes our clinical experience. METHODS: Out of 290 patients operated for CABG from January 2005 to January 2006, 25 (8.6%) selected high-risk patients suffering from life threatening coronary syndrome (mean age 69 +/- 7 years) and requiring emergency multiple myocardial revascularization, underwent on-pump beating heart surgery. The mean pre-operative left ventricle ejection fraction (LVEF) was 27 +/- 8%. The majority of them (88%) suffered of tri-vessel coronary disease and 6 (24%) had a left main stump disease. Nine patients (35%) were on severe cardiac failure and seven among them (28%) received a pre-operative intra-aortic balloon pump. The pre-operative EuroScore rate was equal or above 8 in 18 patients (73%). RESULTS: All patients underwent on-pump-beating heart coronary revascularization. The mean number of graft/patient was 2.9 +/- 0.6 and the internal mammary artery was used in 23 patients (92%). The mean CPB time was 84 +/- 19 minutes. Two patients died during the recovery stay in the intensive care unit, and there were no postoperative myocardial infarctions between the survivors. Eight patients suffered of transitorily renal failure and 1 patient developed a sternal wound infection. The mean hospital stay was 12 +/- 7 days. The follow-up was complete for all 23 patients survived at surgery and the mean follow-up time was 14 +/- 5 months. One patient died during the follow-up for cardiac arrest and 2 patients required an implantable cardiac defibrillator. One year after surgery they all had a standard trans-thoracic echocardiogram showing a mean LVEF rate of 36 +/- 11.8%. CONCLUSION: Standard on-pump arrested heart coronary surgery has higher mortality and morbidity in emergencies. The on-pump beating heart myocardial revascularization seems to be a valid alternative for the restricted and selected cohort of patients suffering from life threatening coronary syndrome and requiring multiple emergency CABG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Off-pump coronary artery bypass grafting has stimulated the development of micro-pumps designed to prevent the hemodynamic instability induced by heart luxation for the exposure of target vessels of the posterior wall. Impella (Aachen, Germany) developed micro-pumps with a miniaturized propeller system for both sides of the heart. The aim of this study was to analyze the impact of both pumps working together on blood cell integrity. MATERIALS AND METHODS: Both right and left-sided micro-pumps were implanted in 5 calves (body weight, 72_4 Kg) during 3 h. Blood samples for hematology and hemolysis parameters were drawn hourly. RESULTS: Both pumps performed well with a flow of 3.6 L +/- 0.3 L during the 3 h of the experiment with stable hemodynamic conditions. Mixed venous oxygen saturation was 63.4 +/- 15.2% at baseline and 63.8 +/- 16.3% at the end of the experiment (P = ns). Red cell count, LDH and free plasma hemoglobin were 6.7 +/- 2.1 x 10(12)/L, 1807 +/- 437 IU/L, and 32 +/- 9 mg/L at baseline vs. 6.1 +/- 2.1 x 10(12)/L, 1871 +/- 410 IU/L, and 52 +/- 9 mg/L at the end of the experiment (P = ns for all comparisons). Platelet count exhibited a non-significant drop (872 +/- 126 vs. 715 +/- 22 x 10(9)/L). CONCLUSIONS: This double pump system based on the Archimed screw principle is hematologically well tolerated under conditions of prolonged cardiac assist.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Off-pump trans left ventricular approach provides more precise deployment of stented aortic valve of any size with respect to the endovascular replacement. One of the key steps of this procedure is the ventricle repair after catheter withdrawing. We designed an animal study to compare the consistency of a sutureless repair of the left ventricle access using nitinol occluder with and without pericardial cuff on the ventricular side. METHODS: Material description: The Amplatz-nitinol occluder consists of two square heads squeezing ventricle wall in between them, sealing the defect. To improve its sealing property, a pericardial patch was sutured to the ventricular head of the occluder. Animal study setup: In adult pigs, a 30F sheath was inserted into the epigastric area through the cardiac apex, up to the left ventricle, simulating the approach for off-pump aortic valve replacement. The sheath was then removed and the ventricle closed with standard occluder in half of the animals, and cuffed occluder in the other half. Animals were followed-up for 3h, collecting haemodynamics data and pericardial bleeding. RESULTS: Device was successfully deployed in 12 animals in less than 1min. In the group where the standard occluder was used, bleeding during the deployment was 80+/-20ml and after the deployment was 800+/-20ml over 3h. In the group where the cuffed occluder was used, bleeding during the deployment was 85+/-20ml and after the deployment was 100+/-5ml over 3h. In the cuffed group, bleeding was significantly lower than the standard group, p-value being <0.001. CONCLUSIONS: The occluder is easy to use and the pericardial cuff dramatically increases its efficacy as demonstrated by a significant reduction of blood loss. The cuffed occluder opens the way for endoscopic, off-pump, transventricular aortic valve replacement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative research