995 resultados para indirect ice detection


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Polymer based scintillator composites have been fabricated by combining poly(vinylidene fluoride) (PVDF) and Gd2O3:Eu nanoparticles (50nm). PVDF has been used since it is a flexible and stable binder matrix and highly resistance to thermal and light deterioration. Gd2O3:Eu has been selected as scintillator material due to its wide band gap, high density and suitable visible light yield. The structural, mechanical, thermal and electrical characteristics of the composites were studied as a function of filler content, together with their performance as scintillator material. The introduction of Gd2O3:Eu nanoparticles into the PVDF matrix does not influence the morphology of the polymer or the degree of crystallinity. On the other hand, an increase of the Young´s modulus with respect to PVDF matrix is observed for filler contents of 0.1-0.75 wt.%. The introduction of Gd2O3:Eu into the PVDF matrix increases dielectric constant and DC electrical conductivity as well as the visible light yield in the nanocomposite, being this increase dependent upon Gd2O3:Eu content and X-ray input power. In this way, Gd2O3:Eu/PVDF composites shows suitable characteristics to be used as X-ray radiation transducers, in particular for large area applications.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An indirect haemagglutination (IH) test is described for the detection of Clostridium perfringens type A enterotoxin, produced by strains isolated from human cases of food poisoning and from contaminated food. Though no strict relationship could be observed between titers in the IH test and the time it took mice to die from the intravenous inoculation of mice (IIM), results of the supernatants examined by both methods demonstrated that the IH test was more sensitive than the ILM one. No unspecific reaction was obtanined int he IH wirh a negative control and the inhibitions of the IH and IIM tests by specific antiserum against C. perfringens enterotoxin showed that the IH test is very spcific. The IH assay is recommended for its sensitivity and easy performance by less-equipped laboratories, by these and other data.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to evaluate the indirect immunoperoxidase virus neutralization (IPVN) and mouse neutralization test (MNT) to detect antibodies against rabies virus from vaccinated dogs and cattle. The IPVN was set up for the ability to measure 0.5 International Units/ml (IU) of antibody required by the World Health Organization and the Office International des Epizooties as the minimum response for proof of rabies immunization. IPVN was developed and standardized in chicken embryo related (CER) cell line when 141 dog and 110 cattle sera were applied by serial five-fold dilutions (1:5, 1:25, 1:125) as well as the positive and negative reference controls, all added in four adjacent wells, of 96-well microplates. A 50 µl amount of CVS32 strain dilution containing 50-200 TCID50/ml was mixed to each serum dilution, and after 90 min 50 µl of 3 x 10(5) cells/mlcell suspension added to each well. After five days of incubation, the monolayers were fixed and the IPVN test performed. The correlation coefficient between the MNT and IPVN performed in CER cells was r = 0.9949 for dog sera (n = 100) and r = 0.9307 for cattle sera (n = 99), as well as good specificity (94.7%), sensitivity (87.5%), and agreement (96.6%) were also obtained. IPVN technique can adequately identify vaccinated and unvaccinated animals, even from low-responding vaccinated animals, with the advantage of low cost and faster then MNT standard test.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The study determined the sensitivity and specificity of the indirect fluorescent antibody test (IFAT) and modified agglutination test (MAT) for anti-Toxoplasma gondii antibody detection by analyzing sera from 46 experimentally infected pigs. Values for sensitivity were 95.7% (confidence interval 95%: 84.0-99.2%) and for specificity 97.8% (confidence interval 95%: 87.0-99.9%) in both tests. There was an optimum agreement of results between IFAT and MAT evidenced by a Kappa test of 0.86. These results validate these tests for the detection of T. gondii infection in pigs. IFAT and MAT despite methodologies with different characteristics and readings have similar accuracy in pig serum samples.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An indirect hemagglutination test for a seroepidemiological survey of Streptococcus pyogenes infection was standardized. This is an improved modification of the indirect hemagglutination test which utilizes an unstable reagent prepared with fresh blood cells. Two types of bacterial antigens represented by extracellular products and purified streptolysin O were assayed, but only the former antigen gave good results. Pretreatment of the bacterial antigen with 0.15 M NaOH and neutralization to pH 5.5, as well as postfixation of sensitized red cells with 0.1% glutaraldehyde at 56oC for 30 min were found to be essential to give long stability to the reagent in liquid suspension, at least 9 months at 4oC. A total of 564 serum samples with high, moderate and low anti-streptolysin O antibodies as determined by the neutralization assay were studied by the indirect hemagglutination test using the new reagent. The sensitivity, specificity, efficiency, positive predictive value and negative predictive value of the test in relation to the neutralization assay were 0.950, 0.975, 0.963, 0.973, and 0.955, respectively. The kappa agreement index between the two techniques was high (0.926) and ranked as "almost perfect". Antibody levels detected by both techniques also presented a high positive correlation (rs = 0.726). Five reagent batches successively produced proved to be reproducible. Thus, the improved indirect hemagglutination test seems to be useful for public health laboratories.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to evaluate the indirect immunoperoxidase virus neutralization (IPVN) and mouse neutralization test (MNT) to detect antibodies against rabies virus from vaccinated dogs and cattle. The IPVN was set up for the ability to measure 0.5 International Units/ml (IU) of antibody required by the World Health Organization and the Office International des Epizooties as the minimum response for proof of rabies immunization. IPVN was developed and standardized in chicken embryo related (CER) cell line when 141 dog and 110 cattle sera were applied by serial five-fold dilutions (1:5, 1:25, 1:125) as well as the positive and negative reference controls, all added in four adjacent wells, of 96-well microplates. A 50 µl amount of CVS32 strain dilution containing 50-200 TCID50/ml was mixed to each serum dilution, and after 90 min 50 µl of 3 x 10(5) cells/mlcell suspension added to each well. After five days of incubation, the monolayers were fixed and the IPVN test performed. The correlation coefficient between the MNT and IPVN performed in CER cells was r = 0.9949 for dog sera (n = 100) and r = 0.9307 for cattle sera (n = 99), as well as good specificity (94.7%), sensitivity (87.5%), and agreement (96.6%) were also obtained. IPVN technique can adequately identify vaccinated and unvaccinated animals, even from low-responding vaccinated animals, with the advantage of low cost and faster then MNT standard test.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An indirect fluorescent test was developed for detecting antibodies to Paracoccidioides brasiliensis using bentonite particles as antigen (Bent-IF). The bentonite particles were coated with P. brasiliensis polysaccharide antigen and tested with sera from paracoccidioidomycosis patients (36 sera), normal blood donors (32 sera) and patients with non-mycotic diseases (29 sera). The titres given by the positive sera were compared with those of complement fixation (CF), immunodiffusion (ID) and immunofluorescent test using yeast forms of the fungus as antigen (conventional-IF). All normal blood donors' sera gave a negative Bent-IF, conventional-IF, ID and CF tests. All paracoccidioidomycosis sera were reactive in conventional-IF and gave concordant results in Bent-IF. There was no correlation between CF and Bent-IF titres. 27·6% of sera from patients with non-mycotic diseases gave weak titres in both IF-tests. The present data indicate that the Bent-IF is a sensitive and simple serodiagnostic technique comparable with the conventional P. brasiliensis antibody test. © 1983.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study is to develop a new enzymeless electroanalytical method for the indirect quantification of creatinine from urine sample. This method is based on the electrochemical monitoring of picrate anion reduction at a glassy carbon electrode in an alkaline medium before and after it has reacted with creatinine (Jaffe's reaction). By using the differential pulse voltammetry technique under the optimum experimental conditions (step potential, amplitude potential, reaction time, and temperature), a linear analytical curve was obtained for concentrations of creatinine ranging from 1 to 80 mu mol L-1, with a detection limit of 380 nmol L-1. This proposed method was used to measure creatinine in human urine without the interference of most common organic species normally present in biological fluids (e.g., uric acid, ascorbic acid, glucose, and phosphocreatinine). The results obtained using urine samples were highly similar to the results obtained using the reference spectrophotometric method (at a 95% confidence level). (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An indirect enzyme-linked immunosorbent assay (ELISA) was modified and validated to detect antibodies against Salmonella Abortusovis in naturally infected sheep. The ELISA was validated with 44 positive and 45 negative control serum samples. Compared with the immunoblot, the sensitivity and specificity of the assay were 98% and 100%, respectively. To follow antibody levels over time, samples from 12 infected ewes were collected at 1, 3, and 10 months after abortion. All animals showed antibody levels above the cutoff value throughout the observation period. One and 3 months after abortion, high antibody levels could be detected in all but one animal, whereas after 10 months, 9 animals had markedly lower but still positive antibody levels. The test characteristics and evidence for the persistence of detectable antibody levels in all infected animals for up to 10 months indicates that the ELISA can be used for herd surveillance testing.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

