986 resultados para reference value


Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION Selenium is an essential micronutrient for human health, being a cofactor for enzymes with antioxidant activity that protect the organism from oxidative damage. An inadequate intake of this mineral has been associated with the onset and progression of chronic diseases such as hypertension, diabetes, coronary diseases, asthma, and cancer. For this reason, knowledge of the plasma and erythrocyte selenium levels of a population makes a relevant contribution to assessment of its nutritional status. OBJECTIVE The objective of the present study was to determine the nutritional status of selenium and risk of selenium deficiency in a healthy adult population in Spain by examining food and nutrient intake and analyzing biochemical parameters related to selenium metabolism, including plasma and erythrocyte levels and selenium-dependent glutathione peroxidase (GPx) enzymatic activity. MATERIAL AND METHODS We studied 84 healthy adults (31 males and 53 females) from the province of Granada, determining their plasma and erythrocyte selenium concentrations and the association of these levels with the enzymatic activity of glutathione peroxidase (GPx) and with life style factors. We also gathered data on their food and nutrient intake and the results of biochemical analyses. Correlations were studied among all of these variables. RESULTS The mean plasma selenium concentration was 76.6 ± 17.3 μg/L (87.3 ± 17.4 μg/L in males, 67.3 ± 10.7 μg/L in females), whereas the mean erythrocyte selenium concentration was 104.6 μg/L (107.9 ± 26.1 μg/L in males and 101.7 ± 21.7 μg/L in females). The nutritional status of selenium was defined by the plasma concentration required to reach maximum GPx activity, establishing 90 μg/L as reference value. According to this criterion, 50% of the men and 53% of the women were selenium deficient. CONCLUSIONS Selenium is subjected to multiple regulation mechanisms. Erythrocyte selenium is a good marker of longer term selenium status, while plasma selenium appears to be a marker of short-term nutritional status. The present findings indicate a positive correlation between plasma selenium concentration and the practice of physical activity. Bioavailability studies are required to establish appropriate reference levels of this mineral for the Spanish population.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The activity of radiopharmaceuticals in nuclear medicine is measured before patient injection with radionuclide calibrators. In Switzerland, the general requirements for quality controls are defined in a federal ordinance and a directive of the Federal Office of Metrology (METAS) which require each instrument to be verified. A set of three gamma sources (Co-57, Cs-137 and Co-60) is used to verify the response of radionuclide calibrators in the gamma energy range of their use. A beta source, a mixture of (90)Sr and (90)Y in secular equilibrium, is used as well. Manufacturers are responsible for the calibration factors. The main goal of the study was to monitor the validity of the calibration factors by using two sources: a (90)Sr/(90)Y source and a (18)F source. The three types of commercial radionuclide calibrators tested do not have a calibration factor for the mixture but only for (90)Y. Activity measurements of a (90)Sr/(90)Y source with the (90)Y calibration factor are performed in order to correct for the extra-contribution of (90)Sr. The value of the correction factor was found to be 1.113 whereas Monte Carlo simulations of the radionuclide calibrators estimate the correction factor to be 1.117. Measurements with (18)F sources in a specific geometry are also performed. Since this radionuclide is widely used in Swiss hospitals equipped with PET and PET-CT, the metrology of the (18)F is very important. The (18)F response normalized to the (137)Cs response shows that the difference with a reference value does not exceed 3% for the three types of radionuclide calibrators.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The IRA and the NPL have submitted ampoules of 166Hom to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures, thus becoming the third and fourth participants since 1989. The five samples of known activity of 166Hom now recorded in the SIR have activities between about 70 kBq and 500 kBq. The new results have enabled a re-evaluation of the key comparison reference value, and the degrees of equivalence between each equivalent activity measured in the SIR and the key comparison reference value (KCRV) have been calculated. The results are given in the form of a matrix for these four NMIs together with the recalculated degrees of equivalence of an APMP regional comparison held in 2000, comparison identifier APMP.RI(II)-K2.Ho-166m for six other NMIs. A graphical presentation is also given.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

