976 resultados para new procedure


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new procedure for spectrofluorimetric determination of free and total glycerol in biodiesel samples is presented. It is based on the oxidation of glycerol by periodate, forming formaldehyde, which reacts with acetylacetone, producing the luminescent 3,5-diacetyl-1,4-dihydrolutidine. A flow system with solenoid micro-pumps is proposed for solution handling. Free glycerol was extracted off-line from biodiesel samples with water, and total glycerol was converted to free glycerol by saponification with sodium ethylate under sonication. For free glycerol, a linear response was observed from 5 to 70 mg L(-1) with a detection limit of 0.5 mg L(-1), which corresponds to 2 mg kg(-1) in biodiesel. The coefficient of variation was 0.9% (20 mg L(-1), n = 10). For total glycerol, samples were diluted on-line, and the linear response range was 25 to 300 mg L(-1). The detection limit was 1.4 mg L(-1) (2.8 mg kg(-1) in biodiesel) with a coefficient of variation of 1.4% (200 mg L(-1), n = 10). The sampling rate was ca. 35 samples h(-1) and the procedure was applied to determination of free and total glycerol in biodiesel samples from soybean, cottonseed, and castor beans.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper has the objective to evaluate retrospectively the long-term results of transhepatic treatment of PV stenoses after pediatric LT. During an eight-yr period, 15 children with PV stenoses underwent PTA with balloon dilation or stent placement in case of PTA failure after LT. Patients` body weights ranged from 9.3 to 46 kg (mean, 15.5 kg). PV patency was evaluated in the balloon dilation and in the stent placement groups. Technical and clinical successes were achieved in all cases with no complication. Eleven patients (11/15; 73.3%) were successfully treated by single balloon dilation. Four patients (4/15; 26.7%) needed stent placement. One patient was submitted to stent placement during the same procedure because of PTA failure. The other three developed clinical signs of portal hypertension because of PV restenoses two, eight, and twenty-eight months after the first PTA. They had to be submitted to a new procedure with stent placement. The follow-up time ranged from 3 to 8.1 yr (mean, 6.3 yr). In conclusion, transhepatic treatment of PV stenoses after pediatric LT with balloon dilation or stent placement demonstrated to be a safe and effective treatment that results in long-term patency.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este trabalho insere-se no domínio da calibração energética dos equipamentos SPT, dando seguimento ao disposto na norma EN ISO 22476-3, de aplicação obrigatória em Portugal. Para tal foi utilizada uma vara instrumentada, cuja instrumentação consiste em strain-gauges e acelerómetros piezoeléctricos. Esta instrumentação encontra-se fixa a um trecho de vara com comprimento de 60 cm e para a aquisição dos dados foi utilizado o sistema SPT Analyzer® comercializado pela firma PDI. O sistema permite registar os dados provenientes da instrumentação: sinais de um par de strain-gauges, transformados em registos de força (F1 e F2) e sinais de um par de acelerómetros, convertidos em registos de velocidade (V1 e V2) ao longo do tempo. O equipamento permite a avaliação, em tempo real, da qualidade dos registos e da energia máxima transmitida à vara em cada golpe e o conhecimento do deslocamento vertical do trem de varas ocorrido em cada golpe do martelo. Por outro lado, baseando-se no tema acima referido, pretende-se ainda desenvolver esforços no sentido de melhorar o novo método interpretativo dos resultados dos ensaios SPT e sua aplicação ao dimensionamento de estacas, dado que a previsão da capacidade de carga de estacas constitui um dos desafios da engenharia de fundações por requerer a estimativa de propriedades do solo, alterações pela execução da fundação e conhecimento do mecanismo de interacção solo-estaca. Este novo procedimento baseia-se nos princípios da dinâmica, rompendo com as metodologias até aqui consagradas, de natureza essencialmente empírica. A nova forma de interpretar os ensaios SPT, consubstanciada nos princípios de conservação de energia na cravação do amostrador SPT, irá permitir converter analiticamente o valor Nspt numa força dinâmica de reacção à penetração. A decomposição desta força dinâmica permite efectuar análises comparativas entre as resistências unitárias mobilizadas no amostrador SPT (modelo) e as mobilizadas na estaca (protótipo).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new procedure for determining eleven organochlorine pesticides in soils using microwave-assisted extraction (MAE) and headspace solid phase microextraction (HS-SPME) is described. The studied pesticides consisted of mirex, α- and γ-chlordane, p,p’-DDT, heptachlor, heptachlor epoxide isomer A, γ-hexachlorocyclohexane, dieldrin, endrin, aldrine and hexachlorobenzene. The HS-SPME was optimized for the most important parameters such as extraction time, sample volume and temperature. The present analytical procedure requires a reduced volume of organic solvents and avoids the need for extract clean-up steps. For optimized conditions the limits of detection for the method ranged from 0.02 to 3.6 ng/g, intermediate precision ranged from 14 to 36% (as CV%), and the recovery from 8 up to 51%. The proposed methodology can be used in the rapid screening of soil for the presence of the selected pesticides, and was applied to landfill soil samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Trabalho de Projeto Apresentado ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Auditoria, sob orientação do Mestre Carlos Mendes e coorientação da Engª Sónia Rodrigues

