971 resultados para occlusal loads


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The purpose of this study was to evaluate the cephalometric and occlusal changes, the functional occlusion, and the dentinal sensitivity of anterior open-bite treatment with occlusal adjustment. Methods: The sample comprised 20 patients who experienced relapse of the anterior open bite (mean, -1.06 mm). Occlusal adjustment was performed until a positive overbite was established. Cephalometric changes were evaluated on lateral cephalograms taken before and after the occlusal adjustment. The functional occlusion analysis consisted of evaluating immediate anterior and canine guidance and the number of teeth in contact before and after the procedure. Dentinal sensitivity was evaluated before, shortly after, and 4.61 months after the occlusal adjustment. Pretreatment and posttreatment cephalometric changes and the number of teeth in contact were compared with dependent t tests. Percentages of anterior and canine guidance before and after the adjustment procedure were compared with the McNemar test. To compare dentinal sensitivity at several stages, the nonparametric Friedman test was used, followed by the Wilcoxon test. Results: Significant increases in overbite and mandibular protrusion were seen, as were significant decreases in apical base discrepancy, facial convexity, and growth pattern angles. The percentages of immediate anterior and canine guidance increased significantly, as did the number of teeth with occlusal contacts. Dentinal sensitivity increased immediately after the adjustment but decreased to normal levels after 4.61 months. Conclusions: Occlusal adjustment is a viable treatment alternative for some open-bite patients; it establishes positive vertical overbite and improves the functional occlusion with only transient dentinal sensitivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The objectives of this investigation were to compare the initial cephalometric characteristics of complete Class II Division 1 malocclusions treated with 2 or 4 premolar extractions and to verify their influence on the occlusal success rate of these treatment protocols. Methods: A sample of 98 records from patients with complete Class II Division 1 malocclusion was divided into 2 groups with the following characteristics: group 1 consisted of 55 patients treated with 2 maxillary first premolar extractions at an initial mean age of 13.07 years; group 2 included 43 patients treated with 4 premolar extractions, with an initial mean age of 12.92 years. Initial and final occlusal statuses were evaluated on dental casts with Grainger`s treatment priority index (TPI), and the initial cephalometric characteristics were obtained from the pretreatment cephalograms. The initial cephalometric characteristics and the initial and final occlusal statuses of the groups were compared with the t test. A multiple regression analysis was used to evaluate the influence of all variables in the final TPI. Results: The 2-premolar extraction protocol provided a statistically smaller TPI and consequently a better occlusal success rate than the 4-premolar extraction protocol. The 4-premolar extraction group had statistically smaller apical base lengths, more vertical facial growth patterns, and greater hard- and soft-tissue convexities at pretreatment than the 2-premolar extraction group. However, the multiple regression analysis showed that only the extraction protocol was significantly associated with the final occlusal status. Conclusions: The initial cephalometric characteristics of the groups did not influence the occlusal success rate of these 2 treatment protocols.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The purpose of this study was to compare the occlusal outcomes and the efficiency of 1-phase and 2-phase treatment protocols in Class II Division 1 malocclusions. Treatment efficiency was defined as a change in the occlusal characteristics in a shorter treatment time. Methods: Class II Division 1 subjects ( n = 139) were divided into 2 groups according to the treatment protocol for Class II correction. Group 1 comprised 78 patients treated with a 1-phase treatment protocol at initial and final mean ages of 12.51 and 14.68 years. Group 2 comprised 61 patients treated with a 2-phase treatment protocol at initial and final mean ages of 11.21 and 14.70 years. Lateral cephalometric radiographs were taken at the pretreatment stage to evaluate morphological differences in the groups. The initial and final study models of the patients were evaluated by using the peer assessment rating index. Chi-square tests were used to test for differences between the 2 groups for categorical variables. Variables regarding occlusal results were compared by using independent t tests. A linear regression analysis was completed, with total treatment time as the dependent variable, to identify clinical factors that predict treatment length for patients with Class II malocclusions. Results: Similar occlusal outcomes were obtained between the 1-phase and the 2-phase treatment protocols, but the duration of treatment was significantly shorter in the 1-phase treatment protocol group. Conclusions: Treatment of Class II Division 1 malocclusions is more efficient with the 1-phase than the 2-phase treatment protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To test the strength to failure and fracture mode of three indirect composite materials directly applied onto Ti-6Al-4V implant abutments vs cemented standard porcelain-fused-to-metal (PFM) crowns. Materials and Methods: Sixty-four locking taper abutments were randomly allocated to four groups and were cleaned in ethanol in an ultrasonic bath for 5 min. After drying under ambient conditions, the abutments were grit blasted and a custom 4-cusp molar crown mold was