978 resultados para sample preparation automation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dielectrophoresis (DEP) has been used to manipulate cells in low-conductivity suspending media using AC electrical fields generated on micro-fabricated electrode arrays. This has created the possibility of performing automatically on a micro-scale more sophisticated cell processing than that currently requiring substantial laboratory equipment, reagent volumes, time, and human intervention. In this research the manipulation of aqueous droplets in an immiscible, low-permittivity suspending medium is described to complement previous work on dielectrophoretic cell manipulation. Such droplets can be used as carriers not only for air- and water-borne samples, contaminants, chemical reagents, viral and gene products, and cells, but also the reagents to process and characterize these samples. A long-term goal of this area of research is to perform chemical and biological assays on automated, micro-scaled devices at or near the point-of-care, which will increase the availability of modern medicine to people who do not have ready access to large medical institutions and decrease the cost and delays associated with that lack of access. In this research I present proofs-of-concept for droplet manipulation and droplet-based biochemical analysis using dielectrophoresis as the motive force. Proofs-of-concept developed for the first time in this research include: (1) showing droplet movement on a two-dimensional array of electrodes, (2) achieving controlled dielectric droplet injection, (3) fusing and reacting droplets, and (4) demonstrating a protein fluorescence assay using micro-droplets. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The leaf cuticular ultrastructure of some plant species has been examined by transmission electron microscopy (TEM) in only few studies. Attending to the different cuticle layers and inner structure, plant cuticles have been grouped into six general morphological types. With the aim of critically examining the effect of cuticle isolation and preparation for TEM analysis on cuticular ultrastructure, adaxial leaf cuticles of blue-gum eucalypt, grey poplar, and European pear were assessed, following a membrane science approach. The embedding and staining protocols affected the ultrastructure of the cuticles analysed. The solubility parameter, surface tension, and contact angles with water of pure Spurr's and LR-White resins were within a similar range. Differences were however estimated for resin : solvent mixtures, since Spurr’s resin is combined with acetone and LR-White resin is mixed with ethanol. Given the composite hydrophilic and lipophilic nature of plant cuticles, the particular TEM tissue embedding and staining procedures employed may affect sample ultrastructure and the interpretation of the results in physicochemical and biological terms. It is concluded that tissue preparation procedures may be optimised to facilitate the observation of the micro- and nanostructure of cuticular layers and components with different degrees of polarity and hydrophobicity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Powder metallurgy alloys are typically inhomogeneous with a significant amount of porosity. This complicates conventional transmission electron microscopy sample preparation. However, the use of focused ion beam milling allows site specific transmission electron microscopy samples to be prepared in a short amount of time. This paper presents a method that can be used to produce transmission electron microscopy samples from an Al-Cu-Mg PM alloy. (C) 2003 IoM Communications Ltd. Published by Maney for the Institute of Materials, Minerals and Mining.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study investigates the effect of different sample preparation methods on the pyrolysis behaviour of metal-added biomass; Willow samples were compared in the presence of two salts of zinc and lead containing sulphate and nitrate anions which were added to the wood samples with three different techniques as dry-mixing, impregnation and ion-exchange. The effect of acid and water wash as common demineralisation pre-treatments were also analysed to evaluate their roles in the thermal degradation of the biomass. Results from thermogravimetric analysis (TGA), Fourier transform infrared spectroscopy (FT-IR) and pyrolysis-mass spectrometry (Py-MS) measurements indicated that these pre-treatments change the matrix and the physical-chemical properties of wood. Results suggested that these structural changes increase the thermal stability of cellulose during pyrolysis. Sample preparation was also found to be a crucial factor during pyrolysis; different anions of metal salts changed the weight loss rate curves of wood material, which indicates changes in the primary degradation process of the biomass. Results also showed that dry-mixing, impregnation or ion-exchange influence the thermal behaviour of wood in different ways when a chosen metal salt was and added to the wood material. © 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Direct analysis, with minimal sample pretreatment, of antidepressant drugs, fluoxetine, imipramine, desipramine, amitriptyline, and nortriptyline in biofluids was developed with a total run time of 8 min. The setup consists of two HPLC pumps, injection valve, capillary RAM-ADS-C18 pre-column and a capillary analytical C 18 column connected by means of a six-port valve in backflush mode. Detection was performed with ESI-MS/MS and only 1 mu m of sample was injected. Validation was adequately carried out using FLU-d(5) as internal standard. Calibration curves were constructed under a linear range of 1-250 ng mL(-1) in plasma, being the limit of quantification (LOQ), determined as 1 ng mL(-1), for all the analytes. With the described approach it was possible to reach a quantified mass sensitivity of 0.3 pg for each analyte (equivalent to 1.1-1.3 fmol), translating to a lower sample consumption (in the order of 103 less sample than using conventional methods). (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As the pressure continues to grow on Diamond and the world's synchrotrons for higher throughput of diffraction experiments, new and novel techniques are required for presenting micron dimension crystals to the X ray beam. Currently this task is both labour intensive and primarily a serial process. Diffraction measurements typically take milliseconds but sample preparation and presentation can reduce throughput down to 4 