Relevância:

60.00% 60.00%

Publicador:

Resumo:

RESUMO - Com o aumento da esperança de vida e das doenças crónicas, cada vez se tem implantado mais cardioversores-desfibrilhadores (CDI) para prevenção de morte súbita. O aumento exponencial no número de implantes aumenta o número de seguimentos dos dispositivos, sobrecarregando os profissionais de saúde e comprometendo a qualidade dos serviços prestados. Segundo as recomendações internacionais, um CDI deverá ser vigiado a cada 3 meses, o que perfaz 4 consultas por ano/doente no mínimo, se não existirem episódios de “choques” ou “descompensações” clínicas, e mensalmente quando é atingido o indicador de substituição electiva do gerador. A evolução da tecnologia, de algoritmos, visualização de episódios e terapias requer recursos técnicos e humanos diferenciados e um gasto de tempo considerável no seguimento. Em países como os Estados Unidos da América, em que os doentes têm de percorrer distâncias muito grandes para aceder aos cuidados de saúde, tornou-se preemente a necessidade de um sistema de vigilância alternativo. Nesse sentido, e usando o conceito da telemedicina, foi criado o seguimento/monitorização à distância de dispositivos cardíacos. Este reduz os custos em consultas, deslocações e recursos humanos, uma vez que contempla apenas uma consulta presencial por ano. Por outro lado, aumenta a segurança do doente com a monitorização periódica e a criação de alarmes, permitindo uma assistência de qualidade e intervenção adequada imediata. Aproveitando as vantagens que este tipo de sistema de transmissão remota oferece, procedeu-se no meu serviço, à distribuição inicial de 62 comunicadores a doentes portadores de CDI´s ou com Ressincronizadores Cardíacos (TRC´s1). Apesar de ser considerada uma melhoria na qualidade dos serviços prestados, é também uma mudança importante na metodologia da consulta feita até aqui. Segundo vários autores, a avaliação da qualidade dos cuidados em saúde está intrinsecamente ligada ao grau de satisfação dos doentes com esses serviços, ou seja, à relação entre as suas expectativas e os resultados percebidos por eles, sendo considerado um importante indicador de qualidade dos serviços. Com este trabalho, pretende-se avaliar a percepção dos doentes face ao novo seguimento em termos de aceitação, satisfação, validade, segurança e confiança no novo sistema. Se este mantém os mesmos padrões de qualidade que o seguimento presencial. Trata-se de um estudo transversal com uma componente retrospectiva de avaliação da nova metodologia de consulta à distância. Para tal, foi elaborado um questionário, que foi aplicado a 40 doentes (17,5% do género feminino e 82,5% do género masculino; média de idades de 65 anos) que constituíram a amostra do estudo. Verificou-se uma média de 5 anos de tempo de implante do CDI. Dos dados obtidos, é de realçar que 70% dos inquiridos estão satisfeitos e 30% estão muito satisfeitos com esta nova metodologia de consulta e cerca 67,4% prefere a consulta à distância. Quando solicitados para comparar a qualidade do serviço prestado entre as duas consultas, 65% respondeu igual e 27,5% melhor. Todos os inquiridos responderam ter confiança e segurança com o sistema de consulta à distância. Cerca de 87,5% dos inquiridos vê-se mesmo a continuar com este tipo de consulta. Os resultados obtidos são bastante satisfatórios no que diz respeito à transição do modo como a consulta de CDI´s é feita. Reflectem também que a tecnologia não é necessariamente uma barreira no acesso aos profissionais de saúde, desde que suportada por algum contacto directo (telefone e através de uma consulta presencial por ano). 1 TRC – Terapia de Ressincronização Cardíaca