utilized to produce identical crowns (n = 16 per group) of Tescera (Bisco), Ceramage (Shofu), and Diamond Crown (DRM) according to the manufacturer`s instructions. The porcelain-fused-to-metal crowns were fabricated by conventional means involving the construction and a wax pattern and casting of a metallic coping followed by sintering of increasing layers of porcelain. All crowns were loaded to failure by an indenter placed at one of the cusp tips at a 1 mm/min rate. Subsequently, fracture analysis was performed by means of stereomicroscopy and scanning electron microscopy. One-way ANOVA at 95% level of significance was utilized for statistical analysis. Results: The single load to failure (+/- SD) results were: Tescera (1130 +/- 239 N), Ceramage (1099 +/- 257 N), Diamond Crown (1155 +/- 284 N), and PFM (1081 +/- 243 N). Stereomicroscopy analysis showed two distinct failure modes, where the loaded cusp failed either with or without abutment/metallic coping exposure. SEM analysis of the fractures showed multiple crack propagation towards the cervical region of the crown below a region of plastic deformation at the indenter contact region. Conclusion: The three indirect composites and PFM systems fractured at loads higher than those typically associated with normal occlusal function. Although each material had a different composition and handling technique, no significant differences were found concerning their single load to fracture resistance among composite systems and PFM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To verify the influence of cavity access diameter on demineralized dentin removal in the ART approach. Methods: 40 non-carious human premolars were randomly divided into four groups. The occlusal surface was ground flat and the teeth were sectioned mesio-distally. The hemi-sections were reassembled and occlusal access preparations were carried out using ball-shaped diamonds. The resulting size of the occlusal opening was 1.0 mm, 1.4 mm, 1.6 mm and 1.8 mm for Groups A, B, C, and D, respectively. Standardized artificial carious lesions were created and demineralized dentin was excavated. After excavation, the cavities were analyzed using: (a) the tactile method, (b) caries-detection dye to stain demineralized dentin, as proposed by Smales & Fang, and (c) Demineralized Tissue Removal index, as proposed in this study. Statistical analysis was performed using Fisher, Spearman correlation coefficient, kappa, Kruskal-Wallis and Miller tests (P < 0.05). Results: The three methods of evaluation showed no significant difference between Groups A vs. B, and C vs. D, while statistically significant differences were observed between Groups A vs. C, A vs. D, B vs. C and B vs. D. Based on the results of this study, the size of occlusal access significantly affected the efficacy of demineralized tissue removal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the limit state design (LSD) method each design criterion is formally stated and assessed using a performance function. The performance function defines the relationship between the design parameters and the design criterion. In practice, LSD involves factoring up loads and factoring down calculated strengths and material parameters. This provides a convenient way to carry out routine probabilistic-based design. The factors are statistically calculated to produce a design with an acceptably low probability of failure. Hence the ultimate load and the design material properties are mathematical concepts that have no physical interpretation. They may be physically impossible. Similarly, the appropriate analysis model is also defined by the performance function and may not describe the real behaviour at the perceived physical equivalent limit condition. These points must be understood to avoid confusion in the discussion and application of partial factor LSD methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experiment was performed to characterise the movement kinematics and the electromyogram (EMG) during rhythmic voluntary flexion and extension of the wrist against different compliant (elastic-viscous-inertial) loads. Three levels of each type of load, and an unloaded condition, were employed. The movements were paced at a frequency of I Hz by an auditory metronome, and visual feedback of wrist displacement in relation to a target amplitude of 100degrees was provided. Electro-myographic recordings were obtained from flexor carpi radialis (FCR) and extensor carpi radialis brevis (ECR). The movement profiles generated in the ten experimental conditions were indistinguishable, indicating that the CNS was able to compensate completely for the imposed changes in the task dynamics. When the level of viscous load was elevated, this compensation took the form of an increase in the rate of initial rise of the flexor and the extensor EMG burst. In response to increases in inertial load, the flexor and extensor EMG bursts commenced and terminated earlier in the movement cycle, and tended to be of greater duration. When the movements were performed in opposition to an elastic load, both the onset and offset of EMG activity occurred later than in the unloaded condition. There was also a net reduction in extensor burst duration with increases in elastic load, and an increase in the rate of initial rise of the extensor burst. Less pronounced alterations in the rate of initial rise of the flexor EMG burst were also observed. In all instances, increases in the magnitude of the external load led to elevations in the overall level of muscle activation. These data reveal that the elements of the central command that are modified in response to the imposition of a compliant load are contingent, not only upon the magnitude, but also upon the character of the load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The large