measurements an hour. With beamline waiting times as long as two years it is of key importance for researchers to capitalize on available beam time, generating as much data as possible. Other approaches detailed in the literature [1] [2] [3] are very much skewed towards automating, with robotics, the actions of a human protocols. The work detailed here is the development and discussion of a bottom up approach relying on SSAW self assembly, including material selection, microfluidic integration and tuning of the acoustic cavity to order the protein crystals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As the pressure continues to grow on Diamond and the world's synchrotrons for higher throughput of diffraction experiments, new and novel techniques are required for presenting micron dimension crystals to the X ray beam. Currently this task is both labour intensive and primarily a serial process. Diffraction measurements typically take milliseconds but sample preparation and presentation can reduce throughput down to 4 measurements an hour. With beamline waiting times as long as two years it is of key importance for researchers to capitalize on available beam time, generating as much data as possible. Other approaches detailed in the literature [1] [2] [3] are very much skewed towards automating, with robotics, the actions of a human protocols. The work detailed here is the development and discussion of a bottom up approach relying on SSAW self assembly, including material selection, microfluidic integration and tuning of the acoustic cavity to order the protein crystals.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

It has been demonstrated that laser induced breakdown spectrometry (LIBS) can be used as an alternative method for the determination of macro (P, K. Ca, Mg) and micronutrients (B, Fe, Cu, Mn, Zn) in pellets of plant materials. However, information is required regarding the sample preparation for plant analysis by LIBS. In this work, methods involving cryogenic grinding and planetary ball milling were evaluated for leaves comminution before pellets preparation. The particle sizes were associated to chemical sample properties such as fiber and cellulose contents, as well as to pellets porosity and density. The pellets were ablated at 30 different sites by applying 25 laser pulses per site (Nd:YAG@1064 nm, 5 ns, 10 Hz, 25J cm(-2)). The plasma emission collected by lenses was directed through an optical fiber towards a high resolution echelle spectrometer equipped with an ICCD. Delay time and integration time gate were fixed at 2.0 and 4.5 mu s, respectively. Experiments carried out with pellets of sugarcane, orange tree and soy leaves showed a significant effect of the plant species for choosing the most appropriate grinding conditions. By using ball milling with agate materials, 20 min grinding for orange tree and soy, and 60 min for sugarcane leaves led to particle size distributions generally lower than 75 mu m. Cryogenic grinding yielded similar particle size distributions after 10 min for orange tree, 20 min for soy and 30 min for sugarcane leaves. There was up to 50% emission signal enhancement on LIBS measurements for most elements by improving particle size distribution and consequently the pellet porosity. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Sample preparation and DNA extraction protocols for DNA amplification by PCR, which can be applied in human fecal samples for taeniasis diagnosis, are described. DNA extracted from fecal specimens with phenol/chloroform/isoamilic alcohol and DNAzol® reagent had to be first purified to generate fragments of 170 pb and 600 pb by HDP2-PCR. This purification step was not necessary with the use of QIAmp DNA stool mini kit®. Best DNA extraction results were achieved after eggs disruption with glass beads, either with phenol/chloroform/isoamilic alcohol, DNAzol® reagent or QIAmp DNA stool mini kit®.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Drug screening is an important issue in clinical and forensic toxicology. Gas chromatography coupled to mass spectrometry (GC-MS) remains the gold standard technique for the screening of unknown compounds in urine samples. However, this technique requires substantial sample preparation, which is time consuming. Moreover, some common drugs such as cannabis cannot be easily detected in urine using general procedures. In this work, a sample preparation protocol for treating 200 μL of urine in less than 30 min is described. The enzymatic hydrolysis of glucuro-conjugates was performed in 5 min thanks to the use of microwaves. The use of a deconvolution software allowed reducing the GC-MS run to 10 min, without impairing the quality of the compound identifications. Comparing the results from 139 authentic urine samples to those obtained using the current routine analysis indicated this method performed well. Moreover, additional 5-min GC-MS/MS programs are described, enabling a very sensitive target screening of 54 drugs, including THC-COOH or buprenorphine, without further sample preparation. These methods appeared as an interesting alternative to immuno-assays based screening. The analytical strategy presented in this article proved to be a promising approach for systematic toxicological analysis (STA) of drugs in urine.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Dried blood spots (DBS) sampling has gained popularity in the bioanalytical community as an alternative to conventional plasma sampling, as it provides numerous benefits in terms of sample collection and logistics. The aim of this work was to show that these advantages can be coupled with a simple and cost-effective sample pretreatment, with subsequent rapid LC-MS/MS analysis for quantitation of 15 benzodiazepines, six metabolites and three Z-drugs. For this purpose, a simplified offline procedure was developed that consisted of letting a 5-µl DBS infuse directly into 100 µl of MeOH, in a conventional LC vial. RESULTS: The parameters related to the DBS pretreatment, such as extraction time or internal standard addition, were investigated and optimized, demonstrating that passive infusion in a regular LC vial was sufficient to quantitatively extract the analytes of interest. The method was validated according to international criteria in the therapeutic concentration ranges of the selected compounds. CONCLUSION: The presented strategy proved to be efficient for the rapid analysis of the selected drugs. Indeed, the offline sample preparation was reduced to a minimum, using a small amount of organic solvent and consumables, without affecting the accuracy of the method. Thus, this approach enables simple and rapid DBS analysis, even when using a non-DBS-dedicated autosampler, while lowering the costs and environmental impact.