933 resultados para real-time quantitative PCR


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lymphocytic choriomeningitis virus (LCMV) is a rare cause of central nervous system disease in humans. Screening by real-time RT-PCR assay is of interest in the case of aseptic meningitis of unknown etiology. A specific LCMV real-time RT-PCR assay, based on the detection of genomic sequences of the viral nucleoprotein (NP), was developed to assess the presence of LCMV in cerebrospinal fluids (CSF) sent for viral screening to a Swiss university hospital laboratory. A 10-fold dilution series assay using a plasmid containing the cDNA of the viral NP of the LCMV isolate Armstrong (Arm) 53b demonstrated the high sensitivity of the assay with a lowest detection limit of ≤50 copies per reaction. High sensitivity was confirmed by dilution series assays in a pool of human CSF using four different LCMV isolates (Arm53b, WE54, Traub and E350) with observed detection limits of ≤10PFU/ml (Arm53b and WE54) and 1PFU/ml (Traub and E350). Analysis of 130 CSF showed no cases of acute infection. The absence of positive cases was confirmed by a published PCR assay detecting all Old World arenaviruses. This study validates a specific and sensitive real-time RT-PCR assay for the diagnosis of LCMV infections. Results showed that LCMV infections are extremely rare in hospitalized patients western in Switzerland.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This report describes the development of a SYBR Green I based real time polymerase chain reaction (PCR) protocol for detection on the ABI Prism 7000 instrument. Primers targeting the gene encoding the SSU rRNA were designed to amplify with high specificity DNA from Schistosoma mansoni, in a real time quantitative PCR system. The limit of detection of parasite DNA for the system was 10 fg of purified genomic DNA, that means less than the equivalent to one parasite cell (genome ~580 fg DNA). The efficiency was 0.99 and the correlation coefficient (R²) was 0.97. When different copy numbers of the target amplicon were used as standards, the assay could detect at least 10 copies of the specific target. The primers used were designed to amplify a 106 bp DNA fragment (Tm 83ºC). The assay was highly specific for S. mansoni, and did not recognize DNA from closely related non-schistosome trematodes. The real time PCR allowed for accurate quantification of S. mansoni DNA and no time-consuming post-PCR detection of amplification products by gel electrophoresis was required. The assay is potentially able to quantify S. mansoni DNA (and indirectly parasite burden) in a number of samples, such as snail tissue, serum and feces from patients, and cercaria infested water. Thus, these PCR protocols have potential to be used as tools for monitoring of schistosome transmission and quantitative diagnosis of human infection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to evaluate the use of conventional polymerase chain reaction (cPCR) and real-time quantitative PCR (qPCR) in the diagnosis of human strongyloidiasis from stool samples in tropical areas. Stool samples were collected from individuals and were determined to be positive for Strongyloides stercoralis (group I), negative for S. stercoralis (group II) and positive for other enteroparasite species (group III). DNA specific to S. stercoralis was found in 76.7% of group I samples by cPCR and in 90% of group I samples by qPCR. The results show that molecular methods can be used as alternative tools for detecting S. stercoralis in human stool samples in tropical areas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A total of 49 wastewater samples from 23 different wastewater treatment plants (WWTPs) were analyzed using real-time quantitative polymerase chain reaction for the presence and quantity of thermotolerant campylobacters. Thermotolerant campylobacters were detected in 87.5% (21/24) and 64% (16/25) of untreated and treated wastewater samples, respectively. Their concentration was sufficiently high to be quantified in 20.4% (10/49) of the samples. In these samples, the concentration ranged from 68 000 to 2292 000 cells/L in untreated wastewater and from 10 800 to 28 000 cells/L in treated water. We conclude that thermotolerant campylobacters present a health hazard for workers at WWTPs in Switzerland. [Authors]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

By the end of 2004, the Canadian swine population had experienced a severe 2 increase in the incidence of Porcine circovirus-associated disease (PCVAD), a problem that was 3 associated with the emergence of a new Porcine circovirus-2 genotype (PCV-2b), previously 4 unrecovered in North America. Thus it became important to develop a diagnostic tool that could 5 differentiate between the old and new circulating genotypes (PCV-2a and -2b, respectively). 6 Consequently, a multiplex real-time quantitative polymerase chain reaction (mrtqPCR) assay that 7 could sensitively and specifically identify and differentiate PCV-2 genotypes was developed. A 8 retrospective epidemiological survey that used the mrtqPCR assay was performed to determine if 9 cofactors could affect the risk of PCVAD. From 121 PCV-2–positive cases gathered for this 10 study, 4.13%, 92.56% and 3.31% were positive for PCV-2a, PCV-2b, and both genotypes, 11 respectively. In a data analysis using univariate logistic regressions, PCVAD compatible 12 (PCVAD/c) score was significantly associated with the presence of Porcine reproductive and 13 respiratory syndrome virus (PRRSV), PRRSV viral load, PCV-2 viral load, and PCV-2 14 immunohistochemistry (IHC) results. Polytomous logistic regression analysis revealed that 15 PCVAD/c score was affected by PCV-2 viral load (P = 0.0161) and IHC (P = 0.0128), but not by 16 the