999 resultados para intermethod comparison


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: The purpose of this in vitro study was to investigate the efficacy of EDTA gel preparation, associated with texapon detergent (EDTA-T), for removing the smear layer at human root surfaces. Method and materials: An experimental smear layer was produced by scaling using periodontal curettes, and the root surfaces were etched with the following concentrations of EDTA-T: 5%, 10%, 15%, 20%, 24%, and negative control (saline solution) for 1, 2, or 3 minutes using both passive and active methods. The surfaces were evaluated by scanning electron microscopy, and photomicrographs were evaluated in relation to smear removal. Results: All EDTA-T groups were more effective than the control group (P < .0001). EDTA-T at 15% was more effective when applied by the passive method, although this difference was not observed for the active method. The active method was statistically better than the passive method (P < .0001). Conclusion: The etching of the root surface with EDTA-T gel by active application, independently of the other factors evaluated, was effective for smear layer removal.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Deep venous thrombosis is a relatively common disease, which can present pulmonary embolism as a complication in its acute phase, and later the post-thrombotic syndrome. Thus, diagnosis should be made as soon as possible, in order to prevent or minimize such complications. Several studies have shown that the symptoms and the clinical signs are inaccurate for the deep venous thrombosis diagnosis and that complementary exams are necessary. As an attempt to simplify the patients' assessment, Well et al., in 1997, developed a clinical prediction index that combines symptoms, signs and risk factors for deep venous thrombosis and managed to make a simpler approach through an association of this index with the complementary exams. Phlebography has been considered the gold standard of complementary exams. However, since it is an invasive exam and thus subject to complications, other diagnostic methods were introduced aiming at making the diagnostic approach simpler and less invasive. Doppler ultrasound, duplex scan, impedance plethysmography, computed tomography, and blood tests such as the D-dimer are some of the available methods for assessing the patient with suspicion of deep venous thrombosis. Among them, duplex scan has shown excellent accuracy and it is currently widely accepted as the first choice test for approaching the patient with deep venous thrombosis. Several authors have suggested an association of diagnostic methods to simplify and make the assessment of such patients more cost-effective, leading to the introduction of a wide range of diagnostic strategies. The different diagnostic methods used for assessing deep venous thrombosis are discussed, as well as a review of the literature on the accuracy, advantages and disadvantages of these methods. Copyright © 2005 by Sociedade Brasileira de Angiologia e Cirurgia Vascular.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As arterial hypertension can be diagnosed by different methods, among which are the traditional auscultatory instrument and the automated oscillometric monitor, the aim of this study was to compare the performance of these instruments, to evaluate the reliability of the digital oscillometer. The sample consisted of 40 patients under dental treatment, whose blood pressure measurements were recorded. The measurements of systolic and diastolic blood pressures were evaluated in terms of their intraclass correlation coefficients (r). For systolic blood pressure, an excellent level of agreement was found between the instruments, with r=0.93, and for diastolic blood pressure, there was a good level of agreement (r=0.75). It was concluded, from the excellent agreement for systolic blood pressure, that the oscillometric monitor can be recommended for the monitoring of the variations of that pressure in the same individual, while the good agreement obtained in the determination of the diastolic blood pressure indicates that the oscillometric method is reliable. However, new studies need to be carried out for a better understanding of the disagreements that can occur in the diastolic pressure results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Delay in diagnosis of pulmonary and other forms of tuberculosis (TB) can be fatal, particularly in HIV-infected patients. Hence, techniques based on nucleic acid amplification, which are both rapid and of high specificity and sensitivity, are now widely used and recommended for laboratories that diagnose TB. In the present study, diagnostic methods based on mycobacterial DNA amplification were evaluated in comparative trials alongside tradicional bacterial methods, using negative smear samples from patients with clinically-suspected TB (sputum samples from 25 patients with suspected pulmonary TB, urine samples from two patients with suspected renal TB and cerebrospinal fluid samples from one patient with suspected meningeal TB). A specificity of 100% was achieved with DNA amplification methods and tradicional culture/identification methods, in relation to clinical findings and treatment results. For the smear-negative sputa, conventional PCR for M. tuberculosis was positive in 62% of suspected lung TB case, showing the same sensitivity as bacterial identification. Both techniques failed in the detection of extra-pulmonary samples. Nested PCR showed, after species-specific amplification, a sensitivity of 100% for M. avium and 85% for M. tuberculosis. For extra-pulmonary smear-negative samples, only Nested PCR detected M. tuberculosis and all cases were confirmed clinically. Nested PCR, in which two-step amplification reactions are performed, can identify the two most important mycobacteria in human pathology quickly and directly from clinical spicimens.