penetration of intermittent resources, such as solar and wind generation, involves the use of storage systems in order to improve power system operation. Electric Vehicles (EVs) with gridable capability (V2G) can operate as a means for storing energy. This paper proposes an algorithm to be included in a SCADA (Supervisory Control and Data Acquisition) system, which performs an intelligent management of three types of consumers: domestic, commercial and industrial, that includes the joint management of loads and the charge/discharge of EVs batteries. The proposed methodology has been implemented in a SCADA system developed by the authors of this paper – the SCADA House Intelligent Management (SHIM). Any event in the system, such as a Demand Response (DR) event, triggers the use of an optimization algorithm that performs the optimal energy resources scheduling (including loads and EVs), taking into account the priorities of each load defined by the installation users. A case study considering a specific consumer with several loads and EVs is presented in this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine the prevalence and severity of occlusal problems in populations at the ages of deciduous and permanent dentition and to carry out a meta-analysis to estimate the weighted odds ratio for occlusal problems comparing both groups. METHODS: Data of a probabilistic sample (n=985) of schoolchildren aged 5 and 12 from an epidemiological study in the municipality of São Paulo, Brazil, were analyzed using univariate logistic regression (MLR). Results of cross-sectional study data published in the last 70 years were examined in the meta-analysis. RESULTS: The prevalence of occlusal problems increased from 49.0% (95% CI =47.4%-50.6%) in the deciduous dentition to 71.3% (95% CI =70.3%-72.3%) in the permanent dentition (p<0.001). Dentition was the only variable significantly associated to the severity of malocclusion (OR=1.87; 95% CI =1.43-2.45; p<0.001). The variables sex, type of school and ethnic group were not significant. The meta-analysis showed that a weighted OR of 1.95 (1.91; 1.98) when compared the second dentition period with deciduous and mixed dentition. CONCLUSIONS: In planning oral health services, some activities are indicated to reduce the proportion of moderate/severe malocclusion to levels that are socially more acceptable and economically sustainable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gravity loads can affect a reinforced concrete structure's response to seismic actions, however, traditional procedures for testing the beam behaviour do not take this effect into consideration. An experimental campaign was carried out in order to assess the influence of the gravity load on RC beam connection to the column subjected to cyclic loading. The experiments included the imposition of a conventional quasi-static test protocol based on the imposition of a reverse cyclic displacement history and of an alternative cyclic test procedure starting from the gravity load effects. The test results are presented, compared and analysed in this paper. The imposition of a cyclic test procedure that included the gravity loads effects on the RC beam ends reproduces the demands on the beams' critical zones more realistically than the traditional procedure. The consideration of the vertical load effects in the test procedure led to an accumulation of negative (hogging) deformation. This phenomenon is sustained with the behaviour of a portal frame system under cyclic loads subject to a significant level of the vertical load, leading to the formation of unidirectional plastic hinges. In addition, the hysteretic behaviour of the RC beam ends tested was simulated numerically using the nonlinear structural analysis software - OpenSees. The beam-column model simulates the global element behaviour very well, as there is a reasonable approximation to the hysteretic loops obtained experimentally. (C) 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was designed to investigate the impact of anti-retroviral therapy on both plasma and seminal HIV-1 viral loads and the correlation between viral loads in these compartments after treatment. Viral load, CD4+ and CD8+ T-cell counts were evaluated in paired plasma and semen samples from 36 antiretroviral therapy-naïve patients at baseline and on days 45, 90, and 180 of treatment. Slopes for blood and seminal viral loads in all treated patients were similar (p = 0.21). Median HIV-1 RNA titers in plasma and semen at baseline were 4.95 log10 and 4.48 log10 copies/ml, respectively. After 180 days of therapy, the median viral load declined to 3.15 log10 copies/ml (plasma) and 3.2 log10 copies/ml (semen). At this timepoint 22 patients presented HIV-1 viral load below 400 copies/ml in either plasma or semen, but only 9 had viral loads below 400 copies/ml in both compartments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents and discusses the results of the serviciability and use condition tests carried on an innovative solution for partitions, designated AdjustMembrane developed within a research project. The proposed system is a modular non-loadbearing wall, tensioned between the pavements and ceiling slabs, which are used as anchoring elements. It allows several advantages, related with the weight reduction to achieve a good sustainable performance, such as the reduction of construction costs, energy, and materials, and it is easy to recycle and to reuse, allowing self-construction. Apart from a general presentation of the partition technology, this paper presents and discusses the results of experimental tests carried out. From the results obtained, it is possible to conclude that the solution fulfils the requirements for this typology of wall in terms of resistance to horizontal loads induced by soft and hard body impacts.