When drilling ice cores deeper than ∼100 m, drill liquid is required to maintain ice-core quality and to limit borehole closure. Due to high-pressure air bubbles in the ice, the ice core can crack during drilling and core retrieval, typically at 600–1200 m depth in Greenland. Ice from this 'brittle zone' can be contaminated by drill liquid as it seeps through cracks into the core. Continuous flow analysis (CFA) systems are routinely used to analyse ice for chemical impurities, so the detection of drill liquid is important for validating accurate measurements and avoiding potential instrument damage. An optical detector was constructed to identify drill liquid in CFA tubing by ultraviolet absorption spectroscopy at a wavelength of 290 nm. The set-up was successfully field-tested in the frame of the NEEM ice-core drilling project in Greenland. A total of 27 cases of drill liquid contamination were identified during the analysis of 175 m of brittle zone ice. The analyses most strongly affected by drill liquid contamination include insoluble dust particles, electrolytic conductivity, ammonium, hydrogen peroxide and sulphate. This method may also be applied to other types of drill liquid used at other drill sites.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

It has long been known that cholera outbreaks can be initiated when Vibrio cholerae, the bacterium that causes cholera, is present in drinking water in sufficient numbers to constitute an infective dose, if ingested by humans. Outbreaks associated with drinking or bathing in unpurified river or brackish water may directly or indirectly depend on such conditions as water temperature, nutrient concentration, and plankton production that may be favorable for growth and reproduction of the bacterium. Although these environmental parameters have routinely been measured by using water samples collected aboard research ships, the available data sets are sparse and infrequent. Furthermore, shipboard data acquisition is both expensive and time-consuming. Interpolation to regional scales can also be problematic. Although the bacterium, V. cholerae, cannot be sensed directly, remotely sensed data can be used to infer its presence. In the study reported here, satellite data were used to monitor the timing and spread of cholera. Public domain remote sensing data for the Bay of Bengal were compared directly with cholera case data collected in Bangladesh from 1992–1995. The remote sensing data included sea surface temperature and sea surface height. It was discovered that sea surface temperature shows an annual cycle similar to the cholera case data. Sea surface height may be an indicator of incursion of plankton-laden water inland, e.g., tidal rivers, because it was also found to be correlated with cholera outbreaks. The extensive studies accomplished during the past 25 years, confirming the hypothesis that V. cholerae is autochthonous to the aquatic environment and is a commensal of zooplankton, i.e., copepods, when combined with the findings of the satellite data analyses, provide strong evidence that cholera epidemics are climate-linked.