ABSTRACT BACKGROUND: Chronic mountain sickness (CMS) is a major public health problem characterized by exaggerated hypoxemia and erythrocytosis. In more advanced stages, these patients often present functional and structural changes of the pulmonary circulation, but there is little information on the systemic circulation. In patients suffering from diseases associated with chronic hypoxemia at low altitude, systemic vascular function is altered. We hypothesized that patients with CMS display systemic vascular dysfunction that may predispose them to increased systemic cardiovascular morbidity. METHODS: To test this hypothesis, we assessed systemic endothelial function (by flow- mediated dilation, FMD), arterial stiffness and carotid intima-media thickness and arterial oxygenation (SaO(2)) in 23 patients with CMS without additional classical cardiovascular risk factors and 27 age-matched healthy mountain dwellers born and permanently living at 3600 m. For some analyses subjects were classified according to baseline SaO(2) quartiles; FMD of the highest quartile subgroup (SaO(2) ≥90%) was used as reference value for post-hoc comparisons. RESULTS: Patients with CMS displayed marked systemic vascular dysfunction, as evidenced by impaired FMD (4.6±1.2 vs. 7.6±1.9%, CMS vs. controls, P<0.0001), greater pulse wave velocity (10.6±2.1 vs. 8.4±1.0 m/s, P<0.001) and carotid intima-media thickness (690±120 vs. 570±110 μm, P=0.001). A positive relationship existed between SaO(2) and FMD (r=0.62, P<0.0001). Oxygen inhalation improved (P<0.001), but did not normalize FMD in patients with CMS; whereas it normalized FMD in hypoxemic controls (SaO(2) <90%) and had no detectable effect in normoxemic (SaO(2) ≥90%) control subjects. CONCLUSIONS: Patients with CMS display marked systemic vascular dysfunction. Structural and functional alterations contribute to this problem that may predispose these patients to premature cardiovascular disease. Clinical Trials Gov Registration # NCT01182792.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Congenital nephrogenic diabetes insipidus (CNDI) is a rare disease characterized by the inability of the kidney to respond to arginine vasopressin (AVP). The absence of the neurohypophyseal 'bright signal' on T1 sequence magnetic resonance imaging (MRI) is considered as an argument in favour of the diagnosis of central diabetes insipidus (CDI). This observation is challenged as we hereby present a case of a child diagnosed with CNDI and who did not present MRI pituitary bright signal. A 6-month-old male presented with failure to thrive, polyuria and polydypsia. Family history revealed that the mother, 35 years of age, had been presenting polydypsia and polyuria, and she was investigated at the age of 6 years with no concluding diagnosis. The patient's physical exam showed a weight of 5215 g (−3 DS) and clinical signs of dehydration. The patient's plasma sodium level was 155 mmol/L, osmolality 305 mOsm/kg and urine osmolality 150 mOsm/kg. Brain MRI showed in T1 sequences the absence of the posterior pituitary bright signal suggesting the diagnosis of CDI (Figure 1). The child was treated with synthetic AVP analogue 1-desamino-8-d-arginine vasopressin (DDAVP) without improvement, which led to the consideration of CNDI. The diagnosis was confirmed by an elevated serum level of AVP of 214 pmol/L (reference value ≤4.34 pmol/L) and by genetic analysis demonstrating and T106C mutation in the V2R (X-linked CNDI). The child was treated with thiazide diuretic and increased fluids with restricted sodium intake. This resulted in catch-up growth and improved neurological development. A follow-up MRI was performed 6 months after the start of therapy with the same technique. At that time, the child's weight had improved to 9310 g (−1.5 DS) corresponding to a gain of 22 g per day, and he did not present any clinical signs of dehydration and had a normal plasma level of sodium (140 mmol/L). MRI showed that the bright signal was still absent.