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Thesis submitted in fulfilment of the requirements for the Degree of Master of Science in Computer Science

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In cataract surgery, the eye’s natural lens is removed because it has gone opaque and doesn’t allow clear vision any longer. To maintain the eye’s optical power, a new artificial lens must be inserted. Called Intraocular Lens (IOL), it needs to be modelled in order to have the correct refractive power to substitute the natural lens. Calculating the refractive power of this substitution lens requires precise anterior eye chamber measurements. An interferometry equipment, the AC Master from Zeiss Meditec, AG, was in use for half a year to perform these measurements. A Low Coherence Interferometry (LCI) measurement beam is aligned with the eye’s optical axis, for precise measurements of anterior eye chamber distances. The eye follows a fixation target in order to make the visual axis align with the optical axis. Performance problems occurred, however, at this step. Therefore, there was a necessity to develop a new procedure that ensures better alignment between the eye’s visual and optical axes, allowing a more user friendly and versatile procedure, and eventually automatizing the whole process. With this instrument, the alignment between the eye’s optical and visual axes is detected when Purkinje reflections I and III are overlapped, as the eye follows a fixation target. In this project, image analysis is used to detect these Purkinje reflections’ positions, eventually automatically detecting when they overlap. Automatic detection of the third Purkinje reflection of an eye following a fixation target is possible with some restrictions. Each pair of detected third Purkinje reflections is used in automatically calculating an acceptable starting position for the fixation target, required for precise measurements of anterior eye chamber distances.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To analyze our experience with percutaneous aortic balloon valvuloplasty in newborn infants with aortic stenosis, emphasizing the extraordinary importance of myocardial perfusion.METHODS: Over a 10-year-period, 21 neonates underwent percutaneous aortic balloon valvuloplasty. Age ranged from 2 to 27 days, weight ranged from 2.2 to 4.1 kg and 19 were males. All patients presented with congestive heart failure that could not be treated clinically. The onset of symptoms in the first week of life occurred in 9 patients considered as having critical aortic stenosis. Severe aortic stenosis occurred in 12 patients with the onset of symptoms in the second week of life.RESULTS: Mortality reached 100% in the patients with critical aortic stenosis. The procedure was considered effective in the 12 patients with severe aortic stenosis. Vascular complications included the loss of pulse in 12 patients and rupture of the femoral artery in 2 patients. Cardiac complications included acute aortic regurgitation in 2 patients and myocardial perforation in one. In an 8.2±1.3-year follow-up, 5 of the 12 patients died (2 patients due to septicemia and 3 patients due to congestive heart failure). Five of the other 7 patients underwent a new procedure and 2 required surgery.CONCLUSION: Percutaneous aortic valvuloplasty in neonates is not an effective procedure in the 1st week of life, because at this age the common presentation is cardiogenic shock. It is possible that, in those patients with critical aortic stenosis, dilation of the aortic valve during fetal life may change the prognosis of its clinical outcome.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recently there has been a renewed research interest in the properties of non survey updates of input-output tables and social accounting matrices (SAM). Along with the venerable and well known scaling RAS method, several alternative new procedures related to entropy minimization and other metrics have been suggested, tested and used in the literature. Whether these procedures will eventually substitute or merely complement the RAS approach is still an open question without a definite answer. The performance of many of the updating procedures has been tested using some kind of proximity or closeness measure to a reference input-output table or SAM. The first goal of this paper, in contrast, is the proposal of checking the operational performance of updating mechanisms by way of comparing the simulation results that ensue from adopting alternative databases for calibration of a reference applied general equilibrium model. The second goal is to introduce a new updatin! g procedure based on information retrieval principles. This new procedure is then compared as far as performance is concerned to two well-known updating approaches: RAS and cross-entropy. The rationale for the suggested cross validation is that the driving force for having more up to date databases is to be able to conduct more current, and hopefully more credible, policy analyses.