PRRSV variables (P > 0.9); suggesting that mrtqPCR in tissue is a reliable alternative to IHC. 17 Logistic regression analyses revealed that PCV-2 increased the odds ratio of isolating 2 major 18 swine pathogens of the respiratory tract, Actinobacillus pleuropneumoniae and Streptococcus 19 suis serotypes 1/2, 1, 2, 3, 4, and 7, which are serotypes commonly associated with clinical 20 diseases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Current knowledge of the pathogenic hantavirus indicates that wild rodents are its primary natural reservoir. Specific primers to detect the presence of viral genomes were developed using an SYBR-Green-based real-time RT-PCR protocol. One hundred sixty-four rodents native to the Atlantic Forest biome were captured in So Paulo State, Brazil, and their tissues were tested. The presence of hantavirus RNA was detected in sixteen rodents: three specimens of Akodon montensis, three of Akodon cursor, two of Necromys lasiurus, one of Juliomys sp., one of Thaptomys nigrita, five of Oligoryzomys nigripes, and one of Oryzomys sp. This SYBR Green real-time RT-PCR method for detection of hantavirus may be useful for surveying hantaviruses in Brazil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fast-track Diagnostics respiratory pathogens (FTDRP) multiplex real-time RT-PCR assay was compared with in-house singleplex real-time RT-PCR assays for detection of 16 common respiratory viruses. The FTDRP assay correctly identified 26 diverse respiratory virus strains, 35 of 41 (85%) external quality assessment samples spiked with cultured virus and 232 of 263 (88%) archived respiratory specimens that tested positive for respiratory viruses by in-house assays. Of 308 prospectively tested respiratory specimens selected from children hospitalized with acute respiratory illness, 270 (87.7%) and 265 (86%) were positive by FTDRP and in-house assays for one or more viruses, respectively, with combined test results showing good concordance (K=0.812, 95% CI = 0.786-0.838). Individual FTDRP assays for adenovirus, respiratory syncytial virus and rhinovirus showed the lowest comparative sensitivities with in-house assays, with most discrepancies occurring with specimens containing low virus loads and failed to detect some rhinovirus strains, even when abundant. The FTDRP enterovirus and human bocavirus assays appeared to be more sensitive than the in-house assays with some specimens. With the exceptions noted above, most FTDRP assays performed comparably with in-house assays for most viruses while offering enhanced throughput and easy integration by laboratories using conventional real-time PCR instrumentation. Published by Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

1) Background: The most common methods to evaluate clarithromycin resistance is the E-Test, but is time consuming. Resistance of Hp to clarithromycin is due to point mutations in the 23S rRNA. Eight different point mutations have been related to CH resistance, but the large majority of the clarithromycin resistance depends on three point mutations (A2142C, A2142G and A2143G). A novel PCR-based clarithromycin resistance assays, even on paraffin-embedded biopsy specimens, have been proposed. Aims: to assess clarithromycin resistance detecting these point mutation (E-Test as a reference method);secondly, to investigate relation with MIC values. Methods: Paraffin-embedded biopsies of patients Hp-positive were retrieved. The A2142C, A2142G and A2143G point mutations were detected by molecular analysis after DNA extraction by using a TaqMan real-time PCR. Results: The study enrolled 86 patients: 46 resistant and 40 sensible to CH. The Hp status was evaluated at endoscopy, by rapid urease test (RUT), histology and hp culture. According to real-time PCR, 37 specimens were susceptible to clarithromycin (wild type dna) whilst the remaining 49 specimens (57%) were resistant. A2143G is the most frequent mutation. A2142C always express a resistant phenotype and A2142G leads to a resitant phenotype only if homozigous. 2) Background: Colonoscopy work-load for endoscopy services is increasing due to colorectal cancer prevention. We tested a combination of faecal tests to improve accuracy and prioritize the access to colonoscopy. Methods: we tested a combination of fecal tests (FOBT, M2-PK and calprotectin) in a group of 280 patients requiring colonoscopy. Results: 47 patients had CRC and 85 had advanced adenoma/s at colonoscopy/histology. In case of single test, for CRC detection FOBT was the test with the highest specificity and PPV, M2-PK had the highest sensitivity and higher NPV. Combination was more interesting in term of PPV. And the best combination of tests was i-FOBT + M2-PK.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Il primo capitolo di questo lavoro di tesi introduce i concetti di biologia necessari per comprendere il fenomeno dell’espressione genica. Il secondo capitolo descrive i metodi e le tecniche di laboratorio utilizzate per ottenere il cDNA, il materiale genetico che verrà amplificato nella real-time PCR. Nel terzo capitolo si descrive la tecnica di real-time PCR, partendo da una descrizione della PCR convenzionale fino a delineare le caratteristiche della sua evoluzione in real-time PCR. Si prosegue con la spiegazione del principio fisico alla base della tecnica e delle molecole necessarie (fluorofori e sonde) per realizzarla; infine si descrive l’hardware e il software dello strumento. Il quarto capitolo presenta le tecniche di analisi del segnale che utilizzano metodi di quantificazione assoluta o relativa. Infine nel quinto capitolo è presentato un caso di studio, cioè un’analisi di espressione genica con real-time PCR condotta durante l’esperienza di tirocinio presso il laboratorio ICM. e delle molecole necessarie (fluorofori e sonde) per realizzarla; infine si descrive l’hardware e il software dello strumento. Il quarto capitolo presenta le tecniche di analisi del segnale che utilizzano metodi di quantificazione assoluta o relativa. Infine nel quinto capitolo è presentato un caso di studio, cioè un’analisi di espressione genica con real-time PCR condotta durante l’esperienza di tirocinio presso il laboratorio ICM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Real-time quantitative polymerase chain reaction (qPCR) depends on precise temperature control of the sample during cycling. In the current study, we investigated how temperature variation in plate-based qPCR instruments influences qPCR results. Temperature variation was measured by amplicon melting analysis as a convenient means to assess well-to-well differences. Multiple technical replicates of several SYBR Green I-based qPCR assays allowed correlation of relative well temperature to quantification cycle. We found that inadequate template denaturation results in an inverse correlation and requires increasing the denaturation temperature, adding a DNA destabilizing agent, or pretreating with a restriction enzyme. In contrast, inadequate primer annealing results in a direct correlation and requires lowering the annealing temperature. Significant correlations were found in 18 of 25 assays. The critical nature of temperature-dependent effects was shown in a blinded study of 29 patients for the diagnosis of Prader-Willy and Angelman syndromes, where eight diagnoses were incorrect unless temperature-dependent effects were controlled. A method to detect temperature-dependent effects by pairwise comparisons of replicates in routine experiments is presented and applied. Systematic temperature errors in qPCR instruments can be recognized and their effects eliminated when high precision is required in quantitative genetic diagnostics and critical complementary DNA analyses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel real-time quantitative PCR assay for detecting the pathogenic and contagious Staphylococcus aureus genotype B (GTB) in bulk tank milk was developed and evaluated. The detection of this pathogen in bulk tank milk would greatly facilitate its control, as it is responsible for great economic loss in Swiss dairy herds. The assay is based on the simultaneous detection of 3 GTB-typical target sequences, including 2 enterotoxin genes and a polymorphism within the leucotoxin E gene. A variety of mastitis-associated bacteria was used to validate the assays, resulting in an analytical specificity of 100% and high repeatability. The analytical sensitivity in milk was 40 cfu/mL. An exponential association between simulated cow prevalence and quantitative PCR result was observed. An initial field study revealed 1 GTB-positive herd among the 33 studied herds. This novel assay for bulk tank milk analysis is suitable for routine purposes and is expected to be an effective tool for minimizing Staph. aureus GTB in Swiss dairy herds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Typing of Clostridium perfringens strains by PCR-based determination of toxin genes proved to be a reliable method for diagnosis of enterotoxaemia in various animal species. We report the establishment and validation of three real-time fluorogenic (TaqMan) multiplex PCRs for the detection of C. perfringens alpha-, beta-, beta2-, epsilon-, entero- and iota-toxin genes. The composition of the PCRs was chosen with regard to robustness of the assays and in order to increase sensitivity compared to the conventional simplex PCRs. The combination of probe dyes selected for the real-time assays (FAM/TAMRA, Cy-5/BHQ-2 and VIC/TAMRA) as well as the designation of the chromosome-borne alpha-toxin as internal positive control allowed the creation of highly specific and sensitive, as well as time and cost effective PCRs. One hundred and three strains of C. perfringens isolated in Switzerland derived from clinical or suspected cases of enterotoxaemia in 10 different animal species were tested. The toxin genotypes were in agreement in both the conventional PCRs and the newly designed multiplex PCRs. Furthermore, the real-time PCR carried out as simplex allows to quantitate the copy numbers of plasmid-borne toxin genes in relation to the chromosomally located alpha-toxin gene.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The causative agents of rabies are single-stranded, negative-sense RNA viruses in the genus Lyssavirus of Rhabdoviridae, consisting of twelve classified and three as yet unclassified species including classical rabies virus (RABV). Highly neurotropic RABV causes rapidly progressive encephalomyelitis with nearly invariable fatal outcome. Rapid and reliable diagnosis of rabies is highly relevant for public and veterinary health. Due to growing variety of the genus Lyssavirus observed, the development of suitable molecular assays for diagnosis and differentiation is challenging. This work focused on the establishment of a suitable real-time RT-PCR technique for rabies diagnosis as a complement to fluorescent antibody test and rabies tissue culture infection test as gold standard for diagnosis and confirmation. The real-time RT-PCR was adapted with the goal to detect the whole spectrum of lyssavirus species, for nine of which synthesized DNA fragments were used. For the detection of species, seven probes were developed. Serial dilutions of the rabies virus strain CVS-11 showed a 100-fold higher sensitivity of real-time PCR compared to heminested RT-PCR. Using a panel of thirty-one lyssaviruses representing four species, the suitability of the protocol could be shown. Phylogenetic analysis of the sequences obtained by heminested PCR allowed correct classification of all viruses used.