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Microwaves have been used in organic synthesis, since 1986, and have proved advantageous in several respects: the possibility of higher yields, greater selectivity and less thermal decomposition. Phthalimide and its derivatives constitute an important class of compounds for use in synthetic organic chemistry; in medicinal chemistry, it is considered an important biophore, acting as a pharmacophoric structural subunit for the synthesis of a number of compounds with different pharmacological uses, such as against sickle-cell disease. The purpose of the work reported here was to develop an alternative method for the synthesis of phthalimide derivatives by exploiting the condensation of phthalic anhydride with amino groups under microwave radiation. The results showed that phthalimide derivatives were obtained in shorter reaction times (5-10 min) and higher yields (60-89%) than by with conventional heating (reflux), demonstrating the potential use of microwaves in the synthesis of this class of molecules.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The study evaluated the efficiency of diagnostic laboratory methods to detect anti-Toxoplasma gondii antibodies in paired serum and aqueous humour samples from experimentally infected pigs. 18-mixed breed pigs were used during the experiment; these were divided into two groups, G1 (infected group, n = 10) and G2 (uninfected group, n = 8). Infection was performed with 4 × 10 4 VEG strain oocysts at day 0 by the oral route in G1 animals. All pigs were euthanized at day 60, when retina, aqueous humour, and blood samples were collected. Anti-T. gondii antibody levels were assessed in serum (s) and aqueous humour (ah) by indirect immunofluorescence assay (IFA), modified agglutination test (MAT), m-ELISA (using crude membranes from T. gondii tachyzoites as antigen) and r-ELISA (using rhoptries from T. gondii tachyzoites as antigen). Polymerase chain reactions (PCR) of samples from the retina were performed by using Tox4 and Tox5 primers. Antibody titers of G1 animals ranged from 128 to 1024 and from 16 to 256 in serum and aqueous humour, respectively. There were differences in the correlation coefficients between IFA(s) × IFA (ah) (r = 0.62, P = 0.05), MAT(s) × MAT (ah) (r = 0.97, P < 0.0001); however, there was no significant difference between r-ELISA(s) × r-ELISA (ah) (r = 0.14, P = 0.7). Antibodies present in serum and aqueous humour recognized similar antigens. Samples of retina were positive by PCR in 30% (3/10) of infected pigs. G2 animals remained without antibody levels and were PCR negative throughout the experiment. These results suggest that the use of a combination of tests and immunoblotting for paired aqueous humour and serum samples could improve the sensitivity and specificity for the diagnosis of ocular toxoplasmosis. © 2007 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Compromised balance and loss of mobility are among the major consequences of Parkinson's disease (PD). The literature documents numerous effective interventions for improving balance and mobility. The purpose of this study was to verify the effectiveness of two exercise programs on balance and mobility in people with idiopathic PD. Thirty-four participants, with idiopathic PD that ranged from Stage I to Stage III on the Hoehn & Yahr (H&Y) scale, were assigned to two groups. Group 1 (n = 21; 67±9 years old) was engaged in an intensive exercise program (aerobic capacity, flexibility, strength, motor coordination and balance) for 6 months: 72 sessions, 3 times a week, 60 minutes per session; while Group 2 (n = 13; 69±8 years old) participated in an adaptive program (flexibility, strength, motor coordination and balance) for 6 months: 24 sessions, once a week, 60 minutes per session. Balance and basic functional mobility were assessed in pre- and post-tests by means of the Berg Balance Scale and the Timed Up and Go Test. Before and after the interventions, groups were similar in clinical conditions (H&Y, UPDRS, and Mini-Mental). A MANOVA 2 (programs) by 2 (moments) revealed that both groups were affected by the exercise intervention. Univariate analyses showed that participants improved their mobility and balance from pre- to post-test. There were no differences between groups in either mobility or balance results. Both the intensive and adaptive exercise programs improved balance and mobility in patients with PD. © 2009 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To describe two successful cases of utilizing refrozen blastocysts by vitrification derived from supernumerary embryos. Design: Case report. Setting: Private fertility clinic. Subjects: Two infertility couple. Interventions: Refrozen blastocysts by vitrification derived from supernumerary embryos. Main outcome measures: Obstetric and pediatric results. Results: Two pregnancies obtained from refrozen-warmed blastocysts led to two healthy babies being born without clinical or genetic problems. Conclusion: These case reports support the notion of safely repeating cryopreservation. However, despite these favorable results, there is still a need for prospective controlled studies on the obstetric and neonatal repercussions of refreezing and of vitrification in particular. © 2010 Middle East Fertility Society.