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the realm of forensic pathology, β-tryptase measurement for diagnostic purposes is performed in postmortem serum obtained from femoral blood. This may be partially or completely unavailable in some specific cases, such as infant autopsies and severely damaged bodies. The aim of this study was to investigate the usefulness of determining β-tryptase levels for diagnostic purposes in alternative biological samples. Urine, vitreous humor and pericardial fluid were selected and measured in 94 subjects including: fatal anaphylaxis following contrast material administration (6 cases), hypothermia (10 cases), diabetic ketoacidosis (10 cases), gunshot suicide (10 cases), heroin injection-related deaths (18 cases), trauma (10 cases), sudden death with minimal coronary atherosclerosis (10 cases), severe coronary atherosclerosis without myocardial infarction (10 cases) and severe coronary atherosclerosis with myocardial infarction (10 cases). Postmortem serum and pericardial fluid β-tryptase levels higher than the clinical reference value (11.4ng/ml) were systematically identified in fatal anaphylaxis following contrast material administration and 6 cases unrelated to anaphylaxis. β-tryptase concentrations in urine and vitreous humor were lower than the clinical reference value in all cases included in this study. Determination of β-tryptase in pericardial fluid appears to be a possible alternative to postmortem serum in the early postmortem period when femoral blood cannot be collected during autopsy and biochemical investigations are required to objectify increased β-tryptase levels.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Ethical conflicts are arising as a result of the growing complexity of clinical care, coupled with technological advances. Most studies that have developed instruments for measuring ethical conflict base their measures on the variables"frequency" and"degree of conflict". In our view, however, these variables are insufficient for explaining the root of ethical conflicts. Consequently, the present study formulates a conceptual model that also includes the variable"exposure to conflict", as well as considering six"types of ethical conflict". An instrument was then designed to measure the ethical conflicts experienced by nurses who work with critical care patients. The paper describes the development process and validation of this instrument, the Ethical Conflict in Nursing Questionnaire Critical Care Version (ECNQ-CCV). Methods: The sample comprised 205 nursing professionals from the critical care units of two hospitals in Barcelona (Spain). The ECNQ-CCV presents 19 nursing scenarios with the potential to produce ethical conflict in the critical care setting. Exposure to ethical conflict was assessed by means of the Index of Exposure to Ethical Conflict (IEEC), a specific index developed to provide a reference value for each respondent by combining the intensity and frequency of occurrence of each scenario featured in the ECNQ-CCV. Following content validity, construct validity was assessed by means of Exploratory Factor Analysis (EFA), while Cronbach"s alpha was used to evaluate the instrument"s reliability. All analyses were performed using the statistical software PASW v19. Results: Cronbach"s alpha for the ECNQ-CCV as a whole was 0.882, which is higher than the values reported for certain other related instruments. The EFA suggested a unidimensional structure, with one component accounting for 33.41% of the explained variance. Conclusions: The ECNQ-CCV is shown to a valid and reliable instrument for use in critical care units. Its structure is such that the four variables on which our model of ethical conflict is based may be studied separately or in combination. The critical care nurses in this sample present moderate levels of exposure to ethical conflict. This study represents the first evaluation of the ECNQ-CCV.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Ethical conflicts are arising as a result of the growing complexity of clinical care, coupled with technological advances. Most studies that have developed instruments for measuring ethical conflict base their measures on the variables"frequency" and"degree of conflict". In our view, however, these variables are insufficient for explaining the root of ethical conflicts. Consequently, the present study formulates a conceptual model that also includes the variable"exposure to conflict", as well as considering six"types of ethical conflict". An instrument was then designed to measure the ethical conflicts experienced by nurses who work with critical care patients. The paper describes the development process and validation of this instrument, the Ethical Conflict