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This article provides a fresh methodological and empirical approach for assessing price level convergence and its relation to purchasing power parity (PPP) using annual price data for seventeen US cities. We suggest a new procedure that can handle a wide range of PPP concepts in the presence of multiple structural breaks using all possible pairs of real exchange rates. To deal with cross-sectional dependence, we use both cross-sectional demeaned data and a parametric bootstrap approach. In general, we find more evidence for stationarity when the parity restriction is not imposed, while imposing parity restriction provides leads toward the rejection of the panel stationar- ity. Our results can be embedded on the view of the Balassa-Samuelson approach, but where the slope of the time trend is allowed to change in the long-run. The median half-life point estimate are found to be lower than the consensus view regardless of the parity restriction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE To evaluate immediate transcatheter aortic valve implantation (TAVI) results and medium-term follow-up in very elderly patients with severe and symptomatic aortic stenosis (AS). METHODS This multicenter, observational and prospective study was carried out in three hospitals. We included consecutive very elderly (> 85 years) patients with severe AS treated by TAVI. The primary endpoint was to evaluate death rates from any cause at two years. RESULTS The study included 160 consecutive patients with a mean age of 87 ± 2.1 years (range from 85 to 94 years) and a mean logistic EuroSCORE of 18.8% ± 11.2% with 57 (35.6%) patients scoring ≥ 20%. Procedural success rate was 97.5%, with 25 (15.6%) patients experiencing acute complications with major bleeding (the most frequent). Global mortality rate during hospitalization was 8.8% (n = 14) and 30-day mortality rate was 10% (n = 16). Median follow up period was 252.24 ± 232.17 days. During the follow-up period, 28 (17.5%) patients died (17 of them due to cardiac causes). The estimated two year overall and cardiac survival rates using the Kaplan-Meier method were 71% and 86.4%, respectively. Cox proportional hazard regression showed that the variable EuroSCORE ≥ 20 was the unique variable associated with overall mortality. CONCLUSIONS TAVI is safe and effective in a selected population of very elderly patients. Our findings support the adoption of this new procedure in this complex group of patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We have implemented our new procedure for computing Franck-Condon factors utilizing vibrational configuration interaction based on a vibrational self-consistent field reference. Both Duschinsky rotations and anharmonic three-mode coupling are taken into account. Simulations of the first ionization band of Cl O2 and C4 H4 O (furan) using up to quadruple excitations in treating anharmonicity are reported and analyzed. A developer version of the MIDASCPP code was employed to obtain the required anharmonic vibrational integrals and transition frequencies

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The research presented in this report provides the basis for the development of a new procedure to be used by the Iowa DOT and cities and counties in the state to deal with detours. Even though the project initially focused on investigating new tools to determine condition and compensation, the focus was shifted to traffic and the gas tax method to set the basis for the new procedure. It was concluded that the condition-based approach, even though accurate and consistent condition evaluations can be achieved, is not feasible or cost effective because of the current practices of data collection (two-year cycle) and also the logistics of the procedure (before and after determination). The gas tax method provides for a simple, easy to implement, and consistent approach to dealing with compensation for use of detours. It removes the subjectivity out of the current procedures and provides for a more realistic (traffic based) approach to the compensation determination.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sophisticated magnetic resonance tagging techniques provide powerful tools for the non-invasive assessment of the local heartwall motion towards a deeper fundamental understanding of local heart function. For the extraction of motion data from the time series of magnetic resonance tagged images and for the visualization of the local heartwall motion a new image analysis procedure has been developed. New parameters have been derived which allows quantification of the motion patterns and are highly sensitive to any changes in these patterns. The new procedure has been applied for heart motion analysis in healthy volunteers and in patient collectives with different heart diseases. The achieved results are summarized and discussed.