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Gymnema sylvestre extract (GSE) is a plant product widely used as an adjuvant in the treatment of diabetes mellitus and commercially available as a powder. Owing to its low flowability, the manufacturing of hard gelatin capsules containing GSE faces specific problems. The purpose of this study was to investigate the best excipient (starch, lactose or microcrystalline cellulose) for hard gelatin capsules containing GSE. The technological properties such us bulk density (ρβ); tapped density (ρt); inter-particle porosity (Ie); Carr index (CI); Hausner ratio (HR); loss on drying (%LOD) and particle size distribution (%Pf) of the various GSE mixtures were investigated with the aim of identifying the best excipient. The need for lubricants (talc/magnesium stearate) was also assessed. GSE was characterized as a fine powder with more than 50% of its particles between 0.149mm to 0.250mm; furthermore, CI=25.6%; RH=1.3 and Ie = 25.6% and, as expected with such properties, it showed poor flowability. All the excipients investigated were able to change the technological properties of GSE and the powder mixture containing microcrystalline cellulose gave the best results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. To present an overview of the literature about the efficacy of neuromuscular electrical stimulation (NMES) in the rehabilitation of neurogenic oropharyngeal dysphagia and to compare methods of therapy in stroke. Method. An extensive bibliographic survey of several databases (Medline, Scielo Brazil, Chile and Spain and Lilacs) was performed using the following keywords: deglutition disorders, therapy, electrical stimulation, pharynx and stroke between 1990 and 2011. Results. The articles reported the use of NMES in heterogeneous population; there is no consensus thus far about the method used during the NMES and about its rehabilitation efficacy in neurogenic oropharyngeal dysphagia. Conclusions. After this study, we concluded that further investigations are necessary with homogeneous groups of patients with neurogenic dysphagia, discussing the proposition of a specific NMES protocol for the rehabilitation of neurogenic oropharyngeal dysphagia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed to assess the performance of International Caries Detection and Assessment System (ICDAS), radiographic examination, and fluorescence-based methods for detecting occlusal caries in primary teeth. One occlusal site on each of 79 primary molars was assessed twice by two examiners using ICDAS, bitewing radiography (BW), DIAGNOdent 2095 (LF), DIAGNOdent 2190 (LFpen), and VistaProof fluorescence camera (FC). The teeth were histologically prepared and assessed for caries extent. Optimal cutoff limits were calculated for LF, LFpen, and FC. At the D 1 threshold (enamel and dentin lesions), ICDAS and FC presented higher sensitivity values (0.75 and 0.73, respectively), while BW showed higher specificity (1.00). At the D 2 threshold (inner enamel and dentin lesions), ICDAS presented higher sensitivity (0.83) and statistically significantly lower specificity (0.70). At the D 3 threshold (dentin lesions), LFpen and FC showed higher sensitivity (1.00 and 0.91, respectively), while higher specificity was presented by FC (0.95), ICDAS (0.94), BW (0.94), and LF (0.92). The area under the receiver operating characteristic (ROC) curve (Az) varied from 0.780 (BW) to 0.941 (LF). Spearman correlation coefficients with histology were 0.72 (ICDAS), 0.64 (BW), 0.71 (LF), 0.65 (LFpen), and 0.74 (FC). Inter- and intraexaminer intraclass correlation values varied from 0.772 to 0.963 and unweighted kappa values ranged from 0.462 to 0.750. In conclusion, ICDAS and FC exhibited better accuracy in detecting enamel and dentin caries lesions, whereas ICDAS, LF, LFpen, and FC were more appropriate for detecting dentin lesions on occlusal surfaces in primary teeth, with no statistically significant difference among them. All methods presented good to excellent reproducibility. © 2012 Springer-Verlag London Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

CLSI method M27-A3 is not available for use with dimorphic fungi, such as those of the Paracoccidioides genus. In this study, we developed a microdilution method and added the alamarBlue reagent to test the responses of Paracoccidioides brasiliensis and Paracoccidioides lutzii against amphotericin B and itraconazole antifungals. The test proved to be sensitive, practical, and inexpensive and can be used to monitor the activity of low-growth microorganisms and their response to various drugs. © 2013, American Society for Microbiology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of an amperometric biosensor for the salicylate determination in blood serum is described. The biosensor is based on salicylate hydroxylase (EC 1.14.13.1) electropolymerized onto a glassy carbon-working electrode with polypyrrole and glutaraldehyde, to improve the biosensor lifetime. The hexacyanoferrate (II) was also incorporated to work as a redox mediator to minimize possible interferences. The salicylate is enzymatically converted to catechol, which is monitored amperometrically by its electrooxidation at +0.170 V versus SCE (saturated calomel electrode). Salicylate determination was carried out maintaining the ratio between β-NADH and salicylate at 4:1 (30°C). The amperometric response of the biosensor was linearly proportional to the salicylate concentration between 2.3 x 10-6 and 1.4 x 10-5 mol l- 1, in 0.1 mol l-1 phosphate buffer (pH 7.8), containing 0.1 mol l-1 KCl and 5.0 x 10-4 mol l-1 Na2H2EDTA, as supporting electrolyte. The recovery studies, in the presence of several interfering compounds, showed recoveries between 96.4 and 104.8%. The useful lifetime of the biosensor in the concentration range evaluated was at least 40 days, in continuous use. Blood serum samples analyzed by this biosensor showed a good correlation compared to the spectrophotometric method (Trinder) used as reference, presenting relative deviations lower than 7.0%. (C) 2000 Elsevier Science B.V.