in Nursing Questionnaire Critical Care Version (ECNQ-CCV). Methods: The sample comprised 205 nursing professionals from the critical care units of two hospitals in Barcelona (Spain). The ECNQ-CCV presents 19 nursing scenarios with the potential to produce ethical conflict in the critical care setting. Exposure to ethical conflict was assessed by means of the Index of Exposure to Ethical Conflict (IEEC), a specific index developed to provide a reference value for each respondent by combining the intensity and frequency of occurrence of each scenario featured in the ECNQ-CCV. Following content validity, construct validity was assessed by means of Exploratory Factor Analysis (EFA), while Cronbach"s alpha was used to evaluate the instrument"s reliability. All analyses were performed using the statistical software PASW v19. Results: Cronbach"s alpha for the ECNQ-CCV as a whole was 0.882, which is higher than the values reported for certain other related instruments. The EFA suggested a unidimensional structure, with one component accounting for 33.41% of the explained variance. Conclusions: The ECNQ-CCV is shown to a valid and reliable instrument for use in critical care units. Its structure is such that the four variables on which our model of ethical conflict is based may be studied separately or in combination. The critical care nurses in this sample present moderate levels of exposure to ethical conflict. This study represents the first evaluation of the ECNQ-CCV.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

B12-vitamiinin puute iäkkäillä: laboratoriodiagnostiikka, yleisyys ja yhteys sairastavuuteen Tausta: B12-vitamiinin puute on yleistä iäkkäillä ja se tulisi todeta riittävän varhaisessa vaiheessa palautumattomien vaurioiden estämiseksi. On epäselvää pitäisikö diagnostiikka kohdistaa tiettyihin riskiryhmiin vai mahdollisesti seuloa valikoimatonta vanhusväestöä. Myöskään yksimielisyyttä laboratoriotutkimusten valinnasta ei ole. Tavoitteet: Tutkimuksen tarkoituksena oli evaluoida uutta HoloTC RIA menetelmää ja tuottaa viitearvot sille, selvittää B12-vitamiinin puutteen yleisyys, yhteys sairastavuuteen ja mahdolliset riskitekijät suomalaisessa vanhusväestössä, arvioida munuaisfunktion vaikusta B12-vitamiinin puutteen laboratoriotutkimuksiin ja näiden perusteella ehdottaa suomalaiseen terveydenhuoltoon sopivaa laboratoriotutkimusstrategiaa. Aineisto ja menetelmät: Liedon iäkkäät -tutkimuksen vanhusaineisto on edustava otos yhden kunnan yli 65-vuotiaasta väestöstä, yhteensä 1260 henkilöä. Tutkittavat kävivät lääkärintarkastuksessa, ja heistä on käytettävissä runsaasti laboratoriotutkimuksia sekä tiedot sairauksista, ruokavaliosta, lääkkeiden ja vitamiinivalmisteiden käytöstä, dementiaseula ja depressiokysely. Viitearvoaineistoa varten kerättiin näytteet 84 vapaaehtoisesta terveestä aikuisesta ja menetelmäevaluaatiota varten 107 sairaalapotilaasta. Tulokset: HoloTC RIA menetelmän toistettavuus oli hyvä manuaalimenetelmäksi. 95%:n viiteväli holotranskobalamiinille oli 37-171 pmol/l. Kaikilla tutkittavilla, joilla oli muilla laboratoriotutkimuksilla osoitettu todennäköinen B12-vitamiinin puute, myös holotranskobalamiini oli viitealueen alarajaa pienempi. Suurentuneella kystatiini C-pitoisuudella osoitettu munuaisten vajaatoiminta korreloi voimakkaasti homokysteiinin (rs=0.53, p<0.001) ja metyylimalonihapon (rs=0.27, p<0.001) pitoisuuksiin, mutta ei kokonais-B12-vitamiinin (rs=- 0.04, p=0.227) tai holotranskobamiinin (rs=-0.01, p=0.817) pitoisuuksiin. Suomalaisessa vanhusväestössä B12-vitamiinin puutteen prevalenssi oli 12%. Kokonais- B12-vitamiinin pitoisuus oli matala (<150 pmol/l) 6%:lla. Miessukupuoli (OR 1.9, 95% CI 1.2-2.9), ikä ≥75 (OR 2.2, 95% CI 1.4-3.4) ja maitotuotteiden välttäminen (OR 2.3, 95% CI 1.2-4.4) lisäsivät B12-vitamiinin puutteen riskiä, mutta anemia (OR 1.3, 95% CI 0.7-2.3) tai makrosytoosi (OR 1.2, 95% CI 0.6-2.7) eivät. Päätelmät: Diagnosoimaton B12-vitamiinin puute on yleistä iäkkäillä, mutta kliinisesti merkityksellistä spesifistä riskiryhmää ei löydy. Koska anemian ja makrosytoosin puuttuminen ei poissulje B12-vitamiinin puutetta ja munuaisten vajaatoiminta heikentää metabolisten merkkiaineiden käyttökelpoisuutta, kokonais-B12-vitamiinia suositellaan ensisijaiseksi laboratoriotutkimukseksi epäiltäessä B12-vitamiinin puutetta ja tarvittaessa varmentavina tutkimuksina käytetään homokysteiiniä ja holotranskobalamiinia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Asiakkuuden hallinnassa tärkeä asia on olemassa olevien asiakkaiden kannattavuus. Asiakkuutta voidaan arvostaa muillakin mittareilla: volyymi, asiakkuuden kesto, asiakasosuus, referenssiarvo ja osaamisarvo. Työssä selvitetään asiakaskannattavuuden laskemista esimerkkiyrityksessä. Asiakaskannattavuuden laskemiseksi asiakashallintaan rakennettiin asiakastasot. Asiakasrakennetta tutkittiin ja määriteltiin avainasiakkaat. Avainasiakkaita tarkasteltiin useista näkökulmista, joista yksi oli asiakaskannattavuus. Lopputuloksena saatiin asiakastasomäärittelyt ja malliraportteja, joilla myynti voi tarkastella asiakkaitaan sekä näiden vaikutusta yrityksen strategiaan.