that aimed to identify the mean total cost (MTC) of connecting, maintaining and disconnecting patient-controlled analgesia pump (PCA) in the management of pain. The non-probabilistic sample corresponded to the observation of 81 procedures in 17 units of the Central Institute of the Clinics Hospital, Faculty of Medicine, University of Sao Paulo. We calculated the MTC multiplying by the time spent by nurses at a unit cost of direct labor, adding the cost of materials and medications/solutions. The MTC of connecting was R$ 107.91; maintenance R$ 110.55 and disconnecting R$ 4.94. The results found will subsidize discussions about the need to transfer money from the Unified Health System to hospitals units that perform this technique of analgesic therapy and it will contribute to the cost management aimed at making efficient and effective decision-making in the allocation of available resources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Object Recent years have been marked by efforts to improve the quality and safety of pedicle screw placement in spinal instrumentation. The aim of the present study is to compare the accuracy of the SpineAssist robot system with conventional fluoroscopy-guided pedicle screw placement. Methods Ninety-five patients suffering from degenerative disease and requiring elective lumbar instrumentation were included in the study. The robot cohort (Group I; 55 patients, 244 screws) consisted of an initial open robot-assisted subgroup (Subgroup IA; 17 patients, 83 screws) and a percutaneous cohort (Subgroup IB, 38 patients, 161 screws). In these groups, pedicle screws were placed under robotic guidance and lateral fluoroscopic control. In the fluoroscopy-guided cohort (Group II; 40 patients, 163 screws) screws were inserted using anatomical landmarks and lateral fluoroscopic guidance. The primary outcome measure was accuracy of screw placement on the Gertzbein-Robbins scale (Grade A to E and R [revised]). Secondary parameters were duration of surgery, blood loss, cumulative morphine, and length of stay. Results In the robot group (Group I), a perfect trajectory (A) was observed in 204 screws (83.6%). The remaining screws were graded B (n = 19 [7.8%]), C (n = 9 [3.7%]), D (n = 4 [1.6%]), E (n = 2 [0.8%]), and R (n = 6 [2.5%]). In the fluoroscopy-guided group (Group II), a completely intrapedicular course graded A was found in 79.8% (n = 130). The remaining screws were graded B (n = 12 [7.4%]), C (n = 10 [6.1%]), D (n = 6 [3.7%]), and E (n = 5 [3.1%]). The comparison of "clinically acceptable" (that is, A and B screws) was neither different between groups (I vs II [p = 0.19]) nor subgroups (Subgroup IA vs IB [p = 0.81]; Subgroup IA vs Group II [p = 0.53]; Subgroup IB vs Group II [p = 0.20]). Blood loss was lower in the robot-assisted group than in the fluoroscopy-guided group, while duration of surgery, length of stay, and cumulative morphine dose were not statistically different. Conclusions Robot-guided pedicle screw placement is a safe and useful tool for assisting spine surgeons in degenerative spine cases. Nonetheless, technical difficulties remain and fluoroscopy backup is advocated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The study aimed to evaluate the feasibility of off-pump transapical mitral valve-in-ring implantation and to test the performance of a custom-made self-expandable stent valve, in comparison with the standard SAPIEN valve. METHODS: Acute experiments were performed in five pigs. Animals (mean weight 58.4 ± 7.3 kg) underwent mitral valve annuloplasties under cardiopulmonary bypass using 26-mm rings (SJM?). Then, a 30-mm custom-made self-expandable stent valve or a 23-mm balloon-expandable transcatheter heart valve (Edwards SAPIEN XT?) was deployed within the annuloplasty rings through a transatrial access and under direct vision. Subsequently, the stent valves were inserted transapically under fluoroscopic guidance and off pump. RESULTS: The procedural success of transatrial and transapical mitral valve-in-ring procedures was 100% (10 of 10). Mean transatrial and transapical procedure time was 2.0 ± 1.1 and 22.0 ± 5.7 min, respectively. Haemodynamic status during transapical implantation remained stable, and differences in data collected before and after the stent-valve deployment were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area in the group of self-expandable stent valves were 2.60 ± 0.02 cm and 4.16 ± 0.48 cm(2), respectively, whereas in the SAPIEN group they were 1.95 ± 0.18 cm and 2.26 ± 0.20 cm(2), respectively. Trace or mild regurgitation was detected only in the self-expandable stent-valve group. Mean gradients were 4.1 ± 4.5 mmHg across the self-expandable stent valves and 1.0 ± 0 mmHg across the SAPIEN valves. Postmortem examination confirmed adequate positioning of the self-expandable valves and the SAPIEN valves within the annuloplasty ring. CONCLUSIONS: Off-pump transapical mitral valve-in-ring implantation is safe and feasible. Transapical access may represent the ideal option for valve-in-ring procedures in cases of recurrent mitral regurgitation after mitral valve repair, in high-risk patients. Owing to the supra-annular profile of the valve components, our custom-made nitinol stent valve provides nearer to normal functional area than the SAPIEN valve.