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We performed a number of tests with the aim to develop an effective extraction method for the analysis of carotenoid content in maize seed. Mixtures of methanol–ethyl acetate (6:4, v/v) and methanol–tetrahydrofuran (1:1, v/v) were the most effective solvent systems for carotenoid extraction from maize endosperm under the conditions assayed. In addition, we also addressed sample preparation prior to the analysis of carotenoids by liquid chromatography (LC). The LC response of extracted carotenoids and standards in several solvents was evaluated and results were related to the degree of solubility of these pigments. Three key factors were found to be important when selecting a suitable injection solvent: compatibility between the mobile phase and injection solvent, carotenoid polarity and content in the matrix.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The present work describes the development of a fast and robust analytical method for the determination of 53 antibiotic residues, covering various chemical groups and some of their metabolites, in environmental matrices that are considered important sources of antibiotic pollution, namely hospital and urban wastewaters, as well as in river waters. The method is based on automated off-line solid phase extraction (SPE) followed by ultra-high-performance liquid chromatography coupled to quadrupole linear ion trap tandem mass spectrometry (UHPLC–QqLIT). For unequivocal identification and confirmation, and in order to fulfill EU guidelines, two selected reaction monitoring (SRM) transitions per compound are monitored (the most intense one is used for quantification and the second one for confirmation). Quantification of target antibiotics is performed by the internal standard approach, using one isotopically labeled compound for each chemical group, in order to correct matrix effects. The main advantages of the method are automation and speed-up of sample preparation, by the reduction of extraction volumes for all matrices, the fast separation of a wide spectrum of antibiotics by using ultra-high-performance liquid chromatography, its sensitivity (limits of detection in the low ng/L range) and selectivity (due to the use of tandem mass spectrometry) The inclusion of β-lactam antibiotics (penicillins and cephalosporins), which are compounds difficult to analyze in multi-residue methods due to their instability in water matrices, and some antibiotics metabolites are other important benefits of the method developed. As part of the validation procedure, the method developed was applied to the analysis of antibiotics residues in hospital, urban influent and effluent wastewaters as well as in river water samples

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The central goal of food safety policy in the European Union (EU) is to protect consumer health by guaranteeing a high level of food safety throughout the food chain. This goal can in part be achieved by testing foodstuffs for the presence of various chemical and biological hazards. The aim of this study was to facilitate food safety testing by providing rapid and user-friendly methods for the detection of particular food-related hazards. Heterogeneous competitive time-resolved fluoroimmunoassays were developed for the detection of selected veterinary residues, that is coccidiostat residues, in eggs and chicken liver. After a simplified sample preparation procedure, the immunoassays were performed either in manual format with dissociation-enhanced measurement or in automated format with pre-dried assay reagents and surface measurement. Although the assays were primarily designed for screening purposes providing only qualitative results, they could also be used in a quantitative mode. All the developed assays had good performance characteristics enabling reliable screening of samples at concentration levels required by the authorities. A novel polymerase chain reaction (PCR)-based assay system was developed for the detection of Salmonella spp. in food. The sample preparation included a short non-selective pre-enrichment step, after which the target cells were collected with immunomagnetic beads and applied to PCR reaction vessels containing all the reagents required for the assay in dry form. The homogeneous PCR assay was performed with a novel instrument platform, GenomEra, and the qualitative assay results were automatically interpreted based on end-point time-resolved fluorescence measurements and cut-off values. The assay was validated using various food matrices spiked with sub-lethally injured Salmonella cells at levels of 1-10 colony forming units (CFU)/25 g of food. The main advantage of the system was the exceptionally short time to result; the entire process starting from the pre-enrichment and ending with the PCR result could be completed in eight hours. In conclusion, molecular methods using state-of-the-art assay techniques were developed for food safety testing. The combination of time-resolved fluorescence detection and ready-to-use reagents enabled sensitive assays easily amenable to automation. Consequently, together with the simplified sample preparation, these methods could prove to be applicable in routine testing.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study concerns certain problems inherent to the determination of fat-soluble vitamins in food, from extraction methods to identification and quantification. The discussion involves the main official and unofficial extraction methods coupled with spectrophotometric and HPLC techniques in which vitamins samples are obtained through liquid-liquid-solid and liquid-liquid-solid-solid extraction, indispensable to the analytical separation of different chemical compounds with vitamin functions. A saponification stage, possibly coupled with supercritical fluid extraction appears to be mandatory in the determination of vitamins A and E in their alcoholic forms. Alternative identification and quantification procedures are outlined: biological and chemical assays, analytical separations by HPLC (normal and reversed-phase), UV detection (all fat-soluble vitamins) and fluorescence detection (retinoids and tocopherols). Automation from sample preparation to quantification stages increases the data acquisition rate.