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Ethical conflicts are arising as a result of the growing complexity of clinical care, coupled with technological advances. Most studies that have developed instruments for measuring ethical conflict base their measures on the variables"frequency" and"degree of conflict". In our view, however, these variables are insufficient for explaining the root of ethical conflicts. Consequently, the present study formulates a conceptual model that also includes the variable"exposure to conflict", as well as considering six"types of ethical conflict". An instrument was then designed to measure the ethical conflicts experienced by nurses who work with critical care patients. The paper describes the development process and validation of this instrument, the Ethical Conflict in Nursing Questionnaire Critical Care Version (ECNQ-CCV). Methods: The sample comprised 205 nursing professionals from the critical care units of two hospitals in Barcelona (Spain). The ECNQ-CCV presents 19 nursing scenarios with the potential to produce ethical conflict in the critical care setting. Exposure to ethical conflict was assessed by means of the Index of Exposure to Ethical Conflict (IEEC), a specific index developed to provide a reference value for each respondent by combining the intensity and frequency of occurrence of each scenario featured in the ECNQ-CCV. Following content validity, construct validity was assessed by means of Exploratory Factor Analysis (EFA), while Cronbach"s alpha was used to evaluate the instrument"s reliability. All analyses were performed using the statistical software PASW v19. Results: Cronbach"s alpha for the ECNQ-CCV as a whole was 0.882, which is higher than the values reported for certain other related instruments. The EFA suggested a unidimensional structure, with one component accounting for 33.41% of the explained variance. Conclusions: The ECNQ-CCV is shown to a valid and reliable instrument for use in critical care units. Its structure is such that the four variables on which our model of ethical conflict is based may be studied separately or in combination. The critical care nurses in this sample present moderate levels of exposure to ethical conflict. This study represents the first evaluation of the ECNQ-CCV.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Ethical conflicts are arising as a result of the growing complexity of clinical care, coupled with technological advances. Most studies that have developed instruments for measuring ethical conflict base their measures on the variables"frequency" and"degree of conflict". In our view, however, these variables are insufficient for explaining the root of ethical conflicts. Consequently, the present study formulates a conceptual model that also includes the variable"exposure to conflict", as well as considering six"types of ethical conflict". An instrument was then designed to measure the ethical conflicts experienced by nurses who work with critical care patients. The paper describes the development process and validation of this instrument, the Ethical Conflict in Nursing Questionnaire Critical Care Version (ECNQ-CCV). Methods: The sample comprised 205 nursing professionals from the critical care units of two hospitals in Barcelona (Spain). The ECNQ-CCV presents 19 nursing scenarios with the potential to produce ethical conflict in the critical care setting. Exposure to ethical conflict was assessed by means of the Index of Exposure to Ethical Conflict (IEEC), a specific index developed to provide a reference value for each respondent by combining the intensity and frequency of occurrence of each scenario featured in the ECNQ-CCV. Following content validity, construct validity was assessed by means of Exploratory Factor Analysis (EFA), while Cronbach"s alpha was used to evaluate the instrument"s reliability. All analyses were performed using the statistical software PASW v19. Results: Cronbach"s alpha for the ECNQ-CCV as a whole was 0.882, which is higher than the values reported for certain other related instruments. The EFA suggested a unidimensional structure, with one component accounting for 33.41% of the explained variance. Conclusions: The ECNQ-CCV is shown to a valid and reliable instrument for use in critical care units. Its structure is such that the four variables on which our model of ethical conflict is based may be studied separately or in combination. The critical care nurses in this sample present moderate levels of exposure to ethical conflict. This study represents the first evaluation of the ECNQ-CCV.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to estimate the diagnostic value of renal cortex copper (Cu) concentration in clinical cases of acute copper poisoning (ACP). A total of 97 calves that died due to subcutaneous copper administration were compiled in eleven farms. At least, one necropsy was conducted on each farm and samples for complementary analysis were taken. The degree of autolysis in each necropsy was evaluated. The cases appeared on extensive grazing calf breeding and intensive feedlot farms, in calves of 60 to 200 kg body weight. Mortality varied from 0.86 to 6.96 %, on the farms studied. The first succumbed calf was found on the farms between 6 and 72 hours after the susbcutaneous Cu administration. As discrepancies regarding the reference value arose, the local value (19.9 parts per million) was used, confirming the diagnosis of acute copper poisoning in 93% of the analyzed kidney samples. These results confirm the value of analysis of the cortical kidney Cu concentration for the diagnosis of acute copper poisoning.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hypoferremia observed during systemic inflammatory disorders is regulated by hepcidin. Hepcidin up-regulation is particularly important during acute inflammation, as it restricts the availability of iron, which is necessary for pathogenic microorganism growth before adaptive immunity occurs. The aim of this study was to evaluate the clinical findings and hepatic hepcidin mRNA expression in horses using a Freund's complete adjuvant (FCA) model of inflammation. The expression of hepcidin mRNA in the liver was determined in healthy horses following two intramuscular injections of FCA at 0 h and 12 h. Plasma iron and fibrinogen concentrations were measured at multiple time points between 0 h and 240 h post-FCA injection (PI). Hepcidin mRNA expression was determined by RT-qPCR using liver biopsy samples performed at 0 h (control), 6 h and 18 h PI. The mean plasma fibrinogen level was significantly different from the control values only between 120 and 216 h PI. The mean plasma iron level was significantly lower than the control between 16 and 72 h PI, reaching the lowest levels at 30 h PI (33 % of the initial value), and returned to the reference value from 96 h PI to the end of the experiment. Hepcidin mRNA expression increased at 6 h PI and remained high at 18 h PI. The iron plasma concentration was an earlier indicator of inflammatory processes in horses when compared with fibrinogen and might be useful for the early detection of inflammation in the horse. FCA administration caused the rapid onset of hypoferremia, and this effect was likely the result of up-regulated hepatic hepcidin gene expression. This study emphasizes the importance of hepcidin and iron metabolism during inflammation in horses.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Chaotic dynamical systems exhibit trajectories in their phase space that converges to a strange attractor. The strangeness of the chaotic attractor is associated with its dimension in which instance it is described by a noninteger dimension. This contribution presents an overview of the main definitions of dimension discussing their evaluation from time series employing the correlation and the generalized dimension. The investigation is applied to the nonlinear pendulum where signals are generated by numerical integration of the mathematical model, selecting a single variable of the system as a time series. In order to simulate experimental data sets, a random noise is introduced in the time series. State space reconstruction and the determination of attractor dimensions are carried out regarding periodic and chaotic signals. Results obtained from time series analyses are compared with a reference value obtained from the analysis of mathematical model, estimating noise sensitivity. This procedure allows one to identify the best techniques to be applied in the analysis of experimental data.